Iodine contrast-to-noise ratio improvement at unit dose and contrast media volume reduction in whole-body photon-counting CT.

Abstract:

PURPOSE:To assess the dose-normalized iodine contrast-to-noise-ratio (CNRD) improvement and contrast media reduction potential obtained with photon-counting (PC) CT compared to conventional energy-integrating (EI) CT as a function of patient size and tube voltage. METHOD:Images of a semi-anthropomorphic phantom of different sizes (small, medium, large) equipped with vials containing different iodine concentrations were acquired at the SOMATOM CounT prototype CT system using tube voltages of 80 kV-140 kV. CNRD is evaluated in reconstructions obtained using the EI detector, the PC detector using a single bin, and in reconstructions obtained by statistically optimally weighting acquisitions with two bins. Iodine CNRD improvements, potential dose reduction and the potential contrast media volume reduction are reported. RESULTS:In general, iodine CNRD improvement increases with increasing tube voltage for all patient sizes. In particular, if only one energy bin is used, the CNRD improvement is up to 30 % (small: 10 %, medium: 18 %, large: 30 %) and up to 37 % if an optimal weighting of two bins is performed (small: 13 %, medium: 25 %, large: 37 %) which is equivalent to the potential contrast media volume reduction. The improved iodine CNRD of PC compared to EI may allow for a potential radiation dose reduction of up to 46 %. CONCLUSIONS:All patients' iodine contrast at given x-ray dose, and particularly medium and large sized patients acquired at higher tube voltages, may benefit from photon-counting CT. The iodine contrast improvement can be used to reduce patient dose or to reduce the amount of contrast agent that is administered.

journal_name

Eur J Radiol

authors

Sawall S,Klein L,Amato C,Wehrse E,Dorn S,Maier J,Heinze S,Schlemmer HP,Ziener CH,Uhrig M,Kachelrieß M

doi

10.1016/j.ejrad.2020.108909

subject

Has Abstract

pub_date

2020-05-01 00:00:00

pages

108909

eissn

0720-048X

issn

1872-7727

pii

S0720-048X(20)30098-X

journal_volume

126

pub_type

杂志文章
  • Computed tomographic myelography characteristics of spinal cord atrophy in juvenile muscular atrophy of the upper extremity.

    abstract::Although atrophy of the lower cervical and upper thoracic cord in juvenile muscular atrophy of distal upper extremity has been reported, the atrophic patterns of the cord, especially in the transverse section, have not been studied extensively. The aim of this study is to clarify the atrophic patterns of the cord by C...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/0720-048x(91)90033-r

    authors: Hirabuki N,Mitomo M,Miura T,Hashimoto T,Kawai R,Kozuka T

    更新日期:1991-11-01 00:00:00

  • Degeneration and height of cervical discs classified from MRI compared with precise height measurements from radiographs.

    abstract:STUDY DESIGN:Descriptive study comparing MRI classifications with measurements from radiographs. OBJECTIVES:1. Define the relationship between MRI classified cervical disc degeneration and objectively measured disc height. 2. Assess the level of inter- and intra-observer errors using MRI in defining cervical disc dege...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2005.02.005

    authors: Kolstad F,Myhr G,Kvistad KA,Nygaard OP,Leivseth G

    更新日期:2005-09-01 00:00:00

  • Fast magnetic resonance imaging of the lung.

    abstract::The impact of fast MR techniques developed for MR imaging of the lung will soon be recognized as equivalent to the high-resolution technique in chest CT imaging. In this article, the difficulties in MR imaging posed by lung morphology and its physiological motion are briefly introduced. Then, fast MR imaging technique...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/s0720-048x(98)00174-0

    authors: Hatabu H,Chen Q,Stock KW,Gefter WB,Itoh H

    更新日期:1999-02-01 00:00:00

  • Shear wave elastography of thyroid nodules for the prediction of malignancy in a large scale study.

