Abstract:
OBJECTIVES:To compare Magnetic Resonance (MR) and Computed Tomography (CT) for the assessment of left (LV) and right (RV) ventricular functional parameters. METHODS:Seventy nine patients underwent both Cardiac CT and Cardiac MR. Images were acquired using short axis (SAX) reconstructions for CT and 2D cine b-SSFP (balanced-steady state free precession) SAX sequence for MR, and evaluated using dedicated software. RESULTS:CT and MR images showed good agreement: LV EF (Ejection Fraction) (52 ± 14% for CT vs. 52 ± 14% for MR; r = 0.73; p > 0.05); RV EF (47 ± 12% for CT vs. 47 ± 12% for MR; r = 0.74; p > 0.05); LV EDV (End Diastolic Volume) (74 ± 21 ml/m² for CT vs. 76 ± 25 ml/m² for MR; r = 0.59; p > 0.05); RV EDV (84 ± 25 ml/m² for CT vs. 80 ± 23 ml/m² for MR; r = 0.58; p > 0.05); LV ESV (End Systolic Volume)(37 ± 19 ml/m² for CT vs. 38 ± 23 ml/m² for MR; r = 0.76; p > 0.05); RV ESV (46 ± 21 ml/m² for CT vs. 43 ± 18 ml/m² for MR; r = 0.70; p > 0.05). Intra- and inter-observer variability were good, and the performance of CT was maintained for different EF subgroups. CONCLUSIONS:Cardiac CT provides accurate and reproducible LV and RV volume parameters compared with MR, and can be considered as a reliable alternative for patients who are not suitable to undergo MR. KEY POINTS:• Cardiac-CT is able to provide Left and Right Ventricular function. • Cardiac-CT is accurate as MR for LV and RV volume assessment. • Cardiac-CT can provide accurate evaluation of coronary arteries and LV and RV function.
journal_name
Eur Radioljournal_title
European radiologyauthors
Maffei E,Messalli G,Martini C,Nieman K,Catalano O,Rossi A,Seitun S,Guaricci AI,Tedeschi C,Mollet NR,Cademartiri Fdoi
10.1007/s00330-011-2345-6subject
Has Abstractpub_date
2012-05-01 00:00:00pages
1041-9issue
5eissn
0938-7994issn
1432-1084journal_volume
22pub_type
杂志文章abstract:OBJECTIVE:The purpose was to identify distinguishing CT features of pathologically diagnosed asbestosis, and correlate diagnostic confidence with asbestos body burden. METHODS:Thirty-three workers (mean age at CT: 73 years) with clinical diagnoses of asbestosis, who were autopsied (n = 30) or underwent lobectomy (n = ...
journal_title:European radiology
pub_type: 杂志文章,多中心研究
doi:10.1007/s00330-015-3973-z
更新日期:2016-05-01 00:00:00
abstract::Although multimodality therapy for high-grade gliomas is making some improvement in outcome, most patients will still die from their disease within a short time. We need tools that allow treatments to be tailored to an individual. In this study we used diffusion tensor imaging (DTI), a technique sensitive to subtle di...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-006-0561-2
更新日期:2007-07-01 00:00:00
abstract::Percutaneous thrombectomy (PT) is an established technique for the removal of acute thrombus in occluded arteries, veins and vascular grafts. Percutaneous thrombectomy can be used as an adjunctive treatment to other methods of thrombus removal such as thrombolysis or as sole therapy. The two main methods are percutane...
journal_title:European radiology
pub_type: 杂志文章,评审
doi:10.1007/s003300101014
更新日期:2002-01-01 00:00:00
abstract::The aim of this study was to find out by radiological analysis whether it is possible to prevent interval cancers in screening programmes without a concomitant increase in false positives. Re-scrutiny of all mammograms of 544 interval cancers was implemented. Blinded re-scrutiny of screening mammograms of 390 interval...
journal_title:European radiology
pub_type: 临床试验,杂志文章,多中心研究,随机对照试验
doi:10.1007/s003300050452
更新日期:1998-01-01 00:00:00
abstract:OBJECTIVES:Opportunistic screening for osteoporosis using computed tomography (CT) examinations that happen to visualise the spine can be used to identify patients with osteoporosis. We sought to verify the diagnostic performance of vertebral Hounsfield unit (HU) measurements on routine CT examinations for diagnosing o...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-014-3584-0
更新日期:2015-07-01 00:00:00
abstract:OBJECTIVE:To assess the accuracy of a scout dose of holmium-166 poly(L-lactic acid) microspheres ((166)Ho-PLLA-MS) in predicting the distribution of a treatment dose of (166)Ho-PLLA-MS, using single photon emission tomography (SPECT). METHODS:A scout dose (60 mg) was injected into the hepatic artery of five pigs and S...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-009-1613-1
更新日期:2010-04-01 00:00:00
abstract:OBJECTIVE:To assess the radiation dose received by the radiologist when performing wire localisation for axillary radio-isotope sentinel node imaging-guided biopsy in patients with impalpable breast cancers treated with breast-preserving excision. When wire placement follows radio-isotope sentinel node imaging (RSNI) t...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-009-1594-0
更新日期:2010-03-01 00:00:00
abstract::Many disease processes manifest either primarily or secondarily by cranial nerve deficits. Neurologists, ENT surgeons, ophthalmologists and maxillo-facial surgeons are often confronted with patients with symptoms and signs of cranial nerve dysfunction. Seeking the cause of this dysfunction is a common indication for i...
