Abstract:
:In an effort to reveal the possible underlying causes of radiation-related health care complaints in the State of Texas, complaint data were evaluated using historical Texas Department of Health-Bureau of Radiation Control (TDH-BRC) reports. A major aim of the study was to generate a summary of the most commonly reported complaints that might be generalized to health care providers using sources of radiation across Texas. A generalizable list of common complaints would be a valuable tool for education and prevention programs, serving to possibly reduce the overall incidence of radiation-related medical complaints. Descriptive text summary reports of complaints were obtained from the TDH-BRC for the 20-y period inclusive of 1981 to 2001. The information was systematically coded into a computerized database. During the 20-y period of study, 481 health care-related complaints were identified, with approximately 74% consisting of claims of an "uncredentialed technician" (39%), "overexposure" (21%), or "regulatory violation" (14%). The most common categories of complaints imply some patient understanding or knowledge of the credentialing requirements of workers, the applicable dose limits, or the regulatory requirements associated with medical procedures. Since it is unlikely that an average patient would be aware of such issues, the findings suggest the complaints are not actually indications of the inappropriate uses of radiation, but are rather based on the patient's broader perception of services rendered. Most of the complaints levied during the period of study were done so anonymously (58%) and were levied against a generic facility (61%) rather than a specific technician (5%), doctor (4%), or student (1%). Approximately 61% of the complaints resulted in the issuance of a notice of violation upon investigation by the TDH-BRC, but the available data did not permit definitive linkage between the initial complaint and the violation issued. Taken in aggregate, the analysis suggests that improved communications between health care providers and the patients they serve could possibly serve to prevent future complaints. Although the analysis was limited to the data from a single state, the results may be of use to quality assurance programs on a broader scale because of the objective identification of likely common issues. Possible options for improving the means of systematically collecting initial compliant data in the future are also discussed.
journal_name
Health Physjournal_title
Health physicsauthors
Thommen PJ,Emery RJdoi
10.1097/01.HP.0000202231.88465.6asubject
Has Abstractpub_date
2006-05-01 00:00:00pages
S62-6issue
5 Suppleissn
0017-9078issn
1538-5159pii
00004032-200605002-00006journal_volume
90pub_type
杂志文章相关文献
HEALTH PHYSICS文献大全abstract::Past computer solutions for confidence intervals in paired counting are extended to the case where the ratio of the sample count time to the blank count time is taken to be an integer, IRR. Previously, confidence intervals have been named Neyman-Pearson confidence intervals; more correctly they should have been named ...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/HP.0b013e31820448c4
更新日期:2011-05-01 00:00:00
abstract::Sandia National Laboratories' Z-Machine is the world's most powerful electrical device, and experiments have been conducted that make it the world's most powerful radiation source. Because Z-Machine is used for research, an assortment of materials can be placed into the machine; these materials can be subjected to a r...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/HP.0b013e31827126f1
更新日期:2013-02-01 00:00:00
abstract::The data presented show early results from a longitudinal survey of "therapeutic" ultrasonic instrument performance in clinical physiotherapy. Previous studies undertaken in North America and the United Kingdom have shown that these units tend not to be scientifically tested and recalibrated, and have been found to ha...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/00004032-198209000-00007
更新日期:1982-09-01 00:00:00
abstract::RESRAD-RECYCLE is a computer code designed by Argonne National Laboratory (ANL) to be used in making decisions about the disposition of radioactively contaminated materials and scrap metals. It implements a pathway analysis methodology to evaluate potential radiation exposures resulting from the recycling of contamina...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/01.hp.0000133367.21270.3e
更新日期:2004-11-01 00:00:00
abstract::A new modification of the prior human lung compartment plutonium model, Doses-2005, has been described. The modified model was named "Mayak Worker Dosimetry System-2008" (MWDS-2008). In contrast to earlier models developed for workers at the Mayak Production Association (Mayak PA), the new model more correctly describ...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/HP.0b013e31827dbf60
更新日期:2013-04-01 00:00:00
