Computer-aided volumetric comparison of reconstructed orbits for blow-out fractures with nonpreformed versus 3-dimensionally preformed titanium mesh plates: a preliminary study.

Abstract:

OBJECTIVES:To compare and evaluate, using computer-aided volumetric measurements, the accuracy and reliability of nonpreformed mesh plates (NPMPs) versus 3-dimensionally preformed titanium mesh plates (PMPs) in posttraumatic orbital volume restoration. PATIENTS AND METHODS:Facial coronal computed tomographic scan slices from 20 patients (10 in the NPMP and 10 in the PMP group) were used to measure bony orbital volume using OsiriX Medical Image software (version 3.3.2, www.osirix-viewer.com). The procedure was performed on both orbits; thereafter, the volume of the contralateral health orbit was used as a control for comparison in the 2 groups of patients. The difference in orbital volume between the 2 groups and between the reconstructed versus uninjured side in both groups have been statistically correlated. RESULTS:The mean orbital volume between the reconstructed (19.215 mL in NPMP and 21.791 mL in PMP) and the contralateral uninjured side (18.955 mL in NPMP and 21.710 mL in PMP) was not statistically significant (P > 0.05). The mean orbital volumes of the reconstructed orbits were 19.215 mL in the NPMP and 21.791 mL in the PMP group, with no statistically significant difference (P > 0.05). The volume data of the reconstructed orbit fitted that of the contralateral uninjured orbit with an accuracy of a maximum of 1.85 mL in the NPMP group and 2.5 mL in the PMP group. CONCLUSIONS:The current study demonstrated that there were no significant differences in the orbital volume restoration using either technique. In fact, both techniques allow for close reproduction of natural orbital volume and shape, and its use in posttraumatic orbital wall reconstruction was successful.

journal_name

J Comput Assist Tomogr

authors

Scolozzi P,Momjian A,Heuberger J

doi

10.1097/RCT.0b013e3181ac1975

subject

Has Abstract

pub_date

2010-01-01 00:00:00

pages

98-104

issue

1

eissn

0363-8715

issn

1532-3145

pii

00004728-201001000-00018

journal_volume

34

pub_type

杂志文章
  • High resolution CT findings in miliary lung disease.

    abstract::High-resolution CT (HRCT) and chest radiographs were compared in nine patients with miliary lung disease. In all cases, miliary disease was documented to be infectious in etiology; six of these patients proved to be human immunodeficiency virus (HIV) positive. A mixture of both sharply and poorly defined 1-3 mm nodule...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-199205000-00009

    authors: McGuinness G,Naidich DP,Jagirdar J,Leitman B,McCauley DI

    更新日期:1992-05-01 00:00:00

  • Computed tomography in moyamoya disease.

    abstract::Eighteen patients with moyamoya disease were examined by computed tomography (CT). At the first examination, CT findings were normal in one patient and abnormal in 17 patients. Significant abnormalities on precontrast CT were characterized by low density lesions in 14, ventricular dilatation in 9, and cerebral atrophy...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198202000-00003

    authors: Takeuchi S,Kobayashi K,Tsuchida T,Imamura H,Tanaka R,Ito J

    更新日期:1982-02-01 00:00:00

  • Narrow superior mediastinum and pseudomasses: CT features.

    abstract::The authors report three cases of abnormal chest radiography mimicking mediastinal masses. These radiographic findings were unrelated to any pathology, were discovered in asymptomatic patients, and must be considered consequences of unusually narrow thoracic inlets. Mean and standard deviations of the anteroposterior ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198607000-00011

    authors: Jardin M,Lemaitre L,Remy J

    更新日期:1986-07-01 00:00:00

  • Hepatic involvement in hereditary hemorrhagic telangiectasia: helical computed tomography features in 24 consecutive patients.

    abstract:OBJECTIVE:Among the various organs that may be affected by hereditary hemorrhagic telangiectasia (HHT), the liver can show various degrees of vascular and parenchymal involvement. The purpose of this prospective study comprising a large series of patients was to reassess the computed tomography (CT) features of hepatic...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-200407000-00009

    authors: Ravard G,Soyer P,Boudiaf M,Terem C,Abitbol M,Yeh JF,Brouard R,Hamzi L,Rymer R

    更新日期:2004-07-01 00:00:00

  • Further Improving Image Quality of Cardiovascular Computed Tomography Angiography for Children With High Heart Rates Using Second-Generation Motion Correction Algorithm.

    abstract:BACKGROUND:The state-of-art motion correction algorithm is inadequate for correcting motion artifacts in coronary arteries in cardiovascular computed tomography angiography (CCTA) for children with high heart rates, and even less effective for heart structures beyond coronary arteries. PURPOSE:This study aimed to eval...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0000000000001035

    authors: Sun J,Okerlund D,Cao Y,Li H,Zhu Y,Li J,Peng Y

    更新日期:2020-09-01 00:00:00

  • A preliminary investigation of computed tomographic angiography in the assessment of coronary artery distensibility.

