Abstract:
:Implantation of ultraviolet (UV) light-absorbing intraocular lenses and the manufacturers developing these lenses has significantly increased over the past few years. In this paper, the need for filtration of UV light by intraocular lens implants is briefly examined and various new product development aspects of a UV-absorbing IOL are discussed. Two general approaches, additive and chemical bonding, to incorporating a UV-absorbing chromophore into polymethylmethacrylate lens material are described. Different UV-absorbing compounds that are being used in implants and the mechanism by which they absorb light and its dissipation is discussed. The extent of preclinical testing required to establish the biocompatibility, stability, and overall safety of new materials is summarized. Finally, a relative comparison of the extent of UV absorption by various commercially available UV intraocular lenses is presented.
journal_name
J Cataract Refract Surgjournal_title
Journal of cataract and refractive surgeryauthors
Lindstrom RL,Doddi Ndoi
10.1016/s0886-3350(86)80011-6subject
Has Abstractpub_date
1986-05-01 00:00:00pages
285-9issue
3eissn
0886-3350issn
1873-4502pii
S0886-3350(86)80011-6journal_volume
12pub_type
杂志文章abstract:PURPOSE:To determine whether microcoaxial phacoemulsification can be reliably and safely performed in a clinical setting and whether a full-sized single-piece acrylic intraocular lens (IOL) can be implanted through a 2.2 mm incision. SETTING:Private practice, Cincinnati, Ohio, USA. METHOD:One hundred consecutive pati...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2006.10.055
更新日期:2007-03-01 00:00:00
abstract:PURPOSE:To propose an alternative method to characterize postocclusion surge using a collapsible artificial anterior chamber to replace the currently used rigid anterior chamber model. SETTING:Fundación Oftamológica Los Andes, Santiago, Chile. METHODS:The distal end of a phacoemulsification handpiece was placed insid...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2005.03.061
更新日期:2005-10-01 00:00:00
abstract:PURPOSE:To evaluate the results of 4-point scleral fixation of posterior chamber intraocular lenses (PC IOLs) in children. SETTING:Mansoura Ophthalmic Center, Mansoura University, Mansoura, Egypt. METHODS:This retrospective study comprised 20 aphakic eyes of 20 children. Preoperative investigations proved the absence...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(02)01531-6
更新日期:2003-02-01 00:00:00
abstract:PURPOSE:To develop a system for high-resolution imaging of the posterior lens capsule after intraocular lens surgery for objective assessment of posterior capsule opacification (PCO). SETTING:Department of Cataract and Refractive Surgery, St. Thomas' Hospital, London, United Kingdom. METHODS:A system was developed th...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(97)80023-5
更新日期:1997-12-01 00:00:00
abstract:PURPOSE:To describe the use of a motorized milling drill to perform nonpenetrating glaucoma surgery and to assess its safety. SETTING:Instituto Oftalmológico de Alicante, Miguel Hernandez University, School of Medicine, Alicante, Spain. METHODS:This prospective noncomparative study included 16 eyes (13 patients) diag...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2003.11.052
更新日期:2004-07-01 00:00:00
abstract:PURPOSE:To assess the potential effect of surface light scattering on light transmittance of 1-piece hydrophobic acrylic intraocular lenses (IOLs) with or without a blue-light filter. SETTING:John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. DESIGN:Experimental study. METHODS:Intraocular lense...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2013.05.050
更新日期:2014-01-01 00:00:00
abstract:PURPOSE:To compare the centration and fixation of silicone plate-haptic intraocular lenses (IOLs) with different-sized positioning holes. SETTING:Eye Clinic of the Johannes Gutenberg-University Mainz, Mainz, Germany. METHODS:In a prospective randomized study, 51 Chiroflex C10 and 56 Chiroflex C11 IOLs were implanted ...
