Artificial intelligence assistance improves reporting efficiency of thoracic aortic aneurysm CT follow-up.

Abstract:

OBJECTIVE:Follow-up of aortic aneurysms by computed tomography (CT) is crucial to balance the risks of treatment and rupture. Artificial intelligence (AI)-assisted radiology reporting promises time savings and reduced inter-reader variabilities. METHODS:The influence of AI assistance on the efficiency and accuracy of aortic aneurysm reporting according to the AHA / ESC guidelines was quantified based on 324 AI measurements and 1944 radiological measurements: 18 aortic aneurysm patients, each with two CT scans (arterial contrast phase, electrocardiogram-gated) with an interval of at least six months have been included. One board-certified radiologist and two residents (8/4/2 years of experience in vascular imaging) independently assessed aortic diameters at nine landmark positions. Aneurysm extensions were compared with original CT reports. After three weeks washout period, CTs were re-assessed, based on graphically illustrated AI measurements. RESULTS:Time-consuming guideline-compliant aortic measurements revealed additional affections of the root / arch for 80 % of aneurysms that had initially been reported to be limited to the ascending aorta. AI assistance reduced mean reporting time by 63 % from 13:01 to 04:46 min including manual corrections of AI measurements (performed for 33.6 % of all measurements with predominance at the sinuses of Vasalva). AI assistance reduced total diameter inter-reader variability by 42.5 % (0.42 / 1.16 mm with / without AI assistance, mean of all patients and landmark positions, significant reduction for 6 out of 9 measuring positions). Conventional and AI-assisted quantification aneurysm progress varied to small extent (mean of 0.75 mm over all patients / landmark positions) not significantly exceeding radiologist's inter-reader variabilities. CONCLUSIONS:Guideline-compliant aorta measurement is crucial to report detailed aneurysm extension which might affect the strategy of interventional repair. AI assistance promises improved reporting efficiency and has high potential to reduce radiologist's inter-reader variabilities that can hamper diagnostic follow-up accuracy. KEY POINT:The time-consuming guideline-compliant aorta aneurysm assessment is crucial to report aneurysm extension in detail; AI-assisted measurement reduces reporting time, improves extension evaluation and reduces inter-reader variability.

journal_name

Eur J Radiol

authors

Rueckel J,Reidler P,Fink N,Sperl J,Geyer T,Fabritius MP,Ricke J,Ingrisch M,Sabel BO

doi

10.1016/j.ejrad.2020.109424

subject

Has Abstract

pub_date

2021-01-01 00:00:00

pages

109424

eissn

0720-048X

issn

1872-7727

pii

S0720-048X(20)30614-8

journal_volume

134

pub_type

杂志文章
  • The relevance of free fluid between intestinal loops detected by sonography in the clinical assessment of small bowel obstruction in adults.

    abstract:INTRODUCTION:The main role of the radiologist in the management of patients with suspicion of small bowel obstruction is to help triage patients into those that need immediate surgical intervention from those that require medical therapy or delayed surgery. Ultrasound examination is usually considered not helpful in bo...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2003.11.009

    authors: Grassi R,Romano S,D'Amario F,Giorgio Rossi A,Romano L,Pinto F,Di Mizio R

    更新日期:2004-04-01 00:00:00

  • Digital chest radiography--comparing two types of CRT monitors in a ROC experiment with a chest phantom.

    abstract::Two principally different 1000-line CRT (cathode ray tube) monitors connected to a digital image intensifier system for chest radiography were compared in terms of image quality and viewing comfort. Image quality was assessed by means of ROC analysis. Five observers tried to find simulated pathology positioned over th...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/0720-048x(96)00750-4

    authors: Kheddache S,Angelhed JE,Månsson LG,Denbratt L,Gottfridsson B,Olmarker A

    更新日期:1996-06-01 00:00:00

  • Crohn's disease: clinical-surgical questions and imaging answers.