abstract::Design and associated good practices are described for a modular glovebox connector to improve control of radioactive and chemically toxic materials. The connector consists of an anodized aluminum circular port with a mating spacer, gaskets, and retaining rings for joining two parallel ends of commercially available o...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/00004032-199901000-00011
更新日期:1999-01-01 00:00:00
abstract::The first cycle of statewide radionuclide concentration measurements of public drinking water supplies was completed in accord with the Federal and Georgia Safe Drinking Water Acts. The recommended pattern of analysis is initial screening for gross alpha-particle activity, followed by measuring 226Ra if the gross alph...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/00004032-198301000-00001
更新日期:1983-01-01 00:00:00
abstract::Correlations are studied between average radon levels in 1600 U.S. counties and mortality rates in them from various types of cancer. By far the strongest correlation is with lung cancer, but the sign of the correlation is negative. When smoking prevalence is included in a multiple regression, the large negative corre...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/00004032-199311000-00009
更新日期:1993-11-01 00:00:00
abstract::The Marshall Islands were the site of numerous tests of nuclear weapons by the United States. From 1946 to 1958, nuclear devices were detonated at Enewetak and Bikini Atolls. Following the inadvertent contamination of the northern islands downwind of the 1954 Bravo Test, Brookhaven National Laboratory became involved ...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/00004032-199707000-00007
更新日期:1997-07-01 00:00:00
abstract::Since the mid-1940s, hundreds of thousands of workers have been engaged in nuclear weapons-related activities for the U.S. Department of Energy (DOE) and its predecessor agencies. In 2000, Congress promulgated the Energy Employees Occupational Illness Compensation Program Act of 2000 (EEOICPA), which provides monetary...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/HP.0000000000000008
更新日期:2014-02-01 00:00:00
abstract::Monte Carlo simulation techniques using a Monte Carlo N-Particle code (MCNP5) analyzed six Source Production & Equipment Co., Inc., Se industrial radiography sources to determine an appropriate air kerma rate constant for Se, factoring in source encapsulation and compared to a theoretical approximation. Based on this ...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/HP.0b013e318284592c
更新日期:2013-05-01 00:00:00
abstract::The International Commission on Radiological Protection system of radiological protection is based on three pillars: science, ethical and social values, and experience. As far as ethics and the protection of humans are concerned, the system combines the values of beneficence/non-maleficence, prudence, justice, and dig...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/HP.0000000000000438
更新日期:2016-02-01 00:00:00
abstract::Thermoluminescent detectors (TLDs) can provide accurate and precise measurements for both patient and personnel dosimetry in the medical imaging environment. They have the advantages of tissue equivalency, an excellent dynamic range, and dose rate independence. In the work reported here, experiments with planar x-ray,...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/00004032-199012000-00006
更新日期:1990-12-01 00:00:00
abstract::Following a radiation emergency, evacuated, sheltered or other members of the public would require monitoring for external and/or internal contamination and, if indicated, decontamination. In addition, the potentially-impacted population would be identified for biodosimetry/bioassay or needed medical treatment (chelat...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/HP.0b013e31821dd9a2
更新日期:2011-08-01 00:00:00
abstract::The novel technique for measuring the water content in lungs based on the slowing down of fast neutrons has been improved making possible its clinical use on patients. This goal has been reached by performing computer simulations that closely mimic the experimental setup and by acquiring a new set of measurements obta...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/00004032-200112000-00022
更新日期:2001-12-01 00:00:00
abstract::Considering that in 1899 neither biotechnology nor the electronic revolution were foreseen, some humility might be advisable when one looks into the crystal ball for the future role of radiation sources. In the past 50 years, nuclear medicine, nuclear weapons, and nuclear power have had a huge impact in the world. In ...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/00004032-200104000-00008
更新日期:2001-04-01 00:00:00
abstract::This review summarizes the current state of research on possible health effects of Wi-Fi (a commercial name for IEEE 802.11-compliant wireless networking). In response to public concerns about health effects of Wi-Fi and wireless networks and calls by government agencies for research on possible health and safety issu...
