The value of shear wave elastography in predicting for undiagnosed small cervical lymph node metastasis in nasopharyngeal carcinoma: A preliminary study.

Abstract:

BACKGROUND:To investigate the diagnostic value of shear wave elastography (SWE) in identifying cervical small lymph node metastases in nasopharyngeal carcinoma (NPC) patients. MATERIALS AND METHODS:This prospective study was approved by the local institutional review board. From July 2014 to March 2016, 114 sLNs from 62 newly diagnosed NPC patients (47 men, 15 women) were assessed. Target small lymph nodes (sLNs), which were undiagnosed by magnetic resonance imaging (MRI), were defined as scattered cervical lymph nodes that had no evidence of central necrosis or extracapsular spread and exhibited a maximum transverse diameter ≥5 mm and <10 mm in MRI. The mean (Emean), minimum (Emin) and maximum (Emax) of the elasticity indices (EIs) were measured by SWE at the stiffest part of the sLN (kPa). Biopsy pathology was served as the reference standard. Diagnostic performances were assessed using receiver operating curve (ROC) analysis on a node-by-node basis. RESULTS:Of the 114 small cervical lymph nodes, 88 (77.2%) were benign, and 26 (22.8%) were malignant. All SWE EIs were significantly higher in malignant sLNs than in benign sLNs (p < 0.001). Emean exhibited the highest diagnostic value (area under the curve = 0.879 ± 0.036) (p < 0.001) and the corresponding sensitivity, specificity, positive predictive value, negative predictive value and accuracy of 84.6%, 83.0%, 59.5%, 94.8% and 83.3%, respectively. The intra-observer reproducibility of all SWE EIs were significant, with intra-class correlation coefficient (ICC) of 0.745 in Emean, 0.716 in Emax and 0.702 in Emin. CONCLUSION:Shear wave elastography is an optional supplementary imaging modality to routine MRI examination to diagnose cervical lymph nodes in NPC patients.

journal_name

Eur J Radiol

authors

Chen BB,Li J,Guan Y,Xiao WW,Zhao C,Lu TX,Han F

doi

10.1016/j.ejrad.2018.03.006

subject

Has Abstract

pub_date

2018-06-01 00:00:00

pages

19-24

eissn

0720-048X

issn

1872-7727

pii

S0720-048X(18)30091-3

journal_volume

103

pub_type

杂志文章
  • Elemental distribution mapping on breast tissue samples.

    abstract::The main of this work is to determine the elemental and absorption distribution map in breast tissue samples by X-ray fluorescence and X-ray transmission microtomography. The experiments were performed at the X-ray fluorescence beamline (D09B-XRF) in the Brazilian Synchrotron Light Source (LNLS), Campinas, Brazil. A q...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2008.04.047

    authors: Pereira GR,Rocha HS,Anjos MJ,Farias PC,Pérez CA,Lopes RT

    更新日期:2008-12-01 00:00:00

  • Radiation exposure in CT-guided interventions.

    abstract:PURPOSE:To investigate radiation exposure in computed tomography (CT)-guided interventions, to establish reference levels for exposure, and to discuss strategies for dose reduction. MATERIALS AND METHODS:We analyzed 1576 consecutive CT-guided procedures in 1284 patients performed over 4.5 years, including drainage pla...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2013.08.035

    authors: Kloeckner R,dos Santos DP,Schneider J,Kara L,Dueber C,Pitton MB

    更新日期:2013-12-01 00:00:00

  • Semi-automated volumetric analysis of artificial lymph nodes in a phantom study.

    abstract:PURPOSE:Quantification of tumour burden in oncology requires accurate and reproducible image evaluation. The current standard is one-dimensional measurement (e.g. RECIST) with inherent disadvantages. Volumetric analysis is discussed as an alternative for therapy monitoring of lung and liver metastases. The aim of this ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2010.10.019

    authors: Fabel M,Biederer J,Jochens A,Bornemann L,Soza G,Heller M,Bolte H

    更新日期:2011-12-01 00:00:00

  • Functional renal perfusion imaging with colour mapping: is it a useful adjunct to spiral CT of in the assessment of abdominal aortic aneurysm (AAA)?

