Wideband middle ear power measurement in infants and children.

Abstract:

:Wideband middle ear power (WMEP) measurement is a method of middle ear analysis that may provide improved diagnostic capability over single-frequency tympanometry. However, normative data, information about test-retest reliability, and results in clinical disorders are needed for clinical application. Normative and reliability data on WMEP in children three days to 47 months of age were obtained using a prototype commercial instrument. A prospective study was conducted in children enrolled from a well-child pediatric clinic (n = 97), with comparisons of age, gender, and middle ear status and stimulus type (broadband chirp and sine wave). No significant age effect for power reflectance across the age range of this study was found, except at 6000 Hz. Significantly higher-power reflectance was found for ears with poor ear status, specifically otitis media with effusion. Smaller but nonsignificant differences in power reflectance were found for ears with positive and negative tympanometric peak pressure. Intraclass correlation coefficients showed significant correlations of 0.68 to 0.97 at various test frequencies using the chirp stimulus. Multivariate analysis of variance showed no significant effect of stimulus type (sine wave vs broadband chirp), ear, or gender. These results provide normative data for wideband middle ear power analysis for infants and children from birth to age four years.

journal_name

J Am Acad Audiol

authors

Hunter LL,Tubaugh L,Jackson A,Propes S

doi

10.3766/jaaa.19.4.4

subject

Has Abstract

pub_date

2008-04-01 00:00:00

pages

309-24

issue

4

eissn

1050-0545

issn

2157-3107

journal_volume

19

pub_type

临床试验,杂志文章
  • Development of hearing. Part III. Postnatal development.

    abstract::As humans, we hear the way we do because of at least three major forces. The first is phylogeny, the evolutionary changes in the auditory system since its beginnings. The second is embryology, the formation of the system in each individual. Finally, there is the interaction between the biologically determined mechanis...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,评审

    doi:

    authors: Peck JE

    更新日期:1995-03-01 00:00:00

  • Cognitive factors in auditory performance: context, speed of processing, and constraints of memory.

    abstract::This paper describes several techniques used to explore the role of cognitive factors in auditory performance in elderly adults. Two factors, cognitive slowing and age-related memory constraints, receive special attention. Assessing listeners' ability to report the content of time-compressed speech shows elderly adult...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Wingfield A

    更新日期:1996-06-01 00:00:00

  • Central deafness associated with a midbrain lesion.

    abstract::Central deafness has been linked historically to bihemispheric involvement of the temporal lobe, with more recent findings suggesting that compromise of other cortical and subcortical structures can also result in this disorder. The present investigation extends our understanding of the potential anatomical correlates...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.15.2.4

    authors: Musiek FE,Charette L,Morse D,Baran JA

    更新日期:2004-02-01 00:00:00

  • An attempt to improve bilateral cochlear implants by increasing the distance between electrodes and providing complementary information to the two ears.

    abstract:OBJECTIVES:The purpose of this investigation was to determine if adult bilateral cochlear implant recipients could benefit from using a speech processing strategy in which the input spectrum was interleaved among electrodes across the two implants. DESIGN:Two separate experiments were conducted. In both experiments, s...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.21.1.7

    authors: Tyler RS,Witt SA,Dunn CC,Perreau A,Parkinson AJ,Wilson BS

    更新日期:2010-01-01 00:00:00

  • One-year vestibular and balance outcomes of Oklahoma City bombing survivors.

    abstract::This multisite investigation assessed subjective, behavioral, and objective balance function in 30 blast survivors. Subjects with vertigo, dizziness, or imbalance were screened (n = 6) or evaluated (n = 27) during 1 year. Tests included a questionnaire, electronystagmography (ENG), and computerized dynamic posturograp...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Van Campen LE,Dennis JM,King SB,Hanlin RC,Velderman AM

    更新日期:1999-10-01 00:00:00

  • Evaluating performance with high-frequency emphasis amplification.

    abstract::Hearing aid fitting for individuals with high-frequency impairment has been difficult because of the limited gain available at those frequencies. Special high-frequency emphasis hearing aids have been developed in an attempt to alleviate this problem. The insertion-gain responses and changes in speech-recognition perf...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Lee LW,Humes LE,Wilde G