journal_title:Health physics
pub_type: 杂志文章,评审
doi:10.1097/HP.0b013e31829b49bb
更新日期:2013-12-01 00:00:00
abstract::Radiofrequency-induced hyperthermia has recently gained acceptance in cancer therapy. One of a few commercially available systems is the Magnetrode, a device operating at 13.56 MHz with an output power up to 1000 W. Heating of the prescribed part of the patient's body is accomplished by one of the coil electrodes. To ...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/00004032-198307000-00010
更新日期:1983-07-01 00:00:00
abstract::This paper examines in humans the proposition emanating from studies in beagles that initial retention of radium varies in proportion to the calcium addition rate at the time of intake. Human calcium addition rates were scaled from those in beagles, the relative calcium accretion rates in the two species at equivalent...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/00004032-198306001-00008
更新日期:1983-01-01 00:00:00
abstract::A comparison of the risk coefficients for 239Pu- or 226Ra-induced bone cancer in two canine breeds, one with a relatively low (beagle) and the other with a very high (St. Bernard) natural incidence, indicated only slightly higher risk in the giant breed. The differences in risk for skeletal malignancy in 239Pu and 226...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/00004032-199710000-00014
更新日期:1997-10-01 00:00:00
abstract::After a nuclear attack it may be necessary for emergency workers, such as firemen, utility workers and medical personnel, to perform urgent tasks in areas highly contaminated by radioactive fallout. To assist the control of radiation exposure of these workers, it will be useful to provide means to forecast radiation e...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/00004032-198606000-00002
更新日期:1986-06-01 00:00:00
abstract::Beagle dogs were given subcutaneous implants of plutonium in their forepaws to mimic hand wounds received by workers accidentally contaminated with plutonium. Ten dogs received 9.46 +/- 0.43 mu Ci of plutonium oxide, and eight dogs received 1.25 +/- 0.60 mu Ci of plutonium nitrate. Surviving dogs were sacrificed at 8 ...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/00004032-198407000-00006
更新日期:1984-07-01 00:00:00
abstract::Studies of the physical and chemical properties of radioactive aerosols produced in different work environments were made at Chin-Shan nuclear power plant in Taiwan. These properties, including particle mass- and activity-size distributions, elemental and radionuclide compositions, and solubility lung class, are essen...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/00004032-199308000-00003
更新日期:1993-08-01 00:00:00
abstract::The evaluation of the dose rate distributions from radioactive sources, together with the specific detector locations with respect to those sources, in many cases presents a significant analytical challenge. With the exception of a few, simple source-detector geometries, it is not possible to find an analytical expres...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/HP.0b013e3182295943
更新日期:2011-11-01 00:00:00
abstract::Facing the challenge from terrorism, separatism, and extremism, China spared no effort to be prepared for every possible threat in order to host a safe Olympic Games. According to its statutory role, the Ministry of Health (MOH) is in charge of medical preparedness and response for radiological and nuclear emergencies...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/HP.0b013e3181b182dc
更新日期:2010-06-01 00:00:00
abstract::In conventional radiation-therapy facilities, radiation doses to medical personnel originate from the leakage radiation of 60Co teletherapy systems or from photoneutrons produced during the operation of x-ray generators at energies over 10 MeV in unsuitably shielded therapy rooms. In neutron-therapy facilities, during...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/00004032-198402000-00016
更新日期:1984-02-01 00:00:00
abstract::A rugged resin concentration method followed by gamma counting was developed for measuring 226Ra and 228Ra in drinking water. Using typical distribution system pressure, 310 kPa (45 psig), radium in a 20-L sample was concentrated 100-fold onto 200 mL of ion-exchange resin beads that were then sealed in a glass jar for...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/00004032-199205000-00005
更新日期:1992-05-01 00:00:00
abstract::A dosimetry system for computed tomography (CT) examinations, named WAZA-ARI, is being developed to accurately assess radiation doses to patients in Japan. For dose calculations in WAZA-ARI, organ doses were numerically analyzed using average adult Japanese male (JM) and female (JF) phantoms with the Particle and Heav...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/HP.0000000000000299
更新日期:2015-08-01 00:00:00
abstract::The objectives of this research were (1) to analyze the transfers of 137Cs and 60Co in a retention pond, with emphasis on aquatic insects and (2) to determine if detectable concentrations of these radionuclides are exported by emerging aquatic insects. We analyzed the radionuclide concentrations in the following compo...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/00004032-198511000-00010
更新日期:1985-11-01 00:00:00
abstract::This paper provides information on the effects of distance and attenuation in lead sheet and gypsum board of the 0.511 MeV photon produced by positron annihilation. Exposure rates are projected external to an adult injected with 185 MBq (5 mCi) of 18F in a fluorodeoxyglucose solution and for the same activity in a sma...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/00004032-200108001-00012
更新日期:2001-08-01 00:00:00