Generalized predictive equation for hematocrit by biological impedancemetry.

Abstract:

:Bioelectrical impedancemetry (BIA) has been used to evaluate hemorheological parameters from whole body measurements. In a previous study, we have determined a set of predictive equations for hematocrit, whole blood viscosity and plasma viscosity in athletes. In another previous study, we also found other predictive equations in sedentary lean and obese subjects. This study aims at developing more generalized BIA-derived predictive equations for hemorheological parameters in both sedentary and trained individuals. 72 subjects, either athletes, sedentary obese or insulin resistant patients (33.57+/-1.60 yr; 80.81+/-2.06 kg; 171.03+/-1.19 cm) were enrolled into the study. Body composition was assessed with a multifrequency bioelectrical impedancemeter (Dietosystem Human IM Scan) using low intensity at the following frequencies: 1, 5, 10, 50 and 100 kHz. Viscometric measurements were done at 1000 s(-1) with a falling ball viscosimeter (MT 90 Medicatest). Hematocrit (Hct) was measured with microcentrifuge. Hematocrit was correlated with impedance (Z) measurements at 50 kHz (r=-0.591, p=0.01). A generalized empirical predictive equation can thus be proposed. These findings further suggest that one can predict hematocrit in the general population with whole body electric properties.

authors

Varlet-Marie E,Brun JF

subject

Has Abstract

pub_date

2004-01-01 00:00:00

pages

471-5

issue

3-4

eissn

1386-0291

issn

1875-8622

journal_volume

30

pub_type

杂志文章
  • Doppler ultrasonography and contrast-enhanced ultrasonography to evaluate liver allograft discard: A pilot prospective study.

    abstract:BACKGROUND:Broad hemodynamic changes, is believed to have a profoundly damaging effect on donor livers after brain death (DBD) or cardiac death (DCD). It remains unclear whether Doppler ultrasonography (DUS) and contrast-enhanced ultrasonography (CEUS), the imaging modalities to evaluate perfusion, could provide more i...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:10.3233/CH-200950

    authors: Zhang HJ,Zheng BW,Gu SJ,Wu T,Wu LL,Lian YF,Tong G,Yi SH,Ren J

    更新日期:2020-09-08 00:00:00

  • Rheological blood behavior is not only influenced by cardiovascular risk factors but also by aging itself. Research into 927 healthy Spanish Mediterranean subjects.

    abstract::It is not well-established whether the alterations that the hemorheological profile undergoes with aging are an effect of concomitant cardiovascular risk factors or are due to age itself. To clarify this issue, we investigated the effect of age on blood rheology in a population of 927 healthy subjects from eastern Spa...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:10.3233/CH-131734

    authors: Vayá A,Alis R,Romagnoli M,Pérez R,Bautista D,Alonso R,Laiz B

    更新日期:2013-01-01 00:00:00

  • Evolution of blood rheology and its relationship to pulmonary hemodynamic during the first days of exposure to moderate altitude.

    abstract::Blood rheology and hemodynamic parameters have never been explored together during acclimatization to altitude. This study aimed to investigate changes in blood rheology parameters and pulmonary hemodynamics during the first days of real moderate altitude exposure.Seventeen athletes were tested at sea-level, 20 hours ...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:10.3233/CH-190671

    authors: Raberin A,Nader E,Ayerbe JL,Mucci P,Connes P,Durand F

    更新日期:2020-01-01 00:00:00

  • Shear-wave elastography of the testis in the healthy man - determination of standard values.

    abstract:PURPOSE:Real-time shear-wave elastography (SWE) is a newly developed technique for the sonographic quantification of tissue elasticity, which already is used in the assessment of breast and thyroid lesions. Due to limited overlying tissue, the testes are ideally suited for assessment using shear wave elastography. To o...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:10.3233/CH-162046

    authors: Trottmann M,Marcon J,D'Anastasi M,Bruce MF,Stief CG,Reiser MF,Buchner A,Clevert DA

    更新日期:2016-01-01 00:00:00

  • Relationships among body composition, hemorheology and exercise performance in rugbymen.

    abstract::We investigated relationships among body composition, blood rheology, and exercise performance in 14 rugbymen (19-31 yr, weight 65.8-109.2 kg, height 1.7-1.96 m, body mass index 21.7-33.1 kg/m2) who underwent a standardized submaximal exercise session on cycloergometer corresponding to 225 kJ over 30 min. The rheologi...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:

    authors: Bouix D,Peyreigne C,Raynaud E,Monnier JF,Micallef JP,Brun JF

    更新日期:1998-11-01 00:00:00

  • Ultrasound elastography for the detection of capsular fibrosis in breast implants: First results.

