Wall shear stress distribution at the carotid bifurcation: influence of eversion carotid endarterectomy.

Abstract:

OBJECTIVES:To test the feasibility of four-dimensional (4D) flow MRI to quantify the systolic wall shear stress (WSSsystole) and oscillatory shear index (OSI) in high-grade internal carotid artery (ICA) stenosis before and after endarterectomy (CEA). METHODS:Twenty patients with ≥60 % ICA stenosis were prospectively and consequently included. Four-dimensional flow MRI was used to measure individual time-resolved 3D blood flow velocities. Segmental WSSsystole and OSI were derived at eight wall segments in analysis planes positioned along the ICA, common (CCA) and external carotid artery (ECA). RESULTS:Regional WSSsystole of all patients decreased after CEA (P < 0.05). Changes were most prominent at the ICA bulb but remained unchanged in the CCA and ECA. OSI was significantly lower after CEA in the lateral vessel walls (P < 0.05). For analysis planes at the stenosis in- and outlet, a reduction of mean WSSsystole by 32 % and 52 % (P < 0.001) and OSI distal to the stenosis (40 %, P = 0.01) was found after CEA. CONCLUSIONS:Our findings show the potential of in vivo 4D flow MRI to quantify haemodynamic changes in wall shear stress even in patients with complex flow conditions.

journal_name

Eur Radiol

journal_title

European radiology

authors

Harloff A,Berg S,Barker AJ,Schöllhorn J,Schumacher M,Weiller C,Markl M

doi

10.1007/s00330-013-2953-4

subject

Has Abstract

pub_date

2013-12-01 00:00:00

pages

3361-9

issue

12

eissn

0938-7994

issn

1432-1084

journal_volume

23

pub_type

杂志文章
  • A retrospectively ECG-gated multislice spiral CT scan and reconstruction technique with suppression of heart pulsation artifacts for cardio-thoracic imaging with extended volume coverage.

    abstract::A method for cardio-thoracic multislice spiral CT imaging with ECG gating for suppression of heart pulsation artifacts is introduced. The proposed technique offers extended volume coverage compared with standard ECG-gated spiral scan and reconstruction approaches for cardiac applications: Thin-slice data of the entire...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1388-0

    authors: Flohr T,Prokop M,Becker C,Schoepf UJ,Kopp AF,White RD,Schaller S,Ohnesorge B

    更新日期:2002-06-01 00:00:00

  • An eight-year prospective controlled study about the safety and diagnostic value of cardiac and non-cardiac 1.5-T MRI in patients with a conventional pacemaker or a conventional implantable cardioverter defibrillator.

    abstract:OBJECTIVES:To investigate safety and diagnostic value of 1.5-T MRI in carriers of conventional pacemaker (cPM) or conventional implantable defibrillator (cICD). METHODS:We prospectively compared cPM/cICD-carriers undergoing MRI (study group, SG), excluding those device-dependent or implanted <6 weeks before enrolment ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-5098-z

    authors: Lupo P,Cappato R,Di Leo G,Secchi F,Papini GDE,Foresti S,Ali H,De Ambroggi GMG,Sorgente A,Epicoco G,Cannaò PM,Sardanelli F

    更新日期:2018-06-01 00:00:00

  • CT-guided intervention using a patient laser marker system.

    abstract::To prove the usefulness of a simple laser marker system (LMS) in target definition as well as examination procedure for CT-guided interventions, 130 cases of diagnostic biopsies and lumbal sympathectomies were compared. In 75 cases LMS and in 55 cases a simple crossgrid was used. Taking advantage of the LMS, the param...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300051054

    authors: Kloeppel R,Weisse T,Deckert F,Wilke W,Pecher S

    更新日期:2000-01-01 00:00:00

  • Radiolucencies and cavitation in bronchioloalveolar carcinoma: CT-pathologic correlation.

