Congested deep subcortical veins as a sign of dural venous thrombosis: MR and CT correlations.

Abstract:

:Dural venous thrombosis can have a rapidly progressive fatal course if unrecognized; its clinical picture is often confusing. Numerous CT, magnetic resonance (MR), and angiographic findings have been described to help recognize this entity. We present a case of dilated transcerebral medullary veins as a sign of superior satittal sinus thrombosis with CT and MR correlation.

journal_name

J Comput Assist Tomogr

authors

Anderson SC,Shah CP,Murtagh FR

doi

10.1097/00004728-198711000-00028

subject

Has Abstract

pub_date

1987-11-01 00:00:00

pages

1059-61

issue

6

eissn

0363-8715

issn

1532-3145

journal_volume

11

pub_type

杂志文章
  • Automated segmentation method for spinal column based on a dual elliptic column model and its application for virtual spinal straightening.

    abstract::Segmentation of vertebral bones in computed tomographic data is important as a first stage of image-based radiological tasks. However, it is a challenging problem to segment an affected spine correctly. In this study, we propose a new method of segmentation of thoracic and lumbar vertebral bodies from thin-slice compu...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0b013e3181b12242

    authors: Hanaoka S,Nomura Y,Nemoto M,Masutani Y,Maeda E,Yoshikawa T,Hayashi N,Yoshioka N,Ohtomo K

    更新日期:2010-01-01 00:00:00

  • Accurate determination of metabolic rates from dynamic positron emission tomography data with very-low temporal resolution.

    abstract:PURPOSE:The graphical approach is widely used for the pixelwise determination of local metabolic rate of glucose from dynamic positron emission tomography (PET) data. In its conventional implementation, measured integrals over time frames are used to approximate instantaneous tracer concentrations at midframe times ("m...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-200307000-00026

    authors: Buchert R,van den Hoff J,Mester J

    更新日期:2003-07-01 00:00:00

  • Usefulness of combining sequentially acquired gadobenate dimeglumine-enhanced magnetic resonance imaging and resovist-enhanced magnetic resonance imaging for the detection of hepatocellular carcinoma: comparison with computed tomography hepatic arteriogra

    abstract:OBJECTIVE:To investigate the diagnostic efficacy of sequentially acquired gadobenete dimeglumine-enhanced 3-dimensional dynamic magnetic resonance imaging (MRI) and Resovist-enhanced MRI for detecting hepatocellular carcinoma (HCC) by comparing with combined computed tomography (CT) hepatic arteriography (CTHA) and CT ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0b013e31802d0b6b

    authors: Kim YK,Kwak HS,Han YM,Kim CS

    更新日期:2007-09-01 00:00:00

  • Anomalous systemic arterialization to normal basal segments of the left lower lobe: helical CT and CTA findings.

    abstract:PURPOSE:The purpose of this work was to evaluate the helical CT and CT angiography (CTA) findings of anomalous systemic artery (ASA) to the basal segments of the left lower lobe (LLL). METHOD:Three patients (two had hemoptysis, one was asymptomatic) with blotchy nodular density in the LLL revealed on chest radiographs...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-200011000-00026

    authors: Ko SF,Ng SH,Lee TY,Wan YL,Lee CM,Hsieh MJ,Chen MC

    更新日期:2000-11-01 00:00:00

  • Three-dimensional flow characteristics in aortic coarctation and poststenotic dilatation.

    abstract::The authors present findings from a scientific study in a 36-year-old male patient who was transferred for the evaluation of a restenosis in aortic coarctation that was initially treated by surgical repair. Contrast-enhanced magnetic resonance angiography and comprehensive flow-sensitive 4-dimensional magnetic resonan...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0b013e3181906766

    authors: Markl M,Arnold R,Hirtler D,von Zur Muhlen C,Harloff A,Langer M,Hennig J,Frydrychowicz A

    更新日期:2009-09-01 00:00:00

  • Partial duplication of the hypophysis in adult patients: report of 2 cases.

    abstract::Complete duplication of the pituitary gland is an extremely rare condition which is associated with a wide range of anomalies. An incomplete duplication affecting only the anterior pituitary gland or the pituitary stalk has not been described so far. We report 2 such cases of partial duplication of the hypophysis and ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/01.rct.0000243458.08061.f1

    authors: Kandpal H,Seith A,Philip J,Gupta R,Ammini AC

    更新日期:2007-05-01 00:00:00

  • The effect of the section thickness used for 2- and 3-dimensional quantification of dual-energy perfusion computed tomography.