    abstract:AIM:To ensure optimal timing with pre-operative spiral CT for abdominal aortic aneurysms (AAA), an initial 'timing' single level CT is commonly performed with a small bolus of contrast. This can be exploited to obtain adjunct functional information on renal perfusion. We have investigated the potential of this to measu...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/s0720-048x(99)00014-5

    authors: Blomley MJ,McBride A,Mohammedtagi S,Albrecht T,Harvey CJ,Jäger R,Standfield NJ,Dawson P

    更新日期:1999-06-01 00:00:00

  • The effective and collective dose to patients undergoing abdominopelvic and trunk computed tomography examinations: A Belgian multicentre study.

    abstract:OBJECTIVES:This study aims to evaluate the radiation exposure to patients undergoing an abdominopelvic or a chest and abdominopelvic (trunk) CT examination and to assess compliance to imaging referral guidelines. METHODS:To this end, 357 standard abdominopelvic and trunk CT scans were collected from 8 Belgian institut...

    journal_title:European journal of radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1016/j.ejrad.2018.12.019

    authors: De Roo B,Stichelbaut N,Hoste P,Verstraete K,Bacher K

    更新日期:2019-02-01 00:00:00

  • Assessment of cardiac implantable electric device lead perforation using a metal artifact reduction algorithm in cardiac computed tomography.

    abstract:PURPOSE:CT is considered the non-invasive gold standard for evaluating cardiac implantable electronic devices (CIEDs) lead perforation, but metal artifacts caused by the lead tip affect the image quality and make a definitive diagnosis challenging. We compared the performances of the metal artifact reduction (MAR) algo...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2021.109530

    authors: Kidoh M,Oda S,Nakato K,Sakabe D,Kanazawa H,Takashio S,Nakaura T,Nagayama Y,Sasao A,Hatemura M,Funama Y,Kaikita K,Tsujita K,Ikeda O,Azuma M,Hirai T

    更新日期:2021-01-09 00:00:00

  • Can high-risk CT features suggest local recurrence after stereotactic body radiation therapy for lung cancer? A systematic review and meta-analysis.

    abstract:PURPOSE:To perform a systematic review and meta-analysis evaluating usefulness of high-risk CT features (HRFs) on follow-up CT in detecting local recurrence after stereotactic body radiation therapy (SBRT) in lung cancer patients. METHODS:Pubmed and EMBASE were searched up to January 11th, 2019. We included studies th...

    journal_title:European journal of radiology

    pub_type: 杂志文章,meta分析

    doi:10.1016/j.ejrad.2020.108978

    authors: Kim TH,Woo S,Halpenny DF,Kim YJ,Yoon SH,Suh CH

    更新日期:2020-06-01 00:00:00

  • Iodine quantification to distinguish hepatic neuroendocrine tumor metastasis from hepatocellular carcinoma at dual-source dual-energy liver CT.

    abstract:PURPOSE:To investigate the value of third-generation dual-source dual-energy computed tomography (DECT) iodine quantification to distinguish hepatic neuroendocrine tumor (NET) metastasis from hepatocellular carcinoma (HCC) in non-cirrhotic liver parenchyma. MATERIAL AND METHODS:Forty-six patients (mean age, 64.9 ± 10....

