Cavernous hemangiomas of the spinal cord: MR imaging.

Abstract:

:In three patients with histologically proved cavernous hemangiomas of the spinal cord, magnetic resonance (MR) imaging was superior to myelography, delayed computed tomography (CT) myelography, and contrast-enhanced CT in depicting the lesion. The presence of mixed subacute and chronic hemorrhage, suggested by mixed high- and low-signal-intensity components of these lesions on MR images, may be characteristic of this rare, intramedullary vascular malformation.

journal_name

Radiology

journal_title

Radiology

authors

Fontaine S,Melanson D,Cosgrove R,Bertrand G

doi

10.1148/radiology.166.3.3340780

subject

Has Abstract

pub_date

1988-03-01 00:00:00

pages

839-41

issue

3

eissn

0033-8419

issn

1527-1315

journal_volume

166

pub_type

杂志文章
  • Validation of A Method to Compensate Multicenter Effects Affecting CT Radiomics.

    abstract::Background Radiomics extracts features from medical images more precisely and more accurately than visual assessment. However, radiomics features are affected by CT scanner parameters such as reconstruction kernel or section thickness, thus obscuring underlying biologically important texture features. Purpose To inves...

    journal_title:Radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1148/radiol.2019182023

    authors: Orlhac F,Frouin F,Nioche C,Ayache N,Buvat I

    更新日期:2019-04-01 00:00:00

  • Preparation of 52Fe and its use in a 52Fe/52mMn generator.

    abstract::Clinically useful quantities of 52Fe have been prepared at the Brookhaven Linac Isotope Producer (BLIP) by bombarding manganese or nickel targets with medium energy protons. After chemical separation, 52Fe is loaded onto a generator column from which carrier-free 52Mn is eluted. The 52mMn generator is potentially usef...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/132.2.475

    authors: Ku TH,Richards P,Stang LG Jr,Prach T

    更新日期:1979-08-01 00:00:00

  • Testicular blood flow in boys as assessed at color Doppler and power Doppler sonography.

    abstract:PURPOSE:To investigate at which age testicular blood flow can be demonstrated consistently by color Doppler sonography and power Doppler sonography. MATERIALS AND METHODS:In this prospective study, 172 normal testes of 86 boys (age range, 4 days to 15 years) were examined with gray-scale ultrasound, color Doppler sono...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.202.2.9015090

    authors: Bader TR,Kammerhuber F,Herneth AM

    更新日期:1997-02-01 00:00:00

  • High-resolution CT diagnosis of emphysema in symptomatic patients with normal chest radiographs and isolated low diffusing capacity.

    abstract::To determine the prevalence of "nonobstructive" (impairment of gas transfer) emphysema in a select population of smokers with dyspnea, a retrospective study of patients with emphysema evident at high-resolution computed tomography (HRCT) was undertaken. Four hundred seventy HRCT studies were reviewed. In 47 cases, cen...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.182.3.1535900

    authors: Klein JS,Gamsu G,Webb WR,Golden JA,Müller NL

    更新日期:1992-03-01 00:00:00

  • Elusive "stuck" disk in the temporomandibular joint: diagnosis with MR imaging.

    abstract:PURPOSE:To determine the incidence of a "stuck" disk and its importance in the overall scheme of internal derangement. MATERIALS AND METHODS:Magnetic resonance (MR) images of 212 temporomandibular joints (TMJs) in 106 symptomatic patients were obtained and reviewed. Image analysis included assessment of disk position;...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.189.3.8234710

    authors: Rao VM,Liem MD,Farole A,Razek AA

    更新日期:1993-12-01 00:00:00

  • Use of 99mTc (V) DMSA scintigraphy in the detection and localization of intestinal inflammation: comparison of findings and colonoscopy and biopsy.

    abstract:PURPOSE:To evaluate the potential use of technetium 99m (99mTc) (V) dimercaptosuccinic acid (DMSA) scintigraphy in the detection and localization of intestinal inflammation. MATERIALS AND METHODS:In a prospective study, 62 patients who were suspected of having intestinal inflammation and 30 control subjects were enrol...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.220.2.r01au30381

    authors: Lee BF,Chiu NT,Wu DC,Tsai KB,Liu GC,Yu HS,Wang ST

    更新日期:2001-08-01 00:00:00

  • Peritoneocele: visualization with defecography and peritoneography performed simultaneously.

    abstract:PURPOSE:To evaluate the use of simultaneous defecography and peritoneography (defecoperitoneography) in patients with an unexplained widening of the rectovaginal space noted at defecography. MATERIALS AND METHODS:Twenty-two patients with unexplained widening of the rectovaginal space noted at defecography were studied...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.202.2.9015060

    authors: Bremmer S,Mellgren A,Holmström B,López A,Udén R

    更新日期:1997-02-01 00:00:00

  • Comparison of US and unenhanced multi-detector row CT in patients suspected of having acute appendicitis.