    更新日期:1993-03-01 00:00:00

  • Intertester reliability of the acceptable noise level.

    abstract:BACKGROUND:The acceptable noise level (ANL) serves to accurately predict the listener's likelihood of success with amplification. It has been proposed as a pre-hearing aid fitting protocol for hearing aid selection and counseling purposes. The ANL is a subjective measure of the listener's ability to accept background n...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 临床试验,杂志文章

    doi:10.3766/jaaa.23.7.5

    authors: Gordon-Hickey S,Adams E,Moore R,Gaal A,Berry K,Brock S

    更新日期:2012-07-01 00:00:00

  • Normal multiple auditory steady-state response thresholds to air-conducted stimuli in infants.

    abstract:BACKGROUND AND PURPOSE:Multiple auditory steady-state responses (ASSRs) to stimuli modulated at approximately 80 Hz are a promising technique for threshold estimation in infants, but additional data are required. RESEARCH DESIGN:We obtained multiple ASSRs to air-conducted (AC) stimuli. STUDY SAMPLE:There were 54 chil...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.20.3.6

    authors: Van Maanen A,Stapells DR

    更新日期:2009-03-01 00:00:00

  • Probe-microphone measurements with body-worn instruments: loudspeaker and reference microphone effects.

    abstract::Probe-microphone measurements are typically made with behind-the-ear (BTE) and in-the-ear (ITE) hearing aids with the loudspeaker located at 0-degrees or 45-degrees azimuth at head level and the reference microphone positioned on the head near the hearing aid microphone. With body-worn instruments, these conditions ma...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Nelson JA,Hawkins DB

    更新日期:1994-03-01 00:00:00

  • Cochlear implant microphone location affects speech recognition in diffuse noise.

    abstract:BACKGROUND:Despite improvements in cochlear implants (CIs), CI recipients continue to experience significant communicative difficulty in background noise. Many potential solutions have been proposed to help increase signal-to-noise ratio in noisy environments, including signal processing and external accessories. To da...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.26.1.6

    authors: Kolberg ER,Sheffield SW,Davis TJ,Sunderhaus LW,Gifford RH

    更新日期:2015-01-01 00:00:00

  • The Benefit of Remote Microphones Using Four Wireless Protocols.

    abstract:BACKGROUND:Many studies have reported the speech recognition benefits of a personal remote microphone system when used by adult listeners with hearing loss. The advance of wireless technology has allowed for many wireless audio transmission protocols. Some of these protocols interface with commercially available hearin...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,随机对照试验

    doi:10.3766/jaaa.15008

    authors: Rodemerk KS,Galster JA

    更新日期:2015-09-01 00:00:00

  • Prediction and statistical evaluation of speech recognition test scores.

    abstract::A speech test evaluation and presentation system is described. The test presentation subsystem has the flexibility and speed of live-voice testing while using recorded test materials. The speech test evaluation subsystem compares an individual subject's test performance on a monosyllabic word test with that of an aver...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Studebaker GA,Gray GA,Branch WE

    更新日期:1999-07-01 00:00:00

  • Effects of pre-existing hearing loss and gender on proposed ANSI S12.13 outcomes for characterizing hearing conservation program effectiveness: preliminary investigation.

    abstract::Draft American National Standard "Evaluating the Effectiveness of Hearing Conservation Programs" identifies potentially important links between audiometric threshold variability outcomes and occupational hearing conservation program (HCP) practices. Unacceptable threshold variability in annual audiograms may identify ...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Amos NE,Simpson TH

    更新日期:1995-11-01 00:00:00

  • Multiple-ASSR thresholds in infants and young children with hearing loss.

    abstract:BACKGROUND:The multiple auditory steady-state response (multiple ASSR) is a promising technique for determining thresholds for infants and children. However, there are few data for infants and young children with hearing loss where multiple-ASSR thresholds have been compared to frequency-specific gold standard (i.e., b...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.21.8.5

    authors: Van Maanen A,Stapells DR

    更新日期:2010-09-01 00:00:00

  • Implications of audiologic success.

