Intra-ocular pressure changes in patients with glaucoma. Comparison between the laryngeal mask airway and tracheal tube.

Abstract:

:We performed a randomised prospective study in 20 patients with glaucoma to examine the effects of tracheal intubation and laryngeal mask insertion on intra-ocular pressure, mean arterial blood pressure and heart rate. After induction of anaesthesia with propofol, intra-ocular pressure decreased significantly below baseline values in both the laryngeal mask and tracheal tube groups. After insertion of the laryngeal mask, intra-ocular pressure remained significantly below baseline values in all patients. In contrast, tracheal intubation was associated with a significant increase in intra-ocular pressure to above baseline values in three out of eight patients. Insertion of the laryngeal mask had minimal effects on mean arterial blood pressure and heart rate, whereas tracheal intubation significantly increased both factors relative to pre-intubation values.

journal_name

Anaesthesia

journal_title

Anaesthesia

authors

Barclay K,Wall T,Wareham K,Asai T

doi

10.1111/j.1365-2044.1994.tb03378.x

subject

Has Abstract

pub_date

1994-02-01 00:00:00

pages

159-62

issue

2

eissn

0003-2409

issn

1365-2044

journal_volume

49

pub_type

临床试验,杂志文章,随机对照试验
  • The effect of the European Working Time Directive on anaesthetic working patterns and training.

    abstract::There is concern that the European Working Time Directive 2009 has led to reduced time available for training, and this study examined if this has been the case. For two identical six-month periods in 1999 (pre-Directive) and 2009 (post-Directive), weekly data were collected on the total number of sessions attended by...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/j.1365-2044.2012.07227.x

    authors: Paul RG,Bunker N,Fauvel NJ,Cox M

    更新日期:2012-09-01 00:00:00

  • Incidence of and risk factors for difficult ventilation via a supraglottic airway device in a population of 14,480 patients from South-East Asia.

    abstract::Difficult airway practice guidelines include the use of a supraglottic airway device as part of the armamentarium to provide and maintain ventilation and oxygenation. We retrospectively reviewed 14 480 patients aged ≥ 18 years who underwent general anaesthesia. We identified 74 (0.5%) patients whose lungs were identif...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/anae.13153

    authors: Saito T,Liu W,Chew ST,Ti LK

    更新日期:2015-09-01 00:00:00

  • Comparison of forced-air warming and electric heating pad for maintenance of body temperature during total knee replacement.

    abstract::We conducted a randomised controlled trial to compare the efficacy of forced-air warming (Bair Hugger(trade mark), Augustine Medical model 500/OR, Prairie, MN) with that of an electric heating pad (Operatherm 202, KanMed, Sweden) for maintenance of intra-operative body temperature in 60 patients undergoing total knee ...

    journal_title:Anaesthesia

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/j.1365-2044.2006.04816.x

    authors: Ng V,Lai A,Ho V

    更新日期:2006-11-01 00:00:00

  • Comparison of rocuronium and suxamethonium for use during rapid sequence induction of anaesthesia.

    abstract::This study was designed to compare the tracheal intubating conditions during a rapid sequence induction of anaesthesia using rocuronium 0.6 (n = 61) or 1.0 mg.kg-1 (n = 130) or suxamethonium 1.0 mg.kg-1 (n = 127) as the neuromuscular blocking drugs. Anaesthesia was induced with fentanyl 1-2 micrograms.kg-1 and thiopen...

    journal_title:Anaesthesia

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1046/j.1365-2044.1998.00342.x

    authors: McCourt KC,Salmela L,Mirakhur RK,Carroll M,Mäkinen MT,Kansanaho M,Kerr C,Roest GJ,Olkkola KT

    更新日期:1998-09-01 00:00:00

  • Effect of midazolam on memory: a study of process dissociation procedure and functional magnetic resonance imaging.

    abstract::To assess the effects of midazolam on explicit and implicit memories, 12 volunteers were randomly divided into the two groups: one with an Observer's Assessment of Alertness/Sedation score of 3 (mild sedation) and one with a score of 1 (deep sedation). Blood oxygen-level-dependent functional magnetic resonance imaging...

    journal_title:Anaesthesia

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/j.1365-2044.2010.06343.x

    authors: Tian SY,Zou L,Quan X,Zhang Y,Xue FS,Ye TH

    更新日期:2010-06-01 00:00:00

  • The haemodynamic effects of intravenous induction. Comparison of the effects of thiopentone and propofol.