    abstract:OBJECTIVES:The purpose of this study is to validate the usefulness of shear wave elastography (SWE) in predicting thyroid malignancy with a large-scale quantitative SWE data. METHODS:This restrospective study included 476 thyroid nodules in 453 patients who underwent gray-scale US and SWE before US-guided fine-needle ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2014.11.019

    authors: Park AY,Son EJ,Han K,Youk JH,Kim JA,Park CS

    更新日期:2015-03-01 00:00:00

  • Magnetic resonance imaging of breast vascularity in medial versus lateral breast cancer.

    abstract:OBJECTIVE:Breasts with malignant tumors can demonstrate a general increased vascularity compared to the contralateral breast and a prominent blood vessel adjacent to the tumor on magnetic resonance imaging (MRI). The aim of the study was to further characterize these alterations in blood supply by location of the tumor...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2009.10.020

    authors: Grubstein A,Yepes M,Kiszonas R

    更新日期:2010-08-01 00:00:00

  • Ultrasonography of the pancreatic tail through spleen and through fluid-filled stomach.

    abstract::In the present study ultrasonography observed the tail of the pancreas more frequently through the spleen than by any other approach. If the splenic approach fails, examination through the fluid-filled stomach may be tried. ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:

    authors: Päivänsalo M,Suramo I

    更新日期:1986-05-01 00:00:00

  • Improving the prediction of lung adenocarcinoma invasive component on CT: Value of a vessel removal algorithm during software segmentation of subsolid nodules.

    abstract:PURPOSE:To evaluate the value of a vessel removal algorithm in segmentation of subsolid nodules by comparing the software solid component measurement on CT, before and after vessel removal, with the measurement of the invasive component on pathology in lung adenocarcinomas manifesting as subsolid nodules. MATERIALS AN...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2018.01.016

    authors: Garzelli L,Goo JM,Ahn SY,Chae KJ,Park CM,Jung J,Hong H

    更新日期:2018-03-01 00:00:00

  • Deep learning-based classification of lower extremity arterial stenosis in computed tomography angiography.

    abstract:PURPOSE:The purpose of this study is to develop and evaluate a deep learning model to assist radiologists in classifying lower extremity arteries based on the degree of arterial stenosis caused by plaque in lower extremity computed tomography angiography (CTA) of patients with peripheral artery disease. METHODS:In thi...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2021.109528

    authors: Dai L,Zhou Q,Zhou H,Zhang H,Cheng P,Ding M,Xu X,Zhang X

    更新日期:2021-01-08 00:00:00

  • Factors affecting the rate of false positive marks in CAD in full-field digital mammography.

    abstract:OBJECTIVE:To assess the effect of breast density, fibroglandular tissue volume, and breast volume on the rate of false-positive marks of a computer-assisted detection software in digital mammography. MATERIALS AND METHODS:222 patients with normal digital mammograms and a minimum follow-up of 22 months were retrospecti...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2012.02.017

    authors: Engelken F,Bremme R,Bick U,Hammann-Kloss S,Fallenberg EM

    更新日期:2012-08-01 00:00:00

  • Assessment and quantification of sources of variability in breast apparent diffusion coefficient (ADC) measurements at diffusion weighted imaging.

    abstract:PURPOSE:Apparent Diffusion Coefficient (ADC) measurements are increasingly used for assessing breast cancer response to neoadjuvant chemotherapy although little data exists on ADC measurement reproducibility. The purpose of this work was to investigate and characterise the magnitude of errors in ADC measures that may b...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2015.05.032

    authors: Giannotti E,Waugh S,Priba L,Davis Z,Crowe E,Vinnicombe S

    更新日期:2015-09-01 00:00:00

  • Assessment of the gain transfer function of phosphors for application in medical imaging radiation detectors.

    abstract:OBJECTIVE:to study various phosphors used in detectors of medical imaging systems by the gain transfer function (GTF), defined in terms of X-ray luminescence efficiency, light spectrum and modulation transfer function. MATERIALS AND METHODS:four phosphor materials, La(2)O(2)S:Tb, Y(2)O(2)S:Tb, Y(2)O(2)S:Eu and Y(2)O(3...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/s0720-048x(99)00106-0

    authors: Cavouras D,Kandarakis I,Maris T,Panayiotakis GS,Nomicos CD

    更新日期:2000-07-01 00:00:00

  • Imaging measurement and analysis of normal tilt angle of atrium septum.

