Radiologists' performance in the detection of benign and malignant masses with 3D automated breast ultrasound (ABUS).

Abstract:

OBJECTIVES:To retrospectively evaluate the detection performance of benign and malignant breast masses using 3D volume data obtained by ABUS and to determine lesion variables which affect detectability. METHODS:Between November and December of 2007, bilateral whole breast US images were obtained using ABUS in 67 consecutive women who were scheduled to undergo US-guided needle biopsy due to suspicious breast masses. Twenty-four invasive ductal cancers in 23 breasts, 46 benign breast lesions in 44 breasts and 38 normal breasts were included. Three breast radiologists (experience range, 8-16 years) who did not perform the examinations and were blinded to the histology independently reviewed the ABUS data of the 105 breasts to detect suspicious solid masses with pathology as the standard of reference. Sensitivity and specificity in detecting benign and malignant masses were calculated, and lesion characteristics affecting detectability were analyzed. RESULTS:Sensitivities for benign and malignant mass detections were 65.2% (30/46), 95.8% (23/24) for reader 1 (p=0.007), 66.7% (31/46), 87.5% (21/24) for reader 2 (p=0.087), and 56.3% (24/46), 91.7% (22/24), for reader 3 (p=0.001), respectively. Logistic analysis showed that mass size (odds ratio, 95% CI; 1.12, 1.02-1.24), surrounding tissue changes (odds ratio, 95% CI; 0.11, 0.02-0.47), and shape of the mass (odds ratio, 95% CI; 3.12, 1.02-9.55) were the variables associated with detectability at ABUS. CONCLUSION:In reader studies using ABUS data, significantly higher sensitivity was noted for malignant breast masses than for benign masses.

journal_name

Eur J Radiol

authors

Chang JM,Moon WK,Cho N,Park JS,Kim SJ

doi

10.1016/j.ejrad.2011.01.074

subject

Has Abstract

pub_date

2011-04-01 00:00:00

pages

99-103

issue

1

eissn

0720-048X

issn

1872-7727

pii

S0720-048X(11)00113-6

journal_volume

78

pub_type

杂志文章
  • Bone marrow oedema associated with benign and malignant bone tumours.

    abstract::Bone marrow oedema is associated with a wide variety of pathological processes including both benign and malignant bone tumours. This imaging finding in relation to intraosseous tumours can aid in providing a more focused differential diagnosis. In this review, we will discuss the MR imaging of bone marrow oedema surr...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2008.01.052

    authors: James SL,Panicek DM,Davies AM

    更新日期:2008-07-01 00:00:00

  • Computed tomography in maple syrup urine disease.

    abstract::Maple Syrup Urine Disease (MSUD) is an inherited metabolic disorder characterized by a severe, usually lethal, neonatal course in the early stages with pseudotumor cerebri and pathologically documented increased cerebral water content. CT and MRI studies in MSUD are few and the data are overlapping. This study reports...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/0720-048x(92)90089-r

    authors: Taccone A,Schiaffino MC,Cerone R,Fondelli MP,Romano C

    更新日期:1992-05-01 00:00:00

  • Image quality of early postoperative CT angiography with reduced contrast material and radiation dose using model-based iterative reconstruction for screening of renal pseudoaneurysms after partial nephrectomy.

    abstract:PURPOSE:To evaluate the image quality of early postoperative CT angiography with low contrast material and radiation dose using model-based iterative reconstruction (FIRST) for screening pseudoaneurysms after partial nephrectomy. METHODS:CT angiography was obtained before surgery using conventional iterative dose redu...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2020.108853

    authors: Morita S,Ogawa Y,Yamamoto T,Kamoshida K,Yamazaki H,Suzuki K,Sakai S,Kunihara M,Takagi T,Tanabe K

    更新日期:2020-03-01 00:00:00

  • Quantifying metal artefact reduction using virtual monochromatic dual-layer detector spectral CT imaging in unilateral and bilateral total hip prostheses.

