Analysis of the biomechanical behaviour of gastrointestinal regions adopting an experimental and computational approach.

Abstract:

:An integrated experimental and computational procedure is provided for the evaluation of the biomechanical behaviour that characterizes the pressure-volume response of gastrointestinal regions. The experimental activity pertains to inflation tests performed on specific gastrointestinal conduct segments. Different inflation processes are performed according to progressively increasing volumes. Each inflation test is performed by a rapid liquid in-flaw, up to a prescribed volume, which is held constant for about 300s to allow the development of relaxation processes. The different tests are interspersed by 600s of rest to allow the recovery of the specimen mechanical condition. A physio-mechanical model is developed to interpret both the elastic behaviour of the sample, as the pressure-volume trend during the rapid liquid in-flaw, and the time-dependent response, as the pressure drop during the relaxation processes. The minimization of discrepancy between experimental data and model results entails the identification of the parameters that characterize the viscoelastic model adopted for the definition of the behaviour of the gastrointestinal regions. The reliability of the procedure is assessed by the characterization of the response of samples from rat small intestine.

authors

Carniel EL,Rubini A,Frigo A,Natali AN

doi

10.1016/j.cmpb.2013.06.022

subject

Has Abstract

pub_date

2014-01-01 00:00:00

pages

338-45

issue

1

eissn

0169-2607

issn

1872-7565

pii

S0169-2607(13)00301-5

journal_volume

113

pub_type

杂志文章
  • Computer tool to evaluate the cue reactivity of chemically dependent individuals.

    abstract:BACKGROUND AND OBJECTIVE:Anxiety is one of the major influences on the dropout of relapse and treatment of substance abuse treatment. Chemically dependent individuals need (CDI) to be aware of their emotional state in situations of risk during their treatment. Many patients do not agree with the diagnosis of the therap...

    journal_title:Computer methods and programs in biomedicine

    pub_type: 杂志文章

    doi:10.1016/j.cmpb.2016.11.014

    authors: Silva MLD,Frère AF,Oliveira HJQ,Martucci Neto H,Scardovelli TA

    更新日期:2017-03-01 00:00:00

  • IT-based evaluation and automatic improvement of the quality of intraoral radiographs.

    abstract::The quality of intraoral radiographs made in dental practices is too often not adequate for diagnostic purposes. This necessitates standardized measures for the quality of intraoral radiographs and controlled techniques for automatic image improvement. For the evaluation of the quality of digitized intraoral radiograp...

    journal_title:Computer methods and programs in biomedicine

    pub_type: 杂志文章

    doi:10.1016/0169-2607(94)01597-9

    authors: Koch S,Wagner IV,Seipel S,Schneider W

    更新日期:1995-01-01 00:00:00

  • A review of thresholding strategies applied to human chromosome segmentation.

    abstract::Karyotype analysis is a widespread procedure in cytogenetics to assess the presence of genetic defects by the visualization of the structure of chromosomes. The procedure is lengthy and repetitive and an effective automatic analysis would greatly help the cytogeneticist routine work. Still, automatic segmentation and ...

    journal_title:Computer methods and programs in biomedicine

    pub_type: 杂志文章,评审

    doi:10.1016/j.cmpb.2011.12.003

    authors: Poletti E,Zappelli F,Ruggeri A,Grisan E

    更新日期:2012-11-01 00:00:00

  • A software for the description of workplaces in the PRS system.

    abstract::Workplace description is an operation indispensable for the identification of professional risks and, in fulfillment of that objective, can best be accomplished by listing the constituent tasks associated with each job. This article presents a software in Visual-Basic to be run on a portable micro-computer, which faci...

    journal_title:Computer methods and programs in biomedicine

    pub_type: 杂志文章

    doi:10.1016/s0169-2607(97)01777-x

    authors: Martin JM,Dartois E,Bontoux-Frank G,Ricour B,Pariset L,Robaux P,Giampietro V