    abstract:BACKGROUND:Capsular contractures around breast implants usually develop leading to pain and aesthetically inadequate results and ultimately often requires the replacement of the implants. Textured silicone implants are the most commonly placed implant, but polyurethane-coated implants are increasingly being used in an ...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:10.3233/CH-200875

    authors: Jung E,Hösl V,von Fraunberg S,Jung F,Prantl L

    更新日期:2020-09-08 00:00:00

  • Contrast enhanced ultrasound (CEUS) to assess pleural pulmonal changes in severe COVID-19 infection: First results.

    abstract:AIM:Use of contrast enhanced ultrasound (CEUS) in severe cases of COVID-19 infection to assess pulmonary changes near the pleura. MATERIAL AND METHODS:Bedside examinations by an experienced intensive care unit examiner using a multi-frequency probe (C1-6 MHz) with B-mode and CEUS to assess pleural-near changes in seve...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:10.3233/CH-209005

    authors: Jung EM,Stroszczynski C,Jung F

    更新日期:2020-01-01 00:00:00

  • Blood cells and vascular cell interactions in diabetes.

    abstract::The diabetic vasculopathy is one of the major complications responsible for the high incidence of arteriopathy, coronary ischemia and renal failure. Several hypothesis have been formulated to explain the vascular abnormalities. We recently showed that advanced glycation end products (AGE) have a pivotal role in the ge...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章,评审

    doi:

    authors: Wautier JL,Wautier MP

    更新日期:2001-01-01 00:00:00

  • Effects of cardiotonic pill on RBC rheologic abnormalities in HFD-induced mice and LPL deficient mice.

    abstract::The lipoprotein lipase deficient (LPL-/-) mice and high fat-diet (HFD) induced hypertriglyceridemic mice were used to investigate the effects of cardiotonic pill (CP) on RBC rheologic abnormalities. Mice were randomly divided into the following five groups: the control group; the untreated HFD group; the untreated LPL...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:

    authors: Wang XW,Guo J,Wang XF,Chen XP,Wen ZY

    更新日期:2008-01-01 00:00:00

  • Challenges for microcirculation research in developing countries.

    abstract:BACKGROUND:Microvascular dysfunction is a main contributor to morbidity and mortality worldwide. Sophisticated technical tools (e.g. miniaturized hardware, automated software), along with skilled personnel are the prerequisite for quantitative observations of the microvasculature. OBJECTIVE:This review aimed to get an...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章,评审

    doi:10.3233/CH-190611

    authors: Islam S,Ahmed N,Rivu SF,Khalil M,Tanjia N,Lehmann C

    更新日期:2019-01-01 00:00:00

  • Effect of radiographic contrast media (Iodixanol, Iopromide) on hemolysis.

    abstract::Radiographic contrast media can lead to drastic changes of the morphology of erythrocytes. The change of the erythrocyte morphology is associated with a decreased deformability possibly resulting from distinctions in the loss of constituents of the membrane cytoskeleton. However, it is unclear whether there is an intr...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:10.3233/CH-141879

    authors: Gerk U,Krüger A,Franke RP,Jung F

    更新日期:2014-01-01 00:00:00

  • Vascularized transfer of two coherent toe joints in simultaneously reconstructing MCP and PIP of a mutilated finger.

    abstract:BACKGROUND:The reconstruction of metacarpal- and interphalangeal joints after severe hand injuries has been proven to be challenging. Commonly used procedures like arthrodesis, amputation or ray resection of the finger compromise the functionality of the injured finger. Especially for young patients, the restoration of...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:10.3233/CH-168100

    authors: Bachleitner K,Blank B,Klein S,Geis S,Aung T,Prantl L,Dolderer JH

    更新日期:2016-01-01 00:00:00

  • The rheological changes after cesarean section: The influence of low molecular weight or unfractionated heparin on the rheological properties of blood.

    abstract::Thromboembolic complications remain an important cause of maternal mortality. The present recommendations favour for prophylaxis unfractionated (UFH) and low molecular weight heparin (LMWH). We investigated 150 pregnant women before and after cesarean section in three randomized groups. Fifty women received no prophyl...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章,随机对照试验

    doi:

    authors: Heilmann L,Rath W,Pollow K,Bick RL

    更新日期:2007-01-01 00:00:00

  • Contrast enhanced ultrasound (CEUS) and time intensity curve (TIC) analysis in compartment syndrome: first results.

    abstract:OBJECTIVE:Purpose of this study was to monitor changes of microcirculation in acute compartment syndrome using contrast enhanced ultrasound (CEUS) and to assess the modified perfusion with a special quantification software. METHODS:8 patients with trauma of the lower limb or the upper extremity were enrolled after acu...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:10.3233/CH-2011-1438

    authors: Geis S,Gehmert S,Lamby P,Zellner J,Pfeifer C,Prantl L,Jung EM

    更新日期:2012-01-01 00:00:00

  • Micro-rheological changes during experimental acute pancreatitis in the rat.

