Subcortical low-intensity and restricted diffusion after first seizure in a child.

Abstract:

:Our purpose was to increase the knowledge about subcortical low-intensity images on long repetition time by describing brain magnetic resonance images of a young boy after his first spontaneous seizure. Evident in the epileptogenic area were transient images of reversible subcortical low intensity on long-repetition time, T2*-weighted, and b = 0 s/mm2 diffusion, isointense signal on b = 1000 s/mm2 diffusion, and restricted diffusion. Most likely, mechanism was axonal flow disruption with iron accumulation and free radicals production induced during seizure.

journal_name

J Comput Assist Tomogr

authors

Cerase A,Leonini S,Franceschini R,Grosso S,Venturi C

doi

10.1097/RCT.0b013e31821f5d14

subject

Has Abstract

pub_date

2011-07-01 00:00:00

pages

501-3

issue

4

eissn

0363-8715

issn

1532-3145

pii

00004728-201107000-00016

journal_volume

35

pub_type

杂志文章
  • A 6 mm collimator system for the EMI CT5000/5005 whole body scanner.

    abstract::A new 6 mm collimator for the EMI CT5000/5005 scanner is described. It consists of a narrower tube side and detector side collimator that can be set up in less than 5 min. The applications are primarily for the orbit and parasellar area. Future applications with the aid of new software include coronal reconstruction. ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-197807000-00029

    authors: Baldwin GN,Sorenson JA,Wolfley D,Canestrini R,Pritchard MJ

    更新日期:1978-07-01 00:00:00

  • Poor detection of a hepatoma with a hepatic specific contrast agent (EOE 13).

    abstract::A hepatic specific contrast agent was used in an attempt to detect a biopsy-proven hepatoma. This lesion had been missed by routine computed tomography and was poorly detected with the hepatic specific contrast agent EOE 13. It was also poorly detected by technetium-sulfur colloid hepatic scintigraphy. The true extent...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198310000-00032

    authors: Witrak BJ,Bernardino ME

    更新日期:1983-10-01 00:00:00

  • A computerized system for the elastic matching of deformed radiographic images to idealized atlas images.

    abstract::A system of computer programs is described which, for the first time, is able to use computerized tomographic data to automatically locate, measure, and describe anatomical structures of interest with accuracy and consistency. Input to the system consists of any digitized radiographic data. Computer assisted tomograph...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198308000-00008

    authors: Bajcsy R,Lieberson R,Reivich M

    更新日期:1983-08-01 00:00:00

  • Detection of thyroid pyramidal lobe by ultrasound versus computed tomography: a single-center study.

    abstract:OBJECTIVE:The prevalence and features of the thyroid pyramidal lobe (TPL) on computed tomography (CT) have been reported, but no ultrasound (US) study has been found. The purposes of the current study were to assess the sonographic prevalence and features of TPLs and to compare the US and CT parameters of TPLs. METHOD...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0000000000000054

    authors: Kim KS,Kim DW,Sung JY

    更新日期:2014-05-01 00:00:00

  • Traumatic carotid aneurysm secondary to cavernous sinus penetration by wood: CT features.

    abstract::Transorbital penetration of the cranial cavity by a small wooden object can pass unnoticed, while producing severe, life-threatening consequences. The occurrence of a traumatic intracranial aneurysm secondary to a wooden foreign body has not been reported previously in the English literature, to our knowledge. Familia...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198705000-00030

    authors: Braun J,Gdal-On M,Goldsher D,Borovich B,Guilburd JN

    更新日期:1987-05-01 00:00:00

  • Diffusion magnetic resonance imaging of solid vestibular schwannomas.

    abstract::Six patients with solid vestibular schwannomas were studied by diffusion magnetic resonance imaging to assess if this modality adds new information for these tumors, because there is no previous report in the relevant literature. The sizes of the tumors ranged from 2.2 to 4.7 cm with respect to their largest diameters...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-200303000-00024

    authors: Sener RN

    更新日期:2003-03-01 00:00:00

  • Osteonecrosis of the patella: diagnostic imaging perspective.

    abstract::Disability from knee dysfunction has important implications on a patient's performance of simple day-to-day tasks, work-related duties, and leisure activities, including sports. Diagnostic imaging is of fundamental importance in the clinical evaluation of the patient with knee pain. The use of magnetic resonance imagi...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章,评审

    doi:10.1097/01.rct.0000149235.86776.df

    authors: Theodorou SJ,Theodorou DJ,Resnick D

    更新日期:2005-01-01 00:00:00

  • CT of fibrolamellar hepatocellular carcinoma.