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2018.05.019

    authors: Kaltenbach B,Wichmann JL,Pfeifer S,Albrecht MH,Booz C,Lenga L,Hammerstingl R,D'Angelo T,Vogl TJ,Martin SS

    更新日期:2018-08-01 00:00:00

  • Clinical significance of sonography of the ureter.

    abstract::The relevance of sonography compared with conventional methods is demonstrated by means of 103 patients investigated with obstruction of the ureter. The knowledge of the exact topographic anatomy of the ureter in all sections enables the experienced investigator to demonstrate cause and position of ureteral obstructio...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:

    authors: Egender G,Furtschegger A

    更新日期:1987-02-01 00:00:00

  • Apoplexy of a pituitary macroadenoma with reversible third, fourth and sixth cranial nerve palsies following administration of hypothalamic releasing hormones: MR features.

    abstract::Pituitary apoplexy in patients with pituitary macroadenomas can occur either spontaneously or following various interventions. We present a case of a 71-year-old woman who developed third, fourth, and sixth cranial nerve palsies following administration of the four hypothalamic releasing hormones for routine preoperat...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/s0720-048x(00)00148-0

    authors: Riedl M,Clodi M,Kotzmann H,Hainfellner JA,Schima W,Reitner A,Czech T,Luger A

    更新日期:2000-10-01 00:00:00

  • In vivo 1H MR spectroscopy of thyroid carcinoma.

    abstract::To determine if proton magnetic resonance spectroscopy (1H MRS) of thyroid carcinoma is feasible and to determine if 1H MRS spectra of malignant tumors differ from that of normal thyroid tissue. We performed 1H MRS at 1.5 T at echo-times (TE) 136 and 272 ms to examine eight patients with thyroid cancer (primary tumour...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2004.05.003

    authors: King AD,Yeung DK,Ahuja AT,Tse GM,Chan AB,Lam SS,van Hasselt AC

    更新日期:2005-04-01 00:00:00

  • Comparison of grey matter atrophy between patients with neuromyelitis optica and multiple sclerosis: a voxel-based morphometry study.

    abstract:PURPOSE:Previous studies have established regional grey matter (GM) loss in multiple sclerosis (MS). However, whether there is any regional GM atrophy in neuromyelitis optica (NMO) and the difference between NMO and MS is unclear. The present study addresses this issue by voxel-based morphometry (VBM). METHODS:Convent...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2011.01.065

    authors: Duan Y,Liu Y,Liang P,Jia X,Yu C,Qin W,Sun H,Liao Z,Ye J,Li K

    更新日期:2012-02-01 00:00:00

  • Reject analysis: a pilot programme for image quality management.

    abstract::The radiographic film wastage and the different parameters affecting this wastage were analysed for a 9-week period at a 600-bed University Hospital. An overall reject rate of 7.6% was found. The different reasons for rejection were evaluated, while retake rate, relation between working experience of the personnel, am...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/0720-048x(91)90067-6

    authors: Arvanitis TN,Parizel PM,Degryse HR,De Schepper AM

    更新日期:1991-05-01 00:00:00

  • Prediction of molecular subtypes of breast cancer using BI-RADS features based on a "white box" machine learning approach in a multi-modal imaging setting.

    abstract:PURPOSE:To develop and validate an interpretable and repeatable machine learning model approach to predict molecular subtypes of breast cancer from clinical metainformation together with mammography and MRI images. METHODS:We retrospectively assessed 363 breast cancer cases (Luminal A 151, Luminal B 96, HER2 76, and B...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2019.03.015

    authors: Wu M,Zhong X,Peng Q,Xu M,Huang S,Yuan J,Ma J,Tan T

    更新日期:2019-05-01 00:00:00

  • Percutaneous needle biopsy in diagnosis and identification of causative organisms in cases of suspected vertebral osteomyelitis.

    abstract:BACKGROUND:Biopsy with demonstration of the infectious organism is the gold standard for diagnosing spondylodiscitis. The purpose of this study is to evaluate the positive culture rate of image-guided percutaneous biopsy in cases of radiologically suspected and unsuspected spinal osteomyelitis and to assess the role of...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2011.01.125

    authors: Sehn JK,Gilula LA

    更新日期:2012-05-01 00:00:00

  • Coronary calcium scoring with MDCT: the radiation dose to the breast and the effectiveness of bismuth breast shield.

