Endothelial damage caused by uncoated and fluorocarbon-coated poly(methyl methacrylate) intraocular lenses.

Abstract:

PURPOSE:To assess endothelial damage induced by poly(methyl methacrylate) (PMMA) intraocular lenses (IOLs) coated with a fluorocarbon polymer, Teflon AF, to make them highly hydrophobic. SETTING:Department of Ophthalmology. Hôtel-Dieu Hospital, Paris, France. METHODS:Ten Teflon-coated and 10 uncoated PMMA IOLs were used in an in vitro static touch model. The corneal endothelium was placed in direct contact with the IOL for 15 seconds and then stained with trypan blue and alizarin red. The endothelial damage produced by each IOL in the area of contact was assessed semiquantitatively and quantitatively. RESULTS:Teflon-coated IOLs produced significantly less endothelial damage than uncoated PMMA IOLs (P < .0001). Endothelial cells in contact with Teflon-coated IOLs did not usually adhere to the IOL surface. In contrast, the uncoated IOLs produced large areas of endothelial cell loss. CONCLUSION:Teflon-coated PMMA IOLs have an antiadhesive effect that reduced endothelial damage after IOL insertion in an in vitro model.

authors

Werner LP,Legeais JM,Durand J,Savoldelli M,Legeay G,Renard G

doi

10.1016/s0886-3350(97)80073-9

subject

Has Abstract

pub_date

1997-09-01 00:00:00

pages

1013-9

issue

7

eissn

0886-3350

issn

1873-4502

pii

S0886-3350(97)80073-9

journal_volume

23

pub_type

杂志文章
  • Fungal keratitis after laser in situ keratomileusis.

    abstract::A 22-year-old woman presented with pain, redness, watering, and decrease in vision in her left eye 15 days after laser in situ keratomileusis for myopia. Slitlamp examination showed a central full-thickness infiltrate with hyphate edges. Microscopic examination of corneal scrapings from the edge and underneath the fla...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(99)00459-9

    authors: Sridhar MS,Garg P,Bansal AK,Sharma S

    更新日期:2000-04-01 00:00:00

  • Incidence of diffuse lamellar keratitis after LASIK with 15 KHz, 30 KHz, and 60 KHz femtosecond laser flap creation.

    abstract:PURPOSE:To compare the incidence of diffuse lamellar keratitis (DLK) after laser in situ keratomileusis (LASIK) with flap creation using the 15 kHz (FS15), 30 kHz (FS30), or 60 kHz (FS60) femtosecond laser. SETTING:University-based academic practice, Ann Arbor, Michigan, USA. DESIGN:Retrospective comparative case ser...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2010.09.003

    authors: Choe CH,Guss C,Musch DC,Niziol LM,Shtein RM

    更新日期:2010-11-01 00:00:00

  • Combined penetrating keratoplasty and implantation of iris prosthesis intraocular lenses after ocular trauma.

    abstract:PURPOSE:To report the outcomes of implantation of intraocular lenses (IOLs) with a prosthetic iris to correct traumatic iris deficiency. SETTING:Department of Ophthalmology, Toronto Western Hospital, University Health Network, Toronto, Ontario, Canada. DESIGN:Case series. METHODS:The medical records of consecutive p...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2010.10.038

    authors: Mashor RS,Bahar I,Kaiserman I,Berg AL,Slomovic A,Rootman DS

    更新日期:2011-03-01 00:00:00

  • Laser flap enhancement 5 to 9 years and 10 or more years after laser in situ keratomileusis: Safety and efficacy.

    abstract:PURPOSE:To study the safety and efficacy of refractive enhancement by flap lifting 5 and 10 years after laser in situ keratomileusis (LASIK). SETTING:Vissum Alicante, Spain. DESIGN:Retrospective case series. METHODS:Eyes with a flap lift at least 5 years after primary LASIK with a 3-month follow-up were evaluated. T...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2019.05.030

    authors: Alió Del Barrio JL,Hanna R,Canto-Cerdan M,Vega-Estrada A,Alió JL

    更新日期:2019-10-01 00:00:00

  • Comparison of corneal astigmatism measurements of 2 optical biometer models for toric intraocular lens selection.

    abstract:PURPOSE:To compare corneal astigmatism measurements obtained using a new optical biometer (AL-Scan) and a standard biometer based on partial coherence interferometry (IOLMaster 500) for toric intraocular lens (IOL) selection. SETTING:Siriraj Hospital, Mahidol University, Bangkok, Thailand. DESIGN:Prospective comparat...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2014.06.029

    authors: Srivannaboon S,Chirapapaisan C,Chonpimai P,Koodkaew S

    更新日期:2015-02-01 00:00:00

  • Surgical options in the face of positive pressure.

