High-resolution digital retroillumination imaging of the posterior lens capsule after cataract surgery.

Abstract:

PURPOSE:To develop a system for high-resolution imaging of the posterior lens capsule after intraocular lens surgery for objective assessment of posterior capsule opacification (PCO). SETTING:Department of Cataract and Refractive Surgery, St. Thomas' Hospital, London, United Kingdom. METHODS:A system was developed that uses coaxial illumination and imaging based on Zeiss components with a digital camera directly linked to a computer for online image verification and image analysis. RESULTS:The system produced high-resolution digital images with even background illumination of sufficient quality to demonstrate progressive lens epithelial cell changes that are amenable to computer image analysis. CONCLUSION:This system produced excellent images for objective documentation and quantitative measurement of PCO.

authors

Pande MV,Ursell PG,Spalton DJ,Heath G,Kundaiker S

doi

10.1016/s0886-3350(97)80023-5

subject

Has Abstract

pub_date

1997-12-01 00:00:00

pages

1521-7

issue

10

eissn

0886-3350

issn

1873-4502

pii

S0886-3350(97)80023-5

journal_volume

23

pub_type

杂志文章
  • Safety and efficacy of incisional goniotomy as an adjunct with phacoemulsification in primary angle-closure glaucoma.

    abstract:PURPOSE:To evaluate the intraocular pressure (IOP)-lowering efficacy and safety of incisional goniotomy as an adjunct to phacoemulsification in primary angle-closure glaucoma (PACG) patients. METHODS:In this prospective interventional case series, consecutive patients with PACG (high or borderline IOP) deemed fit for ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1097/j.jcrs.0000000000000481

    authors: Gupta S,Sethi A,Yadav S,Optom M,Azmira K,Singh A,Gupta V

    更新日期:2020-11-19 00:00:00

  • Streamlined method for anchoring cataract surgery and intraocular lens centration on the patient's visual axis.

    abstract::I describe an intraoperative method for the consistent anchoring of the intraocular lens (IOL) and cataract surgery and on the patient's visual axis using coaxial microscope optics, surgeon-guided patient fixation, the precision pulse capsulotomy (PPC) device (Zepto) and utilizing the first (and fourth) Purkinje image...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2018.02.013

    authors: Thompson V

    更新日期:2018-05-01 00:00:00

  • Changes in higher-order aberrations after implantation of a foldable iris-claw lens in myopic phakic eyes.

    abstract:PURPOSE:To evaluate the change in higher-order aberrations (HOAs) after implantation of a foldable iris-claw phakic intraocular lens (pIOL) in myopic eyes. SETTING:Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. METHODS:This prospective nonrandomized comparative self-controlled trial inclu...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2005.12.036

    authors: Tehrani M,Dick HB

    更新日期:2006-02-01 00:00:00

  • Biometry and intraocular lens power calculation results with a new optical biometry device: comparison with the gold standard.

    abstract:PURPOSE:To evaluate the agreement in axial length (AL), keratometry (K), anterior chamber depth (ACD) measurements; intraocular lens (IOL) power calculations; and predictability using a new partial coherence interferometry (PCI) optical biometer (AL-Scan) and a reference (gold standard) PCI optical biometer (IOLMaster ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2013.09.015

    authors: Kaswin G,Rousseau A,Mgarrech M,Barreau E,Labetoulle M

    更新日期:2014-04-01 00:00:00

  • Intacs insertion with the femtosecond laser for the management of keratoconus: one-year results.

    abstract:PURPOSE:To assess the outcomes of intrastromal ring segment (Intacs, Addition Technology) implantation for keratoconus using the femtosecond laser. SETTING:Kudret Eye Hospital, Ankara, Turkey. METHODS:In a retrospective noncomparative case series, 118 eyes of 69 patients with keratoconus who had Intacs segments impla...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2006.08.032

    authors: Ertan A,Kamburoğlu G,Bahadir M

    更新日期:2006-12-01 00:00:00

  • Formula choice: Hoffer Q, Holladay 1, or SRK/T and refractive outcomes in 8108 eyes after cataract surgery with biometry by partial coherence interferometry.

    abstract:PURPOSE:To assess how intraocular lens (IOL) formula choice affects refractive outcomes after cataract surgery using IOLMaster biometry. SETTING:Department of Ophthalmology, Gloucestershire Hospitals NHS Foundation Trust, Cheltenham, United Kingdom. DESIGN:Database study. METHODS:Hypothetical prediction errors were ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2010.07.032

    authors: Aristodemou P,Knox Cartwright NE,Sparrow JM,Johnston RL

    更新日期:2011-01-01 00:00:00

  • Comparison of effective phacoemulsification time and corneal endothelial cell loss using 2 ultrasound frequencies.