    abstract::The haemodynamic changes following induction of anaesthesia with equipotent doses of propofol and thiopentone have been compared. Propofol caused a significant fall in arterial blood pressure and total peripheral resistance, with a slight fall in cardiac output. There were no changes in heart rate. Apart from an initi...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/j.1365-2044.1985.tb10996.x

    authors: Grounds RM,Twigley AJ,Carli F,Whitwam JG,Morgan M

    更新日期:1985-08-01 00:00:00

  • Effect of propofol on seizure-like phenomena and electroencephalographic activity in children with epilepsy vs children with learning difficulties.

    abstract::There is an ongoing debate as to whether propofol exhibits pro- or anticonvulsant effects, and whether it should be used in patients with epilepsy. We prospectively assessed the occurrence of seizure-like phenomena and the effects of intravenous propofol on the electroencephalogram (EEG) in 25 children with epilepsy (...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/j.1365-2044.2006.04782.x

    authors: Meyer S,Shamdeen MG,Kegel B,Mencke T,Gottschling S,Gortner L,Grundmann U

    更新日期:2006-11-01 00:00:00

  • The potencies of edrophonium and neostigmine as antagonists of pancuronium.

    abstract::Dose response curves were constructed for edrophonium and neostigmine when used to antagonise pancuronium, 0.07 mg/kg during thiopentone-nitrous oxide-halothane anaesthesia. The antagonist was given when 10% twitch height had been restored and the effect was measured 10 minutes later. Recoveries to 50% and 90% twitch ...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/j.1365-2044.1985.tb11044.x

    authors: Breen PJ,Doherty WG,Donati F,Bevan DR

    更新日期:1985-09-01 00:00:00

  • Successful use of sugammadex in a 'can't ventilate' scenario.

    abstract::A 53-year-old man with hypopharyngeal stenosis following curative chemoradiotherapy for a tongue base tumour presented three years later for an attempt at pharyngeal dilatation. The first attempt 6 months previously was abandoned when awake fibreoptic intubation failed due to partial airway obstruction and desaturatio...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/anae.12338

    authors: Paton L,Gupta S,Blacoe D

    更新日期:2013-08-01 00:00:00

  • Intra-ocular pressure and premedication with oral diazepam.

    abstract::Thirty patients scheduled for routine eye surgery were randomly allocated to receive either diazepam 0.2 mg/kg or ascorbic acid 100 mg orally 90 minutes pre-operatively in a double-blind fashion. Diazepam caused no significant change in intra-ocular pressure. ...

    journal_title:Anaesthesia

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1111/j.1365-2044.1982.tb01112.x

    authors: Trew CT,Manus NJ,Jackson DM

    更新日期:1982-03-01 00:00:00

  • Postoperative obstructive sleep apnoea. Haemodynamic effects of treatment with nasal CPAP.

    abstract::A 74-year-old man presenting for aortic reconstructive surgery showed severe, previously undiagnosed obstructive sleep apnoea during overnight oximetry monitoring before operation. Postoperatively, in the first 4 hours following extubation, he suffered 238 episodes of respiratory obstruction. These events were associa...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/j.1365-2044.1991.tb09599.x

    authors: Reeder MK,Goldman MD,Loh L,Muir AD,Casey KR,Gitlin DA

    更新日期:1991-10-01 00:00:00

  • Patient-centred measurement of recovery from day-case surgery using wrist worn accelerometers: a pilot and feasibility study.

    abstract::This pilot and feasibility study evaluated wrist-worn accelerometers to measure recovery from day-case surgery in comparison with daily quality of recovery-15 scores. The protocol was designed with extensive patient and public involvement and engagement, and delivered by a research network of anaesthesia trainees. For...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/anae.15267

    authors: Ratcliffe AM,Zhai B,Guan Y,Jackson DG,South West Anaesthesia Research Matrix (SWARM).,Sneyd JR

    更新日期:2020-10-05 00:00:00

  • Resistance and additional inspiratory work imposed by the laryngeal mask airway. A comparison with tracheal tubes.

    abstract::Laryngeal mask airways and tracheal tubes were studied to determine both their resistance to constant gas flows and additional inspiratory work during simulated inspiration. Laryngeal mask airways imposed less resistance and required lower additional inspiratory work compared with the corresponding sized tracheal tube...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/j.1365-2044.1992.tb02179.x

    authors: Bhatt SB,Kendall AP,Lin ES,Oh TE

    更新日期:1992-04-01 00:00:00

  • Effect of amniotic fluid on coagulation and platelet function in pregnancy: an evaluation using thromboelastography.