    abstract::Positive pressure during cataract surgery can adversely affect the clinical outcome if the surgeon is unprepared. A variety of surgical maneuvers are described, including dry insertion of the phacoemulsification needle, capsule protection with the second instrument, dry cortical aspiration in an ophthalmic viscosurgic...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2006.06.011

    authors: Khng C,Osher RH

    更新日期:2006-09-01 00:00:00

  • Effectiveness of 4 tonometers in measuring IOP after femtosecond laser-assisted LASIK, SMILE, and transepithelial photorefractive keratectomy.

    abstract:PURPOSE:To test the performance of 4 tonometers in estimating intraocular pressure (IOP) after 3 forms of refractive surgery. SETTING:Eye Hospital, Wenzhou Medical University, China. DESIGN:Prospective case series. METHODS:Patients matched for preoperative age, corneal thickness, and myopic correction enrolled for f...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1097/j.jcrs.0000000000000204

    authors: Chen S,Lopes BT,Huang W,Zheng X,Wang J,Zhu R,Vinciguerra R,Li Y,Wang Q,Li H,Bao F,Elsheikh A

    更新日期:2020-07-01 00:00:00

  • Preventing expulsive hemorrhage using an anterior chamber maintainer to eliminate hypotony.

    abstract::We describe a method in which constant infusion inflow through an anterior chamber maintainer (ACM) is used to maintain positive intraocular pressure (IOP) during cataract extraction through a self-sealing tunnel incision. A retrospective review of patient records showed that the difference in the incidence of intraop...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(97)80202-7

    authors: Blumenthal M,Grinbaum A,Assia EI

    更新日期:1997-05-01 00:00:00

  • Visual quality and performance comparison between 2 refractive rotationally asymmetric multifocal intraocular lenses.

    abstract:PURPOSE:To compare the 12-month postoperative quality of vision and visual performance of 2 different refractive rotationally asymmetric multifocal intraocular lenses (IOLs). SETTING:Cathedral Eye Clinic, Belfast, Northern Ireland, United Kingdom. DESIGN:Retrospective case series. METHODS:Refractive lens exchange (R...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2017.05.039

    authors: McNeely RN,Pazo E,Spence A,Richoz O,Nesbit MA,Moore TCB,Moore JE

    更新日期:2017-08-01 00:00:00

  • In vitro and schematic model eye assessment of glare or positive dysphotopsia-type photic phenomena: Comparison of a new material IOL to other monofocal IOLs.

    abstract:PURPOSE:To compare the glare-type photic phenomena for a new intraocular lens (IOL) to other monofocal IOLs, and to investigate how IOL design features might affect these phenomena. SETTING:Alcon Laboratories, Inc., Fort Worth, Texas; John A Moran Eye Center, University of Utah, Salt Lake City, USA. DESIGN:Schematic ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2018.09.017

    authors: Das KK,Werner L,Collins S,Hong X

    更新日期:2019-02-01 00:00:00

  • Intraocular lens far peripheral vision: image detail and negative dysphotopsia.

    abstract:PURPOSE:To evaluate negative dysphotopsia in the far periphery of the pseudophakic eye by generating simulated images of text charts. SETTING:Consultancy. DESIGN:Laboratory study. METHODS:Simulated images of a peripheral text chart were created using a ray-trace model of a pseudophakic eye. The point spread function...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1097/j.jcrs.0000000000000103

    authors: Simpson MJ

    更新日期:2020-03-01 00:00:00

  • Combined myopia and astigmatism surgery. Review of 350 cases.

    abstract::Between February 1985 and December 1987, 350 eyes had combined radial keratotomy and transverse keratotomy surgery. All procedures were performed by the same surgeon. The number and length of the radial and transverse incisions were varied according to the surgeon's clinical judgment based on his personal experience a...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(13)80074-0

    authors: Schneider DM,Draghic T,Murthy RK

    更新日期:1992-07-01 00:00:00

  • Anterior segment changes during accommodation in eyes with a monofocal intraocular lens: high-frequency ultrasound study.

    abstract:PURPOSE:To analyze anterior segment structure changes during accommodative stimuli after monofocal intraocular lens (IOL) implantation using 2 ultrasound biomicroscopy (UBM) systems. SETTING:Department of Ophthalmology, University of Verona, Verona, Italy. METHODS:Twenty-six eyes (23 patients) with 1 of 4 monofocal I...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2008.02.018

    authors: Marchini G,Pedrotti E,Modesti M,Visentin S,Tosi R

    更新日期:2008-06-01 00:00:00

  • Comparison of function and fixation of small incision circular and oval poly(methyl methacrylate) intraocular lenses.

