Abstract:
:A retrospective review was done of intracranial images obtained within the newborn period in 46 infants who had been treated with extracorporeal membrane oxygenation (ECMO). A neuroimaging score was determined on the basis of the extent and severity of findings on both ultrasound and computed tomographic scans. Presence of abnormality at neuroimaging and the neuroimaging score were correlated with the findings of neurodevelopmental evaluations (Bayley scales) performed in infants who were at a mean age of 11.8 months (range, 6-16 months). A significant inverse correlation was found between the neuroimaging score and mental and psychomotor development indexes of the Bayley scale (P less than .005). Mean neuroimaging scores in infants with normal development were significantly lower than those in infants with delayed development (P = .002). Although individual outcomes cannot be predicted with neuroimaging, the neuroimaging score can be a useful adjunct in assigning patients who survive with ECMO treatment to risk categories for developmental outcome.
journal_name
Radiologyjournal_title
Radiologyauthors
Taylor GA,Glass P,Fitz CR,Miller MKdoi
10.1148/radiology.165.3.3317500subject
Has Abstractpub_date
1987-12-01 00:00:00pages
679-82issue
3eissn
0033-8419issn
1527-1315journal_volume
165pub_type
杂志文章相关文献
RADIOLOGY文献大全abstract::In 24 CT studies in children with brain stem gliomas, the CT appearance was seen to vary with the tumor's physical characteristics. Infiltrative tumors produce diffuse enlargement of the brain stem; they are isodense with brain parenchyma or of decreased density and may show partial enhancement. Some gliomas grow foca...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.134.1.7350640
更新日期:1980-01-01 00:00:00
abstract::Five cases, four histologically proved, or hamartoma of the tuber cinereum and hypothalamus in children (age range: 2--12 years) are reported. Three cases had pubertas praecox, and in all of these the hamartoma was located in the basal cistern between the chiasm and pons, and had a collar button shape and size typical...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/127.3.697
更新日期:1978-06-01 00:00:00
abstract::Magnetic resonance (MR) imaging-related artifacts associated with five different aneurysm clips made of five different metals (commercially pure titanium, titanium alloy, Phynox, Elgiloy, and cobalt alloy) were evaluated. Aneurysm clips made of commercially pure titanium and titanium alloy produced the smallest artifa...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.209.2.9807590
更新日期:1998-11-01 00:00:00
abstract::Irradiation of the orbit is often associated with substantial dose inhomogeneity resulting from the insertion of lens blocks. We postulated that such dose inhomogeneity, which often exceeds 40%, could be halved by the use of two pairs of wedged beams, one angled in the sagittal plane and the other in the commonly empl...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.156.3.4023250
更新日期:1985-09-01 00:00:00
abstract:PURPOSE:To retrospectively determine whether baseline nodule characteristics at 3-month and 1-year volume doubling time (VDT) are predictive for lung cancer in solid indeterminate noncalcified nodules (NCNs) detected at baseline computed tomographic (CT) screening. MATERIALS AND METHODS:The study, conducted between Ap...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2493070847
更新日期:2009-01-01 00:00:00
abstract::Significant structural and mechanical differences exist between the titanium and stainless steel versions of the Greenfield filter (GF). The titanium GF has a longer leg length (49 mm vs 43 mm), a greater span (38.5 mm vs 28.0 mm), and a larger hook angle (41 degrees vs 23.5 degrees). In vitro tests demonstrated appro...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.173.3.2813790
更新日期:1989-12-01 00:00:00
abstract::A systems approach was employed to improve results of the single-contrast barium enema examination for detection of colonic polyps. Improvements were made in each of the following areas: radiographic-fluoroscopic equipment, fluoroscopic-television images, screen-film combinations, barium suspensions, examination techn...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.164.2.3602370
更新日期:1987-08-01 00:00:00
abstract::An International Symposium was held in Atlanta in 1992 to present the state of the art of diagnostic evaluation and management of acute pancreatitis and to agree on an acceptable series of clinical definitions for classifying the disease and its complications. The symposium was composed of 40 internationally recognize...
