Abstract:
PURPOSE:To assess the agreement between ablative margin (AM) predicted by preablation three-dimensional ultrasonography (3D-US) and AM measured on postablation computed tomography (CT)/magnetic resonance (MR) images. METHODS:Sixty patients with 73 hepatocellular carcinoma nodules were enrolled. 3D-US data were collected immediately after puncture by the electrode before ablation. The maximum distance from the electrode to the edge of the tumor in the plane perpendicular to the electrode (C-plane) was defined as "a" and the diameter of the ablation zone as "b". We classified predicted AM into "0.5b - a" ≥0 mm as AM(+) or <0 mm as AM(-), and "0.5b - a" ≥3 mm or <3 mm. RESULTS:Forty-eight nodules (66 %) were visualized in the C-plane. There was an agreement between the predicted and measured AMs for 39 (81 %) of the 48 nodules. Local tumor progression was observed in 3 (7%) of 43 nodules with predicted AM(+) and in 2 (40 %) of 5 nodules with predicted AM(-) but was not observed in any of 21 nodules with predicted AM ≥ 3 mm. The local tumor progression rate was significantly lower for nodules with predicted AM(+) compared with predicted AM(-)(p = 0.03), and for nodules with predicted AM ≥ 3 mm compared with predicted AM < 3 mm (p = 0.04). Local progression was detected in 2 (4.7 %) of 42 nodules with a sufficient AM (≥0 mm) on postablation CT/MR images and in 5 (83.3 %) of 6 nodules with an insufficient AM (<0 mm); the difference in progression rate was significant (p = 0.0008). CONCLUSION:3D-US allows prediction of the AM before radiofrequency ablation.
journal_name
Eur J Radioljournal_title
European journal of radiologyauthors
Matsuki Y,Matono T,Koda M,Miyoshi K,Sugihara T,Okano JI,Isomoto Hdoi
10.1016/j.ejrad.2020.109358subject
Has Abstractpub_date
2020-12-01 00:00:00pages
109358eissn
0720-048Xissn
1872-7727pii
S0720-048X(20)30547-7journal_volume
133pub_type
杂志文章abstract:OBJECTIVE:To determine if concomitant CT-guided biopsy and percutaneous fiducial seed placement in the lung can be performed in a selective patient population without increased complication or decreased success rates compared to either procedure alone. MATERIALS AND METHODS:An IRB approved retrospective analysis of 28...
journal_title:European journal of radiology
pub_type: 杂志文章,随机对照试验
doi:10.1016/j.ejrad.2014.01.006
更新日期:2014-04-01 00:00:00
abstract:OBJECTIVES:Structural and functional changes in pulmonary vessels are prevalent at the initial stages of chronic obstructive pulmonary disease (COPD). These vascular alterations can be assessed using cross-sectional area (CSA) of small pulmonary vessels. However, neither in non-COPD smokers nor in COPD patients it has ...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2013.05.022
更新日期:2013-10-01 00:00:00
abstract:PURPOSE:This study aims to demonstrate pulmonary alterations (PA) in patients with Behcet's disease by using CT. MATERIALS AND METHODS:CTs of 50 patients with Behcet's disease and 20 others in a control group have been evaluated retrospectively for PA (septal, reticular, nodular, atelectatic opacities). RESULTS:Eight...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2008.01.049
更新日期:2009-05-01 00:00:00
abstract:PURPOSE:This study aimed to compare the quality of abdominal CT angiography (CTA) images obtained using conventional reconstruction algorithms with those obtained using a novel iterative algorithm (forward projected model-based iterative reconstruction solution, FIRST) for evaluating arteries in the abdomen. MATERIALS...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2018.07.015
更新日期:2018-09-01 00:00:00
abstract:PURPOSE:Background parenchymal enhancement (BPE) often affects interpretation of dynamic contrast-enhanced (DCE) MRI. There is limited evidence that reduced BPE is a feature of ultrafast DCE (UF-DCE) MRI. We aimed to evaluate the effect of BPE levels on lesion detectability on UF-DCE MRI in comparison with conventional...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2020.108984
更新日期:2020-08-01 00:00:00
abstract::Automatic computer-assisted detection (auto-CAD) of significant coronary artery disease (CAD) in coronary computed tomography angiography (cCTA) has been shown to have relatively high accuracy. However, to date, scarce data are available regarding the performance of auto-CAD in the setting of acute chest pain. This st...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2012.01.017
更新日期:2012-04-01 00:00:00
abstract:PURPOSE:To evaluate the effect of rectal distension on the quality of anatomical and functional prostate multiparametric (mp) MRI. MATERIALS AND METHODS:Multiparametric (mp) 3T-MRI images of 173 patients were independently evaluated by two radiologists in this retrospective study. Planimetry rectal volumes were derive...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2017.02.029
更新日期:2017-05-01 00:00:00
abstract::A group of 26 patients with carcinoma of the head and neck region was treated by superselective intra-arterial infusion of cisplatin (CDDP)-carboplatin (CBDCA). The tumor locations included the tongue (n = 4), oral base (n = 2), nasopharynx (n = 2), oropharynx (n = 8), hypopharynx (n = 4) and larynx (n = 4). Using the...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/0720-048x(95)00692-j
更新日期:1995-12-15 00:00:00
abstract::As a special subgroup of multiple intracranial aneurysms, mirror aneurysms are located bilaterally on the corresponding intracranial arteries. The current study sought to compare the clinical and demographic features of patients harboring mirror aneurysm, and to elucidate the corresponding risk factors. We performed a...
