Abstract:
OBJECTIVE:To study the effects of reduced lighting on the gait of older adults with a high level gait disorder (HLGD) and to compare their response to that of healthy elderly controls. METHODS:22 patients with a HLGD and 20 age-matched healthy controls were studied under usual lighting conditions (1000 lumens) and in near darkness (5 lumens). Gait speed and gait dynamics were measured under both conditions. Cognitive function, co-morbidities, depressive symptoms, and vision were also evaluated. RESULTS:Under usual lighting conditions, patients walked more slowly, with reduced swing times, and increased stride-to-stride variability, compared to controls. When walking under near darkness conditions, both groups slowed their gait. All other measures of gait were not affected by lighting in the controls. In contrast, patients further reduced their swing times and increased their stride-to-stride variability, both stride time variability and swing time variability. The unique response of the patients was not explained by vision, mental status, co-morbidities, or the values of walking under usual lighting conditions. CONCLUSION:Walking with reduced lighting does not affect the gait of healthy elderly subjects, except for a reduction in speed. On the other hand, the gait of older adults with a HLGD becomes more variable and unsteady when they walk in near darkness, despite adapting a slow and cautious gait. Further work is needed to identify the causes of the maladaptive response among patients with a HLGD and the potential connection between this behavior and the increased fall risk observed in these patients.
journal_name
J Neuroeng Rehabiljournal_title
Journal of neuroengineering and rehabilitationauthors
Kesler A,Leibovich G,Herman T,Gruendlinger L,Giladi N,Hausdorff JMdoi
10.1186/1743-0003-2-27subject
Has Abstractpub_date
2005-08-28 00:00:00pages
27issn
1743-0003pii
1743-0003-2-27journal_volume
2pub_type
杂志文章abstract:BACKGROUND:Support for rehabilitation research at the National Institutes of Health (NIH) is robust and evolving. Since the time of its Blue Ribbon Panel on Rehabilitation Research, NIH has participated in several initiatives to coordinate the science and advance the field. DISCUSSION:Collaborative teams must continue...
journal_title:Journal of neuroengineering and rehabilitation
pub_type: 信件
doi:10.1186/s12984-020-00696-0
更新日期:2020-05-29 00:00:00
abstract:BACKGROUND:Uneven ground is a frequently encountered, yet little-studied challenge for individuals with amputation. The absence of control at the prosthetic ankle to facilitate correction for surface inconsistencies, and diminished sensory input from the extremity, add unpredictability to an already complex control pro...
journal_title:Journal of neuroengineering and rehabilitation
pub_type: 杂志文章
doi:10.1186/s12984-019-0497-9
更新日期:2019-02-04 00:00:00
abstract:BACKGROUND:We present a closed-loop system able to control the frequency of slow oscillations (SO) spontaneously generated by the cortical network in vitro. The frequency of SO can be controlled by direct current (DC) electric fields within a certain range. Here we set out to design a system that would be able to auton...
journal_title:Journal of neuroengineering and rehabilitation
pub_type: 杂志文章
doi:10.1186/s12984-018-0470-z
更新日期:2019-01-09 00:00:00
abstract::Exoskeleton technology has made significant advances during the last decade, resulting in a considerable variety of solutions for gait assistance and rehabilitation. The mechanical design of these devices is a crucial aspect that affects the efficiency and effectiveness of their interaction with the user. Recent devel...
journal_title:Journal of neuroengineering and rehabilitation
pub_type: 杂志文章,评审
doi:10.1186/s12984-019-0517-9
更新日期:2019-05-09 00:00:00
abstract:BACKGROUND:Mobile health monitoring using wearable sensors is a growing area of interest. As the world's population ages and locomotor capabilities decrease, the ability to report on a person's mobility activities outside a hospital setting becomes a valuable tool for clinical decision-making and evaluating healthcare ...