    abstract::In the last few years, a clinical consensus has emerged regarding the necessary components of an early management program for hearing-impaired children. Early detection of hearing loss, a parent-infant and supervised nursery program, and optimal amplification provisions are among these components. This paper explores ...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Ross M

    更新日期:1992-01-01 00:00:00

  • Personal amplification for school-age children with auditory processing disorders.

    abstract:BACKGROUND:Children with auditory processing disorders (APD) are described to have a signal-to-noise ratio (SNR) difficulty. Frequency-modulated (FM) systems have been reported to improve this situation. Yet the use of personal amplification that may be more portable has not been attempted. PURPOSE:To determine whethe...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.19.6.3

    authors: Kuk F,Jackson A,Keenan D,Lau CC

    更新日期:2008-06-01 00:00:00

  • Considerations for cochlear implantation of children with sudden, fluctuating hearing loss.

    abstract::The histories of two pediatric patients who received cochlear implants with subsequent partial recovery of hearing in the nonimplanted ear are reviewed. One child had a sudden bilateral hearing loss, presumably secondary to autoimmune ear disease. The other child had a bilateral progressive hearing loss diagnosed as l...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.16.10.2

    authors: Sweetow RW,Rosbe KW,Philliposian C,Miller MT

    更新日期:2005-11-01 00:00:00

  • Connected Audiological Rehabilitation: 21st Century Innovations.

    abstract:BACKGROUND:Tele-audiology provides a means to offer audiologic rehabilitation (AR) in a cost-, resource-, and time-effective manner. If designed appropriately, it also has the capability of personalizing rehabilitation to the user in terms of content, depth of detail, etc., thus permitting selection of the best content...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,评审

    doi:10.3766/jaaa.14062

    authors: Saunders GH,Chisolm TH

    更新日期:2015-10-01 00:00:00

  • A Comparison of Word-Recognition Performances on the Auditec and VA Recorded Versions of Northwestern University Auditory Test No. 6 by Young Listeners with Normal Hearing and by Older Listeners with Sensorineural Hearing Loss Using a Randomized Presentat

    abstract:BACKGROUND:The Auditec of St. Louis and the Department of Veterans Affairs (VA) recorded versions of the Northwestern University Auditory Test No. 6 (NU-6) are in common usage. Data on young adults with normal hearing for pure tones (YNH) demonstrate equal recognition performances on the two versions when the VA versio...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,随机对照试验

    doi:10.3766/jaaa.17135

    authors: Wilson RH

    更新日期:2019-05-01 00:00:00

  • Effects of release time and directionality on unilateral and bilateral hearing aid fittings in complex sound fields.

    abstract::In studies to date, the effectiveness of the directional microphone has been investigated independently of the signal processing scheme used in the hearing aid. In addition, the number and placement of the background noise speakers can create an advantage for a particular polar pattern (i.e., cardioid, supercardioid, ...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Novick ML,Bentler RA,Dittberner A,Flamme GA

    更新日期:2001-11-01 00:00:00

  • Differences and intersubject variability of loudness discomfort levels measured in sound pressure level and hearing level for TDH-50P and ER-3A earphones.

    abstract::Loudness discomfort levels (LDLs) were measured in dB HL and SPL at discrete frequencies between 500 to 4000 Hz on 31 hearing-impaired ears using TDH-50P and ER-3A earphones. The results revealed no significant differences in the measured sound pressure level (SPL) between the two earphones at all test frequencies. Ho...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Valente M,Potts LG,Valente M

    更新日期:1997-02-01 00:00:00

  • Historic perspective of the acoustic otoscope.

    abstract::The acoustic otoscope, originally called the acoustic reflectometer, was developed and produced by John and David Teele in the early 1980s. Since initial production, two different instrument versions have been developed by two separate companies. During the period of time in which the acoustic otoscope has been in pro...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 历史文章,杂志文章

    doi:

    authors: Walsh FP,Cox LC,MacDonald CB

    更新日期:1998-02-01 00:00:00

  • An Evaluation of Motivational Interviewing for Increasing Hearing Aid Use: A Pilot Study.