    abstract::Bronchioloalveolar carcinoma (BAC) is a polymorphic lung cancer the incidence of which is rising. The presence of intratumoral radiolucencies is an important feature of bronchioloalveolar carcinoma. The aim of this study was to present pictorially the spectrum of intratumoral radiolucencies visible in BAC. In 57 BACs ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050627

    authors: Gaeta M,Caruso R,Blandino A,Bartiromo G,Scribano E,Pandolfo I

    更新日期:1999-01-01 00:00:00

  • Estimation of tissue perfusion by dynamic contrast-enhanced imaging: simulation-based evaluation of the steepest slope method.

    abstract:OBJECTIVE:Tissue perfusion is frequently determined from dynamic contrast-enhanced CT or MRI image series by means of the steepest slope method. It was thus the aim of this study to systematically evaluate the reliability of this analysis method on the basis of simulated tissue curves. METHODS:9600 tissue curves were ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-010-1787-6

    authors: Brix G,Zwick S,Griebel J,Fink C,Kiessling F

    更新日期:2010-09-01 00:00:00

  • Angiomyolipoma (AML) without visible fat: Ultrasound, CT and MR imaging features with pathological correlation.

    abstract:OBJECTIVE:To compare imaging findings with histopathology in AML without visible fat (AMLwvf). MATERIAL AND METHODS:With IRB approval, we identified 18 AMLwvf that underwent CT between 2002-2014. A radiologist measured NECT-attenuation, corticomedullary (CM) and nephrographic (NG) enhancement, echogenicity relative to...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-3851-8

    authors: Hakim SW,Schieda N,Hodgdon T,McInnes MD,Dilauro M,Flood TA

    更新日期:2016-02-01 00:00:00

  • Do CEC guidelines under-utilise the full potential of increasing kVp as a dose-reducing tool?

    abstract::Increasing beam energies are well established as a radiation dose-reducing tool in diagnostic radiology. This has led to useful recommendations by the Commission of European Communities (CEC) for appropriate kVp values to be employed for a variety of examinations. The current work tests the hypothesis that kVp levels ...

    journal_title:European radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1007/s00330-002-1810-7

    authors: Doherty P,O'Leary D,Brennan PC

    更新日期:2003-08-01 00:00:00

  • Bilateral renal cell carcinoma in a horseshoe kidney: preoperative assessment with MRI and digital subtraction angiography.

    abstract::Renal cell carcinoma in a horseshoe kidney is an unusual entity. To our knowledge, only 123 cases have been published to date. We report the first bilateral case of two clear-cell carcinomas in an asymmetrically fused kidney. Optimum preservation of renal function after radical tumor removal requires accurate preopera...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050615

    authors: Schubert RA,Söldner J,Steiner T,Schubert J,Kaiser WA

    更新日期:1998-01-01 00:00:00

  • Correction to: Cone-beam breast CT features associated with HER2/neu overexpression in patients with primary breast cancer.

    abstract::The original version of this article, published on 03 January 2020, unfortunately contained two mistakes. ...

    journal_title:European radiology

    pub_type: 杂志文章,已发布勘误

    doi:10.1007/s00330-020-06673-4

    authors: Zhu Y,Zhang Y,Ma Y,Li H,Liu A,Han P,Yin L,Lv N,Li Z,Lu H,Liu P,Ye Z

    更新日期:2020-06-01 00:00:00

  • A novel removable shield attached to C-arm units against scattered X-rays from a patient's side.

    abstract:OBJECTIVES:We invented a drape-like shield against scattered X-rays that can safely come into contact with medical equipment or people during fluoroscopically guided procedures. The shield can be easily removed from a C-arm unit using one hand. We evaluated the use of the novel removable shield during the endoscopic re...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-014-3186-x

    authors: Mori H,Koshida K,Ishigamori O,Matsubara K

    更新日期:2014-08-01 00:00:00

  • Value of bone suppression software in chest radiographs for improving image quality and reducing radiation dose.

    abstract:OBJECTIVES:To compare image quality and radiation dose between dual-energy subtraction (DES)-based bone suppression images (D-BSIs) and software-based bone suppression images (S-BSIs). METHODS:Chest radiographs (CXRs) of forty adult patients were obtained with the two X-ray devices, one with DES and one with bone supp...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-07596-w

    authors: Hong GS,Do KH,Son AY,Jo KW,Kim KP,Yun J,Lee CW

    更新日期:2021-01-13 00:00:00

  • Presinusoidal portal hypertension does not affect hepatic artery resistance index.

