Unilateral iliac horn (central Posterior iliac process). Case report.

Abstract:

:An anomaly of the pelvis consisting of a unilateral iliac horn is presented. It appeared as an isolated bony malformation which was not associated with signs, symptoms, or stigmata of hereditary onycho-osteodysplasia.

journal_name

Radiology

journal_title

Radiology

authors

Wasserman D

doi

10.1148/120.3.562

subject

Has Abstract

pub_date

1976-09-01 00:00:00

pages

562

issue

3

eissn

0033-8419

issn

1527-1315

journal_volume

120

pub_type

杂志文章
  • In vivo high-resolution MR imaging of the skin in a whole-body system at 1.5 T.

    abstract::High-resolution magnetic resonance (MR) images of the skin were acquired with a whole-body MR system at 1.5 T by adding a specific imaging module: A saddle-shaped surface gradient coil was connected in place of one of the gradient coils of the system, and a surface radio-frequency coil with a 1.5-cm radius was placed ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.176.2.2367660

    authors: Bittoun J,Saint-Jalmes H,Querleux BG,Darrasse L,Jolivet O,Idy-Peretti I,Wartski M,Richard SB,Leveque JL

    更新日期:1990-08-01 00:00:00

  • The equivalent tissue-air ratio method for making absorbed dose calculations in a heterogeneous medium.

    abstract::The CT scanner makes three-dimensional anatomical information available for treatment planning, the calculational algorithm being the limiting factor in dose calculations. A method has been developed, called the "effective tissue-air ratio method," that uses all the information but reduces it to manageable proportions...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/129.3.787

    authors: Sontag MR,Cunningham JR

    更新日期:1978-12-01 00:00:00

  • Meniscal tears: MR demonstration of experimentally produced injuries.

    abstract::Magnetic resonance (MR) imaging was performed using a 1.5-T magnet on eight immature swine knees with surgically produced vertical and horizontal meniscal tears. Three radiologists, interpreting the images independently, detected all tears. Tears in the middle portion of the meniscus were best seen on sagittal views, ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.158.3.3945740

    authors: Beltran J,Noto AM,Mosure JC,Bools JC,Zuelzer W,Christoforidis AJ

    更新日期:1986-03-01 00:00:00

  • Cartilage quality assessment by using glycosaminoglycan chemical exchange saturation transfer and (23)Na MR imaging at 7 T.

    abstract:PURPOSE:To compare a glycosaminoglycan chemical exchange saturation transfer (gagCEST) imaging method, which enables sampling of the water signal as a function of the presaturation offset (z-spectrum) at 13 points in clinically feasible imaging times, with sodium 23 ((23)Na) magnetic resonance (MR) imaging in patients ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.11101841

    authors: Schmitt B,Zbýn S,Stelzeneder D,Jellus V,Paul D,Lauer L,Bachert P,Trattnig S

    更新日期:2011-07-01 00:00:00

  • Use of low-osmolar agents and premedication to reduce the frequency of adverse reactions to radiographic contrast media: a survey of the Society of Uroradiology.

    abstract:PURPOSE:To assess the decisions made by uroradiologists regarding choice of type of intravenous contrast material (low-osmolar contrast media [LOCM] vs conventional ionic agents) and frequency of use of corticosteroid prophylaxis. MATERIALS AND METHODS:A questionnaire was mailed to 158 members of the Society of Urorad...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.194.2.7824710

    authors: Cohan RH,Ellis JH,Dunnick NR

    更新日期:1995-02-01 00:00:00

  • Coronary CT Angiography-derived Fractional Flow Reserve.

    abstract::Invasive coronary angiography (ICA) with measurement of fractional flow reserve (FFR) by means of a pressure wire technique is the established reference standard for the functional assessment of coronary artery disease (CAD) ( 1 , 2 ). Coronary computed tomographic (CT) angiography has emerged as a noninvasive method ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2017162641

    authors: Tesche C,De Cecco CN,Albrecht MH,Duguay TM,Bayer RR 2nd,Litwin SE,Steinberg DH,Schoepf UJ

    更新日期:2017-10-01 00:00:00

  • Bilateral venography of the lower extremities.