journal_title:European radiology
pub_type: 杂志文章,评审
doi:10.1007/s00330-006-0575-9
更新日期:2007-08-01 00:00:00
abstract:OBJECTIVES:We assessed the additional value of contrast-enhanced CT versus US for evaluation of acute cervical inflammatory masses and choosing treatment strategy. METHODS:We retrospectively reviewed 210 files of paediatric patients admitted with an acute inflammatory neck mass from 2005 to 2008 (M:F = 108:102, mean a...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-009-1563-7
更新日期:2010-02-01 00:00:00
abstract:OBJECTIVES:To image the pedunculopontine tegmental nucleus (PPN), a deep brain stimulation (DBS) target for Parkinson disease, using MRI with validated results. METHODS:This study used the MP2RAGE sequence with high resolution and enhanced grey-white matter contrast on a 7-T ultra-high-field MRI system to image the PP...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-017-5299-5
更新日期:2018-09-01 00:00:00
abstract::Cavernous angiomas are vascular malformations composed of slowly perfused, sinusoidal vessels which can be located in any part of the central nervous system. Whereas diagnosis is mostly straightforward in typical cases, some lesions may present in unusual locations or with unusual imaging characteristics. Because of t...
journal_title:European radiology
pub_type: 杂志文章
doi:
更新日期:2003-12-01 00:00:00
abstract:OBJECTIVE:To determine the value of perfusion computed tomography (CT-p) in the quantitative assessment of tumour-related neoangiogenesis processes in patients with hepatocellular carcinoma (HCC). MATERIALS AND METHODS:Fifty-two biopsy proven HCC lesions were examined with dynamic CT investigations during injection of...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-011-2307-z
更新日期:2012-04-01 00:00:00
abstract:OBJECTIVE:To evaluate the performance of a computer-aided algorithm for automated stenosis detection at coronary CT angiography (cCTA). METHODS:We investigated 59 patients (38 men, mean age 58 +/- 12 years) who underwent cCTA and quantitative coronary angiography (QCA). All cCTA data sets were analyzed using a softwar...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-009-1644-7
更新日期:2010-05-01 00:00:00
abstract::The aim of this study was to compare the performance of the CT and the water-soluble contrast enema (CE) in the diagnosis and the severity of acute left-colonic diverticulitis, and to recognize the impact of CT during the acute phase and after a first acute episode successfully treated medically. From 1986 to 1997, al...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-001-1143-y
更新日期:2002-05-01 00:00:00
abstract:OBJECTIVES:Post-imaging mathematical prediction models (MPMs) provide guidance for the management of solid pulmonary nodules by providing a lung cancer risk score from demographic and radiologists-indicated imaging characteristics. We hypothesized calibrating the MPM risk score threshold to a local study cohort would r...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-019-06168-x
更新日期:2019-10-01 00:00:00
abstract::Our objective was to evaluate the hemolytic effect of stents and stent grafts in an in vitro flow model. The model consisted of silicone tubings. Pulsatile flow was delivered at 1170 ml/min. Diluted packed erythrocytes were used (hematocrit of 33%). The Palmaz, MegaLink stents or Passager, Hemobahn stent grafts were p...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-002-1664-z
更新日期:2003-06-01 00:00:00
abstract:OBJECTIVES:To investigate whether contralateral parenchymal enhancement (CPE) on MRI during neoadjuvant endocrine therapy (NET) is associated with the preoperative endocrine prognostic index (PEPI) of ER+/HER2- breast cancer. METHODS:This retrospective observational cohort study included 40 unilateral ER+/HER2- breast...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-020-07058-3
更新日期:2020-12-01 00:00:00
abstract::The purpose of the study was to evaluate a semiautomatic analysis tool for assessing global left ventricular myocardial function with multislice computed tomography (MSCT). We examined 33 patients with MSCT using 16x0.5 mm detector collimation and magnetic resonance imaging (MRI) on a 1.5-T scanner. MSCT data were ana...