    abstract:PURPOSE:To retrospectively investigate the effect of the section thickness used for quantifying dual-energy perfusion computed tomography (DEpCT) during 2- and 3-dimensional evaluation. METHODS:Sixty-six patients (22 males and 44 females; mean age, 59.3 years) suspected of having an acute pulmonary embolism underwent ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0000000000000148

    authors: Nomura T,Okada M,Nakashima Y,Yonezawa T,Kudomi S,Kido S,Matsunaga N

    更新日期:2014-11-01 00:00:00

  • Effect of lower tube voltage on the reproducibility of right-to-left ventricular diameter ratio measurements on computed tomographic pulmonary angiography images.

    abstract:OBJECTIVE:This study aimed to evaluate the interobserver variability of right-to-left ventricular (RV/LV) diameter ratios on computed tomographic pulmonary angiographies at reduced tube potential. METHODS:Consecutive computed tomographic pulmonary angiographies performed at 80 kVp for subjects weighing less than 80 kg...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0b013e3182994f37

    authors: George E,Hunsaker AR,Rybicki FJ,Kumamaru KK

    更新日期:2013-09-01 00:00:00

  • Role of Cardiac Computed Tomography in the Evaluation of Coronary Artery Stenosis in Patients With Ascending Aorta Aneurysm Detected at Transthoracic Echocardiography.

    abstract:OBJECTIVE:The aim of our study was to evaluate the diagnostic performance of cardiac computed tomography (CCT) in the evaluation of coronary artery stenosis in patients with ascending aorta aneurysm detected at transthoracic echocardiography. METHODS:We conducted a retrospective analysis of patients with an aneurysm 4...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0000000000000380

    authors: La Grutta L,Toia P,Galia M,Grassedonio E,Ajello D,Novo G,Bartolotta TV,Maffei E,Novo S,Cademartiri F,Lagalla R,Midiri M

    更新日期:2016-05-01 00:00:00

  • CT diagnosis of dorsal pancreas agenesis.

    abstract::We report a case of agenesis of dorsal pancreas diagnosed by CT. This anomaly can easily be confused with pancreas divisum on endoscopic retrograde cholangiopancreatography alone. ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198701000-00038

    authors: Shah KK,DeRidder PH,Schwab RE,Alexander TJ

    更新日期:1987-01-01 00:00:00

  • Vascular encasement by pancreatic cancer: correlation of CT findings with surgical and pathologic results.

    abstract:PURPOSE:The purpose of this study was to correlate thin-slice high-resolution helical CT findings of arterial and venous involvement in pancreatic cancers with surgical and histopathologic results. METHOD:Forty-eight patients with pancreatic cancer underwent preoperative thin-slice high-resolution helical CT, followed...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-200105000-00002

    authors: Nakayama Y,Yamashita Y,Kadota M,Takahashi M,Kanemitsu K,Hiraoka T,Hirota M,Ogawa M,Takeya M

    更新日期:2001-05-01 00:00:00

  • Intradural spinal metastases in pediatric patients with primary intracranial neoplasms: Gd-DTPA enhanced MR vs CT myelography.

    abstract::Recently, the application of intravenous gadolinium-diethylenetriamine pentaacetic acid (Gd-DTPA) has been shown to improve the detection of intradural extramedullary spinal disease in adults. The ability of Gd-DTPA enhanced magnetic resonance (MR) to detect intradural extramedullary spinal metastases was studied in p...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-199009000-00009

    authors: Blews DE,Wang H,Kumar AJ,Robb PA,Phillips PC,Bryan RN

    更新日期:1990-09-01 00:00:00

  • Angiographic computed tomography is comparable to multislice computed tomography in lumbar myelographic imaging.

    abstract::We evaluated the feasibility of angiographic computed tomography (ACT) for diagnostic imaging in a patient with degenerative lumbar spine disease. ACT provides a volume data set out of a rotational acquisition with a c-arm-mounted flat-panel detector. Using this technique, radiographic myelography and myelographic com...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/01.rct.0000228152.73528.54

    authors: Buhk JH,Elolf E,Knauth M

    更新日期:2006-09-01 00:00:00

  • Benign or malignant?: differentiating breast lesions with computed tomography attenuation values on dynamic computed tomography mammography.

    abstract:OBJECTIVE:To evaluate enhancement effects of breast lesions with dynamic computed tomography (CT) and to determine characteristics to aid in differential diagnosis of benign and malignant lesions. METHODS:One hundred seventy-six women underwent preoperative dynamic CT, in which they were scanned with rapid injection o...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/01.rct.0000178712.32547.53

    authors: Miyake K,Hayakawa K,Nishino M,Nakamura Y,Morimoto T,Urata Y,Ueda H,Tanikake M,Kanao S,Shiozaki T,Yamamoto A

    更新日期:2005-11-01 00:00:00

  • Solid renal mass in the cancer patient: second primary renal cell carcinoma versus renal metastasis.