journal_title:European journal of radiology
pub_type: 杂志文章,多中心研究
doi:10.1016/j.ejrad.2017.09.015
更新日期:2017-11-01 00:00:00
abstract::The purpose of this study was to evaluate the agreement between axial, multiplanar reformatted (MPR) and semi-automated software measurements of pulmonary vein ostial diameters and distance to the first bifurcation. CT examinations of the thorax were retrospectively reviewed in 150 consecutive patients. The pulmonary ...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2008.04.008
更新日期:2009-07-01 00:00:00
abstract:PURPOSE:To assess the effect of parenteral butylscopolamine on magnetic resonance cholangiopancreatography (MRCP) image quality. MATERIALS AND METHODS:The 3D free-breathing respiratory-compensated MRCP images (mean acquisition time 7min) of 94 consecutive non-paired patients (47 with and 47 without 20mg intramuscular ...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2012.11.023
更新日期:2013-04-01 00:00:00
abstract::Digital 'conventional-like' (C-L) and edge-enhanced (E-E) posteroanterior chest roentgenograms of 42 healthy individuals were ranked twice (interval of at least 5 days) in the order of increasing lung parenchymal markings (a total of four rankings). This was done by three radiologists, two residents, one medical stude...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/0720-048x(94)90275-5
更新日期:1994-05-01 00:00:00
abstract:OBJECTIVE:The purpose of this study was to compare the diagnostic accuracy of 64-slice CT with that of invasive angiography in the detection of graft and/or coronary angioplasty stenosis in children who had undergone coronary artery surgery. POPULATION AND METHODS:Fifteen consecutive children (8 male and 7 female; age...
journal_title:European journal of radiology
pub_type: 临床试验,杂志文章
doi:10.1016/j.ejrad.2008.06.008
更新日期:2009-09-01 00:00:00
abstract:OBJECTIVE:Renal perfusion imaging may provide information about the hemodynamic significance of a renal artery stenosis and could improve noninvasive characterization when combined with angiography. It was proposed previously that diffusion sequences could provide useful perfusion indices based on the intravoxel incohe...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/s0720-048x(97)01161-3
更新日期:1998-02-01 00:00:00
abstract::Glomerular filtration rate (GFR) describes the flow rate of filtered fluid through the kidney, and is considered to be the reference standard in the evaluation of renal function. There are many ways to test the GFR clinically, such as serum creatinine concentration, blood urea nitrogen and SPECT renography, however, t...