    abstract::Amniotic fluid embolism is a rare obstetric complication. The exact pathogenesis of this syndrome remains unknown and significant controversy exists whether coagulopathy should always be present. We used thromboelastography to assess the effect of amniotic fluid on coagulation and platelet function in pregnant women. ...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/j.1365-2044.2005.04373.x

    authors: Harnett MJ,Hepner DL,Datta S,Kodali BS

    更新日期:2005-11-01 00:00:00

  • Pregnanolone emulsion. A preliminary pharmacokinetic and pharmacodynamic study of a new intravenous anaesthetic agent.

    abstract::Pregnanolone emulsion, a new steroid anaesthetic agent, was administered intravenously as bolus doses to six young healthy male volunteers in a preliminary pharmacokinetic and pharmacodynamic study. The plasma concentration-time curves fitted a two-compartment model. The elimination half-life was between 0.9 and 1.4 h...

    journal_title:Anaesthesia

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1365-2044.1990.tb14683.x

    authors: Carl P,Høgskilde S,Nielsen JW,Sørensen MB,Lindholm M,Karlen B,Bäckstrøm T

    更新日期:1990-03-01 00:00:00

  • The incidence of post dural puncture headache in children.

    abstract::One hundred and five children with malignant disease attended for lumbar puncture which was performed under general anaesthesia. A questionnaire was answered over the next three days to determine the incidence of post dural puncture headache Ninety-seven questionnaires were returned and the results show that no child ...

    journal_title:Anaesthesia

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1365-2044.1996.tb15061.x

    authors: Wee LH,Lam F,Cranston AJ

    更新日期:1996-12-01 00:00:00

  • Topical lignocaine and thiopentone for the insertion of a laryngeal mask airway; a comparison with propofol.

    abstract::We assessed conditions for insertion of a laryngeal mask airway in 90 unpremedicated adult patients who received either thiopentone 5 mg.kg-1 preceded by 40 mg of topical lignocaine spray to the posterior pharyngeal wall or propofol 2.5 mg.kg-1 alone in a randomised, single-blinded trial. All patients received fentany...

    journal_title:Anaesthesia

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1111/j.1365-2044.1996.tb07860.x

    authors: Seavell CR,Cook TM,Cox CM

    更新日期:1996-07-01 00:00:00

  • Intracranial hypotension headache after uncomplicated caudal epidural injection.

    abstract::A caudal epidural injection was performed on a middle-aged woman for pain in her right foot. Although the procedure was uncomplicated and a good epidurogram was obtained, the patient went on to develop an orthostatic headache with generalised weakness and syncopal episodes that were treated successfully by epidural bl...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/j.1365-2044.2011.06980.x

    authors: Thomas R,Thanthulage S

    更新日期:2012-04-01 00:00:00

  • Comparison of the Williams Airway Intubator and Ovassapian Fibreoptic Intubating Airway for fibreoptic orotracheal intubation.

    abstract::A randomised study was carried out in 60 anaesthetised patients with no evidence of airway difficulties, to compare the Williams Airway Intubator and the Ovassapian Fibreoptic Intubating Airway for bronchoscopic view and ease of railroading a tracheal tube during fibreoptic orotracheal intubation. The Williams Airway ...

    journal_title:Anaesthesia

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1111/j.1365-2044.2004.03527.x

    authors: Greenland KB,Lam MC,Irwin MG

    更新日期:2004-02-01 00:00:00

  • Hypercholinesterasaemia and suxamethonium resistance.

    abstract::A case is reported of resistance to the muscle relaxing action of suxamethonium due to the rare inherited condition of hypercholinesterasaemia. Family studies suggest dominant inheritance. It is suggested the condition should be considered whenever there is unexpected resistance to the muscle relaxing action of suxame...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/j.1365-2044.1987.tb04110.x

    authors: Warran P,Theeman M,Bold AM,Jones S

    更新日期:1987-08-01 00:00:00

  • The occupational hazard of human immunodeficiency virus and hepatitis B virus infection. II. Effect of grade, age, sex and region of employment on perceived risks and preventive measures adopted by anaesthetists.

    abstract::The effect of grade, age, sex and region of employment on the attitude of anaesthetists to the possible risk of Human Immunodeficiency Virus (HIV) and Hepatitis B Virus (HBV) infection and the measures adopted to minimise the risk were assessed. As a group, anaesthetists in training were more concerned than consultant...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/j.1365-2044.1992.tb03192.x

    authors: O'Donnell NG,Asbury AJ

    更新日期:1992-11-01 00:00:00

  • The oesophageal detector device. An assessment of accuracy and ease of use by paramedics.

    abstract::Accuracy, ease and speed of recognition of tracheal tube position were assessed using the oesophageal detector device in a series of 40 tests on 29 patients. A single blind method was used, with each paramedic performing a single test on each patient. The tests were randomly split between two groups consisting of thos...