    abstract::We aimed to determine the mean hepatic artery resistance index (RI) in presinusoidal portal hypertension and to compare the values with those in sinusoidal portal hypertension. The hepatic artery RIs of 11 patients with presinusoidal portal hypertension, 12 patients with sinusoidal portal hypertension and 16 healthy s...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050806

    authors: Erden A,Altuntaş B,Olçer T,Cumhur T

    更新日期:1999-01-01 00:00:00

  • Practical applications of deep learning: classifying the most common categories of plain radiographs in a PACS using a neural network.

    abstract:OBJECTIVES:The goal of the present study was to classify the most common types of plain radiographs using a neural network and to validate the network's performance on internal and external data. Such a network could help improve various radiological workflows. METHODS:All radiographs from the year 2017 (n = 71,274) a...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-07241-6

    authors: Dratsch T,Korenkov M,Zopfs D,Brodehl S,Baessler B,Giese D,Brinkmann S,Maintz D,Pinto Dos Santos D

    更新日期:2020-09-28 00:00:00

  • Abnormalities of the airways and lung parenchyma in asthmatics: CT observations in 50 patients and inter- and intraobserver variability.

    abstract::The purpose of the study was to evaluate the CT abnormalities of airways and lung parenchyma in asthmatic patients and to assess inter- and intraobserver variability for these abnormalities. The CT scans of 50 asthmatic patients and 10 healthy volunteers were assessed independently by four independent chest radiologis...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/BF00181147

    authors: Grenier P,Mourey-Gerosa I,Benali K,Brauner MW,Leung AN,Lenoir S,Cordeau MP,Mazoyer B

    更新日期:1996-01-01 00:00:00

  • US and CT findings of multicentric leiomyosarcomatosis.

    abstract::This article presents a case of leiomyosarcomatosis with widespread lesions involving the soft tissues and the most unlikely organs such as thyroid and salivary glands, pancreas, ligamentum teres, bladder wall, and bones without lymph node or distant metastasis. The CT and US findings of this rare phenomenon are discu...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050738

    authors: Akata D,Aralasmak A,Ozmen MN,Akhan O,Altundağ K,Güllü I

    更新日期:1999-01-01 00:00:00

  • Management of intussusception.

    abstract::Intussusception represents the most common abdominal emergency in infancy. The classical clinical triad, consisting of abdominal colics, red jelly stools and a palpable mass, is only present in approximately 50% of cases, 20% of patients are symptom free at clinical presentation. Primary imaging modality of choice is ...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-003-2033-2

    authors: Sorantin E,Lindbichler F

    更新日期:2004-03-01 00:00:00

  • The Left Atrio-Vertebral Ratio: a new simple means for assessing left atrial enlargement on Computed Tomography.

    abstract:OBJECTIVE:The purpose of this study is to describe a new method to quickly estimate left atrial enlargement (LAE) on Computed Tomography. METHODS:Left atrial (LA) volume was assessed with a 3D-threshold Hounsfield unit detection technique, including left atrial appendage and excluding pulmonary venous confluence, in 2...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-5041-3

    authors: Montillet M,Baqué-Juston M,Tasu JP,Bertrand S,Berthier F,Zarqane N,Brunner P

    更新日期:2018-03-01 00:00:00

  • Visualising liver fibrosis by phase-contrast X-ray imaging in common bile duct ligated mice.

    abstract:OBJECTIVES:To determine whether phase-contrast X-ray imaging can be used to visualise directly the accumulated extracellular matrix proteins associated with liver fibrosis in common bile duct ligated mice. METHODS:Twenty-six-week-old C57BL female mice were randomised into three groups. In groups 1 (n = 5) and 2 (n = 1...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-012-2630-z

    authors: Zhang X,Yang XR,Chen Y,Li HQ,Li RM,Yuan QX,Zhu PP,Huang WX,Peng WJ

    更新日期:2013-02-01 00:00:00

  • Assessing response in bone metastases in prostate cancer with diffusion weighted MRI.

