Improving compliance in remote healthcare systems through smartphone battery optimization.

Abstract:

:Remote health monitoring (RHM) has emerged as a solution to help reduce the cost burden of unhealthy lifestyles and aging populations. Enhancing compliance to prescribed medical regimens is an essential challenge to many systems, even those using smartphone technology. In this paper, we provide a technique to improve smartphone battery consumption and examine the effects of smartphone battery lifetime on compliance, in an attempt to enhance users' adherence to remote monitoring systems. We deploy WANDA-CVD, an RHM system for patients at risk of cardiovascular disease (CVD), using a wearable smartphone for detection of physical activity. We tested the battery optimization technique in an in-lab pilot study and validated its effects on compliance in the Women's Heart Health Study. The battery optimization technique enhanced the battery lifetime by 192% on average, resulting in a 53% increase in compliance in the study. A system like WANDA-CVD can help increase smartphone battery lifetime for RHM systems monitoring physical activity.

authors

Alshurafa N,Eastwood JA,Nyamathi S,Liu JJ,Xu W,Ghasemzadeh H,Pourhomayoun M,Sarrafzadeh M

doi

10.1109/JBHI.2014.2329712

subject

Has Abstract

pub_date

2015-01-01 00:00:00

pages

57-63

issue

1

eissn

2168-2194

issn

2168-2208

journal_volume

19

pub_type

临床试验,杂志文章
  • A Resampling Based Grid Search Method to Improve Reliability and Robustness of Mixture-Item Response Theory Models of Multimorbid High-Risk Patients.

    abstract::There are many statistics available to the applied statistician for assessing model fit and even more methods for assessing internal and external validity. We detail a useful approach using a grid search technique that balances the internal model consistency with generalizability and can be used with models that natur...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2019.2948734

    authors: Batten AJ,Thorpe J,Piegari RI,Rosland AM

    更新日期:2020-06-01 00:00:00

  • A Residual Based Attention Model for EEG Based Sleep Staging.

    abstract::Sleep staging is to score the sleep state of a subject into different sleep stages such as Wake and Rapid Eye Movement (REM). It plays an indispensable role in the diagnosis and treatment of sleep disorders. As manual sleep staging through well-trained sleep experts is time consuming, tedious, and subjective, many aut...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2020.2978004

    authors: Qu W,Wang Z,Hong H,Chi Z,Feng DD,Grunstein R,Gordon C

    更新日期:2020-10-01 00:00:00

  • Automatic Screening of Sleep Apnea Patients Based on the SpO2 Signal.

    abstract:OBJECTIVE:This paper presents a methodology to automatically screen for sleep apnea based on the detection of apnea and hypopnea events in the blood oxygen saturation (SpO2) signal. METHODS:It starts by detecting all desaturations in the SpO2 signal. From these desaturations, a total of 143 time-domain features are ex...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2018.2817368

    authors: Deviaene M,Testelmans D,Buyse B,Borzee P,Van Huffel S,Varon C

    更新日期:2019-03-01 00:00:00

  • Toward a Wirelessly Powered On-Lens Intraocular Pressure Monitoring System.

    abstract::This paper presents a wireless on-lens intraocular pressure monitoring system, comprising a capacitance-to-digital converter and a wirelessly powered radio-frequency identification (RFID)-compatible communication system, for sensor control and data communication. The capacitive sensor was embedded on a soft contact le...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2016.2594058

    authors: Chiou JC,Hsu SH,Liao YT,Huang YC,Yeh GT,Kuei CK,Dai KS

    更新日期:2016-09-01 00:00:00

  • A Deep Learning Based Unsupervised Method to Impute Missing Values in Patient Records for Improved Management of Cardiovascular Patients.

    abstract::Physicians increasingly depend on electronic health records (EHRs) to manage patients. However, many patient records have substantial missing values that pose a fundamental challenge to their clinical use. To address this prevailing challenge, we propose an unsupervised deep-learning method that can facilitate physici...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2020.3033323

    authors: Xu D,Sheng JQ,Hu PJ,Huang TS,Hsu CC

    更新日期:2020-10-23 00:00:00

  • Performance Analysis of Gyroscope and Accelerometer Sensors for Seismocardiography-Based Wearable Pre-Ejection Period Estimation.