    abstract::A prospective study of function and fixation was done on 40 patients implanted with small incision poly(methyl methacrylate), single piece, biconvex intraocular lenses after in situ phacoemulsification cataract extraction via a continuous curvilinear capsulorhexis. A 5.0 mm circular optic (Pharmacia 740 P), 14 mm leng...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(13)80919-4

    authors: Davis PL

    更新日期:1992-03-01 00:00:00

  • Collagen copolymer toric posterior chamber phakic intraocular lens in eyes with keratoconus.

    abstract:PURPOSE:To assess the safety, efficacy, stability, and predictability of collagen copolymer toric phakic intraocular lens (pIOL) implantation to correct myopia and astigmatism in eyes with keratoconus. SETTING:Fernández-Vega Ophthalmological Institute, Oviedo, Spain. METHODS:This prospective study comprised keratocon...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2009.11.032

    authors: Alfonso JF,Fernández-Vega L,Lisa C,Fernandes P,González-Méijome JM,Montés-Micó R

    更新日期:2010-06-01 00:00:00

  • Cell adhesion on explanted intraocular lenses: part 1: analysis of explanted IOLs.

    abstract:PURPOSE:To determine whether cell adhesion on an intraocular lens (IOL) in Japanese patients is affected by the optic material. SETTING:Department of Ophthalmology, Wakayama Medical University, Wakayama, Japan. DESIGN:Experimental study. METHODS:Intraocular lenses of various materials explanted from Japanese patient...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2011.04.001

    authors: Ishikawa N,Miyamoto T,Okada Y,Saika S

    更新日期:2011-07-01 00:00:00

  • Secondary closure of posterior continuous curvilinear capsulorhexis.

    abstract:PURPOSE:To examine the hypothesis that removing the center of the posterior capsule would prevent posterior capsular opacification (PCO). SETTING:Department of Ophthalmology, University Hospital Antwerp, Belgium. METHODS:A posterior continuous curvilinear capsulorhexis (CCC) was done before intraocular lens (IOL) imp...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(96)80068-x

    authors: Tassignon MJ,De Groot V,Smets RM,Tawab B,Vervecken F

    更新日期:1996-11-01 00:00:00

  • Photorefractive keratectomy in keratoconus suspects.

    abstract:PURPOSE:To compare the refractive outcome after photorefractive keratectomy (PRK) in keratoconus-suspect patients with that in patients with normal corneal topography. SETTING:Gimbel Eye Centre, Calgary, Alberta, Canada. METHOD:In a retrospective study, 3 patients (5 eyes) with unusually shaped corneal topography bef...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(99)00234-5

    authors: Sun R,Gimbel HV,Kaye GB

    更新日期:1999-11-01 00:00:00

  • Effect of hinge width on corneal sensation and dry eye after laser in situ keratomileusis.

    abstract:PURPOSE:To investigate the effect of hinge width on corneal sensation and dry-eye syndrome after laser in situ keratomileusis (LASIK). SETTING:TLC Laser Eye Center, Garden City, New York, USA. METHODS:Fifty-four patients at least 18 years of age had bilateral LASIK with a narrow nasal hinge microkeratome flap in 1 ey...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2003.09.043

    authors: Donnenfeld ED,Ehrenhaus M,Solomon R,Mazurek J,Rozell JC,Perry HD

    更新日期:2004-04-01 00:00:00

  • Biomechanical aspects of the anterior capsulotomy.

    abstract::We used the finite element method to evaluate different capsulotomy techniques. Nucleus expression was simulated in a computer model to visualize stress distribution in the anterior capsule. The finite element model demonstrated that the capsulorhexis edge is strong because of low and uniform stress distribution in th...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(13)80176-9

    authors: Krag S,Thim K,Corydon L,Kyster B

    更新日期:1994-07-01 00:00:00

  • Comparison of 2 types of intrastromal corneal ring segments for keratoconus.

    abstract:PURPOSE:To assess the effectiveness and safety of 2 types of 6.0 mm intrastromal corneal ring segments (ICRS) in patients with mild to severe keratoconus. SETTING:Lebanese American University, Beirut, Lebanon. DESIGN:Retrospective comparative case series. METHODS:Eyes had implantation of Intacs SK ICRS (Group 1) or ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2012.02.039

    authors: Haddad W,Fadlallah A,Dirani A,El Rami H,Fahd D,Khanafer D,Fahed S

    更新日期:2012-07-01 00:00:00

  • Comparison of effective phacoemulsification time and corneal endothelial cell loss using 2 ultrasound frequencies.

    abstract:PURPOSE:To compare 2 ultrasound (US) frequencies for phacoemulsification for moderate to hard cataract to determine a frequency that makes phacoemulsification safer and more efficacious. SETTING:Post Graduate Institute of Medical Education and Research, New Delhi, India. DESIGN:Randomized controlled trial. METHODS:P...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.jcrs.2019.04.015

    authors: Dewan T,Malik PK,Kumari R

    更新日期:2019-09-01 00:00:00

  • Posterior capsule opacification and neodymium:YAG laser capsulotomy rates with 2 microincision intraocular lenses: Four-year results.