    abstract:PURPOSE:To compare 2 ultrasound (US) frequencies for phacoemulsification for moderate to hard cataract to determine a frequency that makes phacoemulsification safer and more efficacious. SETTING:Post Graduate Institute of Medical Education and Research, New Delhi, India. DESIGN:Randomized controlled trial. METHODS:P...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.jcrs.2019.04.015

    authors: Dewan T,Malik PK,Kumari R

    更新日期:2019-09-01 00:00:00

  • Bilateral Candida parapsilosis interface keratitis after laser in situ keratomileusis.

    abstract::We report a case of Candida infection after laser in situ keratomileusis (LASIK) and review the literature for reports of post-LASIK fungal infections. Risk factors may include postoperative surgical intervention and extended use of topical steroids. ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(03)00217-7

    authors: Muallem MS,Alfonso EC,Romano AC,Miller D,Kurstin J,Marangon FB,Culbertson WW,Yoo SH

    更新日期:2003-10-01 00:00:00

  • Mean shape of the human limbus.

    abstract:PURPOSE:To characterize the mean topographic shape of the limbus of a normal human eye and determine whether it depends on age or refractive power. SETTING:University of Manchester, Manchester, United Kingdom. DESIGN:Prospective case series. METHODS:Participants with no previous ocular surgeries were included in thi...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2017.02.027

    authors: Consejo A,Llorens-Quintana C,Radhakrishnan H,Iskander DR

    更新日期:2017-05-01 00:00:00

  • Intraindividual comparison of the effects of a fixed dorzolamide-timolol combination and latanoprost on intraocular pressure after small incision cataract surgery.

    abstract::To compare the effect of a fixed dorzolamide-timolol combination with that of latanoprost on intraocular pressure (IOP) after small incision cataract surgery. Department of Ophthalmology, University of Vienna, Vienna, Austria. This prospective randomized study comprised 60 eyes of 30 patients scheduled for small incis...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1016/s0886-3350(00)00706-9

    authors: Rainer G,Menapace R,Findl O,Petternel V,Kiss B,Georgopoulos M

    更新日期:2001-05-01 00:00:00

  • Endothelial damage caused by uncoated and fluorocarbon-coated poly(methyl methacrylate) intraocular lenses.

    abstract:PURPOSE:To assess endothelial damage induced by poly(methyl methacrylate) (PMMA) intraocular lenses (IOLs) coated with a fluorocarbon polymer, Teflon AF, to make them highly hydrophobic. SETTING:Department of Ophthalmology. Hôtel-Dieu Hospital, Paris, France. METHODS:Ten Teflon-coated and 10 uncoated PMMA IOLs were u...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(97)80073-9

    authors: Werner LP,Legeais JM,Durand J,Savoldelli M,Legeay G,Renard G

    更新日期:1997-09-01 00:00:00

  • Milling trabeculoplasty for nonpenetrating glaucoma surgery.

    abstract:PURPOSE:To describe the use of a motorized milling drill to perform nonpenetrating glaucoma surgery and to assess its safety. SETTING:Instituto Oftalmológico de Alicante, Miguel Hernandez University, School of Medicine, Alicante, Spain. METHODS:This prospective noncomparative study included 16 eyes (13 patients) diag...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2003.11.052

    authors: Rodríguez-Prats JL,Alió JL,Galal A

    更新日期:2004-07-01 00:00:00

  • Optical resolution of silicone and polymethylmethacrylate intraocular lenses.

    abstract::The optical resolution and contrast of 18 silicone and 18 polymethylmethacrylate (PMMA) intraocular lenses were determined before implantation in and after removal from rabbit eyes. A specially designed microphotographic system that allows documentation and comparison of the image quality of different lens types was u...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(87)80153-0

    authors: Kulnig W,Menapace R,Skorpik C,Juchem M

    更新日期:1987-11-01 00:00:00

  • Cytokeratin in lens epithelial cells and its effect on anterior lens capsule opacification.

    abstract::Postoperative lens capsule opacification is a complication of extracapsular cataract extraction. To avoid this problem, we aspirated the epithelial cells lining the internal surface of the capsular bag. Anterior capsule specimens collected three and six years after the first surgical intervention (extracapsular catara...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(13)80302-1

    authors: Budo C,Montanus F,Goffinet G,Goossens G,Gaill F

    更新日期:1993-05-01 00:00:00

  • Visual acuity tolerance to residual refractive errors in patients with an apodized diffractive intraocular lens.