    abstract::Crohn's disease is an inflammatory bowel disease (IBD) characterized by a relapsing clinical pattern that typically affects people during their adult and economically productive lives. Affected patients require clinical follow-up because of the periodic flare-up of the disease and of the risk of long-term complication...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2008.11.010

    authors: Válek V,Hustý J

    更新日期:2009-03-01 00:00:00

  • Digital fluoroscopic radiology: evaluation of the clinical impact.

    abstract::The use of digital image intensifier radiography (DIIR) for examinations in projection radiography is becoming more common. Fluoroscopic controlled contrast studies (barium- or iodine-based), particularly of the gastrointestinal tract, can be performed quickly and easily with a considerable decrease in radiation expos...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/0720-048x(93)90021-e

    authors: Lehmann KJ,Busch HP,Georgi M

    更新日期:1993-06-01 00:00:00

  • Imaging after vascular gene therapy.

    abstract::Targets for cardiovascular gene therapy currently include limiting restenosis after balloon angioplasty and stent placement, inhibiting vein bypass graft intimal hyperplasia/stenosis, therapeutic angiogenesis for cardiac and lower-limb ischemia, and prevention of thrombus formation. While catheter angiography is still...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2005.03.019

    authors: Manninen HI,Yang X

    更新日期:2005-11-01 00:00:00

  • Validation and absolute quantification of MR perfusion compared with CT perfusion in patients with unilateral cerebral arterial stenosis.

    abstract:OBJECTIVE:The aim of the study was to assess absolute quantification of dynamic susceptibility contrast-enhanced magnetic resonance perfusion (MRP) comparing with computed tomography perfusion (CTP) in patients with unilateral stenosis. MATERIALS AND METHODS:We retrospectively post-processed MRP in 20 patients with un...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2012.07.018

    authors: Chiu FY,Kao YH,Teng MM,Chung HW,Chang FC,Cho IC,Chen WC

    更新日期:2012-12-01 00:00:00

  • Liver fat quantification: Comparison of dual-echo and triple-echo chemical shift MRI to MR spectroscopy.

    abstract:PURPOSE:To assess the diagnostic value of MRI using dual-echo (2PD) and triple-echo (3PD) chemical shift imaging for liver fat quantification against multi-echo T2 corrected MR spectroscopy (MRS) used as the reference standard, and examine the effect of T2(*) imaging on accuracy of MRI for fat quantification. MATERIAL...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2015.05.001

    authors: Satkunasingham J,Besa C,Bane O,Shah A,de Oliveira A,Gilson WD,Kannengiesser S,Taouli B

    更新日期:2015-08-01 00:00:00

  • Factors associated with one step surgery in case of non-palpable breast cancer.

    abstract:PURPOSE:To examine factors associated with one step surgery in case of non-palpable breast cancer. MATERIALS AND METHODS:Clinical data of 152 consecutively diagnosed patients with breast cancer were analyzed retrospectively. Preoperative diagnostic findings were divided in subgroups: mammographically visible mass/micr...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2007.02.033

    authors: Schaefer FK,Eden I,Schaefer PJ,Peter D,Jonat W,Heller M,Schreer I

    更新日期:2007-12-01 00:00:00

  • Radiographic imaging features of thoracic complications after pneumonectomy in oncologic patients.

    abstract:PURPOSE:The morbidity and mortality for pneumonectomy in patients has been reported to be as high as 24%. To determine if a subset of patients undergoing pneumonectomy for a malignancy would have similar complication rates and appearances, we performed a review of the radiographic findings of patients at our institutio...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2010.08.040

    authors: Pool KL,Munden RF,Vaporciyan A,O'Sullivan PJ

    更新日期:2012-01-01 00:00:00

  • Multi-parametric quantification of tricuspid regurgitation using cardiovascular magnetic resonance: A comparison to echocardiography.

    abstract:BACKGROUND:Velocity-encoding is used to quantify tricuspid regurgitation (TR) by cardiovascular magnetic resonance (CMR), but requires additional dedicated imaging. We hypothesized that size and signal intensity (SI) of the cross-sectional TR jet area in the right atrium in short-axis steady-state free-precession image...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2016.11.025

    authors: Medvedofsky D,León Jiménez J,Addetia K,Singh A,Lang RM,Mor-Avi V,Patel AR