    更新日期:1997-01-01 00:00:00

  • Image analysis and synthesis of multimodal images in medicine.

    abstract::Radiologic and clinical practice can be enhanced by improved access to multimodal image information. Analysis, visualization, method characteristic image processing and image synthesis is needed not only for the interpretation of the images but also for performing effective consultations with clinical colleagues and c...

    journal_title:Computer methods and programs in biomedicine

    pub_type: 杂志文章

    doi:10.1016/0169-2607(94)90070-1

    authors: Englmeier KH,Haubner M,Fink U,Fink B

    更新日期:1994-06-01 00:00:00

  • A tracer metric numerical model for predicting tortuosity factors in three-dimensional porous tissue scaffolds.

    abstract::One of the critical functions of a tissue-engineered construct is to be able to provide adequate nutrient and oxygen supply into the interior of the construct. An insufficient supply will lead to slower cellular proliferation rates and eventual apoptosis. The supply of the nutrients is largely governed by the transpor...

    journal_title:Computer methods and programs in biomedicine

    pub_type: 杂志文章

    doi:10.1016/j.cmpb.2007.04.003

    authors: Starly B,Yildirim E,Sun W

    更新日期:2007-07-01 00:00:00

  • Thomas: building Bayesian statistical expert systems to aid in clinical decision making.

    abstract::Knowledge-based system for classical statistical analysis must separate the task of analyzing data from that of using the results of the analysis. In contrast, a Bayesian framework for building biostatistical expert system allows for the integration of the data-analytic and decision-making tasks. The architecture of s...

    journal_title:Computer methods and programs in biomedicine

    pub_type: 杂志文章

    doi:10.1016/0169-2607(91)90003-c

    authors: Lehmann HP,Shortliffe EH

    更新日期:1991-08-01 00:00:00

  • Lung tumor segmentation in PET images using graph cuts.

    abstract::The aim of segmentation of tumor regions in positron emission tomography (PET) is to provide more accurate measurements of tumor size and extension into adjacent structures, than is possible with visual assessment alone and hence improve patient management decisions. We propose a segmentation energy function for the g...

    journal_title:Computer methods and programs in biomedicine

    pub_type: 杂志文章

    doi:10.1016/j.cmpb.2012.10.009

    authors: Ballangan C,Wang X,Fulham M,Eberl S,Feng DD

    更新日期:2013-03-01 00:00:00

  • Finite element analysis of torque induced orthodontic bracket slot deformation in various bracket-archwire contact assembly.

    abstract:BACKGROUND AND OBJECTIVES:Orthodontic fixed appliance therapy involves alignment of teeth through the bracket and archwires. The archwire twist (torque) imparts significant forces inside the bracket slot in refining the teeth position at the end of treatment. The objective of this in- silico study was to evaluate the t...

    journal_title:Computer methods and programs in biomedicine

    pub_type: 杂志文章

    doi:10.1016/j.cmpb.2020.105748

    authors: Harikrishnan P,Magesh V,Ajayan AM,JebaSingh DK

    更新日期:2020-12-01 00:00:00

  • Assessment of auditory threshold using Multiple Magnitude-Squared Coherence and amplitude modulated tones monaural stimulation around 40 Hz.

    abstract:BACKGROUND AND OBJECTIVE:The use of objective detection techniques applied to the auditory steady-state responses (ASSRs) for the assessment of auditory thresholds has been investigated over the years. The idea consists in setting up the audiometric profile without subjective inference from patients and evaluators. The...

    journal_title:Computer methods and programs in biomedicine

    pub_type: 杂志文章

    doi:10.1016/j.cmpb.2018.01.031

    authors: Silva GM,Antunes F,Henrique CS,Felix LB

    更新日期:2018-06-01 00:00:00

  • Bulk modulus and volume variation measurement of the liver and the kidneys in vivo using abdominal kinetics during free breathing.

    abstract::This article presents a method of predictive simulation, patient-dependant, in real time of the abdominal organ positions during free breathing. The method, that considers both influence of the abdominal breathing and thoracic breathing, needs a tracking of the patient skin and a model of the patient-specific modifica...