    abstract:OBJECTIVE:To test 2 hypotheses: first, that coronary distensibility can be measured noninvasively using 64-slice computed tomographic angiography (CTA); and second, that the extent of coronary artery disease (CAD) in any individual patient is related to the degree of distensibility detected by CTA. MATERIALS AND METHO...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0000000000000068

    authors: Zhang JY,Li YH,Li MH,Pan JW

    更新日期:2014-05-01 00:00:00

  • CT findings in malignant tumors of thymic epithelium.

    abstract:OBJECTIVE:Differentiation of invasive thymoma from thymic carcinoma is important because of their different clinical behaviors. Retrospectively, we evaluated the CT findings of invasive thymomas and thymic carcinomas to determine the differential points between them. MATERIALS AND METHODS:We reviewed the CT scans of 1...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-199503000-00005

    authors: Do YS,Im JG,Lee BH,Kim KH,Oh YW,Chin SY,Zo JI,Jang JJ

    更新日期:1995-03-01 00:00:00

  • Utilization of cross-plane rays for three-dimensional reconstruction by filtered back-projection.

    abstract::Present popular computed tomography (CT) algorithms reconstruct an object from the ray measurements lying on a set of parallel planes. This paper presents an algorithm that can also utilize "cross-plane" rays (i.e., rays that cross through many planes) to reconstruct the object. In this reconstruction algorithm, the r...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-197906000-00015

    authors: Pelc NJ,Chesler DA

    更新日期:1979-06-01 00:00:00

  • Effect of New Model-Based Iterative Reconstruction on Quantitative Analysis of Airway Tree by Computer-Aided Detection Software in Chest Computed Tomography.

    abstract:OBJECTIVE:Compared the performance of computer-aided detection (CAD) software for quantitative analysis of airway using computed tomography (CT) images reconstructed with versions of model-based iterative reconstruction (MBIR) that either balances spatial and density resolution (MBIRSTND) or prefers spatial resolution ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0000000000000975

    authors: Jia Y,Zhai B,He T,Yu Y,Yu N,Duan H,Yang C,Li JY

    更新日期:2021-01-01 00:00:00

  • Diagnostic Value of Global Cardiac Strain in Patients With Myocarditis.

    abstract:BACKGROUND:Cardiac strain represents an imaging biomarker of contractile dysfunction. PURPOSE:The purpose of this study was to investigate the diagnostic value of cardiac strain obtained by feature-tracking cardiac magnetic resonance (MR) in acute myocarditis. MATERIALS AND METHODS:Cardiac MR examinations of 46 patie...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0000000000001062

    authors: Secchi F,Monti CB,Alì M,Carbone FS,Cannaò PM,Sardanelli F

    更新日期:2020-07-01 00:00:00

  • Accurate determination of metabolic rates from dynamic positron emission tomography data with very-low temporal resolution.

    abstract:PURPOSE:The graphical approach is widely used for the pixelwise determination of local metabolic rate of glucose from dynamic positron emission tomography (PET) data. In its conventional implementation, measured integrals over time frames are used to approximate instantaneous tracer concentrations at midframe times ("m...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-200307000-00026

    authors: Buchert R,van den Hoff J,Mester J

    更新日期:2003-07-01 00:00:00

  • Computed tomography of renal vein thrombosis.

    abstract::We reviewed our clinical experience of the past 1 1/2 years using computed tomography (CT) in cases of suspected renal vein thrombosis; we detected three cases and correctly excluded renal vein thrombosis in an additional three patients. Because of our limited clinical experience, we surgically created left renal vein...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:

    authors: Glazer GM,Francis IR,Gross BH,Amendola MA

    更新日期:1984-04-01 00:00:00

  • Multidetector computed tomography and blunt thoracoabdominal trauma.

    abstract::Computed tomography has had an increasing role in the evaluation of patients after blunt trauma. Important findings in thoracic trauma include acute traumatic aortic injury, pneumothorax, hemothorax, pulmonary contusions and lacerations, mediastinal hematoma, and diaphragmatic rupture. The solid abdominal viscera may ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章,评审

    doi:10.1097/01.rct.0000120858.80935.59

    authors: Mullinix AJ,Foley WD

    更新日期:2004-07-01 00:00:00

  • Congested deep subcortical veins as a sign of dural venous thrombosis: MR and CT correlations.

    abstract::Dural venous thrombosis can have a rapidly progressive fatal course if unrecognized; its clinical picture is often confusing. Numerous CT, magnetic resonance (MR), and angiographic findings have been described to help recognize this entity. We present a case of dilated transcerebral medullary veins as a sign of superi...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198711000-00028

    authors: Anderson SC,Shah CP,Murtagh FR

    更新日期:1987-11-01 00:00:00

  • Subacute coronary artery thrombosis: MRI findings.