    abstract:PURPOSE:To assess visual acuity tolerance to defocus caused by residual refractive errors after clear lens extraction (CLE) with apodized diffractive intraocular lens (IOL) implantation. SETTING:Fernández-Vega Ophthalmological Institute, Oviedo, Spain. METHODS:In this prospective study, 150 eyes of 75 consecutive pat...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2007.10.020

    authors: Fernández-Vega L,Alfonso JF,Montés-Micó R,Amhaz H

    更新日期:2008-02-01 00:00:00

  • Phacofragmentation with perfluorocarbon liquid and anterior chamber or scleral-fixated intraocular lens implantation for the management of luxated crystalline lenses.

    abstract:PURPOSE:To present a complex surgical technique used for the management of luxated crystalline lenses and evaluate treatment results. SETTING:Department of Ophthalmology, Medical University of Lodz, Lodz, Poland. METHODS:This prospective study involved 29 consecutive patients (30 eyes) with the mean age of 60.3 years...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2005.04.039

    authors: Omulecki W,Stolarska K,Synder A

    更新日期:2005-11-01 00:00:00

  • Early postoperative safety and surgical outcomes after implantation of a suprachoroidal micro-stent for the treatment of open-angle glaucoma concomitant with cataract surgery.

    abstract:PURPOSE:To evaluate the safety of a new suprachoroidal device, the Cypass micro-stent, for the surgical treatment of open-angle glaucoma (OAG) implanted in conjunction with cataract surgery. SETTING:Multicenter clinical study. DESIGN:Prospective interventional case series. METHODS:This is an interim report of an ong...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章,多中心研究

    doi:10.1016/j.jcrs.2012.10.040

    authors: Hoeh H,Ahmed II,Grisanti S,Grisanti S,Grabner G,Nguyen QH,Rau M,Yoo S,Ianchulev T

    更新日期:2013-03-01 00:00:00

  • Radial keratotomy learning curve using the American technique.

    abstract:PURPOSE:To delineate the learning curve for a beginning refractive surgeon using the centrifugal (American) technique. SETTING:Naval Medical Center, San Diego, California, USA. METHODS:The first 100 radial keratotomy (RK) cases (51 patients) of one surgeon, divided into five sequential groups of 20, were retrospectiv...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(98)80286-1

    authors: Blanton CL,Schallhorn SC,Tidwell JL

    更新日期:1998-04-01 00:00:00

  • Effect of incision length, location, and shape on local corneoscleral deformation during cataract surgery.

    abstract::The effect of incision length, location, and shape on the structural integrity of the globe was examined using finite element analysis by comparing the radial deformation of the corneoscleral tissue adjacent to the incision. The results show that incision length had the greatest adverse effect, 12 mm incisions causing...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(13)80879-6

    authors: Armeniades CD,Boriek A,Knolle GE Jr

    更新日期:1990-01-01 00:00:00

  • Laser flap enhancement 5 to 9 years and 10 or more years after laser in situ keratomileusis: Safety and efficacy.

    abstract:PURPOSE:To study the safety and efficacy of refractive enhancement by flap lifting 5 and 10 years after laser in situ keratomileusis (LASIK). SETTING:Vissum Alicante, Spain. DESIGN:Retrospective case series. METHODS:Eyes with a flap lift at least 5 years after primary LASIK with a 3-month follow-up were evaluated. T...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2019.05.030

    authors: Alió Del Barrio JL,Hanna R,Canto-Cerdan M,Vega-Estrada A,Alió JL

    更新日期:2019-10-01 00:00:00

  • Predictability of the vault after posterior chamber phakic intraocular lens implantation using anterior segment optical coherence tomography.

    abstract:PURPOSE:To determine whether vault measurements after placement of a hole implantable collamer lens (hole ICL) (KS-AquaPORT) can be predicted by angle-to-angle (ATA) and white-to-white (WTW) measurements obtained with anterior segment optical coherence tomography (AS-OCT). SETTING:Sanno Hospital, Tokyo, Japan. DESIGN...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2019.02.020

    authors: Igarashi A,Shimizu K,Kato S,Kamiya K

    更新日期:2019-08-01 00:00:00

  • Aspergillus fumigatus keratitis following laser in situ keratomileusis.

    abstract::A 31-year-old woman developed pain, decreased vision, and a corneal flap infiltrate 4 days following laser in situ keratomileusis (LASIK). Treatment with topical antibiotic agents did not improve the symptoms. Approximately 2 weeks after surgery, the patient was referred to Stanford University, with 20/400 visual acui...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2007.05.051

    authors: Sun Y,Jain A,Ta CN

    更新日期:2007-10-01 00:00:00

  • Using artificial intelligence to predict the risk for posterior capsule opacification after phacoemulsification.