    abstract:OBJECTIVES:To determine whether changes in ADC of bone metastases secondary to prostate carcinoma are significantly different in responders compared with progressors on chemotherapy. METHODS:Twenty-six patients with known bone metastases secondary to prostate carcinoma underwent diffusion-weighted MRI of the lumbar sp...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-011-2173-8

    authors: Messiou C,Collins DJ,Giles S,de Bono JS,Bianchini D,de Souza NM

    更新日期:2011-10-01 00:00:00

  • Head-to-head comparison of multiple cardiovascular magnetic resonance techniques for the detection and quantification of intramyocardial haemorrhage in patients with ST-elevation myocardial infarction.

    abstract:OBJECTIVES:T2*-weighted (T2*w) is deemed as a reference standard for post-infarction intramyocardial haemorrhage (IMH). However, high proportion of T2* images is affected by off-resonance artefacts hampering image interpretation. Diagnostic accuracy and precision of alternative techniques for IMH diagnosis and quantifi...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-07254-1

    authors: Pavon AG,Georgiopoulos G,Vincenti G,Muller O,Monney P,Berchier G,Cirillo C,Eeckhout E,Schwitter J,Masci PG

    更新日期:2020-09-14 00:00:00

  • Assessment and treatment planning of lateral intracranial dural arteriovenous fistulas in 3 T MRI and DSA: A detailed analysis under consideration of time-resolved imaging of contrast kinetics (TRICKS) and ce-MRA sequences.

    abstract:OBJECTIVES:The current gold standard in the assessment of lateral intracranial dural arteriovenous fistulas (LDAVF) is digital subtraction angiography (DSA). However, magnetic resonance imaging (MRI) is a non-invasive emerging tool for the evaluation of such lesions. The aim of our study was to compare the DSA to our 3...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4335-1

    authors: Ertl L,Brückmann H,Kunz M,Patzig M,Brem C,Forbrig R,Fesl G

    更新日期:2016-12-01 00:00:00

  • A New Model for MR Evaluation of Liver Function with Gadoxetic Acid, Including Both Uptake and Excretion.

    abstract:OBJECTIVES:Most existing models that are in use to model hepatic function through assessment of hepatic gadoxetic acid enhancement kinetics do not consider quantitative measures of gadoxetic excretion. We developed a model that allows a simultaneous quantitation of uptake and excretion of liver specific contrast agents...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5500-5

    authors: Truhn D,Kuhl CK,Ciritsis A,Barabasch A,Kraemer NA

    更新日期:2019-01-01 00:00:00

  • Topogram-based automated selection of the tube potential and current in thoraco-abdominal trauma CT - a comparison to fixed kV with mAs modulation alone.

    abstract:OBJECTIVE:To investigate the impact of automated attenuation-based tube potential selection on image quality and exposure parameters in polytrauma patients undergoing contrast-enhanced thoraco-abdominal CT. METHODS:One hundred patients were examined on a 16-slice device at 120 kV with 190 ref.mAs and automated mA modu...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-014-3197-7

    authors: Frellesen C,Stock W,Kerl JM,Lehnert T,Wichmann JL,Nau C,Geiger E,Wutzler S,Beeres M,Schulz B,Bodelle B,Ackermann H,Vogl TJ,Bauer RW

    更新日期:2014-07-01 00:00:00

  • Value of ADC measurements for nodal staging after chemoradiation in locally advanced rectal cancer-a per lesion validation study.

    abstract:OBJECTIVES:To evaluate the performance of diffusion-weighted MRI (DWI) in addition to T2-weighted (T2W) MRI for nodal restaging after chemoradiation in rectal cancer. METHODS:Thirty patients underwent chemoradiation followed by MRI (1.5 T) and surgery. Imaging consisted of T2W-MRI and DWI (b0, 500, 1000). On T2W-MRI, ...