    abstract:PURPOSE:To quantify the impact of prosthesis material and design on the reduction of metal artefacts in total hip arthroplasties using virtual monochromatic dual-layer detector Spectral CT imaging. METHODS:The water-filled total hip arthroplasty phantom was scanned on a novel 128-slice Philips IQon dual-layer detector...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2017.01.002

    authors: Wellenberg RH,Boomsma MF,van Osch JA,Vlassenbroek A,Milles J,Edens MA,Streekstra GJ,Slump CH,Maas M

    更新日期:2017-03-01 00:00:00

  • Scaphoid nonunions treated with vascularised bone grafts: MRI assessment.

    abstract:PURPOSE:To assess the value of MR imaging (MRI) with regard to union, graft viability and proximal pole bone marrow status, after use of vascularized bone grafts for treating scaphoid nonunions. MATERIALS AND METHODS:Vascularized bone grafts from the distal radius were used to treat 47 scaphoid nonunions resulting fro...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2004.01.017

    authors: Dailiana ZH,Zachos V,Varitimidis S,Papanagiotou P,Karantanas A,Malizos KN

    更新日期:2004-06-01 00:00:00

  • Overview of the radiology of juvenile idiopathic arthritis (JIA).

    abstract::Plain films remain the basic tool for diagnosis and follow-up evaluation of juvenile idiopathic arthritis (JIA). In this paper, we review the new classification of JIA: systemic arthritis. oligoarthritis (persistent), oligoarthritis (extended), polyarticular arthritis (rheumatoid factor negative), polyarticular arthri...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/s0720-048x(99)00152-7

    authors: Cohen PA,Job-Deslandre CH,Lalande G,Adamsbaum C

    更新日期:2000-02-01 00:00:00

  • Comparison of three-dimensional negative-contrast CT cholangiopancreatography with three-dimensional MR cholangiopancreatography for the diagnosis of obstructive biliary diseases.

    abstract:PURPOSE:The purpose of our study was to compare three-dimensional (3D) negative-contrast CT cholangiopancreatography (3D-nCTCP) with 3D MR cholangiopancreatography (3D-MRCP) for the diagnosis of obstructive biliary diseases. MATERIALS AND METHODS:3D-nCTCP and 3D-MRCP were performed on seventy clinically documented obs...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2011.02.036

    authors: Zhang ZY,Wang D,Ni JM,Yu XR,Zhang L,Wu WJ,Gong L,Hu MH

    更新日期:2012-05-01 00:00:00

  • Fecal-tagging CT colonography with structure-analysis electronic cleansing for detection of colorectal flat lesions.

    abstract:PURPOSE:To evaluate the feasibility and sensitivity of the 3D-reading of fecal-tagging CT colonography (CTC) with a novel structure-analysis electronic cleansing (SAEC) in detecting colorectal flat lesions in comparison with a cleansed 3D reading with Viatronix V3D Colon system (V3D) and primary uncleansed 2D reading (...

    journal_title:European journal of radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1016/j.ejrad.2011.04.051

    authors: Xu Y,Cai W,Nappi J,Yoshida H

    更新日期:2012-08-01 00:00:00

  • Analysis of left atrial appendix by dual-source CT coronary angiography: morphologic classification and imaging by volume rendered CT images.

    abstract:AIM:We investigated the evaluability of left atrial appendix by dual source coronary CT angiography and analyzed morphologic features. MATERIALS AND METHODS:We included 106 consecutive patients who underwent coronary CT angiography for various indications. Technical parameters were slice thickness 0.6 mm, reconstructi...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2010.11.008

    authors: Erol B,Karcaaltincaba M,Aytemir K,Cay N,Hazirolan T,Akata D

    更新日期:2011-12-01 00:00:00

  • Multiphase CT scanning and different intravenous contrast media concentrations in combined F-18-FDG PET/CT: Effect on quantitative and clinical assessment.

    abstract:PURPOSE:To evaluate the influence of multiphase CT scanning and different intravenous contrast media on contrast enhancement, attenuation correction and image quality in combined PET/CT. MATERIAL AND METHODS:140 patients were prospectively enrolled for F-18-FDG-PET/CT including a low-dose unenhanced, arterial and veno...

