Rapid clearance of advanced pelvic carcinomas by low dose rate 252Cf neutron therapy.

Abstract:

:Californium 252 low dose rate intracavitary neutron implants combined with conventional external beam therapy for advanced pelvic tumors produced better local response than 137Cs in pelvic brachytherapy. Greater tumor regression was achieved by applying 252Cf while the maximum amount of tumor was present preceding or shortly after starting external beam therapy (12/14 or 86%). This schedule was more effective than similar neutron doses given after external beam irradiation.

journal_name

Radiology

journal_title

Radiology

authors

Maruyama Y

doi

10.1148/133.2.473

subject

Has Abstract

pub_date

1979-11-01 00:00:00

pages

473-5

issue

2

eissn

0033-8419

issn

1527-1315

journal_volume

133

pub_type

杂志文章
  • Volumetric MR-guided high-intensity focused ultrasound ablation with a one-layer strategy to treat large uterine fibroids: initial clinical outcomes.

    abstract:PURPOSE:To evaluate initial clinical outcomes of volumetric magnetic resonance (MR)-guided high-intensity focused ultrasound (HIFU) ablation by using a one-layer strategy to treat large (>10 cm in diameter) uterine fibroids, with investigation of the correlation between effectiveness of the one-layer strategy and dynam...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.12111707

    authors: Kim YS,Kim JH,Rhim H,Lim HK,Keserci B,Bae DS,Kim BG,Lee JW,Kim TJ,Choi CH

    更新日期:2012-05-01 00:00:00

  • Kimray-Greenfield vena cava filter: percutaneous introduction.

    abstract::A percutaneous technique is described for the introduction of Kimray-Greenfield filters into the vena cava through either the internal jugular or femoral approach. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.151.2.6709930

    authors: Tadavarthy SM,Castaneda-Zuniga W,Salomonowitz E,Lund G,Cragg A,Hunter D,Coleman C,Amplatz K

    更新日期:1984-05-01 00:00:00

  • Value of selective second-look sonography by radiologists.

    abstract:PURPOSE:To assess the usefulness of sonography performed by radiologists after a review of the sonographer's findings. MATERIALS AND METHODS:A total of 398 sonograms were obtained in 392 patients. Sonographers presented preliminary images and impressions to radiologists, who performed additional imaging and recorded t...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.199.2.8668810

    authors: Tessler FN,Tublin ME,Peters JC,Jie T,Peters TL

    更新日期:1996-05-01 00:00:00

  • Short-limb skeletal dysplasias: evaluation of the fetal spine with sonography and radiography.

    abstract::Sonograms and radiographs of the lumbar spine in 51 fetuses and neonates with thanatophoric dwarfism, achondroplasia, and osteogenesis imperfecta type II were retrospectively evaluated. Study data included 27 prenatal and 27 neonatal sonograms and radiographs in 40 fetuses and neonates and 11 cases described in the ra...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.174.1.2403680

    authors: Rouse GA,Filly RA,Toomey F,Grube GL

    更新日期:1990-01-01 00:00:00

  • Björk-Shiley convexoconcave valves: susceptibility artifacts at brain MR imaging and mechanical valve fractures.

    abstract:PURPOSE:To assess the relationship between heart valve history and susceptibility artifacts at magnetic resonance (MR) imaging of the brain in patients with Björk-Shiley convexoconcave (BSCC) valves. MATERIALS AND METHODS:MR images of the brain were obtained in 58 patients with prosthetic heart valves: 20 patients had...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2303021619

    authors: van Gorp MJ,van der Graaf Y,de Mol BA,Bakker CJ,Witkamp TD,Ramos LM,Mali WP

    更新日期:2004-03-01 00:00:00

  • Nerve rootlet avulsion. A complication of myelography using the Chynn needle.

    abstract::The authors report a case of traumatic removal of nerve tissue during myelography with the Chynn aspiration cannula. If such a situation occurs, the authors suggest making a second puncture at a different level. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/125.3.734

    authors: Brodey PA,London SS,Sung MA

    更新日期:1977-12-01 00:00:00

  • Fibrin sealant in interventional radiology: a preliminary evaluation.

