Volumetric MR-guided high-intensity focused ultrasound ablation with a one-layer strategy to treat large uterine fibroids: initial clinical outcomes.

Abstract:

PURPOSE:To evaluate initial clinical outcomes of volumetric magnetic resonance (MR)-guided high-intensity focused ultrasound (HIFU) ablation by using a one-layer strategy to treat large (>10 cm in diameter) uterine fibroids, with investigation of the correlation between effectiveness of the one-layer strategy and dynamic contrast material-enhanced (DCE) MR parameters. MATERIALS AND METHODS:Institutional review board approval and informed consent were obtained. Twenty-seven women (mean age, 44.5 years) with 27 large uterine fibroids (mean diameter, 11.3 cm ± 1.4 [standard deviation] [range, 10.1-16.0 cm]; fibroid volume, 502.5 mL ± 214.3 [range, 253.8-1184.0 mL]) underwent volumetric MR-guided HIFU ablation with a one-layer strategy. (All treatment cells were placed in one coronal plane at a depth of half to anterior two-thirds of the anteroposterior dimension of fibroids.) Treatment time, immediate nonperfused volume (NPV), and effectiveness of a one-layer strategy (ratio of immediate NPV to total volume of treatment cells planned) correlating with baseline DCE MR parameters (volume transfer constant [K(trans)], fractional extravascular extracellular space, and fractional blood plasma volume [Pearson correlation test]), complications, 3-month follow-up volumes, and symptom severity score (SSS) changes (paired t test) were assessed retrospectively. RESULTS:All treatments showed technical success in one session (mean treatment time, 166.2 minutes ± 38.9). NPV was 301.3 mL ± 119.1, which was 64.2% ± 19.9 (<50%, n = 4; ≥ 50%, n = 23) of fibroid volume. Ratio of immediate NPV to total volume of treatment cells (1.79 ± 0.61) negatively correlated with DCE MR imaging K(trans) values (r = -0.426, P = .017). Minor complications occurred in five patients (18.5% [thermal injury of abdominal wall, n = 3; 30-day leg numbness, n = 1; cystitis, n = 1]). At 3-month follow-up (n = 18), mean SSS had decreased from 37.4 at baseline to 24.0 (P < .001), and volume reduction ratio was 0.64 ± 0.15 (P < .001). CONCLUSION:Volumetric MR-guided HIFU ablation with a one-layer strategy is safe and effective for treatment of large uterine fibroids. Effectiveness of this strategy showed a significant negative correlation with K(trans) values at baseline DCE MR imaging.

journal_name

Radiology

journal_title

Radiology

authors

Kim YS,Kim JH,Rhim H,Lim HK,Keserci B,Bae DS,Kim BG,Lee JW,Kim TJ,Choi CH

doi

10.1148/radiol.12111707

subject

Has Abstract

pub_date

2012-05-01 00:00:00

pages

600-9

issue

2

eissn

0033-8419

issn

1527-1315

pii

radiol.12111707

journal_volume

263

pub_type

杂志文章
  • Focal liver tumors: characterization with 3D perflubutane microbubble contrast agent-enhanced US versus 3D contrast-enhanced multidetector CT.

    abstract:PURPOSE:To investigate the potential application of contrast material-enhanced three-dimensional (3D) ultrasonography (US), as compared with contrast-enhanced 3D computed tomography (CT), for characterization of focal liver tumors. MATERIALS AND METHODS:Institutional review board approval and informed patient consent ...

    journal_title:Radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1148/radiol.2511081324

    authors: Luo W,Numata K,Morimoto M,Kondo M,Takebayashi S,Okada M,Morita S,Tanaka K

    更新日期:2009-04-01 00:00:00

  • Ferromagnetic materials in patients: detection before MR imaging.