    abstract:OBJECTIVE:Systolic time intervals, such as the pre-ejection period (PEP), are important parameters for assessing cardiac contractility that can be measured non-invasively using seismocardiography (SCG). Recent studies have shown that specific points on accelerometer- and gyroscope-based SCG signals can be used for PEP ...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2019.2895775

    authors: Shandhi MMH,Semiz B,Hersek S,Goller N,Ayazi F,Inan OT

    更新日期:2019-11-01 00:00:00

  • Multi-Scale Time-Series Kernel-Based Learning Method for Brain Disease Diagnosis.

    abstract::The functional magnetic resonance imaging (fMRI) is a noninvasive technique for studying brain activity, such as brain network analysis, neural disease automated diagnosis and so on. However, many existing methods have some drawbacks, such as limitations of graph theory, lack of global topology characteristic, local s...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2020.2983456

    authors: Zhang Z,Ding J,Xu J,Tang J,Guo F

    更新日期:2021-01-01 00:00:00

  • Three-Dimensional Needle Shape Estimation in TRUS-Guided Prostate Brachytherapy Using 2-D Ultrasound Images.

    abstract::In this paper, we propose an automated method to reconstruct the three-dimensional (3-D) needle shape during needle insertion procedures using only 2-D transverse ultrasound (US) images. Using a set of transverse US images, image processing and random sample consensus are used to locate the needle within each image an...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2015.2477829

    authors: Waine M,Rossa C,Sloboda R,Usmani N,Tavakoli M

    更新日期:2016-11-01 00:00:00

  • Synchronization and Registration of Cine Magnetic Resonance and Dynamic Computed Tomography Images of the Heart.

    abstract::The synchronization and registration of dynamic computed tomography (CT) and magnetic resonance images (MRI) of the heart is required to perform a combined analysis of their complementary information. We propose a novel method that synchronizes and registers intrapatient dynamic CT and cine-MRI short axis view (SAX). ...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2015.2453639

    authors: Betancur J,Simon A,Langella B,Leclercq C,Hernandez A,Garreau M

    更新日期:2016-09-01 00:00:00

  • Red blood cell cluster separation from digital images for use in sickle cell disease.

    abstract::The study of cell morphology is an important aspect of the diagnosis of some diseases, such as sickle cell disease, because red blood cell deformation is caused by these diseases. Due to the elongated shape of the erythrocyte, ellipse adjustment and concave point detection are applied widely to images of peripheral bl...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2014.2356402

    authors: González-Hidalgo M,Guerrero-Peña FA,Herold-García S,Jaume-I-Capó A,Marrero-Fernández PD

    更新日期:2015-07-01 00:00:00

  • Blind end-member and abundance extraction for multispectral fluorescence lifetime imaging microscopy data.

    abstract::This paper proposes a new blind end-member and abundance extraction (BEAE) method for multispectral fluorescence lifetime imaging microscopy (m-FLIM) data. The chemometrical analysis relies on an iterative estimation of the fluorescence decay end-members and their abundances. The proposed method is based on a linear m...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2013.2279335

    authors: Gutierrez-Navarro O,Campos-Delgado DU,Arce-Santana ER,Mendez MO,Jo JA

    更新日期:2014-03-01 00:00:00

  • A Flexible Wearable Device for Measurement of Cardiac, Electrodermal, and Motion Parameters in Mental Healthcare Applications.

    abstract::Mental illnesses are vast and cause a lot of individual and social discomfort, with significant healthcare costs associated in terms of diagnosis and treatment. They can be triggered by a number of factors including stress, fatigue or anxiety. The associated physiological, cardiac and autonomic changes can be assessed...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2019.2938311

    authors: Rosa BMG,Yang GZ

    更新日期:2019-11-01 00:00:00

  • The single equivalent moving dipole model does not require spatial anatomical information to determine cardiac sources of activation.

    abstract::Radio-frequency catheter ablation (RCA) is an established treatment for ventricular tachycardia (VT). A key feature of the RCA procedure is the need for a mapping approach that facilitates the identification of the target ablation site. In this study, we investigate the effect of the location of the reference potentia...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2013.2268012

    authors: Sohn K,Lv W,Lee K,Galea AM,Hirschman GB,Hayward AM,Cohen RJ,Armoundas AA

    更新日期:2014-01-01 00:00:00

  • User-Intended Doppler Measurement Type Prediction Combining CNNs With Smart Post-Processing.