    abstract::Although microcirculatory disturbances play pivotal role in the pathomechanism of acute pancreatitis (AP), very few papers can be found which had been tested any of hemorheological parameters. The aim of our study was to analyze the hemorheological changes in cerulein-induced experimental acute pancreatitis in rat in ...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:10.3233/CH-2012-1531

    authors: Kotan R,Nemeth N,Kiss F,Posan J,Miszti-Blasius K,Toth L,Furka I,Miko I,Sapy P,Szentkereszty Z

    更新日期:2012-01-01 00:00:00

  • Study on the hemorheological parameters of oldest-old residents in the East-Hungarian city, Debrecen.

    abstract::The aim of this study was to assess social and health status of residents older than 90 years in an East-Hungarian city. The investigation involved 70 subjects, measuring routine laboratory parameters and plasma viscosity. Mean cholesterol, erythrocyte sedimentation rate (ESR), collagen cross links and plasma viscosit...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:

    authors: Kovács A,Szikszai Z,Várady E,Imre S

    更新日期:2006-01-01 00:00:00

  • Sex-dependent differences in rheological properties and the relation of blood viscosity to erythrocyte aggregation indices among morbidly obese patients.

    abstract::Some studies indicate that obesity is associated with rheological disturbances. Because there are usually sex differences in the type of obesity we decided to evaluate rheological differences between male and female obese patients. We studied 18 morbidly obese men, mean age 43.66 +/- 11.32 years, mean body mass index ...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:10.3233/CH-2010-1275

    authors: Wiewióra M,Sosada K,Slowinska L,Piecuch J,Glück M,Zurawinski W,Turczynski B

    更新日期:2010-01-01 00:00:00

  • Erythrocyte deformability in morbid obesity before bariatric surgery. Influence of abdominal obesity.

    abstract::Although there are several studies dealing with erythrocyte deformability (ED) in obese patients, research on this topic in morbidly obese subjects is scarce. In these studies ED seems to be decreased, although the cause remains unknown. A case-control study in 76 morbid obese subjects (23 women and 53 men, aged 44 ± ...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:10.3233/CH-2010-1357

    authors: Vayá A,Cámara R,Hernádez-Mijares A,Romagnoli M,Solá E,Corella D,Laiz B

    更新日期:2010-01-01 00:00:00

  • The influence of calcium ions and ionophore A23187 on microrheological characteristics of erythrocytes by new model ektacytometry.

    abstract::After rabbit's erythrocytes were treated with different concentrations of intercellular Ca2+ and ionophore A23187 respectively, the orientation index (DI)or, and small deformation index (DI)d of rabbit erythrocytes were measured by new model ektacytometry. The results demonstrated that (DI)or and (DI)d decreased while...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:

    authors: Chunyi W,Yanjun Z,Weibo K

    更新日期:2001-01-01 00:00:00

  • Multipolar RFA of the liver: Influence of intrahepatic vessels on ablation zones and appropriateness of CECT in detecting ablation dimensions - Results of an in-vivo porcine liver model.

    abstract:BACKGROUND:Radiofrequency ablation (RFA) is an important treatment option for hepatic tumors and metastases. Post-ablation recurrence rates are reported up to 36.5 percent and seem to depend on tumor size, intrahepatic localization of tumors and adjacent hepatic vessels. Multipolar RFA has the potential to overcome/red...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:10.3233/CH-189313

    authors: Vahldiek JL,Erxleben C,Bressem KK,Gemeinhardt O,Poch F,Hiebl B,Lehmann KS,Hamm B,Niehues SM

    更新日期:2018-01-01 00:00:00

  • Nitric oxide generated by red blood cells following exposure to shear stress dilates isolated small mesenteric arteries under hypoxic conditions.

    abstract::Red blood cells (RBC) possess a functional nitric oxide synthase (NOS) enzyme located in the cell membrane and cytoplasm. It has previously been observed that shear stress acting on RBC activates NOS and causes enhanced NO export. The aim of the present study was to investigate the physiological importance (e.g., in l...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:10.3233/CH-2012-1618

    authors: Ulker P,Gunduz F,Meiselman HJ,Baskurt OK

    更新日期:2013-01-01 00:00:00

  • Effects of adrenomedullin on the cardiac performance and coronary flow in an isolated perfused rat heart model.