    abstract:OBJECTIVE:The purpose of our study was to determine the breast radiation dose during coronary calcium scoring with multidetector computerized tomography (MDCT). We also evaluated the degree of dose reduction by using a bismuth breast shield when performing coronary calcium scoring with MDCT. MATERIALS AND METHODS:The ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2006.08.012

    authors: Yilmaz MH,Yaşar D,Albayram S,Adaletli I,Ozer H,Ozbayrak M,Mihmanli I,Akman C

    更新日期:2007-01-01 00:00:00

  • Low residual diet and hydration improving double contrast examination of the colon.

    abstract::Light food diet and low residual diet with hydration, both combined with Proctosal and Bisacodyl cleansing, were compared in 268 patients in the preparation of the colon for double contrast examination. Low residual diet with hydration resulted in significantly less residual fecal material, no flocculation of the bari...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:

    authors: Virkki R,Mäkelä P

    更新日期:1983-08-01 00:00:00

  • Potential of ultrasound in the pediatric chest.

    abstract::Ultrasound (US) of chest, even with inherent limitations of the US beam and air, has been useful in many pediatric chest conditions. It has extended its role and is now widely used by many subspecialists in medicine. This review article will cover techniques, indications, and applications of chest US in neonates, infa...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2014.04.011

    authors: Trinavarat P,Riccabona M

    更新日期:2014-09-01 00:00:00

  • S-MRI score: A simple method for assessing bone marrow involvement in Gaucher disease.

    abstract::Semi quantitative MRI is a very useful procedure for evaluating the bone marrow burden (BMB) in Gaucher disease (GD). Score systems have been applied to obtain a parameter for evaluating the severity of bone disease. Our purpose was to test a simple, reproducible and accurate score to evaluate bone marrow involvement ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2006.11.024

    authors: Roca M,Mota J,Alfonso P,Pocoví M,Giraldo P

    更新日期:2007-04-01 00:00:00

  • Reducing CT radiation exposure with organ effective modulation: A retrospective clinical study.

    abstract:OBJECTIVE:To evaluate the effect of Organ Effective Modulation (OEM) on objective and subjective image quality as well as the radiation dose needed for thoracoabdominal computed tomography (CT). METHOD:This retrospective study included 196 consecutive patients who were referred to our institution for enhanced thoracoa...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2016.06.008

    authors: Akai H,Kiryu S,Shibata E,Maeda E,Sato J,Tomizawa N,Nojima M,Ohtomo K

    更新日期:2016-09-01 00:00:00

  • Intra-articular distribution pattern after ultrasound-guided injections in wrist joints of patients with rheumatoid arthritis.

    abstract:OBJECTIVE:To investigate the distribution of an ultrasound-guided intra-articular (IA) injection in the wrist joint of patients with rheumatoid arthritis (RA). METHODS:An ultrasound-guided IA drug injection into the wrist joint was performed in 17 patients with 1 ml methylprednisolone (40 mg/ml), 0.5 ml Lidocaine (5mg...

    journal_title:European journal of radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.ejrad.2007.08.037

    authors: Boesen M,Jensen KE,Torp-Pedersen S,Cimmino MA,Danneskiold-Samsøe B,Bliddal H

    更新日期:2009-02-01 00:00:00

  • T1 mapping of the ischemic myocardium: Review of potential clinical use.

    abstract::Cardiac magnetic resonance imaging (CMR) is an indispensable part of the diagnostic algorithm in cardiology. CMR has become a gold standard in various disorders; moreover, it is well established also as a surrogate end-point in experimental and clinical studies. Particularly, the ability to directly display myocardial...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2016.04.010

    authors: Baxa J,Ferda J,Hromádka M

    更新日期:2016-10-01 00:00:00

  • Nasopharyngeal carcinoma.

    abstract::Imaging plays an important role in the staging of nasopharyngeal carcinoma. Accurate staging is necessary, as the treatment is directly dependent on stage. Clinical examination provides information on mucosal involvement but is unable to determine the deep extension or the presence of skull base invasion or intracrani...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2008.03.029

    authors: Chong VF,Ong CK

    更新日期:2008-06-01 00:00:00

  • CT-guided aspiration in potentially infected total hip replacements complicated by heterotopic bone.