    abstract:AIM:The atrium septum is tilted in heart. There is an angle between atrium septum and the cross section of body, which is called tilt angles of atrium septum (TAAS) in this study, however this angle has not been specifically mentioned in literatures. In this article TAAS was measured and analysed on axial images of con...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2011.01.040

    authors: Wang J,Zhang Z,Yu W,Miao C

    更新日期:2012-01-01 00:00:00

  • Detection of significant coronary artery stenosis with 64-section MDCT angiography.

    abstract:PURPOSE:To prospectively evaluate the diagnostic performance of 64-section multidetector computed tomography (MDCT) to detect significant coronary artery stenosis using conventional coronary angiography (CCA) as the reference standard. MATERIALS AND METHODS:Institutional Review Board approval and informed consent were...

    journal_title:European journal of radiology

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.ejrad.2007.01.009

    authors: Oncel D,Oncel G,Tastan A,Tamci B

    更新日期:2007-06-01 00:00:00

  • Modified RECIST to assess tumor response after transarterial chemoembolization of hepatocellular carcinoma: CT-pathologic correlation in 178 liver explants.

    abstract:PURPOSE:To retrospectively evaluate agreement between modified RECIST (mRECIST) assessed at Computed Tomography (CT) and pathology in a large series of patients with hepatocellular carcinoma (HCC) who were transplanted after transarterial chemoembolization (TACE). MATERIALS AND METHODS:IRB approval was obtained. The s...

    journal_title:European journal of radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.ejrad.2012.12.009

    authors: Bargellini I,Bozzi E,Campani D,Carrai P,De Simone P,Pollina L,Cioni R,Filipponi F,Bartolozzi C

    更新日期:2013-05-01 00:00:00

  • Contrast-enhanced sonography in pancreatic diseases.

    abstract::Contrast-enhanced sonography is a widely available imaging modality for the diagnosis of pancreatic diseases. With this procedure, pancreatic tumours can be differentiated better. Furthermore, contrast-enhanced sonography produces good results in the staging of acute pancreatitis severity, especially in the detection ...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2007.06.035

    authors: Rickes S,Rauh P,Uhle C,Ensberg D,Mönkemüller K,Malfertheiner P

    更新日期:2007-11-01 00:00:00

  • The efficacy of helical CT in the diagnosis of small bowel obstruction.

    abstract:OBJECTIVE:To evaluate the usefulness and reliability of helical computed tomography (CT) for patients with small bowel obstruction. METHODS AND MATERIAL:Helical CT findings of 41 patients were evaluated prospectively on the basis of the presence and the cause of obstruction, and the presence of strangulation. RESULTS...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/s0720-048x(02)00382-0

    authors: Obuz F,Terzi C,Sökmen S,Yilmaz E,Yildiz D,Füzün M

    更新日期:2003-12-01 00:00:00

  • PET-CT offers accurate assessment of tumour length in oesophageal malignancy.

    abstract:INTRODUCTION:Radiotherapy is increasingly used for both curative and palliative treatment of oesophageal malignancy. Accurate treatment depends on determining tumour location and length. This study assessed the value of PET-CT versus other staging modalities in determining tumour length. MATERIALS AND METHODS:Oesophag...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2014.10.014

    authors: Rollins KE,Lucas E,Tewari N,James E,Hughes S,Catton JA

    更新日期:2015-02-01 00:00:00

  • Reduced perfusion in white matter lesions in multiple sclerosis.