    abstract::A number of surgical clips and other metallic materials embedded within patients have ferromagnetic properties that present a potential hazard when in the strong fields associated with magnetic resonance imaging. Several types of magnetometers and metal detectors were investigated as possible pre-imaging screening dev...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.156.1.4001400

    authors: Finn EJ,Di Chiro G,Brooks RA,Sato S

    更新日期:1985-07-01 00:00:00

  • Spiral CT of the pancreas.

    abstract::Computed tomography (CT) is the modality of choice for evaluation of pancreatic disease. In this prospective study, images obtained with spiral CT, which enables examination of a region of the body in a single breath-hold, were compared with those obtained by means of dynamic CT with automatic table incrementation in ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.183.3.1584940

    authors: Dupuy DE,Costello P,Ecker CP

    更新日期:1992-06-01 00:00:00

  • Hemobilia following transhepatic biliary drainage: occlusion of an hepatoportal fistula by balloon tamponade.

    abstract::Acute clinically significant hemobilia occurred after percutaneous transhepatic biliary drainage. Investigations revealed a fistula between a peripheral bile duct and a branch of the portal vein. Hemostasis was obtained by balloon tamponade at the site of the fistula. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.154.3.3155870

    authors: Sniderman KW,Morse SS,Rapoport S,Ross GR

    更新日期:1985-03-01 00:00:00

  • Liver SULmean at FDG PET/CT: interreader agreement and impact of placement of volume of interest.

    abstract:PURPOSE:To evaluate how interreader agreement and the site of the volume of interest (VOI) affect the agreement and variability of liver mean standardized uptake value normalized to lean body mass (SUL(mean)) at fluorine 18 fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT). MATERIALS...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.12121385

    authors: Viner M,Mercier G,Hao F,Malladi A,Subramaniam RM

    更新日期:2013-05-01 00:00:00

  • Computers in radiology. A question of compatibility.

    abstract::Given the increasing diversification of computers in most areas of radiology, the ability to solve problems resulting from incompatibility between systems is becoming essential. Manufacturers should supply hardware and software documentation to allow connections between different systems and give the radiology departm...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.139.2.7220900

    authors: Ackerman LV

    更新日期:1981-05-01 00:00:00

  • Impassable ureteral strictures: management with percutaneous ureteroneocystostomy.

    abstract::Sixteen of 227 patients referred for percutaneous placement of a ureteral stent had impassable stenoses. Stenoses were benign (n = 8) or attributed to malignant retroperitoneal neoplasm (n = 8). Electrocautery was used to create a neotract between the stenosed ureter and the bladder or ileal loop. A double-J stent was...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.180.2.2068310

    authors: Cornud FE,Casanova JM,Bonnel DH,Helenon OR,Hanna SM,Chretien YR,Dufour BF,Moreau JF

    更新日期:1991-08-01 00:00:00

  • Focal organizing pneumonia: CT appearance.

    abstract:PURPOSE:To clarify the computed tomographic (CT) features of focal organizing pneumonia. MATERIALS AND METHODS:The authors retrospectively studied CT scans of 18 patients with histologically proved focal organizing pneumonia. Chest radiographs in all 18 patients suggested bronchogenic carcinoma. RESULTS:Seventeen of ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.189.1.8372180

    authors: Kohno N,Ikezoe J,Johkoh T,Takeuchi N,Tomiyama N,Kido S,Kondoh H,Arisawa J,Kozuka T

    更新日期:1993-10-01 00:00:00

  • Credentialing of crossover privileges in fluoroscopy for nonradiologists.

    abstract:PURPOSE:To comply with federal and state guidelines, a credentialing process was developed for nonradiologist medical users of fluoroscopy. MATERIALS AND METHODS:Seventy-three nonradiologist physicians participated in a program consisting of (a) an introductory 1-hour lecture; (b) a 10-page booklet providing basic inf...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.190.1.8259420

    authors: Swayne LC,Lam SC,Filippone AL,Ambrose RB

    更新日期:1994-01-01 00:00:00

  • Myocardial bridging: depiction rate and morphology at CT coronary angiography--comparison with conventional coronary angiography.