    abstract::Tisseel, a fibrin sealant not approved for use in the United States, was tested in abdominal fistulas and sinuses (13 patients) and interventional biliary procedures (11 patients). The two components of Tisseel were introduced via a double-lumen catheter and formed a fibrin gel at the point of contact. Tracts were sea...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.196.2.7617880

    authors: Brady AP,Malone DE,Deignan RW,O'Donovan N,McGrath FP

    更新日期:1995-08-01 00:00:00

  • Glass-Fiber-based MR-safe Guidewire for MR Imaging-guided Endovascular Interventions: In Vitro and Preclinical in Vivo Feasibility Study.

    abstract::Purpose To evaluate glass-fiber-based guidewires that are safe for magnetic resonance (MR) imaging-guided endovascular interventions by using a phantom and an in vivo swine model. Materials and Methods MR imaging-safe guidewires were made from micropultruded glass and/or aramid fibers and epoxy resin with diameters of...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2017152742

    authors: Massmann A,Buecker A,Schneider GK

    更新日期:2017-08-01 00:00:00

  • Complications of cesarean section: role of transperineal US.

    abstract::The pelvic area was prospectively examined with transabdominal and transperineal ultrasonography (US) in 22 patients referred for US evaluation for possible complications of cesarean section. The region of the uterine wound was seen with transabdominal US in all patients and with transperineal US in 20. The two in who...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.188.2.8327710

    authors: Hertzberg BS,Bowie JD,Kliewer MA

    更新日期:1993-08-01 00:00:00

  • Breast carcinoma: effect of preoperative contrast-enhanced MR imaging on the therapeutic approach.

    abstract:PURPOSE:To determine if magnetic resonance (MR) imaging can help determine the therapeutic approach in women with breast cancer. MATERIALS AND METHODS:Preoperative contrast-enhanced MR imaging of the breast was performed in 463 patients with probably benign lesions (n = 63), suspicious lesions (n = 230), or lesions hi...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.213.3.r99dc01881

    authors: Fischer U,Kopka L,Grabbe E

    更新日期:1999-12-01 00:00:00

  • Dedicated breast CT: radiation dose and image quality evaluation.

    abstract:PURPOSE:To evaluate the feasibility of breast computed tomography (CT) in terms of radiation dose and image quality. MATERIALS AND METHODS:Validated Monte Carlo simulation techniques were used to estimate the average glandular dose (AGD). The calculated photon fluence at the detector for high-quality abdominal CT (120...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2213010334

    authors: Boone JM,Nelson TR,Lindfors KK,Seibert JA

    更新日期:2001-12-01 00:00:00

  • Air cisternography of the cerebellopontine angle using high-resolution computed tomography.

    abstract::While high-resolution CT/air cisternography is considered the preferred method of investigating non-enhancing or small acoustic neuromas, it is not without pitfalls. Eighty such studies were reviewed, emphasizing procedural problems and sources of interpretive error. Two patients presented difficulty in transporting t...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.151.2.6608750

    authors: Johnson DW

    更新日期:1984-05-01 00:00:00

  • Pancreatic cystosis in cystic fibrosis.

    abstract::Two patients with cystic fibrosis and pancreatic cystosis are described who had complete replacement of the pancreas by multiple macroscopic cysts. The possible causes and clinical significance of this condition are discussed. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.158.3.3511500

    authors: Hernanz-Schulman M,Teele RL,Perez-Atayde A,Zollars L,Levine J,Black P,Kuligowska E

    更新日期:1986-03-01 00:00:00

  • PET/MR images acquired with a compact MR-compatible PET detector in a 7-T magnet.

    abstract:PURPOSE:To prospectively use compact avalanche photodiodes instead of photomultiplier tubes to integrate a positron emission tomographic (PET) detector and a 7-T magnetic resonance (MR) imager. MATERIALS AND METHODS:All animal experiments were performed in accordance with the University of Tübingen guidelines and the ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2443061756

    authors: Judenhofer MS,Catana C,Swann BK,Siegel SB,Jung WI,Nutt RE,Cherry SR,Claussen CD,Pichler BJ

    更新日期:2007-09-01 00:00:00

  • Early familial dilated cardiomyopathy: identification with determination of disease state parameter from cine MR image data.