    abstract::The authors describe a simplified method of venography of the lower extremity which gives improved visualization of the proximal deep venous system. The technique involves high volumes of contrast material, no tourniquets, a relatively vertical, non-weight-bearing position, and passive elevation of the legs. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/123.3.802

    authors: Rampton JB,Armstrong JD Jr

    更新日期:1977-06-01 00:00:00

  • Periventricular leukomalacia: correlation between MR imaging and autopsy findings during the first 2 months of life.

    abstract:PURPOSE:To correlate magnetic resonance (MR) imaging and pathologic findings in premature infants with periventricular leukomalacia (PVL). MATERIALS AND METHODS:Eight premature infants with PVL who died after 3-7 weeks of life were studied with in vivo T1-weighted MR imaging, and imaging patterns were compared with hy...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.189.1.8372220

    authors: Schouman-Claeys E,Henry-Feugeas MC,Roset F,Larroche JC,Hassine D,Sadik JC,Frija G,Gabilan JC

    更新日期:1993-10-01 00:00:00

  • A new approach to ultrasound image recording using a video disc recorder.

    abstract::A system utilizing a multi-image capacity video disc recorder rather than a photographic camera for the initial recording of ultrasound images id described, as well as the resulting benefits. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/133.2.530

    authors: Skolnick ML

    更新日期:1979-11-01 00:00:00

  • Breast cancer imaging with In-111 human IgM monoclonal antibodies: preliminary studies.

    abstract::Detection of specific tumor sites was studied with scintigraphy and radiolabeled human IgM monoclonal antibodies (MoAbs). Ten patients with metastatic breast cancer received an infusion of one of three indium-111-labeled anti-breast carcinoma MoAbs. The time of infusion ranged from 30 minutes to 2 hours. Three patient...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.167.1.3347750

    authors: Ryan KP,Dillman RO,DeNardo SJ,DeNardo GL,Beauregard J,Hagan PL,Amox DG,Clutter ML,Burnett KG,Rulot CM

    更新日期:1988-04-01 00:00:00

  • Retrosomatic clefts: computed tomographic appearance.

    abstract::A case of bilateral clefts in the pedicles of the L1 vertebra, diagnosed by computed tomography, is presented. The differentiation from other clefts located laterally in the neural arch is briefly summarized, and the possible origin of this entity is discussed. It is improbable that the clefts represent persistent neu...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.148.2.6867340

    authors: Johansen JG,McCarty DJ,Haughton VM

    更新日期:1983-08-01 00:00:00

  • Small-vessel radiography in situ with monochromatic synchrotron radiation.

    abstract:PURPOSE:To evaluate the usefulness of a radiographic system with monochromatic synchrotron radiation to depict small vessels and peripheral secretory ducts. MATERIALS AND METHODS:Radiography of various organs was tested in 14 anesthetized dogs and pancreatography was performed in an excised human pancreas by using the...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.201.1.8816540

    authors: Mori H,Hyodo K,Tanaka E,Uddin-Mohammed M,Yamakawa A,Shinozaki Y,Nakazawa H,Tanaka Y,Sekka T,Iwata Y,Handa S,Umetani K,Ueki H,Yokoyama T,Tanioka K,Kubota M,Hosaka H,Ishikawa N,Ando M

    更新日期:1996-10-01 00:00:00

  • Percutaneous transperitoneal lymph-node biopsy as a means of improving lymphographic diagnosis.

    abstract::Percutaneous transperitoneal fine-needle lymph-node biopsy was performed in 52 patients to establish a diagnosis of metastatic disease in nodal defects detected during lymphography. The procedure was found to be highly accurate, with few false-negatives and no false-positives. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/131.3.647

    authors: Macintosh PK,Thomson KR,Barbaric ZL

    更新日期:1979-06-01 00:00:00

  • Are two-dimensional CT measurements of small noncalcified pulmonary nodules reliable?

    abstract:PURPOSE:To evaluate the intra- and interreader agreement of two-dimensional computed tomographic (CT) measurements of pulmonary nodules less than 2 cm in diameter. MATERIALS AND METHODS:Three readers independently made three serial measurements of each of 54 pulmonary nodules measuring 3-18 mm that had been observed o...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2312030167

    authors: Revel MP,Bissery A,Bienvenu M,Aycard L,Lefort C,Frija G

    更新日期:2004-05-01 00:00:00

  • Coronary artery disease: assessment with a comprehensive MR imaging protocol--initial results.