    journal_title:Computer methods and programs in biomedicine

    pub_type: 杂志文章

    doi:10.1016/j.cmpb.2010.03.003

    authors: Hostettler A,George D,Rémond Y,Nicolau SA,Soler L,Marescaux J

    更新日期:2010-11-01 00:00:00

  • Monte Carlo simulation of latanoprost induced iris darkening.

    abstract::The aim of this study was to provide numerical evidence that latanoprost induced iris darkening (LIID) can be caused by changes to the melanin granule size distribution in the anterior segment of the iris. Iridectomies from two patients were used, where both had undergone unilateral treatment with latanoprost and had ...

    journal_title:Computer methods and programs in biomedicine

    pub_type: 杂志文章

    doi:10.1016/j.cmpb.2007.04.010

    authors: Cracknell KP,Farnell DJ,Grierson I

    更新日期:2007-08-01 00:00:00

  • BB_RADABA: a computer program as a tool for breeding and management of laboratory animals.

    abstract::The use of well characterized laboratory animals in biomedical research is of importance for quality securing and reproducibility of animal experiments. Therefore, breeders should not only have in mind the reproduction of their animal stocks, but they should also be interested to achieve an optimal resemblance of the ...

    journal_title:Computer methods and programs in biomedicine

    pub_type: 杂志文章

    doi:10.1016/0169-2607(92)90076-j

    authors: Vogt L,Klöting I

    更新日期:1992-06-01 00:00:00

  • The MISCAN simulation program for the evaluation of screening for disease.

    abstract::The computer program MISCAN is developed for use in evaluation of mass screening for disease. The program uses Monte Carlo simulation. It produces output on the results of screening projects and on the effects of screening on morbidity and mortality on the individual and population level. The calculations are based on...

    journal_title:Computer methods and programs in biomedicine

    pub_type: 杂志文章

    doi:10.1016/0169-2607(85)90048-3

    authors: Habbema JD,van Oortmarssen GJ,Lubbe JT,van der Maas PJ

    更新日期:1985-05-01 00:00:00

  • Encryption-free data transmission and hand-over in two-tier body area networks.

    abstract:BACKGROUND AND OBJECTIVE:Deployment of Body Area Networks (BAN) in hospitals can enable real time data collection and analysis for patient health. Such networks have a two-tier structure: the primary layer consists of nodes that are installed on hospital facilities, while the second tier contains sensors on patient bod...

    journal_title:Computer methods and programs in biomedicine

    pub_type: 杂志文章

    doi:10.1016/j.cmpb.2020.105411

    authors: Wang W,Qin T,Wang Y

    更新日期:2020-08-01 00:00:00

  • Organisational changes made possible with Viborg PACS.

    abstract::Organisational changes take place at three different levels: at the department, in the hospital and in the county. Important changes locally are the easy and fast access to better images, a rise in production and a possible reduction in patient stay. The radiological services to the community improve, reading can be d...

    journal_title:Computer methods and programs in biomedicine

    pub_type: 杂志文章

    doi:10.1016/s0169-2607(01)00132-8

    authors: Lindhardt F

    更新日期:2001-07-01 00:00:00

  • Assessment of hepatic insulin degradation, in normoglycemic hypertensive patients, by minimal modelling of standard intravenous glucose tolerance test data.

    abstract::Role of hepatic insulin degradation in modulating insulin delivery to peripheral circulation, in insulin-resistant hypertensive patients, is not yet fully understood. This issue was investigated here by a novel application to hypertension of a previously proposed minimal modelling of insulin and C-peptide data, using ...

    journal_title:Computer methods and programs in biomedicine

    pub_type: 杂志文章

    doi:10.1016/j.cmpb.2009.08.007

    authors: Di Nardo F,Boemi M,Burattini R

    更新日期:2010-02-01 00:00:00

  • BASIC computer program to summarize data using nonparametric and parametric statistics including Anderson-Darling test for normality.