    abstract::Spectral Doppler measurements are an important part of the standard echocardiographic examination. These measurements give insight into myocardial motion and blood flow providing clinicians with parameters for diagnostic decision making. Many of these measurements are performed automatically with high accuracy, increa...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2020.3029392

    authors: Gilbert A,Holden M,Eikvil L,Rakhmail M,Babic A,Aase SA,Samset E,McLeod K

    更新日期:2020-10-07 00:00:00

  • Predicting Neonatal Sepsis Using Features of Heart Rate Variability, Respiratory Characteristics, and ECG-Derived Estimates of Infant Motion.

    abstract::This study in preterm infants was designed to characterize the prognostic potential of several features of heart rate variability (HRV), respiration, and (infant) motion for the predictive monitoring of late-onset sepsis (LOS). In a neonatal intensive care setting, the cardiorespiratory waveforms of infants with blood...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2019.2927463

    authors: Joshi R,Kommers D,Oosterwijk L,Feijs L,van Pul C,Andriessen P

    更新日期:2020-03-01 00:00:00

  • Maximizing Spectral Efficiency for Energy Harvesting-Aware WBAN.

    abstract::In this paper, we investigate the spectral efficiency of a communication link in a wireless body area network (WBAN) capable of harvesting energy from the environment. We consider two scenarios for the transmission which are single- and dual-hop and achieve the power management policy for each scenario. In the first s...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2016.2536642

    authors: Mosavat-Jahromi H,Maham B,Tsiftsis TA

    更新日期:2017-05-01 00:00:00

  • Sleep Period Time Estimation Based on Electrodermal Activity.

    abstract::We proposed and tested a method to estimate sleep period time (SPT) using electrodermal activity (EDA) signals. Eight healthy subjects and six obstructive sleep apnea patients participated in the experiments. Each subject's EDA signals were measured at the middle and ring fingers of the dominant hand during polysomnog...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2015.2490480

    authors: Hwang SH,Seo S,Yoon HN,Jung DW,Baek HJ,Cho J,Choi JW,Lee YJ,Jeong DU,Park KS

    更新日期:2017-01-01 00:00:00

  • User independent estimations of gait events with minimal sensor data.

    abstract:GOAL:The purpose of this study was to provide an initial examination of the utility of the Beta Process - Auto Regressive - Hidden Markov Model (BP-AR-HMM) for the prior identification of gait events. A secondary objective was to determine whether the output of the model could be used for classification and prediction ...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2020.3028827

    authors: Donahue S,Jin L,Hahn M

    更新日期:2020-10-05 00:00:00

  • Atrial Fibrillation Detection via Accelerometer and Gyroscope of a Smartphone.

    abstract::We present a smartphone-only solution for the detection of atrial fibrillation (AFib), which utilizes the built-in accelerometer and gyroscope sensors [inertial measurement unit, (IMU)] in the detection. Depending on the patient's situation, it is possible to use the developed smartphone application either regularly o...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2017.2688473

    authors: Lahdenoja O,Hurnanen T,Iftikhar Z,Nieminen S,Knuutila T,Saraste A,Kiviniemi T,Vasankari T,Airaksinen J,Pankaala M,Koivisto T

    更新日期:2018-01-01 00:00:00

  • 2D/3D-Display Auto-Adjustment Switch System.

    abstract::Recently, 2-D/3-D switchable displays have become the mainstream in 3-D display technologies, and people can now watch 3-D movies with a naked 2-D/3-D switchable display at home. However, some studies have indicated that people might encounter visual fatigue after enjoying a 3-D film in the theater. Although 2-D/3-D s...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2017.2700794

    authors: Lin BS,Wu PJ,Chen CY

    更新日期:2018-05-01 00:00:00

  • RACE-Net: A Recurrent Neural Network for Biomedical Image Segmentation.

    abstract::The level set based deformable models (LDM) are commonly used for medical image segmentation. However, they rely on a handcrafted curve evolution velocity that needs to be adapted for each segmentation task. The Convolutional Neural Networks (CNN) address this issue by learning robust features in a supervised end-to-e...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2018.2852635

    authors: Chakravarty A,Sivaswamy J

    更新日期:2019-05-01 00:00:00

  • Length-of-Stay Prediction for Pediatric Patients With Respiratory Diseases Using Decision Tree Methods.

    abstract::Accurate prediction of a patient's length-of-stay (LOS) in the hospital enables an efficient and effective management of hospital beds. This paper studies LOS prediction for pediatric patients with respiratory diseases using three decision tree methods: Bagging, Adaboost, and Random forest. A data set of 11,206 record...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2020.2973285

    authors: Ma F,Yu L,Ye L,Yao DD,Zhuang W

    更新日期:2020-09-01 00:00:00

  • Inaccurate Labels in Weakly-Supervised Deep Learning: Automatic Identification and Correction and Their Impact on Classification Performance.