    abstract::The article presents a case of subacute coronary artery thrombosis investigated by classic methods, coronary angiography, and MRI. T1- and T2-weighted images showed high signal intensity within the lumen of the right coronary artery corresponding to the methemoglobin content of the thrombus. Dynamic sequence images wi...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-199711000-00020

    authors: Borelli C,Berthezene Y,Olteanu B,Croisille P,Bendib K,Finet G,Amiel M

    更新日期:1997-11-01 00:00:00

  • Assessment of Myometrial Invasion in Premenopausal Grade 1 Endometrial Carcinoma: Is Magnetic Resonance Imaging a Reliable Tool in Selecting Patients for Fertility-Preserving Therapy?

    abstract:OBJECTIVES:The aim of this study was to evaluate the diagnostic ability of magnetic resonance imaging (MRI) in premenopausal women with G1 endometrial carcinoma. METHODS:Twenty-six patients underwent T2W, diffusion weighted, and dynamic contrast-enhanced 3-T MRI. The degree of myometrial invasion was pathologically cl...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0000000000000689

    authors: Sakane M,Hori M,Onishi H,Tsuboyama T,Ota T,Tatsumi M,Ueda Y,Kimura T,Kimura T,Tomiyama N

    更新日期:2018-05-01 00:00:00

  • Quantification of mitral regurgitation on cardiac computed tomography: comparison with qualitative and quantitative echocardiographic parameters.

    abstract:PURPOSE:To assess whether cardiac computed tomographic angiography (CCTA) can quantify the severity of chronic mitral regurgitation (MR) compared to qualitative and quantitative echocardiographic parameters. MATERIALS AND METHODS:Cardiac computed tomographic angiography was performed in 23 patients (mean ± SD age, 63 ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0b013e31822d28b8

    authors: Arnous S,Killeen RP,Martos R,Quinn M,McDonald K,Dodd JD

    更新日期:2011-09-01 00:00:00

  • Value of magnetic resonance imaging for muscle denervation syndromes of the shoulder girdle.

    abstract::Clinical evaluation of neuromuscular disorders typically consists of obtaining a detailed clinical history, physical examination, and electrophysiologic examinations. Electrodiagnostic examinations significantly aid in distinguishing between myopathy, neuropathy, and neuromuscular disorders. Electrodiagnostic examinat...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/01.rct.0000161929.88730.15

    authors: Elsayes KM,Shariff A,Staveteig PT,Mukundan G,Khosla A,Rubin DA

    更新日期:2005-05-01 00:00:00

  • Intravoxel Incoherent Motion Diffusion-Weighted Magnetic Resonance Imaging of Cervical Cancer With Different b-Values.

    abstract:OBJECTIVE:The aims of this study were to evaluate the dependence of diffusion parameters on the b values adopted for intravoxel incoherent motion diffusion-weighted magnetic resonance imaging and to investigate the application value of multiple diffusion parameters obtained from monoexponential and biexponential models...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0000000000000569

    authors: Wu Q,Wang Y,Shi L,Dong L,Liu M,Dou S,Zhu S,Wang M,Shi D

    更新日期:2017-07-01 00:00:00

  • Infiltrating angiolipoma of skeletal muscle: MR findings.

    abstract::Infiltrating angiolipoma of skeletal muscle is a rare benign tumor that has a tendency to recur unless completely excised. Although CT and angiography have been used to determine its extent, they will not allow a definite diagnosis. We present magnetic resonance findings and assert that an accurate preoperative diagno...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198807000-00037

    authors: Bolen JW Jr,de Lange EE,Frierson HF Jr

    更新日期:1988-07-01 00:00:00

  • MRI of unfused lumbar segments after spondylodesis.

    abstract:PURPOSE:Our goal was to find a causal relation between disk degeneration in nonfused lumbar segments, back pain, and the angle of scoliotic curves 21-30 years after dorsal spondylodesis. METHOD:Thirty-two patients with scoliosis had been treated by dorsal spondylodesis 21-30 years prior to this study (mean 25.2 +/- 2....