    abstract:PURPOSE:To prospectively compare the diagnostic performance of ultrasonography (US) and unenhanced multi-detector row computed tomography (CT) in patients suspected of having acute appendicitis by using surgery or clinical follow-up as the reference standard. MATERIALS AND METHODS:The institutional review board approv...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2362040984

    authors: Keyzer C,Zalcman M,De Maertelaer V,Coppens E,Bali MA,Gevenois PA,Van Gansbeke D

    更新日期:2005-08-01 00:00:00

  • Science to Practice: Can Functional MR Imaging Be Useful in the Evaluation of Cardiorenal Syndrome?

    abstract::Functional magnetic resonance (MR) imaging of the kidneys has gained interest recently, especially in the detection of early changes in acute kidney injury or to predict progression of chronic kidney disease (CKD). The application of these methods to cardiorenal syndrome (CRS) is novel. CRS is widely accepted as a com...

    journal_title:Radiology

    pub_type: 评论,杂志文章

    doi:10.1148/radiol.2017171957

    authors: Pursnani A,Prasad PV

    更新日期:2018-01-01 00:00:00

  • Relationship between Overall Survival of Patients with Non-Small Cell Lung Cancer and Whole-Body Metabolic Tumor Burden Seen on Postsurgical Fluorodeoxyglucose PET Images.

    abstract:PURPOSE:To test the hypothesis that whole-body metabolic tumor burden (MTBWB) on postsurgical fluorodeoxyglucose (FDG) positron emission tomographic (PET)/computed tomographic (CT) images in patients with non-small cell lung cancer (NSCLC) is associated with their overall survival (OS). MATERIALS AND METHODS:The insti...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.14141398

    authors: Zhang C,Liao C,Penney BC,Appelbaum DE,Simon CA,Pu Y

    更新日期:2015-06-01 00:00:00

  • F-18 fluorodeoxyglucose PET in vivo evaluation of pancreatic glucose metabolism for detection of pancreatic cancer.

    abstract:PURPOSE:To evaluate positron emission tomography (PET) with fluorine-18-labeled fluorodeoxyglucose (FDG) for detection of pancreatic cancer compared with computed tomography (CT) and ultrasonography (US). MATERIALS AND METHODS:Forty patients with suspected pancreatic cancer underwent static PET after intravenous injec...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.192.1.8208970

    authors: Bares R,Klever P,Hauptmann S,Hellwig D,Fass J,Cremerius U,Schumpelick V,Mittermayer C,Büll U

    更新日期:1994-07-01 00:00:00

  • Extraocular muscles in Graves ophthalmopathy: usefulness of T2 relaxation time measurements.

    abstract:PURPOSE:To determine if T2 relaxation time measurements with magnetic resonance (MR) imaging in patients with Graves ophthalmopathy (GO) can predict response to therapy. MATERIALS AND METHODS:Studied were 84 patients with GO, 27 with Graves disease without ophthalmopathy (GD), and 12 control subjects without Graves di...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.190.3.8115640

    authors: Ohnishi T,Noguchi S,Murakami N,Tajiri J,Harao M,Kawamoto H,Hoshi H,Jinnouchi S,Futami S,Nagamachi S

    更新日期:1994-03-01 00:00:00

  • Conventional Autopsy versus Minimally Invasive Autopsy with Postmortem MRI, CT, and CT-guided Biopsy: Comparison of Diagnostic Performance.

    abstract::Purpose To compare the diagnostic performance of minimally invasive autopsy with that of conventional autopsy. Materials and Methods For this prospective, single-center, cross-sectional study in an academic hospital, 295 of 2197 adult cadavers (mean age: 65 years [range, 18-99 years]; age range of male cadavers: 18-99...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2018180924

    authors: Blokker BM,Weustink AC,Wagensveld IM,von der Thüsen JH,Pezzato A,Dammers R,Bakker J,Renken NS,den Bakker MA,van Kemenade FJ,Krestin GP,Hunink MGM,Oosterhuis JW

    更新日期:2018-12-01 00:00:00

  • Retrievable vena caval filter percutaneously introduced.

    abstract::A vena caval filter than can be introduced percutaneously via the femoral vein is described. We placed these filters in five patients without complications. Experimental work in filter removal one to two weeks after insertion in dogs has been performed. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.155.3.4001390

    authors: Lund G,Rysavy J,Hunter DW,Castaneda-Zuniga WR,Amplatz K

    更新日期:1985-06-01 00:00:00

  • Characterization of Physiologic (18)F FSPG Uptake in Healthy Volunteers.

    abstract::Purpose To evaluate the normal biodistribution and kinetics of (S)-4-(3-[18F]fluoropropyl)-l-glutamic acid ((18)F FSPG) in healthy volunteers and to compare (18)F FSPG mean and maximum standardized uptake values (SUVmean and SUVmax, respectively) with those of (18)F fluorodeoxyglucose (FDG) across a variety of organs....