journal_title:Radiology
pub_type: 杂志文章,评审
doi:10.1148/radiology.193.2.7972730
更新日期:1994-11-01 00:00:00
abstract:PURPOSE:To investigate if magnetic resonance (MR) enteroclysis can be performed routinely and to compare MR enteroclysis findings with those of conventional enteroclysis or surgery. MATERIALS AND METHODS:MR enteroclysis was prospectively performed in 30 patients with symptoms of inflammatory bowel disease or small-bow...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.215.3.r00jn12717
更新日期:2000-06-01 00:00:00
abstract::Computed tomography of the brain was used in evaluating demented and nondemented elderly people. The incidence of convulutional atrophy and ventricular enlargement correlated well with pathologic and pneumoencephalographic examination of a similar population. Computed tomography also showed certain instances of dement...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/116.1.85
更新日期:1975-07-01 00:00:00
abstract::Image compression is essential to handle a large volume of digital images, including computed tomographic, magnetic resonance, computed radiographic, and digitized images in a digital radiology operation. Developed during the past few years, full-frame bit allocation performed with the cosine transform technique has b...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.185.2.1410380
更新日期:1992-11-01 00:00:00
abstract::The authors prospectively treated 10 consecutive patients with multiloculated empyemas with intracavitary instillation of urokinase via a percutaneous drainage catheter. Urokinase (100,000 IU) in 100 mL of 5% dextrose in water was instilled into the pleural cavity via a percutaneous drainage catheter. After overnight ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.179.3.2027990
更新日期:1991-06-01 00:00:00
abstract:PURPOSE:To evaluate the feasibility of reconstructing single and multiple targets by using fluorescence-enhanced tomography of a breast tissue phantom. MATERIALS AND METHODS:Frequency-domain fluorescence measurements were performed in cup-shaped tissue phantoms of clinically relevant size (diameter, 10 cm) in which si...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2343031725
更新日期:2005-04-01 00:00:00
abstract::Background Results of recent phantom studies show that variation in CT acquisition parameters and reconstruction techniques may make radiomic features largely nonreproduceable and of limited use for prognostic clinical studies. Purpose To investigate the effect of CT radiation dose and reconstruction settings on the r...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2019190928
更新日期:2019-12-01 00:00:00
abstract:PURPOSE:To test a biopsy needle modified for use of radio-frequency (RF) energy to produce hemostasis after core biopsy of liver or kidney. MATERIALS AND METHODS:RF energy was applied to a partially insulated 17-gauge needle, and tip temperature was monitored with a thermocouple. Domestic Yorkshire pigs (n = 4; mean w...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2272020173
更新日期:2003-05-01 00:00:00
abstract::Fifty cadaver ankles were examined with ankle tenography. The normal tenographic appearance of the peroneus longus and brevis, posterior tibial, flexor digitorum longus, flexor hallucis longus, anterior tibialis, extensor hallucis longus, and extensor digitorum longus tendons and sheaths are described and illustrated ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.151.3.6718710
更新日期:1984-06-01 00:00:00
abstract:PURPOSE:To assess the diagnostic value of spinal ultrasonography (US) in pediatric patients. MATERIALS AND METHODS:The findings on 38 spinal US scans in 30 patients (mean age, 5.5 months) were compared with those of corresponding magnetic resonance (MR) images. RESULTS:MR imaging showed a normal spinal canal in 14 of...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.200.2.8685330
更新日期:1996-08-01 00:00:00
abstract:PURPOSE:To compare the use of electrolytically detachable coils versus surgical ligation for the management of acutely ruptured intracranial aneurysm. MATERIALS AND METHODS:A prospective randomized study included 109 patients with acute (< 72 hours) subarachnoid hemorrhage caused by a ruptured aneurysm (Hunt and Hess ...