    abstract::A comprehensive magnetic resonance (MR) imaging protocol for assessment of coronary artery disease (CAD) is presented. The protocol includes multiphase gradient-echo cine MR imaging for assessment of cardiac function, first-pass myocardial perfusion imaging at rest and during adenosine stress, MR imaging with delayed ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2243011436

    authors: Plein S,Ridgway JP,Jones TR,Bloomer TN,Sivananthan MU

    更新日期:2002-10-01 00:00:00

  • Atypical distribution of Pneumocystis carinii infiltrates during radiation therapy.

    abstract::Bilateral peripheral pulmonary infiltrates caused by Pneumocystis carinii developed in a patient undergoing mediastinal irradiation after chemotherapy for Hodgkin disease. The paramediastinal part of the lung included within the treatment port remained clear during the 2 1/2 weeks of radiation therapy. The distributio...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.163.3.3495020

    authors: Panicek DM,Groskin SA,Chung CT,Heitzman ER,Sagerman RH

    更新日期:1987-06-01 00:00:00

  • Distribution of various labeled thioglucoses in rodents.

    abstract::Gold, silver and lead thioglucose were evaluated in rodents to determine the value of organo-metallic compounds in the study of metabolic abnormalities. Increased radioactivity concentration was noted in the hypothalamus with all compounds. Gold thioglucose concentrated in the kidneys and thymus, and 203Pb-thioglucose...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/15.3.723

    authors: Atkins HL,Lambrecht RM,Wolf AP,Ansari AN,Guillaume M

    更新日期:1975-06-01 00:00:00

  • Proton imaging for medical applications.

    abstract::In order to demonstrate the potential advantages of proton imaging for medical use, a 205-MeV proton beam was developed using the Argonne National Laboratory Booster I synchrotron. Data were taken using a narrow scanning beam and an electronic detector system. The dose reduction and an improved mass resulution over th...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.135.2.6245430

    authors: Kramer SL,Moffett DR,Martin RL,Colton EP,Steward VW

    更新日期:1980-05-01 00:00:00

  • Robotically Assisted Sonic Therapy as a Noninvasive Nonthermal Ablation Modality: Proof of Concept in a Porcine Liver Model.

    abstract::Purpose To determine the feasibility of creating a clinically relevant hepatic ablation (ie, an ablation zone capable of treating a 2-cm liver tumor) by using robotically assisted sonic therapy (RAST), a noninvasive and nonthermal focused ultrasound therapy based on histotripsy. Materials and Methods This study was ap...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2018171544

    authors: Smolock AR,Cristescu MM,Vlaisavljevich E,Gendron-Fitzpatrick A,Green C,Cannata J,Ziemlewicz TJ,Lee FT Jr

    更新日期:2018-05-01 00:00:00

  • Percutaneous transluminal renal angioplasty: initial and long-term results.

    abstract::Renal artery stenosis in 201 patients with hypertension was treated with percutaneous transluminal renal angioplasty (PTRA). A total of 213 procedures were performed as treatment of 262 separate stenosis. The stenosis was caused by atherosclerosis in 134 cases and by fibromuscular dysplasia (FMD) in 52 cases; the caus...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.171.2.2523080

    authors: Klinge J,Mali WP,Puijlaert CB,Geyskes GG,Becking WB,Feldberg MA

    更新日期:1989-05-01 00:00:00

  • Spondylodiskitic abscesses: CT-guided percutaneous catheter drainage.

    abstract:PURPOSE:To determine whether computed tomographically (CT) guided percutaneous catheter drainage of spondylodiskitic abscesses is an appropriate and effective alternative to surgery. MATERIALS AND METHODS:CT-guided percutaneous catheter drainage was performed in 21 patients (16 men, five women; age range, 24-81 years)...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.208.2.9680560

    authors: Staatz G,Adam GB,Keulers P,Vorwerk D,Günther RW

    更新日期:1998-08-01 00:00:00

  • Collaborative radiologic and histopathologic assessment of fibrotic lung disease.

    abstract::The idiopathic interstitial pneumonias (IIPs) are a seemingly disconnected collection of diseases usually associated with the presence of pulmonary fibrosis. Categorization of the IIPs continues to be problematic despite recent attempts to refine the diagnostic criteria and suggests that rather than separate diseases,...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.10090717

    authors: Galvin JR,Frazier AA,Franks TJ

    更新日期:2010-06-01 00:00:00

  • Detection of unsuspected central pulmonary embolism with conventional contrast-enhanced CT.