    journal_title:European radiology

    pub_type: 临床试验,杂志文章

    doi:10.1007/s00330-010-1937-x

    authors: Lambregts DM,Maas M,Riedl RG,Bakers FC,Verwoerd JL,Kessels AG,Lammering G,Boetes C,Beets GL,Beets-Tan RG

    更新日期:2011-02-01 00:00:00

  • Assessment of myocardial viability by MR imaging.

    abstract::Diagnosis of myocardial viability after infarction focuses on the prediction of functional improvement of dysfunctional myocardium after revascularization therapy. Magnetic resonance imaging provides different approaches for the detection of myocardial viability. Measurement of end-diastolic wall thickness is easy to ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1701-y

    authors: Sandstede JJ

    更新日期:2003-01-01 00:00:00

  • Pitfalls in sonography of the Gamekeeper's thumb.

    abstract::The gamekeeper's or skier's thumb is a very common injury. Nondisplaced tears of the ulnar collateral ligament of the thumb (UCL) may be treated conservatively. For that reason an accurate diagnosis is mandatory for choosing the correct therapy. Ultrasound is able to depict the position of the torn UCL correctly in ap...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050111

    authors: Hergan K,Mittler C,Oser W

    更新日期:1997-01-01 00:00:00

  • Abdominal spiral CT in children: which radiation exposure is required?

    abstract::We decided to test to what extent dose reduction is possible in abdominal spiral computed tomography (CT) in young children without loss of anatomic diagnostic information. A retrospective study was performed of 30 abdominal CT examinations of children aged 3 months to 7 years. These were divided into two groups: grou...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300100989

    authors: Wormanns D,Diederich S,Lenzen H,Lange P,Link TM,Ludwig K,Papke K,Hagedorn C,Heindel W

    更新日期:2001-01-01 00:00:00

  • Hypoxia and perfusion in breast cancer: simultaneous assessment using PET/MR imaging.

    abstract:OBJECTIVES:Hypoxia is associated with poor prognosis and treatment resistance in breast cancer. However, the temporally variant nature of hypoxia can complicate interpretation of imaging findings. We explored the relationship between hypoxia and vascular function in breast tumours through combined 18F-fluoromisonidazol...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-07067-2

    authors: Carmona-Bozo JC,Manavaki R,Woitek R,Torheim T,Baxter GC,Caracò C,Provenzano E,Graves MJ,Fryer TD,Patterson AJ,Gilbert FJ

    更新日期:2021-01-01 00:00:00

  • Conventional radiography in juvenile idiopathic arthritis: Joint recommendations from the French societies for rheumatology, radiology and paediatric rheumatology.

    abstract:BACKGROUND:Juvenile idiopathic arthritis (JIA) can cause structural damage. However, data on conventional radiography (CR) in JIA are scant. OBJECTIVE:To provide pragmatic guidelines on CR in each non-systemic JIA subtype. METHODS:A multidisciplinary task force of 16 French experts (rheumatologists, paediatricians, r...

    journal_title:European radiology

    pub_type: 杂志文章,实务指引,评审

    doi:10.1007/s00330-018-5304-7

    authors: Marteau P,Adamsbaum C,Rossi-Semerano L,De Bandt M,Lemelle I,Deslandre C,Tran TA,Lohse A,Solau-Gervais E,Sordet C,Pillet P,Bader-Meunier B,Wipff J,Gaujoux-Viala C,Breton S,Devauchelle-Pensec V

    更新日期:2018-09-01 00:00:00

  • Increased epicardial fat is independently associated with the presence and chronicity of atrial fibrillation and radiofrequency ablation outcome.

    abstract:OBJECTIVE:To determine whether intrathoracic fat volumes are associated with presence and chronicity of atrial fibrillation (AF) and radiofrequency ablation (RFA) treatment outcome. METHODS:IRB approval was obtained and patient consent was waived for this HIPAA-compliant retrospective study. 169 patients with AF (75 n...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-3643-1

    authors: Stojanovska J,Kazerooni EA,Sinno M,Gross BH,Watcharotone K,Patel S,Jacobson JA,Oral H

    更新日期:2015-08-01 00:00:00