    abstract::Tools for calculating Gaussian parametric statistics are widely available in hand-held calculators and program packages for desktop as well as mainframe computers. The standard deviation calculated from non-Gaussian data may, however, be meaningless or even absurd. Furthermore, the standard error of the mean is freque...

    journal_title:Computer methods and programs in biomedicine

    pub_type: 杂志文章

    doi:10.1016/0169-2607(88)90046-6

    authors: Theodorsson E

    更新日期:1988-03-01 00:00:00

  • Improving drug dosing in hospitalized patients: automated modeling of pharmacokinetics for individualization of drug dosage regimens.

    abstract::Many clinical useful drugs have a narrow range of blood concentrations which are both safe and efficacious. Inter-individual and intra-individual variations in drug disposition are important factors causing blood concentrations of drug to fall outside of the therapeutic range. Modeling of the pharmacokinetics of the i...

    journal_title:Computer methods and programs in biomedicine

    pub_type: 杂志文章

    doi:10.1016/0169-2607(89)90069-2

    authors: Lenert L,Sheiner L,Blaschke T

    更新日期:1989-10-01 00:00:00

  • Classification of auditory selective attention using spatial coherence and modular attention index.

    abstract:BACKGROUND AND OBJECTIVE:Brain-Computer Interfaces (BCIs) based on auditory selective attention have been receiving much attention because i) they are useful for completely paralyzed users since they do not require muscular effort or gaze and ii) focusing attention is a natural human ability. Several techniques - such ...

    journal_title:Computer methods and programs in biomedicine

    pub_type: 杂志文章

    doi:10.1016/j.cmpb.2018.10.002

    authors: de Souza AP,Soares QB,Felix LB,Mendes EMAM

    更新日期:2018-11-01 00:00:00

  • Design of a JAIN SLEE/ESB-based platform for routing medical data in the ICU.

    abstract::The importance of computer aided decision making is continuously increasing. In the ICU, medical decision support services gather and process medical data of patients and present results and suggestions to the medical staff. The medical decision support services can monitor for example blood pressure, creatinine level...

    journal_title:Computer methods and programs in biomedicine

    pub_type: 杂志文章

    doi:10.1016/j.cmpb.2008.05.003

    authors: Van Den Bossche B,Van Hoecke S,Danneels C,Decruyenaere J,Dhoedt B,De Turck F

    更新日期:2008-09-01 00:00:00

  • SAS macros for estimation of direct adjusted cumulative incidence curves under proportional subdistribution hazards models.

    abstract::The cumulative incidence function is commonly reported in studies with competing risks. The aim of this paper is to compute the treatment-specific cumulative incidence functions, adjusting for potentially imbalanced prognostic factors among treatment groups. The underlying regression model considered in this study is ...

    journal_title:Computer methods and programs in biomedicine

    pub_type: 杂志文章

    doi:10.1016/j.cmpb.2010.07.005

    authors: Zhang X,Zhang MJ

    更新日期:2011-01-01 00:00:00

  • Standardization of medical imaging in Europe: an integrated initiative.

    abstract::The successful implementation of PACS (or IMACS) depends on the integration of image and image related data handling systems in an overall hospital information system (HIS) and other departmental information systems (DIS), one of which is radiology information system (RIS). With respect to standardization in the medic...

    journal_title:Computer methods and programs in biomedicine

    pub_type: 杂志文章

    doi:10.1016/0169-2607(94)90181-3

    authors: Kiuru A,Mattheus R,Bjerde KW

    更新日期:1994-05-01 00:00:00

  • MSurvPow: a FORTRAN program to calculate the sample size and power for cluster-randomized clinical trials with survival outcomes.

    abstract::Manatunga and Chen [A.K. Manatunga, S. Chen, Sample size estimation for survival outcomes in cluster-randomized studies with small cluster sizes, Biometrics 56 (2000) 616-621] proposed a method to estimate sample size and power for cluster-randomized studies where the primary outcome variable was survival time. The sa...