    abstract::The effect of adrenomedullin (AM) on the cardiac performance and coronary flow were studied in an isolated perfused rat heart model based on the modified Langendorff method. The heart rate (HR), electrocardiogram (ECG), left ventricular contraction (LVC) (dP/dt), and coronary flow (CF) were measured before and after t...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:

    authors: Amatyakul S,Patumraj S,Niimi H

    更新日期:2000-01-01 00:00:00

  • Red cell fluidity in hypertension.

    abstract::Rheological findings in essential hypertension are increases in haematocrit, plasma fibrinogen, plasma and whole blood viscosity, and erythrocyte aggregability as well as impaired erythrocyte deformability. Are these abnormalities secondary effects of an increased blood pressure via an increased filtration pressure re...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章,评审

    doi:

    authors: Sandhagen B

    更新日期:1999-01-01 00:00:00

  • Endothelial nitric oxide synthase expression in systemic and pulmonary circulation of streptozotocin induced diabetic rats: comparison using image analysis.

    abstract::To compare the level of endothelial nitric oxide synthase (eNOS) expression produced in heart and lung vascular tissue, the protein content was determined using Western blot analysis with the enhancement of image processing. Heart and lung extracts from 12 and 24 weeks from control (CON) and streptozotocin-induced dia...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:

    authors: Sridulyakul P,Chakraphan D,Bhattarakosol P,Patumraj S

    更新日期:2003-01-01 00:00:00

  • Numerical investigation on red blood cell dynamics in microflow: Effect of cell deformability.

    abstract::The radial dispersion of red blood cells (RBCs) near the vessel wall can significantly affect the transport dynamics in small vessels. The radial dispersion of RBCs is mainly caused by collisions between RBCs and this can be enhanced by aggregation. The objective of this study is to numerically investigate on the effe...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:10.3233/CH-16128

    authors: Ju M,Leo HL,Kim S

    更新日期:2017-01-01 00:00:00

  • Asian traditional medicine: from molecular biology to organ circulation.

    abstract::Asian tradition medicine (ATM), such as herbal medicine and acupuncture, has been widely used in the treatment of diseases, but the effects still remain unclear at the level of the microcirculation. Up to now, a variety of approaches have been made to comprehensively evaluate the significance of ATM. Microcirculatory ...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:

    authors: Niimi H,Yuwono HS

    更新日期:2000-01-01 00:00:00

  • Expression of MMPs and TIMPs in primary epithelial cell cultures of the upper aerodigestive tract seeded on the surface of a novel polymeric biomaterial.

    abstract:INTRODUCTION:Using standard cell biological and biochemical experimental approaches we were able to test the ability of a particular polymer construct to support the adhesion, proliferation, and the cellular acitivity of pharyngeal cells. The delicate balance between Matrix Metalloproteinases (MMPs) and their endogenou...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:

    authors: Rickert D,Lendlein A,Kelch S,Moses MA,Franke RP

    更新日期:2005-01-01 00:00:00

  • Analysis of microcirculation measurements by novice users trained by a standardized interactive tutorial: An inter-observer variability study.

    abstract::Excessive time for analysis may impede microcirculatory studies with large amounts of video data. Engaging more personnel in the analyses seems to be a rational approach in that scenario and could shorten the time-interval between capturing images and obtaining results. Our hypothesis was that novice users would be ab...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章,多中心研究

    doi:10.3233/CH-151958

    authors: Cerny V,Abdo I,George RB,Maddison L,Sharawi N,Lehmann C

    更新日期:2016-01-01 00:00:00

  • Differences of standard values of Supersonic shear imaging and ARFI technique - in vivo study of testicular tissue.

    abstract:PURPOSE:To investigate the difference of standard values of Supersonic shear imaging (SSI) and Acoustic Radiation Force Impulse (ARFI) technique in the evaluation of testicular tissue stiffness in vivo. MATERIALS AND METHODS:58 healthy male testes were examined using B-mode sonography and ARFI and SSI. B-mode sonograp...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:10.3233/CH-168039

    authors: Trottmann M,Rübenthaler J,Marcon J,Stief CG,Reiser MF,Clevert DA

    更新日期:2016-01-01 00:00:00

  • Effects of storage duration and temperature of human blood on red cell deformability and aggregation.

    abstract::Blood samples used in hemorheological studies may be stored for a period of time, the effects of storage have yet to be fully explored. This study evaluated the effects of storage temperature (i.e., 4 degrees C or 25 degrees C) and duration on RBC deformability and aggregation for blood from healthy controls and from ...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:10.3233/CH-2009-1178

    authors: Uyuklu M,Cengiz M,Ulker P,Hever T,Tripette J,Connes P,Nemeth N,Meiselman HJ,Baskurt OK

    更新日期:2009-01-01 00:00:00