journal_title:Journal of neuroengineering and rehabilitation
pub_type: 杂志文章
doi:10.1186/s12984-016-0114-0
更新日期:2016-01-20 00:00:00
abstract:BACKGROUND:There is a paucity of information regarding visuospatial (VS) and visuomotor (VM) task performance in patients with chronic right fronto-parietal lobe stroke, as the majority of knowledge to date in this realm has been gleaned from acute stroke patients. The goal of this paper is to determine how VS and VM p...
journal_title:Journal of neuroengineering and rehabilitation
pub_type: 杂志文章
doi:10.1186/1743-0003-10-20
更新日期:2013-02-13 00:00:00
abstract:BACKGROUND:The aim of this study was to quantitatively analyze quite standing postural stability of adolescent idiopathic scoliosis (AIS) patients in respect to three sensory systems (visual, vestibular, and somatosensory). METHOD:In this study, we analyzed the anterior-posterior center of pressure (CoP) signal using ...
journal_title:Journal of neuroengineering and rehabilitation
pub_type: 杂志文章
doi:10.1186/s12984-018-0395-6
更新日期:2018-06-22 00:00:00
abstract:BACKGROUND:There is an increasing trend in using robots for medical purposes. One specific area is rehabilitation. Rehabilitation is one of the non-drug treatments in community health which means the restoration of the abilities to maximize independence. It is a prolonged work and costly labor. On the other hand, by us...
journal_title:Journal of neuroengineering and rehabilitation
pub_type: 杂志文章
doi:10.1186/1743-0003-10-96
更新日期:2013-08-14 00:00:00
abstract:BACKGROUND:Powered exoskeletons are a promising approach to restore the ability to walk after spinal cord injury (SCI). However, current exoskeletons remain limited in their walking speed and ability to support tasks of daily living, such as stair climbing or overcoming ramps. Moreover, training progress for such advan...
journal_title:Journal of neuroengineering and rehabilitation
pub_type: 杂志文章
doi:10.1186/s12984-018-0360-4
更新日期:2018-03-13 00:00:00
abstract:BACKGROUND:The limited range of motion during walking in children with spastic cerebral palsy (SCP) may be the result of altered mechanical characteristics of muscles and connective tissues around the knee joint. Measurement of static net knee moment-angle relation will provide insights into these alterations, for whic...
journal_title:Journal of neuroengineering and rehabilitation
pub_type: 杂志文章
doi:10.1186/s12984-015-0056-y
更新日期:2015-08-15 00:00:00
abstract::The study of gait variability, the stride-to-stride fluctuations in walking, offers a complementary way of quantifying locomotion and its changes with aging and disease as well as a means of monitoring the effects of therapeutic interventions and rehabilitation. Previous work has suggested that measures of gait variab...
journal_title:Journal of neuroengineering and rehabilitation
pub_type: 杂志文章
doi:10.1186/1743-0003-2-19
更新日期:2005-07-20 00:00:00
abstract:BACKGROUND:To promote early rehabilitation of walking, gait training can start even when patients are on bed rest. Supine stepping in the early phase after injury is proposed to maximise the beneficial effects of gait restoration. In this training paradigm, mechanical loading on the sole of the foot is required to mimi...
journal_title:Journal of neuroengineering and rehabilitation
pub_type: 杂志文章
doi:10.1186/1743-0003-11-159
更新日期:2014-11-28 00:00:00
abstract:BACKGROUND:For high usability, myo-controlled devices require robust classification schemes during dynamic contractions. Therefore, this study investigates the impact of the training data set in the performance of several pattern recognition algorithms during dynamic contractions. METHODS:A 9 class experiment was desi...
journal_title:Journal of neuroengineering and rehabilitation
pub_type: 杂志文章
doi:10.1186/1743-0003-8-25
更新日期:2011-05-09 00:00:00
abstract:BACKGROUND:Textile-based transducers are an emerging technology in which piezo-resistive properties of materials are used to measure an applied strain. By incorporating these sensors into a sock, this technology offers the potential to detect critical events during the stance phase of the gait cycle. This could prove u...