journal_title:Radiology
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1148/radiology.211.2.r99ap06325
更新日期:1999-05-01 00:00:00
abstract:PURPOSE:To evaluate how interreader agreement and the site of the volume of interest (VOI) affect the agreement and variability of liver mean standardized uptake value normalized to lean body mass (SUL(mean)) at fluorine 18 fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT). MATERIALS...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.12121385
更新日期:2013-05-01 00:00:00
abstract::Forty-seven females with duplication of the uterus and cervix were retrospectively studied to obtain a better understanding of the reasons for failure of fusion of the müllerian ducts by analyzing the associated genitourinary malformations. Thirty-one of the 47 patients had major genitourinary malformations that corre...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.144.4.6213980
更新日期:1982-09-01 00:00:00
abstract::The theories of decision processes and signal detection provide a framework for evaluation of observer performance. Some radiological procedures involve a search for multiple similar lesions, e.g., plain radiographic examinations for gallstones or pneumoconiosis. Presuming knowledge of the conventional ROC curve for d...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/121.2.337
更新日期:1976-11-01 00:00:00
abstract::Aneurysms of the thoracic aorta simulated primary esophageal disease both clinically and radiographically in 5 patients. Four had an aortoesophageal fistula at the time of presentation; endoscopic biopsy of a presumed esophageal tumor precipitated hematemesis in the fifth patient. In retrospect, the fistulas were demo...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.141.3.7302210
更新日期:1981-12-01 00:00:00
abstract:PURPOSE:To correlate pulsatility index (PI) and resistive index (RI) measured at early specific intervals after transplantation with 1-year estimated glomerular filtration rate (eGFR) and death-censored transplant survival to assess the long-term prognostic value of these Doppler indexes. MATERIALS AND METHODS:The loc...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.10101329
更新日期:2011-04-01 00:00:00
abstract::A new nonionic dimeric contrast medium (CM), iodixanol, was intravenously administered to 40 healthy male volunteers in doses of 0.3-1.2 g of iodine per kilogram of body weight, nonionic monomeric iopamidol and iopentol were administered to 20 others, and the renal effects were studied up to 120 hours after administra...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.182.2.1732960
更新日期:1992-02-01 00:00:00
abstract::Cyst formation in an infarcted bone, though rare, can be diagnosed with reasonable confidence when radiographs show an expanding lytic lesion confined by an intact but attenuated cortex. If the cortex is destroyed and a periosteal response or soft-tissue mass is present, malignant transformation should be suspected. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.146.2.6849080
更新日期:1983-02-01 00:00:00
abstract:PURPOSE:To determine the prevalence of clinically serious findings unrelated to stroke on cranial magnetic resonance (MR) images in a population of community-dwelling elderly people. MATERIALS AND METHODS:Neuroradiologists reviewed MR images of 3,672 people aged 65 years and older who were enrolled in a longitudinal, ...
journal_title:Radiology
pub_type: 杂志文章,多中心研究
doi:10.1148/radiology.202.1.8988190
更新日期:1997-01-01 00:00:00
abstract::An inverse linear correlation was found between patients' ages and the quality of bone scans. The degrees to which radionuclides were visible in soft tissue, kidneys, and particularly cancellous bone were the basis of this correlation. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.139.3.6262860
更新日期:1981-06-01 00:00:00
abstract::A new catheter system was designed for percutaneous fragmentation of large pulmonary emboli. The device consists of an impeller rotating at high speed at the center of a self-expandable basket at the tip of a 7-F catheter. The highly flexible catheter was able to reach all tested embolus sites in a glass model of the ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.180.1.2052680
更新日期:1991-07-01 00:00:00
abstract:PURPOSE:To evaluate the sensitivity and specificity of scintigraphy with technetium 99m white blood cells (WBC) for detection of colonic inflammation in children with and children without inflammatory bowel disease (IBD). MATERIALS AND METHODS:In 215 patients, uptake of 99mTc WBC in 3,440 bowel segments was graded. In...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.212.2.r99au45507
更新日期:1999-08-01 00:00:00
abstract::Forty-nine patients with previous bypass surgery underwent coronary angiography and cardiovascular magnetic resonance (MR) imaging of single-vein bypass grafts. Volume flow and velocity analyses were performed and compared on MR velocity maps. Bland-Altman analysis showed close agreement between the two types of analy...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2323030289
更新日期:2004-09-01 00:00:00