    journal_title:Computer methods and programs in biomedicine

    pub_type: 杂志文章

    doi:10.1016/j.cmpb.2004.11.004

    authors: Gao F,Manatunga AK,Chen S

    更新日期:2005-04-01 00:00:00

  • A microcomputer program for simulation of linear compartmental physiological models: computation on Apple IIe.

    abstract::The microcomputer program presented here allows the simulation of linear compartmental physiological models whose structure is known. The method used is the 4th order Runge-Kutta method. Implemented on the Apple IIe, this program is fully interactive and presents the possibility of changing model parameters or initial...

    journal_title:Computer methods and programs in biomedicine

    pub_type: 杂志文章

    doi:10.1016/0169-2607(87)90066-6

    authors: Champarnaud G,Magot T,Lutton C

    更新日期:1987-02-01 00:00:00

  • Software for bone histomorphometry by means of a digitizer.

    abstract::A set of programs is described by which a consistent morphometry of bone sections can be performed. The programs are written in FORTRAN IV in a PDP 11/10 minicomputer, under the RT-11 operating system. The bone sections are run through the field of vision of the microscope using a scanning stage in one of several pres...

    journal_title:Computer methods and programs in biomedicine

    pub_type: 杂志文章

    doi:10.1016/0169-2607(85)90003-3

    authors: Clermonts EC,Birkenhäger-Frenkel DH

    更新日期:1985-12-01 00:00:00

  • DiaKin: an integrated program package for hemodialysis kinetics.

    abstract::A flexible program for the IBM PC performing a number of calculations of relevance for the prescription of hemodialysis treatment has been developed. The program has a 'spreadsheet'-like user-friendly interface, and results may be presented graphically. The present implementation covers 89 algorithms/equations, all ba...

    journal_title:Computer methods and programs in biomedicine

    pub_type: 杂志文章

    doi:10.1016/0169-2607(90)90009-x

    authors: Buur T

    更新日期:1990-03-01 00:00:00

  • Seizure onset detection based on detection of changes in brain activity quantified by evolutionary game theory model.

    abstract:BACKGROUND AND OBJECTIVE:Epilepsy is one of the most common diseases of the nervous system, affecting about 1% of the world's population. The unpredictable nature of the epilepsy seizures deprives the patients and those around them of living a normal life. Therefore, the development of new methods that can help these p...

    journal_title:Computer methods and programs in biomedicine

    pub_type: 杂志文章

    doi:10.1016/j.cmpb.2020.105899

    authors: Hamavar R,Asl BM

    更新日期:2020-12-17 00:00:00

  • Intelligent classification of electrocardiogram (ECG) signal using extended Kalman Filter (EKF) based neuro fuzzy system.

    abstract::This study presents the development of a hybrid system consisting of an ensemble of Extended Kalman Filter (EKF) based Multi Layer Perceptron Network (MLPN) and a one-pass learning Fuzzy Inference System using Look-up Table Scheme for the recognition of electrocardiogram (ECG) signals. This system can distinguish vari...

    journal_title:Computer methods and programs in biomedicine

    pub_type: 杂志文章

    doi:10.1016/j.cmpb.2006.03.003

    authors: Meau YP,Ibrahim F,Narainasamy SA,Omar R

    更新日期:2006-05-01 00:00:00

  • An advanced method in fetal phonocardiography.

    abstract::The long-term variability of the fetal heart rate (FHR) provides valuable information on the fetal health status. The routine clinical FHR measurements are usually carried out by the means of ultrasound cardiography. Although the frequent FHR monitoring is recommendable, the high quality ultrasound devices are so expe...

    journal_title:Computer methods and programs in biomedicine

    pub_type: 杂志文章

    doi:10.1016/s0169-2607(02)00111-6

    authors: Várady P,Wildt L,Benyó Z,Hein A

    更新日期:2003-07-01 00:00:00