journal_title:European radiology
pub_type: 临床试验,杂志文章
doi:10.1007/s00330-005-2817-7
更新日期:2006-01-01 00:00:00
abstract::Primary and metastatic tumors of the liver can be treated successfully with transcatheter chemoembolization (TACE) during selective arterial catheterism. Arteritis is a possible referred side effect which can lead to tortuosity of the arteries, stenosis and occlusion of vessels. In our hospitals 117 consecutive patien...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s003300050159
更新日期:1997-01-01 00:00:00
abstract:PURPOSE:3D-FLAIR sequences with delayed acquisition after contrast medium injection have demonstrated new insights into blood-labyrinthine barrier (BLB) abnormalities in various diseases. The aim of this study was to assess the BLB in patients referred with unilateral acute vestibular syndrome (UAVS). MATERIALS AND ME...
journal_title:European radiology
pub_type: 杂志文章,多中心研究
doi:10.1007/s00330-018-5825-0
更新日期:2019-06-01 00:00:00
abstract:OBJECTIVE:To assess reduced volumes of contrast agent on image quality for coronary computed tomography angiography (CCTA) by using single-beat cardiac imaging with 320-slice CT.
MATERIALS AND METHODS:Forty consecutive male patients (mean age: 55.8 years) undergoing CCTA with body weight journal_title:European radiology pub_type: 杂志文章 doi:10.1007/s00330-009-1692-z 更新日期:2010-06-01 00:00:00
abstract::The purpose of this study was to assess the image quality and diagnostic value of MR urography in detecting abnormalities of the urinary collecting system relevant for the preoperative evaluation of living renal donors. Study subjects were selected from the existing intravenous urography (IVU) reports: 18 consecutive ...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-002-1438-7
更新日期:2002-08-01 00:00:00
abstract:OBJECTIVES:The purpose of our study was to assess whether there is a potential additional value of real-time virtual sonography (RVS) to second-look ultrasound (US) examination and biopsy for breast lesions identified on MRI alone. METHODS:A retrospective review of the records of 70 consecutive patients (78 lesions) w...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-015-3892-z
更新日期:2016-04-01 00:00:00
abstract:OBJECTIVES:To investigate the diagnostic performance of reduced-dose CT with a hybrid iterative reconstruction (IR) algorithm for the detection of hypervascular liver lesions. METHODS:Thirty liver phantoms with or without simulated hypervascular lesions were scanned with a 320-slice CT scanner with control-dose (40 mA...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-016-4687-6
更新日期:2017-07-01 00:00:00
abstract:OBJECTIVES:Accurately predicting the WHO classification of thymomas is urgently needed to optimize individualized therapeutic strategies. We aimed to develop and validate a combined radiomics nomogram for personalized prediction of histologic subtypes in patients with thymomas. METHODS:A total of 182 thymoma patients ...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-020-07074-3
更新日期:2021-01-01 00:00:00
abstract:OBJECTIVE:To develop a visual rating scale for posterior atrophy (PA) assessment and to analyse whether this scale aids in the discrimination between Alzheimer's disease (AD) and other dementias. METHODS:Magnetic resonance imaging of 118 memory clinic patients were analysed for PA (range 0-3), medial temporal lobe atr...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-011-2205-4
更新日期:2011-12-01 00:00:00
abstract:PURPOSE:To evaluate the inter-/intra-observer agreement of BI-RADS-based subjective visual estimation of the amount of fibroglandular tissue (FGT) with magnetic resonance imaging (MRI), and to investigate whether FGT assessment benefits from an automated, observer-independent, quantitative MRI measurement by comparing ...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-016-4274-x
更新日期:2016-11-01 00:00:00
abstract:OBJECTIVE:The purpose of study was to develop a computer-simulated liver phantom for hepatic CT studies. A computer-simulated liver phantom was mathematically constructed on a computer workstation. MATERIALS AND METHODS:The computer-simulated phantom was calibrated using real CT images acquired by an actual four-detec...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-005-0012-5
更新日期:2006-04-01 00:00:00
abstract::Our aim was to evaluate whether it is possible to visualize slow flow within a small catheter placed inside a living animal. We used a flow-sensitive, single-shot turbo spin-echo (SS-TSE) MRI sequence, developed in house, based on diffusion-weighted (DW) techniques. Four anesthetized pigs were used as models. A plasti...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-003-2212-1
更新日期:2004-09-01 00:00:00
abstract:OBJECTIVE:To evaluate the relationship between multiple MR perfusion parameters and symptoms of patients with osteoid osteomas after percutaneous laser therapy. METHODS:MR perfusion studies of 20 patients diagnosed with an osteoid osteoma, treated with CT-guided percutaneous laser therapy, were retrospectively evaluat...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-013-2867-1
更新日期:2013-09-01 00:00:00