    abstract:PURPOSE:To characterize early changes in cardiac anatomy and function for lamin A/C gene (LMNA) mutation carriers by using magnetic resonance (MR) imaging and to develop tools to analyze and visualize the findings. MATERIALS AND METHODS:The ethical review board of the institution approved the study, and informed writt...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2491071584

    authors: Koikkalainen JR,Antila M,Lötjönen JM,Heliö T,Lauerma K,Kivistö SM,Sipola P,Kaartinen MA,Kärkkäinen ST,Reissell E,Kuusisto J,Laakso M,Oresic M,Nieminen MS,Peuhkurinen KJ

    更新日期:2008-10-01 00:00:00

  • Anomalies of the intrahepatic portal venous system in congenital hepatic fibrosis.

    abstract::Duplication of intrahepatic venous channels was observed in 9 of 13 children with congenital hepatic fibrosis and portal hypertension. Portal hypertension due to other causes was not associated with venous duplication. This anomaly may be a distinctive feature of congenital hepatic fibrosis with portal hypertension. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/122.2.427

    authors: Odievre M,Chaumont P,Montagne JP,Alagille D

    更新日期:1977-02-01 00:00:00

  • Pleural telangiectasia and absence of a pulmonary artery.

    abstract::The radiological features of absence of a pulmonary artery are often characteristic enough to allow a diagnosis based on the plain radiograph. They include a small hemithorax, ipsilateral displacement of the mediastinum, absence of the corresponding pulmonary artery, and reticular parenchymal densities, generally attr...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/132.2.281

    authors: Kleinman PK

    更新日期:1979-08-01 00:00:00

  • Sellar and juxtasellar lesion detection with MR.

    abstract::We compared the effectiveness of magnetic resonance (MR) imaging and computed tomography (CT) in evaluating sellar and juxtasellar lesions. Fifty-five lesions were imaged with a Technicare 0.5-T superconducting MR imager and GE 9800 and 8800 CT scanners: 26 pituitary adenomas (including six microadenomas), six craniop...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.157.1.4034960

    authors: Lee BC,Deck MD

    更新日期:1985-10-01 00:00:00

  • Microwave ablation with multiple simultaneously powered small-gauge triaxial antennas: results from an in vivo swine liver model.

    abstract:PURPOSE:To prospectively investigate the ability of a single generator to power multiple small-diameter antennas and create large zones of ablation in an in vivo swine liver model. MATERIALS AND METHODS:Thirteen female domestic swine (mean weight, 70 kg) were used for the study as approved by the animal care and use c...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2441052054

    authors: Brace CL,Laeseke PF,Sampson LA,Frey TM,van der Weide DW,Lee FT Jr

    更新日期:2007-07-01 00:00:00

  • A modular computer system for the nuclear medicine/ultrasound laboratory.

    abstract::Computer-controlled graphic displays are a necessity in many nuclear medicine studies. The authors propose using a set-up consisting of three modules: (a) a display system based on television technology; (b) an instrument interface employing list mode and having a low information loss rate; and (c) flexible modular so...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/124.3.759

    authors: Noz ME,Schimpf JH,Maguire GQ Jr

    更新日期:1977-09-01 00:00:00

  • Traumatic disruption of the thoracic aorta: significance of the left apical extrapleural cap.

    abstract::The plain chest film may be critical in deciding whether a seriously injured patient should undergo aortography in order to exclude traumatic aortic rupture. The roentgen findings suggestive of aortic transection reflect the presence of mediastinal bleeding. A left apical extrapleural cap is frequently seen in these p...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/117.2.265

    authors: Simeone JF,Minagi H,Putman CE

    更新日期:1975-11-01 00:00:00

  • Deep vein thrombosis of lower extremity: direct intraclot injection of alteplase once daily with systemic anticoagulation--results of pilot study.

    abstract:PURPOSE:To prospectively evaluate the outcome of patients with acute deep vein thrombosis (DVT) of the lower extremity treated with "lacing" of the thrombus with alteplase (recombinant tissue plasminogen activator, or rTPA). MATERIALS AND METHODS:This HIPAA-compliant study was approved by the Institutional Review Boar...

    journal_title:Radiology

    pub_type: 临床试验,杂志文章

    doi:10.1148/radiol.2461062076

    authors: Chang R,Chen CC,Kam A,Mao E,Shawker TH,Horne MK 3rd

    更新日期:2008-02-01 00:00:00

  • The energy-dependent behavior of noise Wiener spectra in their low-frequency limits: comparison with simple theory.