    abstract:PURPOSE:To compare the development of posterior capsule opacification (PCO) and neodymium:YAG (Nd:YAG) capsulotomy rates between 2 microincision intraocular lenses (IOLs) 4 years after surgery. SETTING:Department of Ophthalmology, Medical University of Vienna, Vienna, Austria. DESIGN:Prospective randomized clinical t...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.jcrs.2014.09.037

    authors: Schriefl SM,Menapace R,Stifter E,Zaruba D,Leydolt C

    更新日期:2015-05-01 00:00:00

  • Visual acuity tolerance to residual refractive errors in patients with an apodized diffractive intraocular lens.

    abstract:PURPOSE:To assess visual acuity tolerance to defocus caused by residual refractive errors after clear lens extraction (CLE) with apodized diffractive intraocular lens (IOL) implantation. SETTING:Fernández-Vega Ophthalmological Institute, Oviedo, Spain. METHODS:In this prospective study, 150 eyes of 75 consecutive pat...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2007.10.020

    authors: Fernández-Vega L,Alfonso JF,Montés-Micó R,Amhaz H

    更新日期:2008-02-01 00:00:00

  • Performance of the 1CU accommodating intraocular lens in relation to capsulorhexis size.

    abstract:PURPOSE:To assess the correlation between continuous curvilinear capsulorhexis (CCC) size and visual outcomes in patients with an accommodating intraocular lens (IOL). SETTING:Heidelberg IOL and Refractive Surgery Research Group, Department of Ophthalmology, Ruprecht-Karls-University of Heidelberg, Heidelberg, Germany...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2004.02.071

    authors: Vargas LG,Auffarth GU,Becker KA,Rabsilber TM,Holzer MP

    更新日期:2005-02-01 00:00:00

  • Feasibility and safety of laser treatments in eyes with an intraocular implantable miniature telescope.

    abstract:PURPOSE:To evaluate the feasibility and safety of laser treatments in rabbit eyes fitted with an implantable miniature telescope (IMT). SETTING:The Goldschleger Eye Research Institute, Tel-Aviv University, Sheba Medical Center, Tel-Hashomer, Israel. METHODS:In this study, IMTs were implanted in the capsular bag in 19...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(02)01647-4

    authors: Rosner M,Ben-Simon G,Sachs D

    更新日期:2003-05-01 00:00:00

  • Gravitational pseudoaccommodation in patients with aphakic iris-claw intraocular lenses.

    abstract:PURPOSE:To assess whether iris-claw intraocular lenses (IOLs) undergo gravitation-dependent changes in position and refraction. SETTING:Tertiary referral center, Bern, Switzerland. DESIGN:Observational case study. METHODS:Patients with a history of pars plana vitrectomy and IOL exchange with implantation of an aphak...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2016.07.033

    authors: Lincke JB,Miller M,Ebneter A,Zinkernagel MS

    更新日期:2016-10-01 00:00:00

  • Radial keratotomy learning curve using the American technique.

    abstract:PURPOSE:To delineate the learning curve for a beginning refractive surgeon using the centrifugal (American) technique. SETTING:Naval Medical Center, San Diego, California, USA. METHODS:The first 100 radial keratotomy (RK) cases (51 patients) of one surgeon, divided into five sequential groups of 20, were retrospectiv...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(98)80286-1

    authors: Blanton CL,Schallhorn SC,Tidwell JL

    更新日期:1998-04-01 00:00:00

  • Functional and anatomical outcomes of vitreoretinal surgery for posterior segment complications after elective cataract surgery.

    abstract:PURPOSE:To assess the outcomes in patients who required 1 or more vitreoretinal interventions for posterior segment complications arising from elective uneventful cataract surgery. SETTING:Tertiary referral center, single-center study. METHODS:A retrospective interventional case series included 56 consecutive patient...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2006.10.034

    authors: Garweg JG,Moser F,Kodjikian L,Halberstadt M

    更新日期:2007-02-01 00:00:00

  • Pseudomonas aeruginosa endophthalmitis caused by contamination of the internal fluid pathways of a phacoemulsifier.

    abstract:PURPOSE:To report 4 cases of Pseudomonas aeruginosa endophthalmitis caused by internal contamination of the internal pathways of a phacoemulsifier. SETTING:Ophthalmology Center, Perpignan, France. METHODS:Four clinical cases of postoperative endophthalmitis occurred after phacoemulsification. An investigation was nec...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(99)80052-2

    authors: Zaluski S,Clayman HM,Karsenti G,Bourzeix S,Tournemire A,Faliu B,Gulian C,Grimont F

    更新日期:1999-04-01 00:00:00