    abstract::Most renal metastases are asymptomatic, occur with widespread metastatic disease, and are too small to be detected with computed tomography (CT). Rarely they form large masses. These are typically angiographically hypovascular and show only minimal CT contrast enhancement. Renal carcinoma as a second primary malignanc...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198306000-00011

    authors: Pagani JJ

    更新日期:1983-06-01 00:00:00

  • Computed Tomography Assessment of Ablation Zone Enhancement in Patients With Early-Stage Lung Cancer After Stereotactic Ablative Radiotherapy.

    abstract:INTRODUCTION:Stereotactic ablative radiotherapy (SABR) offers a curative treatment for lung cancer in patients who are marginal surgical candidates. However, unlike traditional surgery the lung cancer remains in place after treatment. Thus, imaging follow-up for evaluation of recurrence is of paramount importance. MAT...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0000000000000262

    authors: Moore W,Chaya Y,Chaudhry A,Depasquale B,Glass S,Lee S,Shin J,Mikhail G,Bhattacharji P,Kim B,Bilfinger T

    更新日期:2015-09-01 00:00:00

  • Imaging characteristics of hyperfunctioning parathyroid adenomas using multiphase multidectector computed tomography: a quantitative and qualitative approach.

    abstract:OBJECTIVE:The objective of the study was to characterize the enhancement pattern of hyperfunctioning parathyroid adenomas on multiphase multidetector computed tomography (CT) or 4-dimensional CT. METHODS:We retrospectively studied the enhancement patterns of 48 pathologically confirmed parathyroid adenomas with 4-dime...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0b013e31822a1e70

    authors: Vu TH,Guha-Thakurta N,Harrell RK,Ahmed S,Kumar AJ,Johnson VE,Perrier ND,Hamberg LM,Hunter GJ,Schellingerhout D

    更新日期:2011-09-01 00:00:00

  • Assessment of Myometrial Invasion in Premenopausal Grade 1 Endometrial Carcinoma: Is Magnetic Resonance Imaging a Reliable Tool in Selecting Patients for Fertility-Preserving Therapy?

    abstract:OBJECTIVES:The aim of this study was to evaluate the diagnostic ability of magnetic resonance imaging (MRI) in premenopausal women with G1 endometrial carcinoma. METHODS:Twenty-six patients underwent T2W, diffusion weighted, and dynamic contrast-enhanced 3-T MRI. The degree of myometrial invasion was pathologically cl...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0000000000000689

    authors: Sakane M,Hori M,Onishi H,Tsuboyama T,Ota T,Tatsumi M,Ueda Y,Kimura T,Kimura T,Tomiyama N

    更新日期:2018-05-01 00:00:00

  • Transient subsegmental hepatic parenchymal enhancement on dynamic CT: a sign of postbiopsy arterioportal shunt.

    abstract:PURPOSE:Our goal was to verify the correlation between the arterioportal shunt caused by liver biopsy injury and wedge-shaped early transient subsegmental parenchymal enhancement (TSPE) of the liver during helical dynamic CT. METHOD:Twenty-one consecutive patients with suspected hepatic tumor underwent percutaneous ne...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-199705000-00004

    authors: Lee SJ,Lim JH,Lee WJ,Lim HK,Choo SW,Choo IW

    更新日期:1997-05-01 00:00:00

  • Case report: cushing disease caused by an ectopic intracavernous pituitary microadenoma: case report and review of the literature.

    abstract::Despite increasing performance of pituitary imaging, adrenocorticotropic hormone (ACTH)-secreting pituitary adenomas are often difficult to identify because of their small size and variable location. We present a case of ACTH-dependent Cushing syndrome in which the demonstration of the cavernous sinus localization of ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章,评审

    doi:10.1097/00004728-200305000-00021

    authors: Hamon M,Coffin C,Courthéoux P,Théron J,Reznik Y

    更新日期:2003-05-01 00:00:00

  • Two benign CT presentations of thyroid-related papillary adenocarcinoma.

    abstract::Two cases of thyroid-related papillary adenocarcinoma are presented. Both patients had clinically benign neck masses that were clearly separated from the thyroid gland. In both cases the thyroid gland was normal to clinical evaluation, CT, and 99mTc scanning. One patient had an occult thyroid carcinoma with a solitary...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198501000-00027

    authors: Som PM,Sacher M,Lanzieri CF,Shugar JM,Biller HF

    更新日期:1985-01-01 00:00:00

  • Minor ossicular anomalies in the middle ear: role of submillimeter multislice computed tomography.

    abstract:OBJECTIVE:The objective was to elucidate clinical effectiveness of submillimeter multislice 2- and 3-dimensional computed tomography (CT) for diagnosis of congenital middle ear anomaly. MATERIALS AND METHODS:Preoperative CT and operative findings were retrospectively analyzed in 36 ears of 33 patients. The distance be...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0000000000000093

    authors: Nakasato T,Nakayama T,Nakayama M,Ehara S,Ohtsuka H,Sato H

    更新日期:2014-09-01 00:00:00

  • Value of dynamic enhanced magnetic resonance imaging for distinguishing between ovarian fibroma and subserous uterine leiomyoma.