    更新日期:2017-01-01 00:00:00

  • Outcomes of premedication for non-ionic radio-contrast media hypersensitivity reactions in Korea.

    abstract:BACKGROUND:Radio-contrast media (CM)-related adverse reactions are important clinical problems that may cause fatal anaphylaxis. Accordingly, it has been common practice to premedicate patients who have had previous reactions to CM with corticosteroids, antihistamines, and H2 blockers to prevent hypersensitive reaction...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2010.06.014

    authors: Kim SH,Lee SH,Lee SM,Kang HR,Park HW,Kim SS,Cho SH,Min KU,Kim YY,Chang YS

    更新日期:2011-11-01 00:00:00

  • Thin-section CT of the mediastinum in preoperative N-staging of non-small cell lung cancer: comparison with FDG PET.

    abstract:PURPOSE:To compare diagnostic capability of preoperative N-staging of lung cancer between thin-section CT of the mediastinum and FDG PET, and 5mm slice thickness CT. MATERIALS AND METHODS:The subjects were 34 patients with lung carcinoma who were examined by both CT and PET, and subsequently underwent surgery between ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2009.01.021

    authors: Nambu A,Kato S,Motosugi U,Araki T,Okuwaki H,Nishikawa K,Saito A,Matsumoto K,Ichikawa T

    更新日期:2010-03-01 00:00:00

  • Clinical validation of a pressure-standardized compression mammography system.

    abstract:OBJECTIVES:Validation of a pressure-standardized compression mammography (PSCM) system, which aims to reduce discomfort and pain by applying the same pressure to every breast, independent of breast size. METHODS:We retrospectively studied mammograms of 39 patients acquired with a conventional force-standardized compre...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2018.06.021

    authors: den Boer D,Dam-Vervloet LAJ,Boomsma MF,de Boer E,van Dalen JA,Poot L

    更新日期:2018-08-01 00:00:00

  • Contrast-enhanced sonography in pancreatic diseases.

    abstract::Contrast-enhanced sonography is a widely available imaging modality for the diagnosis of pancreatic diseases. With this procedure, pancreatic tumours can be differentiated better. Furthermore, contrast-enhanced sonography produces good results in the staging of acute pancreatitis severity, especially in the detection ...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2007.06.035

    authors: Rickes S,Rauh P,Uhle C,Ensberg D,Mönkemüller K,Malfertheiner P

    更新日期:2007-11-01 00:00:00

  • Mapping the brain in type II diabetes: Voxel-based morphometry using DARTEL.

    abstract:PURPOSE:To investigate the pattern of brain volume changes of the brain in patients with type II diabetes mellitus using voxel-based morphometry. MATERIAL AND METHODS:Institutional ethics approval and informed consent were obtained. VBM based on the high resolution three-dimensional T1-weighted fast spoiled gradient r...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2011.04.025

    authors: Chen Z,Li L,Sun J,Ma L

    更新日期:2012-08-01 00:00:00

  • A new method to reduce false positive results in breast MRI by evaluation of multiple spectral regions in proton MR-spectroscopy.

    abstract:OBJECTIVES:To investigate whether the evaluation of multiple spectral regions can increase the diagnostic performance of 1H-MRS of the breast and reduce false positive findings. METHODS:93 patients (mean age 56 years, range 23-79) undergoing breast MRI for routine clinical indications on a 1.5T scanner were eligible f...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2017.04.014

    authors: Clauser P,Marcon M,Dietzel M,Baltzer PAT

    更新日期:2017-07-01 00:00:00

  • Nondiffuse fatty infiltration of the liver: does the uptake of iron-oxide increase or decrease at SPIO-enhanced MR imaging?

    abstract:PURPOSE:To clarify whether the uptake of SPIO increases or decreases in areas of fatty change compared with surrounding areas of nonfatty change at SPIO-enhanced MR imaging. MATERIALS AND METHODS:Approval for this retrospective study was obtained from our institutional review board. This study included 14 patients wit...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2011.04.004

    authors: Onoda H,Ito K,Tanabe M,Shimizu A,Matsunaga N

    更新日期:2011-08-01 00:00:00

  • Multimodality imaging of pulmonary infarction.