    journal_title:European journal of radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.ejrad.2012.04.007

    authors: Rebière M,Verburg FA,Palmowski M,Krohn T,Pietsch H,Kuhl CK,Mottaghy FM,Behrendt FF

    更新日期:2012-08-01 00:00:00

  • Digital breast tomosynthesis and breast ultrasound: Additional roles in dense breasts with category 0 at conventional digital mammography.

    abstract:PURPOSE:To compare the diagnostic performances of digital breast tomosynthesis (DBT) and ultrasound for the dense breasts with category 0 at conventional digital mammography. MATERIALS AND METHODS:This retrospective study was approved by the institutional review board, and informed consent was waived. Among the 1103 p...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2015.09.026

    authors: Lee WK,Chung J,Cha ES,Lee JE,Kim JH

    更新日期:2016-01-01 00:00:00

  • A correlative study of aortic valve rotation angle and thoracic aortic sizes using ECG gated CT angiography.

    abstract:OBJECTIVE:Various degrees of aortic valve rotation may be seen in individuals with no history of congenital cardiovascular malformations, but its association with aortic sizes has not been studied. METHODS:Gated computed tomographic (CT angiograms in 217 patients were studied (66.7±15; 22-97 years old)). Aortic diamet...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2017.01.009

    authors: Saremi F,Cen S,Tayari N,Alizadeh H,Emami A,Lin L,Fleischman F

    更新日期:2017-04-01 00:00:00

  • Peri-aortic fluid after surgery on the ascending aorta: Worrisome indicator of complications or innocent postoperative finding?

    abstract:OBJECTIVE:The Bentall procedure is associated with several complications often accompanied by accumulation of fluid around the aortic graft. CT is the imaging modality of choice to detect these complications. Since these early complications are, however, not easily distinguished from physiological postoperative changes...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2017.09.001

    authors: Boccalini S,Swart LE,Bekkers JA,Nieman K,Krestin GP,Bogers AJJC,Budde RPJ

    更新日期:2017-10-01 00:00:00

  • Right ventricular long axis strain-validation of a novel parameter in non-ischemic dilated cardiomyopathy using standard cardiac magnetic resonance imaging.

    abstract:PURPOSE:Right ventricular longitudinal axis strain (RV-LAS) is a simple measure of RV longitudinal function. The purpose of this study was the evaluation of its diagnostic performance in non-ischemic dilated cardiomyopathy (NIDCM) and the determination of reference values in controls. METHODS:217 NIDCM patients and 20...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2016.04.017

    authors: Arenja N,Riffel JH,Djiokou CN,Andre F,Fritz T,Halder M,Zelniker T,Kristen AV,Korosoglou G,Katus HA,Buss SJ

    更新日期:2016-07-01 00:00:00

  • Assessment and quantification of sources of variability in breast apparent diffusion coefficient (ADC) measurements at diffusion weighted imaging.

    abstract:PURPOSE:Apparent Diffusion Coefficient (ADC) measurements are increasingly used for assessing breast cancer response to neoadjuvant chemotherapy although little data exists on ADC measurement reproducibility. The purpose of this work was to investigate and characterise the magnitude of errors in ADC measures that may b...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2015.05.032

    authors: Giannotti E,Waugh S,Priba L,Davis Z,Crowe E,Vinnicombe S

    更新日期:2015-09-01 00:00:00

  • The influence of knee malalignment on the ankle alignment in varus and valgus gonarthrosis based on radiographic measurement.

    abstract:PURPOSE:The lower limb misalignment as calculated by radiography has an evident effect on the development and progression of knee osteoarthritis (OA). However, whether the knee malalignment has an influence on ankle alignment is unknown. The purpose of this study was to discuss the correlation between knee and ankle al...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2015.11.021

    authors: Gao F,Ma J,Sun W,Guo W,Li Z,Wang W

    更新日期:2016-01-01 00:00:00

  • Measurement of canine pancreatic perfusion using dynamic computed tomography: influence of input-output vessels on deconvolution and maximum slope methods.