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2015142000

    authors: Mosci C,Kumar M,Smolarz K,Koglin N,Stephens AW,Schwaiger M,Gambhir SS,Mittra ES

    更新日期:2016-06-01 00:00:00

  • Cerebrospinal fluid dynamics in infants evaluated with echographic color-coded flow imaging.

    abstract:PURPOSE:To use color Doppler flow ultrasonography (US) for investigation of rapid regional motion of cerebrospinal fluid (CSF) in infants with subarachnoid hemorrhage or meningitis. MATERIALS AND METHODS:Sixty-four transfontanellar and transcranial color Doppler US scans of the cerebral aqueduct, ventricles, and basal...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.192.2.8029410

    authors: Winkler P

    更新日期:1994-08-01 00:00:00

  • Negative-mode soft-tissue xeroradiography.

    abstract::Positive-mode xeroradiography is an excellent method of visualizing soft-tissue structures in mammography and other procedures; however, toner deletions over a large area may preclude adequate delineation of the soft tissues near high-density structures such as bone. Use of the negative mode in the development cycle p...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/124.3.689

    authors: Osterman FA Jr,Zeman GH,Rao GU,Gayler B,Kirk BG,James AE Jr

    更新日期:1977-09-01 00:00:00

  • Transjugular intrahepatic portosystemic shunt: evaluation with Doppler sonography.

    abstract::To assess the potential role of ultrasound (US) in evaluating transjugularly inserted intrahepatic portosystemic shunts, the authors performed sonographic, including duplex and color Doppler, studies in 23 patients. Imaging was performed before, during the first week after, and 2-3 months after shunt placement. The pr...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.186.2.8421760

    authors: Longo JM,Bilbao JI,Rousseau HP,García-Villareal L,Vinel JP,Zozaya JM,Joffre FG,Prieto J

    更新日期:1993-02-01 00:00:00

  • Hepatic malignancies: improved detection with pulse-inversion US in late phase of enhancement with SH U 508A-early experience.

    abstract::Twenty consecutive patients with known liver malignancies underwent ultrasonography (US) in conventional B mode and in pulse-inversion mode in the late hepatic-specific parenchymal phase after intravenous administration of SH U 508A, a microbubble US contrast agent. Two experienced readers assessed subjective and obje...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.216.3.r00se22903

    authors: Harvey CJ,Blomley MJ,Eckersley RJ,Cosgrove DO,Patel N,Heckemann RA,Butler-Barnes J

    更新日期:2000-09-01 00:00:00

  • Gallbladder carcinoma: evaluation with MR imaging.

    abstract::Magnetic resonance (MR) images of 19 patients with histologically proved gallbladder carcinoma were retrospectively reviewed to determine the appearance of the primary tumor, and to assess the ability of MR imaging to demonstrate the various modes of tumor spread beyond the gallbladder. The primary tumor, as well as t...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.174.1.2294540

    authors: Sagoh T,Itoh K,Togashi K,Shibata T,Minami S,Noma S,Yamashita K,Nishimura K,Asato R,Mori K

    更新日期:1990-01-01 00:00:00

  • Reported mammographic density: film-screen versus digital acquisition.

    abstract:PURPOSE:To test the hypothesis that American College of Radiology Breast Imaging Reporting and Data System (BI-RADS) categories for breast density reported by radiologists are lower when digital mammography is used than those reported when film-screen (FS) mammography is used. MATERIALS AND METHODS:This study was inst...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.12120221

    authors: Harvey JA,Gard CC,Miglioretti DL,Yankaskas BC,Kerlikowske K,Buist DS,Geller BA,Onega TL,Breast Cancer Surveillance Consortium.