    abstract:PURPOSE:To prospectively assess the depiction rate and morphologic features of myocardial bridging (MB) of coronary arteries with 64-section computed tomographic (CT) coronary angiography in comparison to conventional coronary angiography. MATERIALS AND METHODS:Patients were simultaneously enrolled in a prospective st...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2463062071

    authors: Leschka S,Koepfli P,Husmann L,Plass A,Vachenauer R,Gaemperli O,Schepis T,Genoni M,Marincek B,Eberli FR,Kaufmann PA,Alkadhi H

    更新日期:2008-03-01 00:00:00

  • Appendicitis: efficacy of color Doppler sonography.

    abstract:PURPOSE:To determine whether the addition of color Doppler ultrasonography (US) to gray-scale US can help diagnose appendicitis in children. MATERIALS AND METHODS:One hundred children with suspected appendicitis were evaluated with gray-scale and color Doppler US scanning. Color Doppler US scans were considered positi...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.191.2.8153340

    authors: Quillin SP,Siegel MJ

    更新日期:1994-05-01 00:00:00

  • Healing of lytic Paget bone disease with diphosphonate therapy.

    abstract::In a patient with Paget disease, two of three lytic fronts ("blade-of-grass" lesions) healed according to radiologic criteria during intermittent diphosphonate therapy. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.134.3.7355210

    authors: Murphy WA,Whyte MP,Haddad JG Jr

    更新日期:1980-03-01 00:00:00

  • Detection of Steatohepatitis in a Rat Model by Using Spectroscopic Shear-Wave US Elastography.

    abstract::Purpose To compare low- versus high-frequency ultrasonographic (US) elastography for detection of steatohepatitis in rats by using histopathologic findings as the reference standard. Materials and Methods Between March and September 2014, after receiving approval from the institutional animal care committee, 60 male S...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2016160308

    authors: Kazemirad S,Zhang E,Nguyen BN,Bodson-Clermont P,Destrempes F,Trudel D,Cloutier G,Tang A

    更新日期:2017-03-01 00:00:00

  • Retrievable vena caval filter percutaneously introduced.

    abstract::A vena caval filter than can be introduced percutaneously via the femoral vein is described. We placed these filters in five patients without complications. Experimental work in filter removal one to two weeks after insertion in dogs has been performed. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.155.3.4001390

    authors: Lund G,Rysavy J,Hunter DW,Castaneda-Zuniga WR,Amplatz K

    更新日期:1985-06-01 00:00:00

  • Coronary MR angiography with steady-state free precession: individually adapted breath-hold technique versus free-breathing technique.

    abstract:PURPOSE:To compare image quality and coronary artery stenosis detection with breath-hold (BH) and free-breathing navigator-gated (NAV) coronary magnetic resonance (MR) angiography performed with the same imaging sequence (steady-state free precession) and identical spatial resolution in patients suspected of having cor...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2323031225

    authors: Jahnke C,Paetsch I,Schnackenburg B,Bornstedt A,Gebker R,Fleck E,Nagel E

    更新日期:2004-09-01 00:00:00

  • Technique factors and image quality as functions of patient weight at abdominal CT.

    abstract:PURPOSE:To investigate how changes in kilovolt peak and milliampere second settings, and patient weight affect transmitted x-ray energy fluence and the image contrast-to-noise ratio (CNR) at abdominal computed tomography (CT). MATERIALS AND METHODS:Cylinders of water were used as patient models, and x-ray spectra, inc...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.217.2.r00nv35430

    authors: Huda W,Scalzetti EM,Levin G

    更新日期:2000-11-01 00:00:00

  • Dynamic Contrast-enhanced MR Imaging of Advanced Hepatocellular Carcinoma: Comparison with the Liver Parenchyma and Correlation with the Survival of Patients Receiving Systemic Therapy.