    abstract:OBJECTIVE:We investigated whether the prerequisite of the maximum slope and deconvolution methods are satisfied in pancreatic perfusion CT and whether the measured parameters between these algorithms are correlated. METHODS:We examined nine beagles injected with iohexol (200 mgI kg(-1)) at 5.0 ml s(-1). The abdominal ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2009.06.016

    authors: Kishimoto M,Tsuji Y,Katabami N,Shimizu J,Lee KJ,Iwasaki T,Miyake Y,Yazumi S,Chiba T,Yamada K

    更新日期:2011-01-01 00:00:00

  • Quantitative 3D pulmonary MR-perfusion in patients with pulmonary arterial hypertension: correlation with invasive pressure measurements.

    abstract:PURPOSE:Pathological changes of the peripheral pulmonary arteries induce pulmonary arterial hypertension (PAH). Aim of this study was to quantitatively assess the effect of PAH on pulmonary perfusion by 3D-MR-perfusion techniques and to compare findings to healthy controls. Furthermore, quantitative perfusion data were...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2006.08.028

    authors: Ley S,Mereles D,Risse F,Grünig E,Ley-Zaporozhan J,Tecer Z,Puderbach M,Fink C,Kauczor HU

    更新日期:2007-02-01 00:00:00

  • The efficacy of intraperitoneal saline infusion for percutaneous radiofrequency ablation for hepatocellular carcinoma.

    abstract:OBJECTIVE:To evaluated the efficacy and safety of radiofrequency ablation (RFA) with intraperitoneal saline infusion. BACKGROUND:Ultrasound-guided RFA is not always feasible due to the tumor location, possible adjacent tissue damage or poor sonographic identification. PATIENTS AND METHODS:Ultrasound-guided RFA with i...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2009.03.037

    authors: Park SY,Tak WY,Jeon SW,Cho CM,Kweon YO,Kim SK,Choi YH

    更新日期:2010-06-01 00:00:00

  • Mesenchymal hamartoma of the liver in infant: its roentgen diagnosis.

    abstract::A case of mesenchymal hamartoma of the liver in an 18-month-old boy is reported. CT and US revealed a large, cystic tumour surrounded by a thick wall. In the lower portion of the tumour, a small solid component was recognized on CT. Angiography revealed marked arterial displacement, fine tumour vessels and a large rad...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:

    authors: Egawa T,Kuroda C,Yoshioka H,Hori S,Tokunaga K,Fukui Y,Ikeda Y,Okada A,Sakurai M

    更新日期:1983-11-01 00:00:00

  • Quantitative MRI in post-operative paediatric cerebellar mutism syndrome.

    abstract::Post-operative paediatric cerebellar mutism syndrome (pCMS) occurs in around 25% of children undergoing surgery for cerebellar and fourth ventricular tumours. Reversible mutism is the hallmark of a syndrome which comprises severe motor, cognitive and linguistic deficits. Recent evidence from advanced neuroimaging stud...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2018.09.007

    authors: Toescu SM,Hales PW,Aquilina K,Clark CA

    更新日期:2018-11-01 00:00:00

  • CT diagnosis of pedunculated liver tumours.

    abstract::Liver tumours with extrahepatic location are uncommon. They show specific CT criteria with respect to blood supply. Various CT criteria have been analysed in 10 tumours, including three hepatocellular adenomas, two focal nodular hyperplasias, four cavernous haemangiomas and one hepatocellular carcinoma. Correct diagno...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:

    authors: Lüning M,Mühler A

    更新日期:1988-11-01 00:00:00

  • Subsecond multi-slice computed tomography: basics and applications.

    abstract::The recent advent of multislice-scanning is the first real quantum leap in computed tomography since the introduction of spiral CT in the early 90s. We discuss basic theoretical considerations important for the design of multislice scanners. Then, specific issues, like the design of the detector and spiral interpolati...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/s0720-048x(99)00086-8

    authors: Klingenbeck-Regn K,Schaller S,Flohr T,Ohnesorge B,Kopp AF,Baum U

    更新日期:1999-08-01 00:00:00

  • Juxta-adrenal schwannoma: dynamic multi-slice CT and MRI findings.