    abstract::The impact of absent pulmonary arterial and venous flow on the pulmonary parenchyma depends on a host of factors. These include location of the occlusive insult, the speed at which the occlusion develops and the ability of the normal dual arterial supply to compensate through increased bronchial arterial flow. Pulmona...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2014.07.016

    authors: Bray TJP,Mortensen KH,Gopalan D

    更新日期:2014-12-01 00:00:00

  • Investigation of renal lesions by diffusion-weighted magnetic resonance imaging applying intravoxel incoherent motion-derived parameters--initial experience.

    abstract:PURPOSE:Usefulness of biexponentially fitted signal attenuation at different b-values for differentiating the histological characteristics of renal tumors. MATERIALS AND METHODS:A total of 26 patients with 28 renal masses (histologically proven: 20 clear cell renal cell carcinomas [ccRCC], three transitional cell carc...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2011.10.016

    authors: Rheinheimer S,Stieltjes B,Schneider F,Simon D,Pahernik S,Kauczor HU,Hallscheidt P

    更新日期:2012-03-01 00:00:00

  • Basilar artery atherosclerotic plaques distribution in symptomatic patients: a 3.0T high-resolution MRI study.

    abstract:PURPOSE:To investigate basilar artery atherosclerotic plaque distribution characteristics in symptomatic patients using 3.0T high-resolution MRI. MATERIALS AND METHODS:Thirty-eight patients with recent ischemic strokes or transient ischemic attacks were included. Conventional angiographic luminal imaging of these pati...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2012.10.031

    authors: Huang B,Yang WQ,Liu XT,Liu HJ,Li PJ,Lu HK

    更新日期:2013-04-01 00:00:00

  • T2 mapping and dGEMRIC after autologous chondrocyte implantation with a fibrin-based scaffold in the knee: preliminary results.

    abstract:OBJECTIVE:To assess repair tissue (RT) after the implantation of BioCartII, an autologous chondrocyte implantation (ACI) technique with a fibrin-hyaluronan polymer as scaffold. T2 mapping and delayed Gadolinium Enhanced Magnetic Resonance Imaging of Cartilage (dGEMRIC) were used to gain first data on the biochemical pr...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2008.12.006

    authors: Domayer SE,Welsch GH,Nehrer S,Chiari C,Dorotka R,Szomolanyi P,Mamisch TC,Yayon A,Trattnig S

    更新日期:2010-03-01 00:00:00

  • Breath-hold after forced expiration before removal of the biopsy needle decreased the rate of pneumothorax in CT-guided transthoracic lung biopsy.

    abstract:PURPOSE:To assess the effect of a breath-hold after forced expiration on the rate of pneumothorax after computed tomography (CT)-guided transthoracic needle biopsy of pulmonary lesions. MATERIALS AND METHODS:Between January 2008 and December 2011, percutaneous CT-guided lung biopsy was performed in 440 patients. Two h...

    journal_title:European journal of radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.ejrad.2012.09.013

    authors: Min L,Xu X,Song Y,Issahar BD,Wu J,Zhang L,Huang Q,Chen M

    更新日期:2013-01-01 00:00:00

  • Quantitative computed tomography measurements to evaluate airway disease in chronic obstructive pulmonary disease: Relationship to physiological measurements, clinical index and visual assessment of airway disease.

    abstract:PURPOSE:To correlate currently available quantitative CT measurements for airway disease with physiological indices and the body-mass index, airflow obstruction, dyspnea, and exercise capacity (BODE) index in patients with chronic obstructive pulmonary disease (COPD). MATERIALS AND METHODS:This study was approved by o...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2016.09.010

    authors: Nambu A,Zach J,Schroeder J,Jin G,Kim SS,Kim YI,Schnell C,Bowler R,Lynch DA

    更新日期:2016-11-01 00:00:00

  • Amyloidosis in the head and neck: CT findings with clinicopathological correlation.