    abstract::We retrospectively evaluated 10 patients with pathologically proven fibrolamellar hepatocellular carcinoma (FLHCC) to assess the utility of CT (n = 9), ultrasound (n = 10), angiography (n = 9), and MR (n = 3). The tumors were solitary in 6 of 10 patients, well delineated in 7 of 10, and hypervascular in 8 of 10. With ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-199107000-00001

    authors: Soyer P,Roche A,Levesque M,Legmann P

    更新日期:1991-07-01 00:00:00

  • Pectus excavatum deformities simulating mediastinal masses.

    abstract::Three patients with various pectus excavatum deformities in whom radiographic findings suggested hilar and mediastinal masses are presented. Computed tomography of the chest yielded valuable diagnostic information and made it possible to exclude the existence of these masses. Compression deformity of the heart and gre...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-197910000-00004

    authors: Soteropoulos GC,Cigtay OS,Schellinger D

    更新日期:1979-10-01 00:00:00

  • MR imaging of the normal larynx.

    abstract::Magnetic resonance imaging of the larynx was performed on 15 volunteers. Searching for optimal images in the sagittal, frontal, and transverse planes, we compared images made with a special surface coil and the standard head coil, images with different slice thicknesses, images with different repetition times (TR) and...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198509000-00015

    authors: Castelijns JA,Doornbos J,Verbeeten B Jr,Vielvoye GJ,Bloem JL

    更新日期:1985-09-01 00:00:00

  • Myocardial bridging: evaluation using single- and dual-source multidetector cardiac computed tomographic angiography.

    abstract:OBJECTIVE:To evaluate the prevalence and characteristics of myocardial bridging in patients who underwent single- or dual-source multidetector cardiac computed tomographic angiography (MDCTA). METHODS:Retrospective review of the imaging characteristics of 57 myocardial bridges in 53 patients who underwent cardiac MDCT...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0b013e318075e6c3

    authors: Jacobs JE,Bod J,Kim DC,Hecht EM,Srichai MB

    更新日期:2008-03-01 00:00:00

  • Intrarenal rupture of the abdominal aorta: CT features.

    abstract::Computed tomography in patients with a ruptured abdominal aortic aneurysm usually demonstrates the aneurysm with blood in the posterior para- and perirenal spaces. Hemorrhage into the adjacent perirenal space occurs because the aorta, via the renal vascular pedicle, is in continuum with this compartment. The kidney is...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:

    authors: Gavant ML,Salazar JE,Ellis J

    更新日期:1986-05-01 00:00:00

  • CT of appendicitis in children.

    abstract:PURPOSE:Our goal was to review the CT findings and to help define the role of CT in the evaluation of appendicitis in children. METHOD:Of 730 children with surgically proven appendicitis, 22 underwent preoperative CT evaluation. Their CT scans and operative and pathology records were retrospectively reviewed. The CT s...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-199707000-00028

    authors: Jabra AA,Shalaby-Rana EI,Fishman EK

    更新日期:1997-07-01 00:00:00

  • Effect of New Model-Based Iterative Reconstruction on Quantitative Analysis of Airway Tree by Computer-Aided Detection Software in Chest Computed Tomography.

    abstract:OBJECTIVE:Compared the performance of computer-aided detection (CAD) software for quantitative analysis of airway using computed tomography (CT) images reconstructed with versions of model-based iterative reconstruction (MBIR) that either balances spatial and density resolution (MBIRSTND) or prefers spatial resolution ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0000000000000975

    authors: Jia Y,Zhai B,He T,Yu Y,Yu N,Duan H,Yang C,Li JY

    更新日期:2021-01-01 00:00:00

  • CT findings in partial eventration of the right diaphragm.

    abstract::Elevation of the anterior part of the right diaphragm results in the spurious radiological appearance of a mass at the right lung base. Standard chest views are usually sufficient to show the true nature of the "mass." Occasionally, however, a true mass lesion cannot be entirely excluded, and further studies are then ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198110000-00023

    authors: Rubinstein ZJ,Solomon A

    更新日期:1981-10-01 00:00:00

  • Fat attenuation lesions of the mediastinum.