    journal_title:Anaesthesia

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1111/j.1365-2044.1994.tb04259.x

    authors: Donahue PL

    更新日期:1994-10-01 00:00:00

  • A simulation-based evaluation of two proposed alternatives to Luer devices for use in neuraxial anaesthesia.

    abstract::The National Patient Safety Agency has issued a Patient Safety Alert with the aim of eliminating Luer connectors from equipment for lumbar puncture and subarachnoid injections by 1 April 2011, and from all neuraxial and regional anaesthesia equipment in 2013. B-link (UK) Ltd and InterVene Ltd have produced non-Luer co...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/j.1365-2044.2010.06537.x

    authors: Cook TM,Payne S,Skryabina E,Hurford D,Clow E,Georgiou A

    更新日期:2010-11-01 00:00:00

  • The effect of cardiac output on the onset of neuromuscular block by vecuronium.

    abstract::A relationship between cardiac output and the onset time of neuromuscular blockade administered into a peripheral vein was evaluated in 41 adult patients. Anaesthesia was induced with midazolam and fentanyl and maintained with intermittent doses of fentanyl and 66% nitrous oxide in oxygen. After immobilisation of the ...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/j.1365-2044.1995.tb04619.x

    authors: Iwasaki H,Igarashi M,Yamauchi M,Namiki A

    更新日期:1995-04-01 00:00:00

  • A disposable device for patient-controlled analgesia with fentanyl.

    abstract::A disposable nonelectronic patient-controlled analgesia device was used to deliver fentanyl after upper abdominal surgery. Pain relief was satisfactory and plasma fentanyl concentrations were similar to those obtained by other workers who used electronic patient-controlled analgesia devices. ...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/j.1365-2044.1989.tb09151.x

    authors: Rowbotham DJ,Wyld R,Nimmo WS

    更新日期:1989-11-01 00:00:00

  • Ideal versus corrected body weight for dosage of sugammadex in morbidly obese patients.

    abstract::To date, the dosing of sugammadex is based on real body weight without taking fat content into account. We compared the reversal of profound rocuronium-induced neuromuscular blockade in morbidly obese patients using doses of sugammadex based on four different weight corrections. One hundred morbidly obese patients, sc...

    journal_title:Anaesthesia

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/j.1365-2044.2011.06782.x

    authors: Van Lancker P,Dillemans B,Bogaert T,Mulier JP,De Kock M,Haspeslagh M

    更新日期:2011-08-01 00:00:00

  • Comparison of anxiety before induction of anaesthesia in the anaesthetic room or operating theatre.

    abstract::Anxiety before induction of anaesthesia was studied in 100 patients who were allocated randomly to one of two groups. Patients in one group were anaesthetised in an anaesthetic room and those in the other group were anaesthetised inside the operating theatre. Both subjective and objective induces of anxiety were used ...

    journal_title:Anaesthesia

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1111/j.1365-2044.1989.tb13586.x

    authors: Soni JC,Thomas DA

    更新日期:1989-08-01 00:00:00

  • Interaction between infusion equipment resulting in drug overdose in a critically ill patient.

    abstract::A critically ill septic patient on haemofiltration for acute renal failure suffered sudden circulatory and respiratory collapse. The cause of the collapse was traced to an interaction between mechanical devices (syringe driver infusion pumps and haemofiltration equipment) connected to two central venous catheters. ...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/j.1365-2044.2004.04012.x

    authors: Sundaram R,Dell AE

    更新日期:2005-01-01 00:00:00

  • Plasma morphine concentrations after intramuscular injection into the deltoid or gluteal muscles.

    abstract::The absorption of morphine 10 mg after intramuscular injection into the gluteal and deltoid muscles was investigated. Ten patients received the injection into the deltoid and 10 were given the injection into the upper outer quadrant of the buttock. Blood was taken at frequent intervals up to 2 hours after the injectio...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/j.1365-2044.1988.tb08976.x

    authors: Kirkpatrick T,Henderson PD,Nimmo WS

    更新日期:1988-04-01 00:00:00

  • Volume and pH of gastric contents following anticholinergic premedication.

    abstract::The effects of anticholinergic premedication with 1.0 mg atropine, 0.5 mg hyoscine and 0.2 mg glycopyrronium on volume and pH of gastric contents were studied and compared with a group receiving no anticholinergic premedication. The antisialogogue effects were also compared. Though the groups receiving atropine and gl...

    journal_title:Anaesthesia

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1111/j.1365-2044.1979.tb06323.x

    authors: Mirakhur RK,Reid J,Elliott J

    更新日期:1979-05-01 00:00:00