    abstract::In data-driven deep learning-based modeling, data quality may substantially influence classification performance. Correct data labeling for deep learning modeling is critical. In weakly-supervised learning, a challenge lies in dealing with potentially inaccurate or mislabeled training data. In this paper, we proposed ...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2020.2974425

    authors: Hao D,Zhang L,Sumkin J,Mohamed A,Wu S

    更新日期:2020-09-01 00:00:00

  • Transfer Learning for Multicenter Classification of Chronic Obstructive Pulmonary Disease.

    abstract::Chronic obstructive pulmonary disease (COPD) is a lung disease that can be quantified using chest computed tomography scans. Recent studies have shown that COPD can be automatically diagnosed using weakly supervised learning of intensity and texture distributions. However, up till now such classifiers have only been e...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2017.2769800

    authors: Cheplygina V,Pena IP,Pedersen JH,Lynch DA,Sorensen L,de Bruijne M

    更新日期:2018-09-01 00:00:00

  • Validation of Static and Dynamic Balance Assessment Using Microsoft Kinect for Young and Elderly Populations.

    abstract::Reduction in balance is an indicator of fall risk, and therefore, an accurate and cost-effective balance assessment tool is essential for prescribing effective postural control strategies. This study established the validity of the Kinect v2 sensor in assessing center of mass (CoM) excursion and velocity during single...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2017.2686330

    authors: Eltoukhy MA,Kuenze C,Oh J,Signorile JF

    更新日期:2018-01-01 00:00:00

  • Deep Learning for Hemorrhagic Lesion Detection and Segmentation on Brain CT Images.

    abstract::Stroke is an acute cerebral vascular disease that is likely to cause long-term disabilities and death. Immediate emergency care with accurate diagnosis of computed tomographic (CT) images is crucial for dealing with a hemorrhagic stroke. However, due to the high variability of a stroke's location, contrast, and shape,...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2020.3028243

    authors: Li L,Wei M,Liu B,Atchaneeyasakul K,Zhou F,Pan Z,Kumar S,Zhang J,Pu Y,Liebeskind DS,Scalzo F

    更新日期:2020-10-01 00:00:00

  • Attention-Guided 3D-CNN Framework for Glaucoma Detection and Structural-Functional Association Using Volumetric Images.

    abstract::The direct analysis of 3D Optical Coherence Tomography (OCT) volumes enables deep learning models (DL) to learn spatial structural information and discover new bio-markers that are relevant to glaucoma. Downsampling 3D input volumes is the state-of-art solution to accommodate for the limited number of training volumes...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2020.3001019

    authors: George Y,Antony BJ,Ishikawa H,Wollstein G,Schuman JS,Garnavi R

    更新日期:2020-12-01 00:00:00

  • Delineation of Electrocardiograms Using Multiscale Parameter Estimation.

    abstract::The continuing interest in unobtrusive electrocardiography requires the development of algorithms, compensating for an increased number of artifacts. In previous work, we proposed a framework for robust parameter estimation of signals following a piecewise Gaussian derivative model, well suited for describing all wave...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2019.2963786

    authors: Spicher N,Kukuk M

    更新日期:2020-08-01 00:00:00

  • Assessment of Signal Processing Methods for Measuring the Respiratory Rate in the Neonatal Intensive Care Unit.

    abstract::Knowledge of the pathological instabilities in the breathing pattern can provide valuable insights into the cardiorespiratory status of the critically-ill infant as well as their maturation level. This paper is concerned with the measurement of respiratory rate in premature infants. We compare the rates estimated from...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2019.2898273

    authors: Jorge J,Villarroel M,Chaichulee S,Green G,McCormick K,Tarassenko L

    更新日期:2019-11-01 00:00:00

  • An innovative nonintrusive driver assistance system for vital signal monitoring.

    abstract::This paper describes an in-vehicle nonintrusive biopotential measurement system for driver health monitoring and fatigue detection. Previous research has found that the physiological signals including eye features, electrocardiography (ECG), electroencephalography (EEG) and their secondary parameters such as heart rat...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2014.2305403

    authors: Sun Y,Yu XB

    更新日期:2014-11-01 00:00:00