journal_title:Journal of neuroengineering and rehabilitation
pub_type: 杂志文章
doi:10.1186/1743-0003-8-32
更新日期:2011-05-27 00:00:00
abstract:BACKGROUND:Many gait impairments are characterized by asymmetry and result in reduced mobility. Exoskeletons could be useful for restoring gait symmetry by assisting only one leg. However, we still have limited understanding of the effects of unilateral exoskeleton assistance. Our aim was to compare the effects of unil...
journal_title:Journal of neuroengineering and rehabilitation
pub_type: 杂志文章
doi:10.1186/s12984-018-0381-z
更新日期:2018-08-09 00:00:00
abstract:BACKGROUND:Powered exoskeleton can improve the mobility for people with movement deficits by providing mechanical support and facilitate the gait training. This pilot study evaluated the effect of gait training using a newly developed powered lower limb exoskeleton robot for individuals with complete spinal cord injury...
journal_title:Journal of neuroengineering and rehabilitation
pub_type: 杂志文章
doi:10.1186/s12984-018-0355-1
更新日期:2018-03-05 00:00:00
abstract:BACKGROUND:Motor planning, imagery or execution is associated with event-related desynchronization (ERD) of mu rhythm oscillations (8-13 Hz) recordable over sensorimotor areas using electroencephalography (EEG). It was shown that motor imagery involving distal muscles, e.g. finger movements, results in contralateral ER...
journal_title:Journal of neuroengineering and rehabilitation
pub_type: 杂志文章
doi:10.1186/s12984-017-0294-2
更新日期:2017-08-25 00:00:00
abstract:BACKGROUND:Walking in daily life is complex entailing various prerequisites such as leg strength, trunk stability or cognitive and motor dual task (DT) activities. Conventional physiotherapy can be complemented with robot-assisted gait therapy (RAGT) and exergames to enhance the number of step repetitions, feedback, mo...
journal_title:Journal of neuroengineering and rehabilitation
pub_type: 临床试验,杂志文章
doi:10.1186/s12984-018-0426-3
更新日期:2018-09-17 00:00:00
abstract:BACKGROUND:Computer-based cognitive stimulation applications can help the elderly maintain and improve their cognitive skills. In this research paper, our objectives are to verify the usability of PESCO (an open-software application for cognitive evaluation and stimulation) and to determine the concurrent validity of c...
journal_title:Journal of neuroengineering and rehabilitation
pub_type: 临床试验,杂志文章
doi:10.1186/1743-0003-11-88
更新日期:2014-05-15 00:00:00
abstract:BACKGROUND:Virtual Reality provides new options for conducting motor assessment and training within computer-generated 3 dimensional environments. To date very little has been reported about normal performance in virtual environments. The objective of this study was to evaluate the test-retest reliability of a clinical...
journal_title:Journal of neuroengineering and rehabilitation
pub_type: 杂志文章
doi:10.1186/1743-0003-4-13
更新日期:2007-05-09 00:00:00
abstract:BACKGROUND:People with a lower-extremity amputation that use conventional passive-elastic ankle-foot prostheses encounter a series of stress-related challenges during walking such as greater forces on their unaffected leg, and may thus be predisposed to secondary musculoskeletal injuries such as chronic joint disorders...
journal_title:Journal of neuroengineering and rehabilitation
pub_type: 杂志文章
doi:10.1186/1743-0003-10-49
更新日期:2013-06-07 00:00:00
abstract:BACKGROUND:Add-on robot-mediated therapy has proven to be more effective than conventional therapy alone in post-stroke gait rehabilitation. Such robot-mediated interventions routinely use also visual biofeedback tools. A better understanding of biofeedback content effects when used for robotic locomotor training may i...