    abstract:BACKGROUND:We retrospectively analyzed the MSCT and MRI findings of three cases of juxta-adrenal schwannoma and reviewed literature. METHODS AND RESULTS:Three patients were male, and showed no signs for endocrine activity. The three cases of juxta-adrenal schwannoma were all well-circumscribed, oval masses with cystic...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2011.01.082

    authors: Liu QY,Gao M,Li HG,Lin XF,Huang SQ,Liang BL

    更新日期:2012-04-01 00:00:00

  • Comparison of acquired diffusion weighted imaging and computed diffusion weighted imaging for detection of hepatic metastases.

    abstract:OBJECTIVE:To compare the accuracy of acquired diffusion weighted imaging (DWI) (b=1000 s/mm(2)) with that of computed DWI (b=1000 s/mm(2)) for the detection of hepatic metastases. METHODS:Two hundred and sixty patients underwent abdominal magnetic resonance imaging (MRI) at 3.0 T for the evaluation of hepatic metastas...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2012.10.020

    authors: Shimizu H,Isoda H,Fujimoto K,Kawahara S,Furuta A,Shibata T,Togashi K

    更新日期:2013-03-01 00:00:00

  • From protein-protein interaction to therapy response: molecular imaging of heat shock proteins.

    abstract::HSP70 promoter-driven gene therapy and inhibition of HSP90 activity with small molecule inhibitors are two shining points in a newly developed cohort of cancer treatment. For HSP70 promoters, high efficiency and heat inducibility within a localized region make it very attractive to clinical translation. The HSP90 inhi...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2009.01.052

    authors: Niu G,Chen X

    更新日期:2009-05-01 00:00:00

  • Pancreatic ductal adenocarcinoma and chronic mass-forming pancreatitis: Differentiation with dual-energy MDCT in spectral imaging mode.

    abstract:OBJECTIVE:To investigate the value of dual-energy MDCT in spectral imaging in the differential diagnosis of chronic mass-forming chronic pancreatitis (CMFP) and pancreatic ductal adenocarcinoma (PDAC) during the arterial phase (AP) and the pancreatic parenchymal phase (PP). MATERIALS AND METHODS:Thirty five consecutiv...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2015.09.023

    authors: Yin Q,Zou X,Zai X,Wu Z,Wu Q,Jiang X,Chen H,Miao F

    更新日期:2015-12-01 00:00:00

  • CT features of retroperitoneal neurilemmoma.

    abstract:PURPOSE:The aim of this study was to characterize the CT features of retroperitoneal neurilemmoma. METHODS:The CT findings were reviewed in seven patients with retroperitoneal neurilemmoma. RESULTS:All of the tumours were well-demarcated round or oval masses. In five cases, heterogeneous contrast enhancement was note...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/s0720-048x(97)00032-6

    authors: Kinoshita T,Naganuma H,Ishii K,Itoh H

    更新日期:1998-03-01 00:00:00

  • Application of artificial intelligence in cardiac CT: From basics to clinical practice.

    abstract::Research into the possibilities of AI in cardiac CT has been growing rapidly in the last decade. With the rise of publicly available databases and AI algorithms, many researchers and clinicians have started investigations into the use of AI in the clinical workflow. This review is a comprehensive overview on the types...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2020.108969

    authors: van den Oever LB,Vonder M,van Assen M,van Ooijen PMA,de Bock GH,Xie XQ,Vliegenthart R

    更新日期:2020-07-01 00:00:00

  • Evaluation of hypervascular hepatocellular carcinoma in cirrhotic liver: comparison of different concentrations of contrast material with multi-detector row helical CT--a prospective randomized study.

    abstract:PURPOSE:To evaluate two different iodine concentrations of contrast material for detecting hypervascular hepatocellular carcinomas (HCCs) in cirrhotic liver by multi-detector row helical CT (MDCT) when a fixed contrast material volume and injection rate is used. MATERIALS AND METHODS:Institutional Review Board approva...

    journal_title:European journal of radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.ejrad.2010.10.006

    authors: Sofue K,Tsurusaki M,Kawasaki R,Fujii M,Sugimura K

    更新日期:2011-12-01 00:00:00