    abstract::Purpose To retrospectively compare the perfusion parameters of advanced hepatocellular carcinoma (HCC) measured with dynamic contrast material-enhanced (DCE) magnetic resonance (MR) imaging with surrounding liver parenchyma to determine the relationship between these parameters and uncensored overall survival (OS). Ma...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2016152659

    authors: Chen BB,Hsu CY,Yu CW,Liang PC,Hsu C,Hsu CH,Cheng AL,Shih TT

    更新日期:2016-11-01 00:00:00

  • Malignant gastrointestinal stromal tumor: distribution, imaging features, and pattern of metastatic spread.

    abstract:PURPOSE:To investigate and describe the anatomic distribution, imaging features, and pattern of metastatic spread of malignant gastrointestinal stromal tumors (GISTs). MATERIALS AND METHODS:The medical records of all patients at our institution with a histologic diagnosis of GIST were reviewed. Two radiologists with k...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2262011880

    authors: Burkill GJ,Badran M,Al-Muderis O,Meirion Thomas J,Judson IR,Fisher C,Moskovic EC

    更新日期:2003-02-01 00:00:00

  • Releif of severe fecal impactions with water-soluble contrast enemas.

    abstract::High fecal impaction resulted in complete bowel obstruction in 2 children following renal transplantation and in one adult on chemotherapy and narcotics. The usual methods of relief failed, and water-soluble contrast enemas with a high osmolality were employed. Fluoroscopic control assured placement of the enema fluid...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/115.1.9

    authors: Culp WC

    更新日期:1975-04-01 00:00:00

  • Liver diffusion-weighted MR imaging: reproducibility comparison of ADC measurements obtained with multiple breath-hold, free-breathing, respiratory-triggered, and navigator-triggered techniques.

    abstract:PURPOSE:To prospectively compare the reproducibility of normal liver apparent diffusion coefficient (ADC) measurements by using different respiratory motion compensation techniques with multiple breath-hold (MBH), free-breathing (FB), respiratory-triggered (RT), and navigator-triggered (NT) diffusion-weighted (DW) imag...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.13131572

    authors: Chen X,Qin L,Pan D,Huang Y,Yan L,Wang G,Liu Y,Liang C,Liu Z

    更新日期:2014-04-01 00:00:00

  • Minimizing central bile duct injury during radiofrequency ablation: use of intraductal chilled saline perfusion--initial observations from a study in pigs.

    abstract:PURPOSE:To determine whether intraductal perfusion with chilled saline reduces thermal injury to bile ducts during radiofrequency (RF) ablation. MATERIALS AND METHODS:In swine, anesthesia was induced and the common bile duct was surgically cannulated with a pediatric feeding tube. RF thermal lesions were created adjac...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2321030210

    authors: Raman SS,Aziz D,Chang X,Ye M,Sayre J,Lassman C,Lu DS

    更新日期:2004-07-01 00:00:00

  • Bowel and mesenteric injury following blunt abdominal trauma: evaluation with CT.

    abstract::Computed tomography (CT) used in cases of blunt abdominal trauma has been found sensitive in detection of bowel and mesenteric injuries and discrimination of operable from nonoperable candidates. In 51 patients with suspected bowel or mesenteric injury following blunt abdominal trauma, CT correctly depicted bowel hema...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.173.1.2781000

    authors: Rizzo MJ,Federle MP,Griffiths BG

    更新日期:1989-10-01 00:00:00

  • Laparoscopic gray-scale and color Doppler US: preliminary animal and clinical studies.

    abstract:PURPOSE:To evaluate a semiflexible ultrasound (US) transducer inserted through a laparoscopic port to image abdominal structures. MATERIALS AND METHODS:Laparoscopic US with a 9.6-mm-diameter, 5.0-7.5-MHz semiflexible transducer with gray-scale, color, and spectral Doppler capabilities was performed in three miniature ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.194.3.7862990

    authors: Liu JB,Feld RI,Goldberg BB,Barbot DJ,Nazarian LN,Merton DA,Rawool NM,Rosato FE,Winkel CA,Gillum DR

    更新日期:1995-03-01 00:00:00

  • Ventilator-associated Pseudomonas aeruginosa pneumonia: radiographic findings.