journal_title:Journal of neuroengineering and rehabilitation
pub_type: 杂志文章,随机对照试验
doi:10.1186/s12984-019-0558-0
更新日期:2019-07-23 00:00:00
abstract:BACKGROUND:Vibrotactile stimulation is a promising venue in the field of prosthetics to retrain sensory feedback deficits following amputation. Discrimination is well established at the forearm level but not at the upper arm level. Moreover, the effects of combining vibration characteristics such as duration and intens...
journal_title:Journal of neuroengineering and rehabilitation
pub_type: 杂志文章
doi:10.1186/s12984-019-0597-6
更新日期:2019-11-13 00:00:00
abstract:BACKGROUND:Previous studies have assessed the effects of perturbation training on balance after stroke. However, the perturbations were either applied while standing or were small in amplitude during gait, which is not representative of the most common fall conditions. The perturbations were also combined with other ch...
journal_title:Journal of neuroengineering and rehabilitation
pub_type: 杂志文章,随机对照试验
doi:10.1186/s12984-020-00707-0
更新日期:2020-06-17 00:00:00
abstract:BACKGROUND:Activities of daily living frequently require children to make rapid decisions and execute desired motor actions while inhibiting unwanted actions. Children with hemiparetic cerebral palsy due to perinatal stroke may have deficits in executive functioning in addition to motor impairments. The objective of th...
journal_title:Journal of neuroengineering and rehabilitation
pub_type: 杂志文章
doi:10.1186/s12984-020-00714-1
更新日期:2020-07-14 00:00:00
abstract:BACKGROUND:Cerebellar symptoms are extremely disabling and are common in Multiple Sclerosis (MS) subjects. In this feasibility study, we developed and tested a robot therapy protocol, aimed at the rehabilitation of incoordination in MS subjects. METHODS:Eight subjects with clinically defined MS performed planar reachi...
journal_title:Journal of neuroengineering and rehabilitation
pub_type: 杂志文章,随机对照试验
doi:10.1186/1743-0003-7-37
更新日期:2010-07-29 00:00:00
abstract:BACKGROUND:Recent studies have shown that neural stimulation can be used to provide artificial sensory feedback to amputees eliciting sensations referred on the amputated hand. The temporal properties of the neural stimulation modulate aspects of evoked sensations that can be exploited in a bidirectional hand prosthesi...
journal_title:Journal of neuroengineering and rehabilitation
pub_type: 杂志文章
doi:10.1186/s12984-020-00737-8
更新日期:2020-08-15 00:00:00
abstract:BACKGROUND:Brain-computer interfaces (BCIs) have demonstrated the potential to provide paralyzed individuals with new means of communication, but an electroencephalography (EEG)-based endogenous BCI has never been successfully used for communication with a patient in a completely locked-in state (CLIS). METHODS:In thi...
journal_title:Journal of neuroengineering and rehabilitation
pub_type: 杂志文章
doi:10.1186/s12984-019-0493-0
更新日期:2019-01-30 00:00:00
abstract:BACKGROUND:Many contemporary systems for neurorehabilitation utilize 3D virtual environments (VEs) that allow for training patients' hand or arm movements. In the current paper we comparatively test the effectiveness of two characteristics of VEs in rehabilitation training when utilizing a 3D haptic interaction device:...
journal_title:Journal of neuroengineering and rehabilitation
pub_type: 杂志文章
doi:10.1186/1743-0003-9-73
更新日期:2012-10-05 00:00:00
abstract:BACKGROUND:Task-specific perturbation training is a widely studied means of fall prevention, utilizing techniques that induce slips or slip-like perturbations during gait. Though effective, these methods only simulate narrow ranges within the larger space of possible slipping conditions encountered in daily life. Here ...
journal_title:Journal of neuroengineering and rehabilitation
pub_type: 杂志文章
doi:10.1186/s12984-019-0602-0
更新日期:2019-10-17 00:00:00