    abstract::The identification of fat within a focal or diffuse mediastinal lesion significantly narrows the differential diagnosis. In many cases, a specific diagnosis can be suggested on the basis of CT findings. In this article, we illustrate and review the characteristic CT features of common and uncommon fat attenuation lesi...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章,评审

    doi:10.1097/00004728-200111000-00010

    authors: Boiselle PM,Rosado-de-Christenson ML

    更新日期:2001-11-01 00:00:00

  • A Preliminary Study of Computed Tomography Coronary Angiography Within a Single Cardiac Cycle in Patients With Atrial Fibrillation Using 256-Row Detector Computed Tomography.

    abstract:OBJECTIVE:The purpose of this study was to evaluate the image quality and radiation dose of computed tomography (CT) coronary angiography using a 256-row detector CT scanner in a single cardiac cycle in patients with atrial fibrillation (AF). METHODS:Seventy consecutive patients (41 men and 29 women; age range was fro...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0000000000000683

    authors: Wen B,Xu L,Liang J,Fan Z,Sun Z

    更新日期:2018-03-01 00:00:00

  • Nasal orientation device to control head movement during CT and MR studies.

    abstract::Cooperative patients can often keep still during a long examination of the brain provided that they are given cues about their position in space. In a U-shaped head support, the only movements likely are rotation in the sagittal or transverse planes. These can be detected by a nasal orientation device (NOD), simply a ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-199001000-00038

    authors: Tofts PS,Kermode AG,MacManus DG,Robinson WH

    更新日期:1990-01-01 00:00:00

  • Assessment of shape variation of the levator ani with optimal scan planning and statistical shape modeling.

    abstract:OBJECTIVE:To capture 3D shape variation of the levator ani during straining with open access MR imaging. METHODS:Optimal scan-planning based on statistical shape modeling is developed for recovering the entire 3D structure of the levator ani from a limited number of 2D imaging planes. Statistical shape modeling ensure...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/01.rct.0000155076.42784.ed

    authors: Lee SL,Horkaew P,Caspersz W,Darzi A,Yang GZ

    更新日期:2005-03-01 00:00:00

  • Organ volume determination by CT scanning: reduction of respiration-induced errors by feedback monitoring.

    abstract::Computed tomography potentially provides an accurate means of determining organ volume, by summation of serial section areas. Variation in level of held respiration for each serial scan, however, severely limits accuracy in the thorax and upper abdomen. A simple strain gauge has been used to provide the patient with v...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198601000-00042

    authors: Jones KR,Robinson PJ

    更新日期:1986-01-01 00:00:00

  • Spontaneous hepatic hemorrhage: clinical and CT findings.

    abstract::The clinical records and radiologic findings in six patients with spontaneous (nontraumatic) intrahepatic and subcapsular hemorrhage were reviewed. Four patients had underlying liver lesions (hepatocellular carcinoma and metastasis from B-cell lymphoma in one patient each and hepatic adenoma in two other patients). On...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198805010-00007

    authors: Merine D,Fishman EK,Zerhouni EA

    更新日期:1988-05-01 00:00:00

  • Quantitative Assessment of Extracellular Volume in Doxorubicin-Induced Liver Injury in Beagle Models by Equilibrium Computed Tomography.

    abstract:PURPOSE:The purpose of this study was to determine whether liver extracellular volume (ECV) measured using equilibrium computed tomography (EQ-CT) can be used to quantitatively assess doxorubicin-induced liver injury (DILI). METHODS:The ethical approval was obtained from the Institutional Animal Care and Use Committee...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0000000000000968

    authors: Han P,Zhou Z,Wang R,Wang H,Sun Z,Wang X,Xu L

    更新日期:2020-03-01 00:00:00

  • Application of Gemstone Spectral Computed Tomography Imaging in the Characterization of Solitary Pulmonary Nodules: Preliminary Result.

    abstract:OBJECTIVE:This study aimed to observe the value of computed tomography (CT) spectral imaging parameters in the diagnosis of solitary pulmonary nodules, during the contrast-enhanced early phase and late phase. MATERIALS AND METHODS:This study was approved by the institutional review board and written informed consent w...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0000000000000469

    authors: Lin JZ,Zhang L,Zhang CY,Yang L,Lou HN,Wang ZG

    更新日期:2016-11-01 00:00:00

  • MR appearance of sternal hyperostosis.