    abstract:OBJECTIVE:To investigate dynamic susceptibility contrast (DSC) perfusion weighted imaging (PWI) in white matter lesions (WML) in patients with multiple sclerosis (MS), using automatically generated binary masks of brain tissue. BACKGROUND:WML in MS have in some studies demonstrated perfusion abnormalities compared to ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2015.09.007

    authors: Sowa P,Bjørnerud A,Nygaard GO,Damangir S,Spulber G,Celius EG,Due-Tønnessen P,Harbo HF,Beyer MK

    更新日期:2015-12-01 00:00:00

  • Tissue-specific MR contrast agents.

    abstract::The purpose of this review is to outline recent trends in contrast agent development for magnetic resonance imaging. Up to now, small molecular weight gadolinium chelates are the workhorse in contrast enhanced MRI. These first generation MR contrast agents distribute into the intravascular and interstitial space, thus...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/s0720-048x(02)00332-7

    authors: Weinmann HJ,Ebert W,Misselwitz B,Schmitt-Willich H

    更新日期:2003-04-01 00:00:00

  • MRI evaluation of patellar tendon defect after harvesting its central third.

    abstract:PURPOSE:the purpose of this study was to evaluate defect width of patellar tendon after harvest for anterior cruciate ligament reconstruction. MATERIALS AND METHODS:we performed MRI at various time interval after graft harvest (2-96 months) on 28 patients who had had reconstruction of the anterior cruciate ligament us...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2003.08.006

    authors: Koseoglu K,Memis A,Argin M,Arkun R

    更新日期:2004-06-01 00:00:00

  • Focal liver lesion detection and characterization: comparison of non-contrast enhanced and SPIO-enhanced diffusion-weighted single-shot spin echo echo planar and turbo spin echo T2-weighted imaging.

    abstract:PURPOSE:To compare lesion conspicuity and image quality between single-shot spin echo echo planar imaging (SS SE-EPI) before, immediately and 5min after intravenous (IV) injection of superparamagnetic iron oxide (SPIO) for detecting and characterizing focal liver lesions (FLLs). MATERIALS AND METHODS:Twenty-five patie...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2008.09.005

    authors: Coenegrachts K,Matos C,ter Beek L,Metens T,Haspeslagh M,Bipat S,Stoker J,Rigauts H

    更新日期:2009-12-01 00:00:00

  • Higher precontrast CT density of the carotid plaque in the symptomatic patients.

    abstract:PURPOSE:The purpose of this study was to determine if there is a significant difference in the CT Hounsfield Unit (CTHU) of the carotid atherosclerotic plaque (CAP) on CTpre and CTartery depending on the presence of symptomatology. METHODS:Quantitative analysis of the CTHUs for the CAP was performed in 43 arteries (11...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2011.06.029

    authors: Park JK,Sung YH,Jeong SY,Lee JH

    更新日期:2012-09-01 00:00:00

  • Evaluation of hypervascular hepatocellular carcinoma in cirrhotic liver: comparison of different concentrations of contrast material with multi-detector row helical CT--a prospective randomized study.

    abstract:PURPOSE:To evaluate two different iodine concentrations of contrast material for detecting hypervascular hepatocellular carcinomas (HCCs) in cirrhotic liver by multi-detector row helical CT (MDCT) when a fixed contrast material volume and injection rate is used. MATERIALS AND METHODS:Institutional Review Board approva...

    journal_title:European journal of radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.ejrad.2010.10.006

    authors: Sofue K,Tsurusaki M,Kawasaki R,Fujii M,Sugimura K

    更新日期:2011-12-01 00:00:00

  • Quantitative 3D pulmonary MR-perfusion in patients with pulmonary arterial hypertension: correlation with invasive pressure measurements.

    abstract:PURPOSE:Pathological changes of the peripheral pulmonary arteries induce pulmonary arterial hypertension (PAH). Aim of this study was to quantitatively assess the effect of PAH on pulmonary perfusion by 3D-MR-perfusion techniques and to compare findings to healthy controls. Furthermore, quantitative perfusion data were...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2006.08.028

    authors: Ley S,Mereles D,Risse F,Grünig E,Ley-Zaporozhan J,Tecer Z,Puderbach M,Fink C,Kauczor HU