    abstract:BACKGROUND:Motivational interviewing (MI) has been used in consultation settings to motivate hearing aid users to increase hearing aid usage. However, the effect of MI on those who use their hearing aids only rarely or not at all has not been explored. PURPOSE:The aims of this pilot study were to evaluate the effect o...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.16184

    authors: Solheim J,Gay C,Lerdal A,Hickson L,Kvaerner KJ

    更新日期:2018-09-01 00:00:00

  • Hearing loss in Stickler's syndrome: a family case study.

    abstract::Stickler's syndrome is an autosomal dominant hereditary condition that presents with pathognomonic facial features, dysplasia, myopia and auditory deficits. This paper describes the auditory history of a family with Stickler's syndrome. Given the expressive variability, a complete audiologic and otologic evaluation is...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Jacobson J,Jacobson C,Gibson W

    更新日期:1990-01-01 00:00:00

  • Patient preferences and willingness to pay for tinnitus treatments.

    abstract:PURPOSE:There will likely be several different tinnitus treatments necessary, and it is important to understand patient preferences and factors that might contribute to treatment acceptability. This study explores the acceptability of a wide range of different tinnitus treatments, from noninvasive wearable devices to s...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.23.2.6

    authors: Tyler RS

    更新日期:2012-02-01 00:00:00

  • Auditory brainstem response testing in neurodiagnosis: structure versus function.

    abstract::This case report describes a 44-yr-old female referred by an outside facility who presented with progressive hearing loss in her left ear. Magnetic resonance imaging (MRI) results were normal, but a battery of audiological tests suggested neural hearing loss in the left ear. Following diagnosis of left neural hearing ...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.23.4.5

    authors: Peterein JL,Neely JG

    更新日期:2012-04-01 00:00:00

  • Effects of open-set and closed-set task demands on spoken word recognition.

    abstract::Closed-set tests of spoken word recognition are frequently used in clinical settings to assess the speech discrimination skills of hearing-impaired listeners, particularly children. Speech scientists have reported robust effects of lexical competition and talker variability in open-set tasks but not closed-set tasks, ...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,随机对照试验

    doi:10.3766/jaaa.17.5.4

    authors: Clopper CG,Pisoni DB,Tierney AT

    更新日期:2006-05-01 00:00:00

  • A comparison of gain for adults from generic hearing aid prescriptive methods: impacts on predicted loudness, frequency bandwidth, and speech intelligibility.

    abstract:BACKGROUND:Prescriptive methods have been at the core of modern hearing aid fittings for the past several decades. Every decade or so, there have been revisions to existing methods and/or the emergence of new methods that become widely used. In 2001 Byrne et al provided a comparison of insertion gain for generic prescr...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.22.7.5

    authors: Johnson EE,Dillon H

    更新日期:2011-07-01 00:00:00

  • Evaluation of a BICROS System with a Directional Microphone in the Receiver and Transmitter.

    abstract:BACKGROUND:The bilateral contralateral routing of signals (BICROS) system has provided limited benefit for speech recognition in noise for patients with asymmetric sensorineural hearing loss, even when an automatic adaptive multichannel directional microphone (DM) is in the receiver (Rx) and an omnidirectional micropho...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,随机对照试验

    doi:10.3766/jaaa.15031

    authors: Valente M,Oeding K

    更新日期:2015-11-01 00:00:00

  • Intersubject variability of real-ear sound pressure level: conventional and insert earphones.

    abstract::Measures of the sound pressure level (SPL) near the eardrum were determined at discrete frequencies between 500 and 4000 Hz on 50 ears using TDH-39P and ER-3A earphones with the attenuator of an audiometer fixed at 90 dB HL. Results revealed significant differences in the measured SPL between the two earphones at all ...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Valente M,Potts LG,Valente M,Vass W,Goebel J

    更新日期:1994-11-01 00:00:00