    abstract::Sternal hyperostosis is characterized by prominent new bone formation and fibrosis with less pronounced areas of granulation tissue and round cell infiltration. In previously reported cases the process involved not only the sternum but adjacent bony areas as well. Depending upon the extent of disease, acquiring biopsy...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-199001000-00028

    authors: Bechtold RE,Karstaedt N,Wolfman NT

    更新日期:1990-01-01 00:00:00

  • Masses and pseudomasses of the kidney: imaging spectrum on MR.

    abstract::MR imaging is useful in differentiating and characterizing renal masses. A careful evaluation of the signal characteristics and morphology of a renal mass combined with the ancillary imaging findings and patient history should assist the radiologist in making the proper diagnosis or recommending the appropriate treatm...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章,评审

    doi:10.1097/01.rct.0000135278.89314.60

    authors: Zhang J,Israel GM,Krinsky GA,Lee VS

    更新日期:2004-09-01 00:00:00

  • MR-monitored remitting-relapsing pattern of cortical involvement in Rasmussen syndrome: comparative evaluation of serial MR and PET/SPECT features.

    abstract::We report the serial MR and PET/SPECT findings in a 2 1/2-year-old boy presenting with Rasmussen syndrome and highlight the close qualitative correlations between the results of the imaging modality and the functional isotopic techniques. The latter demonstrated a wider field of extension of the disease process. Routi...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-199711000-00010

    authors: Duprez TP,Grandin C,Gadisseux JF,De Volder A,Thauvoy C,Keyeux A,Evrard P

    更新日期:1997-11-01 00:00:00

  • Ruptured endometrial cysts as a rare cause of acute pelvic pain: can we differentiate them from ruptured corpus luteal cysts on CT scan?

    abstract:PURPOSE:To evaluate the usefulness of CT in the differentiation of ruptured endometrial cysts and corpus luteal cysts. METHODS:Sixteen patients (mean age, 26 years) with a surgically proven ruptured endometrial cyst and 19 patients (mean age, 28 years) with a surgically proven corpus luteal cyst were included in this ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0b013e31821f4bd2

    authors: Choi NJ,Rha SE,Jung SE,Choi BG,Oh SN,Byun JY,Kim MR

    更新日期:2011-07-01 00:00:00

  • Comparison of Dynamic Phase Enhancement of Hepatocellular Carcinoma Using Gadoxetate Disodium vs Gadobenate Dimeglumine.

    abstract:OBJECTIVE:To determine the differences in enhancement of hepatocellular carcinoma during the first 5 minutes of postcontrast phases with gadoxetic acid (Gd-EOB-DTPA) vs gadobenate dimeglumine. METHODS:Ninety-five cirrhotic patients with hepatocellular carcinoma were examined on a 1.5-T scanner: 74 patients with Gd-BOP...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0000000000000234

    authors: Tirkes T,Mehta P,Aisen AM,Lall C,Akisik F

    更新日期:2015-07-01 00:00:00

  • Percutaneous CT-guided biopsy: improved confirmation of sampling site and needle positioning using a multistep technique at CT fluoroscopy.

    abstract::We describe a new multistep procedure for CT fluoroscopy-guided core biopsy, which allows confirmation of the biopsy-sampling trough and the final needle tip position prior to sampling. Twelve lesions measuring < or =2 cm or in close proximity to vital structures were biopsied using commercially available biopsy syste...

    journal_title:Journal of computer assisted tomography

    pub_type: 临床试验,杂志文章

    doi:10.1097/00004728-200003000-00015

    authors: Goldberg SN,Keogan MT,Raptopoulos V

    更新日期:2000-03-01 00:00:00

  • Iodine Quantification Using Dual-Energy Computed Tomography for Differentiating Thymic Tumors.

    abstract::The aim of the study was to explore the efficacy of iodine quantification with dual-energy computed tomography (DECT) in differentiating thymoma, thymic carcinoma, and thymic lymphoma. MATERIALS AND METHODS:Fifty-seven patients with pathologically confirmed low-risk thymoma (n = 16), high-risk thymoma (n = 15), thymi...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0000000000000800

    authors: Yan WQ,Xin YK,Jing Y,Li GF,Wang SM,Rong WC,Xiao G,Lei XB,Li B,Hu YC,Cui GB