journal_title:Journal of cataract and refractive surgery
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1016/s0886-3350(00)00496-x
更新日期:2000-12-01 00:00:00
abstract:PURPOSE:To use the double-pass technique to evaluate the in vitro optical quality of foldable monofocal intraocular lenses (IOLs) used to correct aphakia. SETTING:Universitat Politècnica de Catalunya, Terrassa, and Instituto de Microcirugía Ocular de Barcelona, Barcelona, Spain; Universidad Nacional de Tucumán, Tucumá...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2009.03.022
更新日期:2009-08-01 00:00:00
abstract::A 43-year-old white woman with a history of multiple ocular surgeries, including 4 penetrating keratoplasties, developed a concentric retrocorneal membrane at the graft periphery in the right eye. A white-light, tandem, scanning confocal microscope using a 24x/0.60 contact objective was used to examine the right eye i...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(99)00133-9
更新日期:1999-08-01 00:00:00
abstract:PURPOSE:Previous studies have reported conflicting results on the influence of seasons on post-cataract surgery endophthalmitis incidences. This study aimed to investigate the seasonality associated with the incidence of postoperative endophthalmitis, and to evaluate its association with climate variables in South Kore...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2019.07.022
更新日期:2019-12-01 00:00:00
abstract:PURPOSE:To examine the profile of clear corneal cataract incisions in the living eye using optical coherence tomography (OCT). SETTING:Private practice, Eugene, Oregon, USA. METHODS:The Zeiss Visante OCT anterior segment imaging system was used to study the profile of clear corneal cataract incisions, all in senior c...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2006.09.016
更新日期:2007-01-01 00:00:00
abstract:PURPOSE:To evaluate the long-term evolution of refractive error changes in eyes of children who have primary intraocular lens (IOL) implantation to allow more accurate prediction of what IOL power should be implanted at a given age. SETTING:Department of Ophthalmology, Indiana University School of Medicine, Indianapol...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(01)01156-7
更新日期:2002-05-01 00:00:00
abstract::A retrospective study of 98 91Z anterior chamber intraocular lenses used with intracapsular cataract extraction was performed. Minimum follow-up was 12 months and average follow-up was two years seven months. These patients were part of a group of 113 91Z patients previously reported with minimum six-months follow-up ...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(86)80104-3
更新日期:1986-07-01 00:00:00
abstract::We report 2 cases of serous macular detachment with intraretinal fluid accumulation that developed 1 day after uneventful phacoemulsification surgery. Because of a dilution error, both eyes received 2 mg/0.1 mL of intracameral cefuroxime at the end of surgery. On postoperative day 1, the corrected distance visual acui...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2010.07.007
更新日期:2010-11-01 00:00:00
abstract:PURPOSE:To evaluate transient increases in intraocular pressure (IOP) after use of high-viscosity viscoelastic agents in cataract surgery. SETTING:Military Hospital, Ulm, Germany. METHODS:In a prospective, randomized study, we evaluated IOP following cataract surgery using two different viscoelastic substances (Healo...
journal_title:Journal of cataract and refractive surgery
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1016/s0886-3350(96)80224-0
更新日期:1996-03-01 00:00:00
abstract:PURPOSE:To compare the accuracy of a handheld infrared digital pupillometer and digital infrared photography for measurement of the dark-adapted pupil diameter. SETTING:Department of Ophthalmology and Visual Sciences, Texas Tech University Health Sciences Center, Lubbock, Texas, USA. METHODS:The right horizontal pupi...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2009.09.025
更新日期:2010-02-01 00:00:00
abstract::Recently manufactured intraocular lenses (IOLs) (STAAR AA 4203 made of silicone and IOGEL PC-12 made of polyHEMA) were tested before and after implantation simulation for axial optical resolution (model eye), for optical surface quality (photokeratoscope), and for surface microtrauma (scanning electron microscopy). At...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(13)80733-x
更新日期:1990-03-01 00:00:00
abstract:PURPOSE:To evaluate the reduction in the anterior capsule opening after phacoemulsification, continuous curvilinear capsulorhexis, and implantation of 1 of 2 acrylic intraocular lenses (IOLs). SETTING:Department of Ophthalmology, Vejle Hospital, Vejle, Denmark. METHODS:Eighty-four patients (84 eyes) were included in ...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章,随机对照试验
doi:10.1016/j.jcrs.2007.01.020
更新日期:2007-05-01 00:00:00