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-199607000-00015

    authors: Breitenseher MJ,Eyb RP,Matzner MP,Trattnig S,Kainberger FM,Imhof H

    更新日期:1996-07-01 00:00:00

  • CT for assessing feasibility of separation of thoracopagus twins.

    abstract::The value of the angio-computed tomography technique for evaluating communication between cardiac cavities of the two hearts in conjoined twins is reported. After injecting contrast medium into the peripheral vein of one of the twins, the increase in density values of the heart in the other twin suggested shunting bet...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198108000-00023

    authors: Rossi P,Cozzi F,Iannaccone G

    更新日期:1981-08-01 00:00:00

  • Preoperative Coil Embolization in Patients With a Replaced Hepatic Artery Scheduled for Pancreatectomy With Splanchnic Artery Resection Helps to Prevent Ischemic Organ Injury.

    abstract:OBJECTIVE:The aim of this study was to evaluate the prevention of liver ischemic injury by preoperative coil embolization in patients with a replaced hepatic artery scheduled for pancreatectomy with splanchnic artery resection. METHODS:Between July 2009 and May 2012, 4 patients with replaced hepatic artery underwent p...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0000000000000325

    authors: Ishikawa M,Yamagami T,Kakizawa H,Hieda M,Toyota N,Fukumoto W,Kajiwara K,Yoshimatsu R,Sudo T,Murakami Y,Awai K

    更新日期:2016-01-01 00:00:00

  • Two- and three-dimensional phase contrast MR angiography of the abdomen.

    abstract::Protocols for two- and three-dimensional phase contrast magnetic resonance angiography of the major vessels in the abdomen were developed and demonstrated in healthy volunteers. Phase contrast imaging provides excellent suppression of stationary tissue signal and can be used to quantify the speed and direction of flow...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-199009000-00020

    authors: Dumoulin CL,Yucel EK,Vock P,Souza SP,Terrier F,Steinberg FL,Wegmuller H

    更新日期:1990-09-01 00:00:00

  • Splenic peliosis mimicking a solid tumor: findings in multimodalities.

    abstract::A splenic mass was found in an asymptomatic 76-year-old woman who had been treated with steroids for autoimmune hepatitis. The lesion was found to be hyperechoic on ultrasound examination, hypovascular on angiography, low attenuating on postcontrast computed tomography, isointense to splenic parenchyma on precontrast ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0b013e31815b3ef5

    authors: Abo D,Terae S,Fukasawa Y,Seki H,Hasegawa Y,Sakuhara Y,Shimizu T,Shirato H

    更新日期:2008-11-01 00:00:00

  • Ossifying fibroma of sphenoid bone with coexistent mucocele: CT and MRI.

    abstract::A case of a 26-year-old woman with decreasing vision in her right eye, diplopia, headache, and galactorrhea is presented. Both CT and MR studies showed a large sphenoid fibroosseous lesion that had a ground glass appearance on CT and low-to-intermediate proton density and low T2-weighted and low T1-weighted signal int...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-199305000-00032

    authors: Sterling KM,Stollman A,Sacher M,Som PM

    更新日期:1993-05-01 00:00:00

  • Leigh disease (subacute necrotizing encephalomyelopathy): CT and MR in five cases.

    abstract::Magnetic resonance (MR) imaging and CT were used in supporting the diagnosis of Leigh disease (subacute necrotizing encephalomyelopathy) in five patients. Two cases were confirmed at postmortem examination, and three patients have laboratory and/or clinical histories suggestive of Leigh disease. Four cases demonstrate...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198801000-00006

    authors: Geyer CA,Sartor KJ,Prensky AJ,Abramson CL,Hodges FJ,Gado MH

    更新日期:1988-01-01 00:00:00

  • Erosion of the scapula by a benign lipoma: computed tomography diagnosis.

    abstract::A lipoma eroding the scapula is diagnosed by computed tomography. ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-197910000-00018

    authors: Lloyd TV,Paul DJ

    更新日期:1979-10-01 00:00:00

  • Multidetector-row computed tomography angiography in abdominal aortic aneurysm treated with endovascular repair: evaluation of optimal timing of delayed phase imaging for the detection of low-flow endoleaks.

    abstract:PURPOSE:To evaluate the optimal timing of delayed phase imaging for detecting low-flow endoleaks. MATERIALS AND METHODS:Fifty-eight patients with unruptured abdominal aortic aneurysm treated with endovascular repair underwent 1- and 6-month follow-up multidetector row computed tomography (CT) performed during unenhanc...

    journal_title:Journal of computer assisted tomography

    pub_type: 临床试验,杂志文章

    doi:10.1097/RCT.0b013e31814b271d

    authors: Iezzi R,Cotroneo AR,Filippone A,Santoro M,Basilico R,Storto ML

    更新日期:2008-07-01 00:00:00

  • T1 lung cancer on CT: frequency of extrathoracic metastases.

    abstract:PURPOSE:To determine the frequency of extrathoracic metastases in T1 non-small-cell lung cancer. METHOD:Ninety patients with T1 lung cancer identified on CT were included. Extrathoracic metastases were evaluated at the time of initial diagnosis and during a 1-year follow-up study. The frequency of metastases was compa...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-200009000-00008

    authors: Jung KJ,Lee KS,Kim H,Kwon OJ,Kim J,Shim YM,Kim TS

    更新日期:2000-09-01 00:00:00