    更新日期:2013-03-01 00:00:00

  • Type II endoleak after endoaortic graft implantation: diagnosis with helical CT arteriography.

    abstract:PURPOSE:To retrospectively assess endoleak shapes and locations within aneurysms to differentiate type II from type I and type III endoleaks. MATERIALS AND METHODS:The institutional review board granted an exemption for this HIPAA-compliant study; patient informed consent was not required. A retrospective review of ar...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2403051013

    authors: Chernyak V,Rozenblit AM,Patlas M,Cynamon J,Ricci ZJ,Laks MP,Veith FJ

    更新日期:2006-09-01 00:00:00

  • The Effect of Modality and Landmark Selection on MRI and CT Femoral Torsion Angles.

    abstract::Background Assessment of femoral torsion at preoperative hip imaging is commonly recommended. However, it is unclear whether MRI is as accurate as CT and how different methods affect femoral torsion measurements. Purpose To compare MRI- and CT-based assessment of femoral torsion by using four commonly used measurement...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2020192723

    authors: Schmaranzer F,Kallini JR,Miller PE,Kim YJ,Bixby SD,Novais EN

    更新日期:2020-08-01 00:00:00

  • Quantification of bone involvement in Gaucher disease: MR imaging bone marrow burden score as an alternative to Dixon quantitative chemical shift MR imaging--initial experience.

    abstract:PURPOSE:To develop a semiquantitative magnetic resonance (MR) imaging bone marrow burden (BMB) score with inclusion of both axial and peripheral bone marrow in Gaucher disease as an alternative to MR imaging with the Dixon quantitative chemical shift imaging (QCSI) technique. MATERIALS AND METHODS:Two experienced musc...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2292020296

    authors: Maas M,van Kuijk C,Stoker J,Hollak CE,Akkerman EM,Aerts JF,den Heeten GJ

    更新日期:2003-11-01 00:00:00

  • Hypervascular hepatic metastases: CT evaluation.

    abstract::Recent reports have indicated that non-contrast material-enhanced scans are of less value than urographic contrast material-enhanced studies in the computed tomographic (CT) evaluation of hepatic metastases. The authors retrospectively reviewed the CT scans of 28 patients with hypervascular liver metastases to determi...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.162.1.3024210

    authors: Bressler EL,Alpern MB,Glazer GM,Francis IR,Ensminger WD

    更新日期:1987-01-01 00:00:00

  • Lumbosacral transitional vertebrae: association with low back pain.

    abstract:PURPOSE:To assess the prevalence and degree of lumbosacral transitional vertebrae (LSTV) in the Osteoarthritis Initiative (OAI) cohort, to assess whether LSTV correlates with low back pain (LBP) and buttock pain, and to assess the reproducibility of grading LSTV. MATERIALS & METHODS:Institutional review board approval...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.12112747

    authors: Nardo L,Alizai H,Virayavanich W,Liu F,Hernandez A,Lynch JA,Nevitt MC,McCulloch CE,Lane NE,Link TM

    更新日期:2012-11-01 00:00:00

  • Use of Public Data to Target Variation in Providers' Use of CT and MR Imaging among Medicare Beneficiaries.

    abstract:PURPOSE:To examine geographic variation in providers' use of diagnostic imaging to identify potential targets for quality improvement initiatives after adjusting for imaging referral across hospital referral regions (HRRs). MATERIALS AND METHODS:Using two Centers for Medicare and Medicaid Services datasets, the author...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.15141964

    authors: Ip IK,Raja AS,Seltzer SE,Gawande AA,Joynt KE,Khorasani R

    更新日期:2015-06-01 00:00:00

  • Cataract Risk in a Cohort of U.S. Radiologic Technologists Performing Nuclear Medicine Procedures.

    abstract::Purpose To estimate the risk of cataract in a cohort of nuclear medicine (NM) radiologic technologists on the basis of their work histories and radiation protection practices. Materials and Methods In the years 2003-2005 and 2012-2013, 42 545 radiologic technologists from a U.S. prospective study completed questionnai...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2017170683

    authors: Bernier MO,Journy N,Villoing D,Doody MM,Alexander BH,Linet MS,Kitahara CM

    更新日期:2018-02-01 00:00:00

  • Intravenous self-administration of metallic mercury.

    abstract::Embolization of metallic mercury is extremely rare. The literature has consisted primarily of scattered case reports. Two cases of patients with mercury embolization are presented. The differential diagnosis of the chest radiograph is discussed. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.137.2.7433660

    authors: Vas W,Tuttle RJ,Zylak CJ

    更新日期:1980-11-01 00:00:00

  • Dose efficiency of screen-film systems used in pediatric radiography.

    abstract::Twenty-one screen-film systems were examined using contrast-detail-dose methods in order to determine which were most dose-efficient for use in pediatric radiography. With a given screen, dose efficiency in the noise-limited region (contrast approximately equal to 0.05) was more or less constant (within the range of e...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.152.1.6729110

    authors: Cohen G,Wagner LK,McDaniel DL,Robinson LH

    更新日期:1984-07-01 00:00:00