    abstract:PURPOSE:To characterize the radiographic features of ventilator-associated Pseudomonas aeruginosa pneumonia (PAP). MATERIALS AND METHODS:In 56 patients (40 men and 16 women), PAP was documented with fiberoptic bronchoscopy. All patients underwent mechanical ventilation for at least 48 hours before diagnosis. The findi...

    journal_title:Radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1148/radiology.195.1.7892480

    authors: Winer-Muram HT,Jennings SG,Wunderink RG,Jones CB,Leeper KV Jr

    更新日期:1995-04-01 00:00:00

  • Acute-phase response after stent implantation in the carotid artery: association with 6-month in-stent restenosis.

    abstract:PURPOSE:To determine the prognostic importance of periintervention serum levels of acute-phase reactants in 6-month restenosis after stent implantation in the carotid artery. MATERIALS AND METHODS:One hundred eight consecutive patients with 70% or greater stenosis of the internal carotid artery (ICA) according to the ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2272020183

    authors: Schillinger M,Exner M,Mlekusch W,Rumpold H,Ahmadi R,Sabeti S,Lang W,Wagner O,Minar E

    更新日期:2003-05-01 00:00:00

  • Prostaglandin E1 as a pharmacoangiographic agent for arterial portography.

    abstract::The effects of increasing single selective doses of prostaglandin E1 (PGE1) on superior mesenteric arterial flow and portal and systemic blood pressures were studied in dogs to assess its value as a vasodilatory agent for pharmacoangiography. PGE1 consistently increased blood flow, with an average increase of 187%, bu...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/116.1.207

    authors: Cho KJ,Chuang VP,Reuter SR

    更新日期:1975-07-01 00:00:00

  • New techniques in lumbar spinal instrumentation: what the radiologist needs to know.

    abstract::Lumbar spinal fusion is a commonly performed procedure, and, despite changes in cage types and fixation hardware, radiologists have, over the years, become familiar with the imaging features of typical spinal fusion and many of the complications seen in patients after surgery, including pseudoarthrosis, hardware loose...

    journal_title:Radiology

    pub_type: 杂志文章,评审

    doi:10.1148/radiol.11101104

    authors: Murtagh RD,Quencer RM,Castellvi AE,Yue JJ

    更新日期:2011-08-01 00:00:00

  • Existence of the diffusion-perfusion mismatch within 24 hours after onset of acute stroke: dependence on proximal arterial occlusion.

    abstract:PURPOSE:To assess the existence of a mismatch between lesions on diffusion-weighted (DW) and perfusion-weighted (PW) magnetic resonance (MR) images obtained within 24 hours after onset of acute stroke and to use mismatch data and angiographic evidence of proximal arterial occlusion (PAO) to investigate whether the exis...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2503080811

    authors: Copen WA,Rezai Gharai L,Barak ER,Schwamm LH,Wu O,Kamalian S,Gonzalez RG,Schaefer PW

    更新日期:2009-03-01 00:00:00

  • Use of a gradient intensifying screen for scoliosis radiography.

    abstract::A gradient intensifying screen composed of rare earth phosphors and calcium tungstate was developed. It provides uniform film density when there is a graded increase in subject density. Use of this screen for scoliosis radiography provides an improved image and reduces radiation exposure. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.135.1.7360970

    authors: Ritter EM,Wright CE,Fritz SL,Kirchmer NA,De Smet AA

    更新日期:1980-04-01 00:00:00

  • Systemic-to-pulmonary collateral vessels and shunts: treatment with embolization.

    abstract::Abnormal collateral vessels develop frequently in patients with right ventricular outflow or pulmonary artery obstruction. Surgery is usually used to obliterate these vessels but may be difficult, involve prolonged operative time, or require a different thoracotomy than that used for correction or palliation of the ca...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.169.3.3186990

    authors: Lois JF,Gomes AS,Smith DC,Laks H

    更新日期:1988-12-01 00:00:00