journal_title:European journal of radiology
pub_type: 杂志文章,评审
doi:10.1016/j.ejrad.2015.05.009
更新日期:2015-08-01 00:00:00
abstract::NMR examinations were performed on a total of 109 patients using a resistive magnet. In 67 patients various organs and tissues of the face and neck the trunk and the limbs were evaluated in axial, sagittal and coronal planes. The use of more than one sequence time is essential for adequate representation of the anatom...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:
更新日期:1983-02-01 00:00:00
abstract:AIM:The atrium septum is tilted in heart. There is an angle between atrium septum and the cross section of body, which is called tilt angles of atrium septum (TAAS) in this study, however this angle has not been specifically mentioned in literatures. In this article TAAS was measured and analysed on axial images of con...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2011.01.040
更新日期:2012-01-01 00:00:00
abstract:OBJECTIVE:To evaluate the technical success and immediate complication rates of temporary internal jugular vein (IJV) haemodialysis catheter placement in normal and high-risk patients. METHODS AND MATERIALS:Two-hundred and twenty temporary internal jugular vein catheters inserted under ultrasound guidance in 172 patie...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2004.10.004
更新日期:2005-07-01 00:00:00
abstract::Two principally different 1000-line CRT (cathode ray tube) monitors connected to a digital image intensifier system for chest radiography were compared in terms of image quality and viewing comfort. Image quality was assessed by means of ROC analysis. Five observers tried to find simulated pathology positioned over th...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/0720-048x(96)00750-4
更新日期:1996-06-01 00:00:00
abstract::This retrospective study aimed to evaluate the feasibility and effectiveness of radiofrequency ablation (RFA) in patients with solitary kidney for the treatment of renal cell carcinoma (RCC). Within 2 years 10 patients (seven males, three females; age 65+/-8 years) were treated. All patients had a history of nephrecto...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2008.12.015
更新日期:2010-03-01 00:00:00
abstract:BACKGROUND:Biopsy with demonstration of the infectious organism is the gold standard for diagnosing spondylodiscitis. The purpose of this study is to evaluate the positive culture rate of image-guided percutaneous biopsy in cases of radiologically suspected and unsuspected spinal osteomyelitis and to assess the role of...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2011.01.125
更新日期:2012-05-01 00:00:00
abstract:OBJECTIVES:To compare the assessment of global and regional left ventricular (LV) function using 64-slice multislice computed tomography (MSCT), 2D echocardiography (2DE) and cardiac magnetic resonance (CMR). METHODS:Thirty-two consecutive patients (mean age, 56.5+/-9.7 years) referred for evaluation of coronary arter...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2007.03.008
更新日期:2008-01-01 00:00:00
abstract::The different features of 821 acoustic shadows recorded during abdominal US examinations were analysed to find out whether any of the features may be used in routine work to help to identify the often invisible structure casting the shadow. A constant shadow with closely spaced high level reverberation echoes is stron...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:
更新日期:1985-05-01 00:00:00
abstract:OBJECTIVE:To describe imaging of typical conditions and diseases in the neonatal genito-urinary (GU) tract. METHOD:The use, the applications, and typical findings using standard imaging techniques (e.g., ultrasound, US, voiding cystourethrography, VCUG) are described, with emphasis on technical aspects, indications, a...
journal_title:European journal of radiology
pub_type: 杂志文章,评审
doi:10.1016/j.ejrad.2006.07.022
更新日期:2006-11-01 00:00:00
abstract:BACKGROUND:To investigate the diagnostic value of shear wave elastography (SWE) in identifying cervical small lymph node metastases in nasopharyngeal carcinoma (NPC) patients. MATERIALS AND METHODS:This prospective study was approved by the local institutional review board. From July 2014 to March 2016, 114 sLNs from ...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2018.03.006
更新日期:2018-06-01 00:00:00
abstract:OBJECTIVES:To investigate the feasibility of implementing quantitative T1-perfusion in the routine MRA-protocol and to obtain a first experience in normals and pathology. MATERIALS AND METHODS:For perfusion imaging, IR-prepared FLASH (one 4 mm slice at mid-renal level, TR 4.4 ms, TE 2.2 ms, TI 180 ms, FA 50 degrees , ...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2007.11.033
更新日期:2009-03-01 00:00:00
abstract:PURPOSE:To evaluate the pattern and risks for intrahepatic recurrence after percutaneous radiofrequency (RF) ablation for hepatocellular carcinoma (HCC). MATERIALS AND METHODS:We studied 62 patients with 72 HCCs (< or =4 cm) who were treated with percutaneous RF ablation. The mean follow-up period was 19.1 months (6.0...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2006.03.007
更新日期:2006-09-01 00:00:00
abstract::The purpose of this study is to clarify the prevalence, spectrum of associated tumors and the diagnostic value of the linear meningeal thickening and enhancement adjacent to a peripherally located cranial mass "dural tail sign"(DTS) in contrast enhanced magnetic resonance imaging (MRI). In this prospective descriptive...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2006.04.003
更新日期:2006-10-01 00:00:00
abstract::A survey of present opinions on the safety of diagnostic ultrasound applications is presented together with some data on output levels. Physical mechanisms involved in potential adverse effects are described. Labelling requirements of the equipment are defined and specified. These requirements are contained in a recen...
journal_title:European journal of radiology
pub_type: 杂志文章,评审
doi:
更新日期:1989-02-01 00:00:00
abstract::After creating a MR pulse sequence, called MR-myelography, the purpose of the study was to evaluate the value of this sequence in comparison to conventional myelography. Twenty consecutive patients were examined with conventional and MR-myelography concerning the clinical questions of chronic lumbago, spinal canal ste...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/0720-048X(95)00730-E
更新日期:1996-02-01 00:00:00