    abstract::When fast, nondynamic scanning techniques are used in combination with adequate intravenous injection of contrast material, good-quality images of the pulmonary artery (PA) can be obtained with routine computed tomography (CT). The purpose of this study was to evaluate PA filling defects detected on these CT scans. Tw...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.188.3.8351360

    authors: Verschakelen JA,Vanwijck E,Bogaert J,Baert AL

    更新日期:1993-09-01 00:00:00

  • Hyperacute thermal lesions: MR imaging evaluation of development in the brain.

    abstract:PURPOSE:To determine the natural time course of development of hyperacute thermal lesions in the brain. MATERIALS AND METHODS:Ten interstitial lesions were created in five rabbit brains with a radio-frequency probe; an electrode-tip temperature of 80 degrees C was maintained for 60 seconds. Continuous fast spin-echo m...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.196.2.7617870

    authors: Farahani K,Mischel PS,Black KL,De Salles AA,Anzai Y,Lufkin RB

    更新日期:1995-08-01 00:00:00

  • Resonance by rod-shaped reflectors in ultrasound test objects.

    abstract::Rod-shaped reflectors such as those used in the AIUM test object resonate at medical ultrasound frequencies, producing artifacts posterior to the reflector. Rods of various diameters and materials were examined to determine their resonant properties, and the effect of the Plexiglas scanning surface of the enclosure on...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.139.1.7208920

    authors: Hefner LV,Goldstein A

    更新日期:1981-04-01 00:00:00

  • Mediastinal lymphadenopathy and pulmonary arterial hypertension in mixed connective tissue disease.

    abstract::A case of mixed connective tissue disease (MCTD) is presented in which mediastinal lymphadenopathy was the most prominent radiological finding detected by plain chest radiographs and computed tomography. Pulmonary arterial hypertension, which is a rare and often fatal complication of MCTD, also developed in this patie...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.154.2.3155570

    authors: Guit GL,Shaw PC,Ehrlich J,Kroon HM,Oudkerk M

    更新日期:1985-02-01 00:00:00

  • Barium studies in small-bowel infarction. Radiological-pathological correlation.

    abstract::Seven patients with proved small-bowel infarction were studied to determine whether the radiographic appearance of an ischemic segment is helpful in predicting the severity of the process, in particular the potential viability or nonviability of the affected bowel. It was found that the barium examination is useful in...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/123.2.303

    authors: Joffe N,Goldman H,Antonioli DA

    更新日期:1977-05-01 00:00:00

  • Acute nontraumatic abdominal pain in adult patients: abdominal radiography compared with CT evaluation.

    abstract:PURPOSE:To compare the diagnostic yield of abdominal radiography with that of computed tomography (CT) in adult patients presenting to the emergency department with nontraumatic abdominal pain. MATERIALS AND METHODS:Records of 1,000 consecutive patients presenting to the emergency department with acute abdominal pain ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2251011282

    authors: Ahn SH,Mayo-Smith WW,Murphy BL,Reinert SE,Cronan JJ

    更新日期:2002-10-01 00:00:00

  • Choledocholithiasis: evaluation of MR cholangiography for diagnosis.

    abstract:PURPOSE:To evaluate the test performance of magnetic resonance (MR) cholangiography for help in diagnosing choledocholithiasis. MATERIALS AND METHODS:Fast spin-echo MR cholangiography was performed by using a torso multicoil array in 110 patients suspected of having bile duct obstruction. Axial and coronal images were...

    journal_title:Radiology

    pub_type: 临床试验,杂志文章

    doi:10.1148/radiology.209.2.9807570

    authors: Reinhold C,Taourel P,Bret PM,Cortas GA,Mehta SN,Barkun AN,Wang L,Tafazoli F

    更新日期:1998-11-01 00:00:00

  • Thyroid gland tumor diagnosis at US elastography.

    abstract:PURPOSE:To prospectively evaluate the elastographic appearance of thyroid gland tumors and explore the potential sensitivity and specificity of ultrasonographic (US) elastography for differentiating benign and malignant tumors, with histopathologic analysis as the reference standard. MATERIALS AND METHODS:The study wa...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2363041248

    authors: Lyshchik A,Higashi T,Asato R,Tanaka S,Ito J,Mai JJ,Pellot-Barakat C,Insana MF,Brill AB,Saga T,Hiraoka M,Togashi K

    更新日期:2005-10-01 00:00:00