    abstract::The Wiener spectra of five screen-film systems were studied as a function of monoenergetic x-ray energy. These spectra, in their low-frequency limits, were seen to depend linearly on x-ray energy. The Wiener spectra also decreased in magnitude as the incident x-ray energy exceeded that of the screen phosphor K absorpt...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.144.3.7100480

    authors: Vyborny CJ,Loo LN,Doi K

    更新日期:1982-08-01 00:00:00

  • What the diagnostic radiologist needs to know about radiation oncology.

    abstract::Substantial technologic advances in radiation treatment planning and delivery have made possible exquisite tailoring of three-dimensional radiation dose distributions that conform to the tumor treatment volume while avoiding adjacent normal tissues. Although such highly precise treatment can increase the therapeutic r...

    journal_title:Radiology

    pub_type: 杂志文章,评审

    doi:10.1148/radiol.11101688

    authors: Terezakis SA,Heron DE,Lavigne RF,Diehn M,Loo BW Jr

    更新日期:2011-10-01 00:00:00

  • Chronic portosystemic encephalopathy: embolization of portosystemic shunts.

    abstract::Operative ligation of portosystemic shunts is effective in controlling chronic portosystemic encephalopathy (CPSE) but is associated with significant mortality. Review of the records of five patients with CPSE treated with radiologic occlusion procedures showed that these are suitable alternatives to surgery. Three pa...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.165.3.3685350

    authors: Uflacker R,Silva Ade O,d'Albuquerque LA,Piske RL,Mourão GS

    更新日期:1987-12-01 00:00:00

  • Colorectal cancer overlooked at barium enema examination and colonoscopy: a continuing perceptual problem.

    abstract:PURPOSE:To evaluate reasons for missed diagnosis of colorectal carcinoma at barium enema (BE) examination and colonoscopy and determine if standards have improved since a similar study in 1981. MATERIALS AND METHODS:Relevant studies obtained within 3 years of diagnosis in 161 patients with colorectal carcinoma treated...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.192.2.8029400

    authors: Brady AP,Stevenson GW,Stevenson I

    更新日期:1994-08-01 00:00:00

  • Pilonidal sinus disease: MR imaging distinction from fistula in ano.

    abstract:PURPOSE:To describe magnetic resonance (MR) imaging features in patients with proved pilonidal sinus disease and to compare these features with those in a matched group of patients with proved fistula in ano to determine the accuracy with which MR imaging can be used to distinguish between the two diseases. MATERIALS ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2263011758

    authors: Taylor SA,Halligan S,Bartram CI

    更新日期:2003-03-01 00:00:00

  • Preeclampsia-eclampsia: clinical and neuroradiographic correlates and insights into the pathogenesis of hypertensive encephalopathy.

    abstract:PURPOSE:To investigate the clinical parameters that are associated with the development of brain edema of hypertensive encephalopathy in patients with preeclampsia-eclampsia. MATERIALS AND METHODS:Twenty-eight patients with preeclampsia-eclampsia and neurologic symptoms underwent magnetic resonance (MR) imaging. Clini...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.217.2.r00nv44371

    authors: Schwartz RB,Feske SK,Polak JF,DeGirolami U,Iaia A,Beckner KM,Bravo SM,Klufas RA,Chai RY,Repke JT

    更新日期:2000-11-01 00:00:00

  • The validity of criteria for the evaluation of cerebral atrophy by computed tomography.

    abstract::Computed tomography of the brain was used in evaluating demented and nondemented elderly people. The incidence of convulutional atrophy and ventricular enlargement correlated well with pathologic and pneumoencephalographic examination of a similar population. Computed tomography also showed certain instances of dement...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/116.1.85

    authors: Huckman MS,Fox J,Topel J

    更新日期:1975-07-01 00:00:00

  • Temporomandibular joint: magnetic resonance imaging.

    abstract::Magnetic resonance (MR) imaging of the temporomandibular joint was performed in two subjects using a 1.5 T experimental imaging system equipped with a 6.5 cm surface coil antenna. Normal and pathologic anatomy were demonstrated with exquisite detail. Anterior displacement of the joint meniscus was clearly visible in t...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.154.3.3969490

    authors: Roberts D,Schenck J,Joseph P,Foster T,Hart H,Pettigrew J,Kundel HL,Edelstein W,Haber B

    更新日期:1985-03-01 00:00:00