    更新日期:2007-02-01 00:00:00

  • Imaging of bone tumors for the musculoskeletal oncologic surgeon.

    abstract::The appropriate diagnosis and treatment of bone tumors requires close collaboration between different medical specialists. Imaging plays a key role throughout the process. Radiographic detection of a bone tumor is usually not challenging. Accurate diagnosis is often possible from physical examination, history, and sta...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2011.11.034

    authors: Errani C,Kreshak J,Ruggieri P,Alberghini M,Picci P,Vanel D

    更新日期:2013-12-01 00:00:00

  • Using low tube voltage (80kVp) quadruple phase liver CT for the detection of hepatocellular carcinoma: two-year experience and comparison with Gd-EOB-DTPA enhanced liver MRI.

    abstract:PURPOSE:To validate the diagnostic performance of quadruple phase low tube voltage liver CT through the comparison with Gd-EOB-DTPA enhanced liver MRI for the detection of HCC. MATERIALS AND METHODS:Non-obese patients (38 men, eight women) with 68 HCCs underwent quadruple-phase CT at 16 MDCT (using low tube voltage, 8...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2011.12.033

    authors: Lee CH,Kim KA,Lee J,Park YS,Choi JW,Park CM

    更新日期:2012-04-01 00:00:00

  • CT characteristics of resolving ground-glass opacities in a lung cancer screening programme.

    abstract:PURPOSE:This study aimed at evaluating the computed tomography (CT) characteristics of resolving localized ground-glass opacities (GGOs) in a screening programme for lung cancer. MATERIAL AND METHODS:280 patients at high-risk for lung cancer (221 men, 59 women; mean age, 58.6 years), divided into four groups (lung can...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2009.09.008

    authors: Felix L,Serra-Tosio G,Lantuejoul S,Timsit JF,Moro-Sibilot D,Brambilla C,Ferretti GR

    更新日期:2011-03-01 00:00:00

  • Artificial intelligence assistance improves reporting efficiency of thoracic aortic aneurysm CT follow-up.

    abstract:OBJECTIVE:Follow-up of aortic aneurysms by computed tomography (CT) is crucial to balance the risks of treatment and rupture. Artificial intelligence (AI)-assisted radiology reporting promises time savings and reduced inter-reader variabilities. METHODS:The influence of AI assistance on the efficiency and accuracy of ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2020.109424

    authors: Rueckel J,Reidler P,Fink N,Sperl J,Geyer T,Fabritius MP,Ricke J,Ingrisch M,Sabel BO

    更新日期:2021-01-01 00:00:00

  • Whole-body CT with high heat-capacity X-ray tube and automated tube current modulation--effect of tube current limitation on contrast enhancement, image quality and radiation dose.

    abstract:PURPOSE:To evaluate the effect of tube current limitation on contrast enhancement, image quality, and radiation dose in whole-body 64-detector CT with a high heat-capacity X-ray tube and automated tube current modulation. MATERIALS AND METHODS:One hundred eighteen patients were randomized into three whole-body CT prot...

    journal_title:European journal of radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.ejrad.2015.01.019

    authors: Kanematsu M,Kondo H,Miyoshi T,Goshima S,Noda Y,Tanahashi Y,Bae KT

    更新日期:2015-05-01 00:00:00

  • Bone metastasis in patients with non-small cell lung cancer: the diagnostic role of F-18 FDG PET/CT.

    abstract:PURPOSE:To evaluate the performance of F-18 FDG PET/CT in the detection of bone metastasis in non-small cell lung cancer (NSCLC) patients. MATERIALS AND METHODS:Three hundred and sixty-two consecutive NSCLC patients who underwent F-18 FDG PET/CT scanning were retrospectively analyzed. Each image of PET/CT, combined CT...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2009.01.036

    authors: Liu N,Ma L,Zhou W,Pang Q,Hu M,Shi F,Fu Z,Li M,Yang G,Yu J

    更新日期:2010-04-01 00:00:00