abstract:PURPOSE:To evaluate the effect of removal and/or exchange of intrastromal corneal ring segments (ICRS, Intacs); specifically the risk factors, degree of reversibility, and visual outcomes. SETTING:Gimbel Eye Centres, Calgary, Edmonton, and Vancouver, Canada. METHODS:Prospective cohort data were collected on 71 eyes t...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(01)01172-5
更新日期:2002-04-01 00:00:00
abstract:PURPOSE:To evaluate the benefit of various surgical methods to address pseudophakic negative dysphotopsia. SETTING:Private practice, Los Angeles, California, USA. DESIGN:Interventional case series. METHODS:The following 4 surgical methods were used to treat negative dysphotopsia: secondary piggyback intraocular lens...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2011.02.022
更新日期:2011-07-01 00:00:00
abstract:PURPOSE:To compare complication rates, visual acuity, and refractive outcomes of secondary intraocular lens (IOLs) implantation. SETTING:Department of Ophthalmology, Cullen Eye Institute, Baylor College of Medicine, Houston, Texas, USA. DESIGN:Retrospective case series. METHODS:All secondary IOLs placed by the anter...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2016.12.024
更新日期:2017-03-01 00:00:00
abstract::The accuracy of intraocular lens (IOL) power calculation was evaluated in a multicenter study of 822 IOL implantations using the Binkhorst II, Sanders/Retzlaff/Kraff (SRK I, SRK II, SRK/T), Holladay, and Olsen formulas. All but the first of these were optimized in retrospect with calculation of the SRK A-constant, the...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章,多中心研究
doi:10.1016/s0886-3350(13)80140-x
更新日期:1995-05-01 00:00:00
abstract:PURPOSE:To determine the predictability and consistency of corneal flap thickness, flap diameter, and hinge length with the modern 100 microm head of the Moria LSK-One manual microkeratome. SETTING:Private clinic, office-based practice. METHODS:Forty-two consecutive eyes with no previous surgery having thin flap lase...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2004.10.056
更新日期:2005-06-01 00:00:00
abstract::We developed a formula to measure the posterior curvature of the cornea. In our study, real corneal power in 51 eyes was calculated by using anterior and posterior curvatures and corneal thickness. The corneal refractive index was found to be a variable value between 1.3243 and 1.3339 (mean 1.3304 +/- 0.0003). ...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(13)80151-4
更新日期:1994-03-01 00:00:00
abstract::This case outlines the phacoemulsification technique used to overcome the challenge of the hyperdeep anterior chamber, weak zonules, abnormal anterior capsule, and large capsular bag. Key steps included trypan blue staining of the anterior capsule, a large capsulorhexis, prolapse of the nucleus into the anterior chamb...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2005.12.143
更新日期:2006-07-01 00:00:00
abstract:PURPOSE:To evaluate visual outcomes and patient satisfaction after toric multifocal intraocular lens (IOL) implantation in patients with cataract and corneal astigmatism. SETTING:University Eye Clinic Maastricht, The Netherlands. DESIGN:Cohort study. METHODS:Patients with cataract, corneal astigmatism, and a motivat...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2011.05.041
更新日期:2011-11-01 00:00:00
abstract:PURPOSE:To investigate if a combination of topical nonsteroid anti-inflammatory drugs (NSAIDs) and steroids were superior in controlling early postoperative inflammation after cataract surgery compared with topical NSAIDs alone and with dropless surgery where a subtenon depot of steroid was placed during surgery. SETT...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1097/j.jcrs.0000000000000455
更新日期:2020-10-16 00:00:00
abstract::We developed and evaluated a method of visualizing vitreous gel in the anterior segment. In this study, 0.2 mL of injectable triamcinolone (Kenalog) 40 mg/mL was captured in a 5 microm filter and rinsed with 2 mL of balanced salt solution (BSS). It was then resuspended in 5 mL of BSS and recaptured to thoroughly remov...
journal_title:Journal of cataract and refractive surgery
pub_type: 临床试验,杂志文章
doi:10.1016/s0886-3350(03)00016-6
更新日期:2003-04-01 00:00:00
abstract::Capsular bag distension syndrome (CBDS) is a rare complication of cataract surgery due to collection of fluid behind the intraocular lens (IOL). Nd:Yag laser capsulotomy is commonly performed to release the fluid collection; however, the potential risk of infection and inflammation has led to adaptation of numerous su...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1097/j.jcrs.0000000000000362
更新日期:2020-12-01 00:00:00
abstract::We describe a case of pigmentary dispersion syndrome resulting from secondary piggyback implantation of a 3-piece hydrophobic acrylic squared-edged intraocular lens (IOL) in the ciliary sulcus. The intraocular pressure remained elevated despite pharmacological treatment, with a heavily pigmented trabecular meshwork. T...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2007.01.044
更新日期:2007-06-01 00:00:00