    abstract::Aspiration of the hip joint in the setting of a potentially infected total hip replacement is occasionally unsuccessful under fluoroscopic guidance because of periarticular heterotopic bone. Of 136 consecutive patients with total hip replacements who were referred to the radiology department for hip aspiration because...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/0720-048x(95)00606-q

    authors: Chew FS,Brown JH,Palmer WE,Kattapuram SV

    更新日期:1995-05-01 00:00:00

  • Venous thromboembolism: additional diagnostic value and radiation dose of pelvic CT venography in patients with suspected pulmonary embolism.

    abstract:PURPOSE:To assess the additional diagnostic value of indirect CT venography (CTV) of the pelvis and upper thighs performed after pulmonary CT angiography (CTA) for the diagnosis of venous thromboembolism (VTE). MATERIALS AND METHODS:In a retrospective analysis, the radiology information system entries between January ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2010.12.101

    authors: Reichert M,Henzler T,Krissak R,Apfaltrer P,Huck K,Buesing K,Sueselbeck T,Schoenberg SO,Fink C

    更新日期:2011-10-01 00:00:00

  • Positioning of the wrist for scaphoid radiography.

    abstract:PURPOSE:The purpose of this cadaver study was to determine the ideal position of the wrist for scaphoid radiography. MATERIALS AND METHODS:Four cadaver wrists were rotated around their longitudinal axis in 15 degrees increments and exposures were taken. Seven postero-anterior images were taken as well. Thus, 18 images...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2007.02.008

    authors: Toth F,Sebestyen A,Balint L,Mester S,Szabo G,Nyarady J,Weninger C,Angyal M,Lovasz G

    更新日期:2007-10-01 00:00:00

  • CT and MR imaging for solid renal mass characterization.

    abstract::As our understanding has expanded that relatively large fraction of incidentally discovered renal masses, especially in small size, are benign or indolent even if malignant, there is growing acceptance of more conservative management including active surveillance for small renal masses. As for advanced renal cell carc...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2017.12.008

    authors: Sasaguri K,Takahashi N

    更新日期:2018-02-01 00:00:00

  • Renal and pulmonary lymphangioleiomyomatosis: a case report.

    abstract::Lymphangioleiomyomatosis (LAM) is a rare disease that most commonly involves the lung. However, extrapulmonary lymphangioleiomyomatosis rarely occurs with or without subsequent involvement of the lung. We report a case of incidentally found renal and pulmonary lymphangioleiomyomatosis in a patient who had no stigmata ...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/s0720-048x(00)00161-3

    authors: Kim KW,Seo JB,Lee HJ,Im JG,Kim SH

    更新日期:2000-12-01 00:00:00

  • Diagnostic value of tendon thickness and structure in the sonographic diagnosis of supraspinatus tendinopathy: room for a two-step approach.

    abstract:OBJECTIVE:The aim of our study was to systematically compare different methodologies to establish an evidence-based approach based on tendon thickness and structure for sonographic diagnosis of supraspinatus tendinopathy when compared to MRI. METHODS:US was obtained from 164 symptomatic patients with supraspinatus ten...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2014.02.021

    authors: Arend CF,Arend AA,da Silva TR

    更新日期:2014-06-01 00:00:00

  • Breast compression and experienced pain during mammography by use of three different compression paddles.

    abstract:OBJECTIVES:We aimed to compare pain experienced during screening mammography, using three different compression paddles: a fixed paddle standardizing pressure (study paddle), a flexible, and a fixed paddle. MATERIAL AND METHODS:Using a numeric rating scale (NRS), ranged 0-10, we collected information on pain experienc...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2019.04.006

    authors: Moshina N,Sebuødegård S,Evensen KT,Hantho C,Iden KA,Hofvind S

    更新日期:2019-06-01 00:00:00