    abstract:PURPOSE:To characterize the CT imaging features of head and neck amyloidosis and correlate with extent of disease and clinical outcomes. MATERIALS AND METHODS:This retrospective study included 80 patients with head and neck amyloidosis who underwent soft tissue neck CT imaging between November 2003 and April 2018. The...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2020.109034

    authors: Takumi K,Staziaki PV,Hito R,Nadgir RN,Berk JL,Andreu-Arasa VC,Chavez W,Sakai O

    更新日期:2020-07-01 00:00:00

  • From protein-protein interaction to therapy response: molecular imaging of heat shock proteins.

    abstract::HSP70 promoter-driven gene therapy and inhibition of HSP90 activity with small molecule inhibitors are two shining points in a newly developed cohort of cancer treatment. For HSP70 promoters, high efficiency and heat inducibility within a localized region make it very attractive to clinical translation. The HSP90 inhi...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2009.01.052

    authors: Niu G,Chen X

    更新日期:2009-05-01 00:00:00

  • Dual energy computed tomography evaluation of skeletal traumas.

    abstract::Skeletal traumas are among the most common routine challenges faced by Emergency Radiologists, in particular in case of radiographically occult nondisplaced fractures or in case of soft tissue injuries. With the development of Dual Energy Computed Tomography (DECT) technology, new post-processing applications have gai...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2020.109456

    authors: Simonetti I,Verde F,Palumbo L,Di Pietto F,Puglia M,Scaglione M,Ragozzino A,Romano S

    更新日期:2021-01-01 00:00:00

  • Pancreaticobiliary involvement in treated type 1 autoimmune pancreatitis: Imaging pattern and risk factors for disease relapse.

    abstract:PURPOSE:To evaluate the imaging pattern of pancreaticobiliary lesions in patients with treated type 1AIP, to determine the incidence of disease relapse and malignancy, and to identify the risk factors. METHOD:The institutional review board approval was acquired. All patients gave written informed consent. From a prosp...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2019.108673

    authors: Zhu L,Xue HD,Zhang W,Wang Q,Tan B,Lai YM,Zheng WY,Asbach P,Hamm B,Denecke T,Jin ZY

    更新日期:2019-11-01 00:00:00

  • Dynamic sequential computed tomography in abdominal tumours. Some aspects for differential diagnosis.

    abstract::Dynamic CT in combination with intravenous bolus injection of contrast material provides a study of the pharmacokinetics in great vessels as well as in tissues. If the enhancement in the region of interest is plotted against time, the time-enhancement diagrams obtained reflect the contrast material passage mathematica...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:

    authors: Metzger HO,Hübener KH

    更新日期:1985-02-01 00:00:00

  • The role of Thallium-201 scintigraphy and Tc-99m pentavalent dimercaptosuccinic acid in diagnosis and grading of chondrosarcoma.

    abstract:PURPOSE:Distinguishing between enchondromas and low-grade (grade 1) chondrosarcomas can be challenging. The aim of this study was to investigate the role of Thallium-201 scintigraphy and Technetium-99 m pentavalent dimercaptosuccinic acid (Tc-99 m DMSA (V)) in the diagnosis and grading of chondrosarcomas. METHODS:232 ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2020.108846

    authors: Jo O,Schlicht S,Slavin J,Di Bella C,Pang G,Powell G,Spelman T,Choong PF

    更新日期:2020-04-01 00:00:00

  • Quantitative assessment of cross-sectional area of small pulmonary vessels in patients with COPD using inspiratory and expiratory MDCT.

    abstract:OBJECTIVES:Structural and functional changes in pulmonary vessels are prevalent at the initial stages of chronic obstructive pulmonary disease (COPD). These vascular alterations can be assessed using cross-sectional area (CSA) of small pulmonary vessels. However, neither in non-COPD smokers nor in COPD patients it has ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2013.05.022

    authors: Matsuura Y,Kawata N,Yanagawa N,Sugiura T,Sakurai Y,Sato M,Iesato K,Terada J,Sakao S,Tada Y,Tanabe N,Suzuki Y,Tatsumi K

    更新日期:2013-10-01 00:00:00