    abstract:PURPOSE:To apply artificial intelligence models to predict the occurrence of posterior capsule opacification (PCO) after phacoemulsification. SETTING:Farabi Eye Hospital, Tehran, Iran. DESIGN:Clinical-based cross-sectional study. METHODS:The posterior capsule status of eyes operated on for age-related cataract and t...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2011.09.036

    authors: Mohammadi SF,Sabbaghi M,Z-Mehrjardi H,Hashemi H,Alizadeh S,Majdi M,Taee F

    更新日期:2012-03-01 00:00:00

  • Seasonal variation in acute post-cataract surgery endophthalmitis incidences in South Korea.

    abstract:PURPOSE:Previous studies have reported conflicting results on the influence of seasons on post-cataract surgery endophthalmitis incidences. This study aimed to investigate the seasonality associated with the incidence of postoperative endophthalmitis, and to evaluate its association with climate variables in South Kore...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2019.07.022

    authors: Kim SH,Yu MH,Lee JH,Yoon JS,Rah SH,Choi M

    更新日期:2019-12-01 00:00:00

  • Modified posterior-assisted levitation with intraocular lens scaffold and glued IOL for sinking nucleus in eyes with inadequate sulcus support.

    abstract::Posterior-assisted levitation is used to retrieve and levitate a sinking nucleus in cataract surgery associated with posterior capsule rupture. After the nucleus is levitated in the anterior chamber, the intraocular lens (IOL) scaffold procedure helps emulsify the nuclear remnants with the phacoemulsification probe an...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2017.06.004

    authors: Narang P,Agarwal A

    更新日期:2017-07-01 00:00:00

  • Accuracy and predictability of intraocular lens power calculation after photorefractive keratectomy.

    abstract:PURPOSE:To investigate the accuracy and predictability of intraocular lens (IOL) power calculation in postoperative photorefractive keratectomy (PRK) eyes. SETTING:Gimbel Eye Centre, Calgary, Alberta, Canada. METHODS:The results in 5 cataract surgery eyes that had had PRK were analyzed retrospectively. Target refract...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(00)00480-6

    authors: Gimbel HV,Sun R,Furlong MT,van Westenbrugge JA,Kassab J

    更新日期:2000-08-01 00:00:00

  • Performance of the 1CU accommodating intraocular lens in relation to capsulorhexis size.

    abstract:PURPOSE:To assess the correlation between continuous curvilinear capsulorhexis (CCC) size and visual outcomes in patients with an accommodating intraocular lens (IOL). SETTING:Heidelberg IOL and Refractive Surgery Research Group, Department of Ophthalmology, Ruprecht-Karls-University of Heidelberg, Heidelberg, Germany...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2004.02.071

    authors: Vargas LG,Auffarth GU,Becker KA,Rabsilber TM,Holzer MP

    更新日期:2005-02-01 00:00:00

  • Comparative analysis of brilliant blue G and an intracameral illuminator in assisting visualization of the anterior capsule in eyes with vitreous hemorrhage.

    abstract:PURPOSE:To compare the safety and efficacy of 0.025 mg/mL brilliant blue G (BBG) and an intracameral illuminator for visualizing the anterior capsule. SETTING:University-based tertiary referral center, South Korea. DESIGN:Retrospective cases series. METHODS:The medical records of patients with vitreous hemorrhage fo...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2016.03.038

    authors: Park YM,Park JY,Lee JS,Lee JE,Byon IS,Park SW

    更新日期:2016-07-01 00:00:00

  • Photorefractive keratectomy for residual myopia after radial keratotomy.

    abstract:PURPOSE:To evaluate the results of photorefractive keratectomy (PRK) to treat undercorrected radial keratotomy (RK). SETTING:Instituto de Oftalmologia Tadeu Cvintal, São Paulo, Brazil. METHODS:A consecutive series of 28 eyes that had PRK to treat residual myopia after RK were studied. Refractive visual and safety dat...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(96)80189-1

    authors: John ME,Martines E,Cvintal T

    更新日期:1996-09-01 00:00:00

  • Light transmittance of 1-piece hydrophobic acrylic intraocular lenses with surface light scattering removed from cadaver eyes.

    abstract:PURPOSE:To assess the potential effect of surface light scattering on light transmittance of 1-piece hydrophobic acrylic intraocular lenses (IOLs) with or without a blue-light filter. SETTING:John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. DESIGN:Experimental study. METHODS:Intraocular lense...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2013.05.050

    authors: Werner L,Morris C,Liu E,Stallings S,Floyd A,Ollerton A,Leishman L,Bodnar Z

    更新日期:2014-01-01 00:00:00