    abstract:PURPOSE:The purpose of this study was to assess the accuracy of magnetic resonance imaging (MRI), particularly, dynamic MRI, in distinguishing ovarian fibromas from subserous uterine leiomyomas. MATERIAL AND METHODS:Fifteen ovarian fibromas and 15 subserous uterine leiomyomas were retrospectively reviewed. All MR exam...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/01.rct.0000237810.88251.9e

    authors: Thomassin-Naggara I,Daraï E,Nassar-Slaba J,Cortez A,Marsault C,Bazot M

    更新日期:2007-03-01 00:00:00

  • CT findings in hepatic involvement by Echinococcus granulosus.

    abstract::The CT findings in hepatic involvement by Echinococcus granulosus are described. Pathognomonic signs of the hydatid nature of a cystic lesion are visualization of the cystic wall on plain CT, calcification of the cyst wall, daughter cysts, and membrane detachment. ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198410000-00005

    authors: Pandolfo I,Blandino G,Scribano E,Longo M,Certo A,Chirico G

    更新日期:1984-10-01 00:00:00

  • Organ-based computed tomographic (CT) radiation dose reduction to the lenses: impact on image quality for CT of the head.

    abstract:PURPOSE:Recently, a new specific organ dose adaption and reduction protocol, or SODAR tool (X-CARE, Siemens Healthcare), which reduces dose to the anterior aspect of the body of patients, was installed on our computed tomographic scanner. The purpose of this pilot project was to evaluate image quality and dose distribu...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0b013e318251ec61

    authors: Reimann AJ,Davison C,Bjarnason T,Thakur Y,Kryzmyk K,Mayo J,Nicolaou S

    更新日期:2012-05-01 00:00:00

  • Comparison of 320-row computed tomography coronary angiography with conventional angiography for the assessment of coronary artery disease with different atherosclerotic plaque characteristics.

    abstract:OBJECTIVE:The objective of this study was to compare the accuracy of 320-row computed tomography angiography (CTA) with conventional coronary angiography. METHODS:Two hundred seventy-four patients with coronary artery disease who received both invasive coronary angiography and 320-row CTA were included. Stenosis of 50...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0b013e31826ab24a

    authors: Yang QH,Chen YJ,Liu QQ,Dong M,Wen L,Song X,Lv YJ,Gong YZ,Li XQ

    更新日期:2012-11-01 00:00:00

  • Evaluation of elastic matching system for anatomic (CT, MR) and functional (PET) cerebral images.

    abstract::To evaluate the performance of our elastic matching system, we have created a digitized atlas from the brain of a normal young man, using 135 myelin-stained sections at 700 microns spacing. Software was written to enter and edit regional anatomic contours, which were stacked and aligned to create a three-dimensional a...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198907000-00009

    authors: Dann R,Hoford J,Kovacic S,Reivich M,Bajcsy R

    更新日期:1989-07-01 00:00:00

  • Physiological Laterality of Superficial Cerebral Veins on Susceptibility-Weighted Imaging.

    abstract:OBJECTIVE:The purpose of this study is to evaluate whether laterality of the superficial cerebral veins can be seen on susceptibility-weighted imaging (SWI) in patients with no intracranial lesions that affect venous visualization. METHODS:We retrospectively evaluated 386 patients who underwent brain magnetic resonanc...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0000000000000637

    authors: Matsushima S,Shimizu T,Gomi T,Fukuda K

    更新日期:2018-01-01 00:00:00

  • Application and Indication of Carcinoembryonic Antigen Triggered 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography Scanning in the Detection of Relapse of Colorectal Cancer Patients After Curative Therapy.

    abstract:OBJECTIVE:This study aimed to explore the characteristics of patients with colorectal cancer (CRC) following curative therapy that may benefit from fluorine-18-2-uoro-2-deoxy-D-glucose positron emission tomography/computed tomography (F-FDG PET/CT) scanning, evaluate the application of carcinoembryonic antigen (CEA)-tr...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0000000000000601

    authors: Yu X,Zhu L,Dai D,Song X,Chen W,Zhu Y,Li X,Xu W

    更新日期:2017-09-01 00:00:00

  • In vivo 19F NMR imaging of the cardiovascular system.

    abstract::A technique is described that permits the 19F nuclear magnetic resonance (NMR) imaging of the vascular system in animals that have been infused with certain perfluorocarbon blood substitutes. The essence of the technique is the selection for imaging of a narrow group of spectral lines from the fluorocarbon using a com...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198511000-00003

    authors: Joseph PM,Fishman JE,Mukherji B,Sloviter HA

    更新日期:1985-11-01 00:00:00