Features of positional magnetic resonance imaging in tethered cord syndrome.

Abstract:

PURPOSE:Tethered cord syndrome (TCS) is a clinical entity in which symptoms are induced through excessive tension on the spinal cord. The radiological method of choice to confirm TCS is magnetic resonance imaging (MRI), however limitations exist especially in patients with no underlying spinal dysraphism. MATERIALS AND METHODS:The positional MRI features of TCS in a series of four patients with suspected or proven TCS are described, especially with respect to contact of the myelon or the cauda equina with the dorsal elements of the lumbar spinal canal. The findings are correlated with the lordosis angle of the lumbar spine. RESULTS:In flexion contact of the myelon or the cauda equina with the dorsal elements of the lumbar spinal canal is reduced due to a straightening of the lumbar spine. With increasing lordosis of the lumbar spine, the degree of contact increases and detection of TCS is more difficult. The site of tethering could be identified in all four patients in flexion. CONCLUSION:Positional MRI can be useful to confirm or rule out TCS and helpful to identify the site of tethering. The value of positional MRI is limited to patients who are able to fully flex the lumbar spine and in patients without spinal canal stenosis and spondylolisthesis.

journal_name

Clin Neuroradiol

journal_title

Clinical neuroradiology

authors

Niggemann P,Sarikaya-Seiwert S,Beyer HK,Sobottke R

doi

10.1007/s00062-010-0049-y

subject

Has Abstract

pub_date

2011-04-01 00:00:00

pages

11-5

issue

1

eissn

1869-1439

issn

1869-1447

journal_volume

21

pub_type

杂志文章
  • Comparison of ESWAN, SWI-SPGR, and 2D T2*-weighted GRE sequence for depicting cerebral microbleeds.

    abstract:PURPOSE:We aimed to compare images obtained with an Enhanced 3D multi-echo GRE T2*-weighted angiography (ESWAN) sequence with those obtained with a susceptibility-weighted imaging-spoiled gradient-recalled echo (SWI-SPGR) sequence and a two-dimensional (2D) T2*-weighted gradient-recalled echo (GRE) sequence for the des...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-012-0185-7

    authors: Guo LF,Wang G,Zhu XY,Liu C,Cui L

    更新日期:2013-06-01 00:00:00

  • MDCT-based Finite Element Analysis of Vertebral Fracture Risk: What Dose is Needed?

    abstract:PURPOSE:The aim of this study was to compare vertebral failure loads, predicted from finite element (FE) analysis of patients with and without osteoporotic vertebral fractures (OVF) at virtually reduced dose levels, compared to standard-dose exposure from multidetector computed tomography (MDCT) imaging and evaluate wh...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-018-0722-0

    authors: Anitha D,Mei K,Dieckmeyer M,Kopp FK,Sollmann N,Zimmer C,Kirschke JS,Noel PB,Baum T,Subburaj K

    更新日期:2019-12-01 00:00:00

  • Posterior Circulation Occlusions May Be Associated with Distal Emboli During Thrombectomy : Factors for Distal Embolization and a Review of the Literature.

    abstract:BACKGROUND:Distal embolization or movement of the thrombus to previously uninvolved vasculature are feared complications during stroke thrombectomy. We looked at associated factors in a consecutive series of patients who underwent thrombectomy with the same endovascular device. METHODS:We included all patients with ac...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00062-018-0679-z

    authors: Yeo LLL,Holmberg A,Mpotsaris A,Söderman M,Holmin S,Kuntze Söderqvist A,Ohlsson M,Bhogal P,Gontu V,Andersson T,Brouwer PA

    更新日期:2019-09-01 00:00:00

  • Magnetic resonance imaging in transient global amnesia: lessons learned from 198 cases.

    abstract:PURPOSE:Patients with transient global amnesia (TGA) present with a characteristic clinical syndrome although other differential diagnoses have to be considered. Diffusion-weighted imaging (DWI) represents a highly specific diagnostic tool in the context of TGA; however, standard clinical DWI often fails to detect the ...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-012-0140-7

    authors: Scheel M,Malkowsky C,Klingebiel R,Schreiber SJ,Bohner G

    更新日期:2012-12-01 00:00:00

  • Prevalence of incidental narrowing of the superior segment of the internal jugular vein in patients without multiple sclerosis.

    abstract:PURPOSE:Internal jugular vein (IJV) narrowing superiorly is likely relatively frequent. IJV narrowing has been proposed as a potential pathophysiologic component for multiple sclerosis (MS). Our purpose was to investigate the prevalence of incidental superior IJV narrowing in patients imaged with neck computed tomograp...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-013-0232-z

    authors: Diehn FE,Schwartz KM,Hunt CH,Eckel LJ,Campeau NG,Carter RE,Allred JB,Kallmes DF

    更新日期:2014-06-01 00:00:00

  • Management of Unruptured Saccular Aneurysms of the M1 Segment with Flow Diversion : A Single Centre Experience.

    abstract:PURPOSE:The optimal strategy for the treatment of M1 segment aneurysms has not yet been determined as both standard microneurosurgical and endovascular techniques can pose challenges. We sought to determine the efficacy of flow diverting stents to treat small, unruptured aneurysms of the M1 segment. METHODS:We retrosp...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-016-0553-9

    authors: Bhogal P,Martinez R,Gansladt O,Bäzner H,Henkes H,Aguilar M

    更新日期:2018-06-01 00:00:00

  • Subtle Imaging Findings Aid the Diagnosis of Adolescent Hereditary Spastic Paraplegia and Ataxia.

    abstract:PURPOSE:Hereditary spastic paraplegia (HSP) and hereditary spastic ataxia (HSA) are a heterogeneous group of genetic disorders characterized by progressive lower limb spasticity resulting from pyramidal tract dysfunction. By identifying critical imaging findings within the clinical context of spasticity, radiologists a...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-018-0665-5

    authors: Wagner F,Titelbaum DS,Engisch R,Coskun EK,Waugh JL

    更新日期:2019-06-01 00:00:00

  • Parametric color coding of digital subtraction angiography in the evaluation of carotid cavernous fistulas.

    abstract:PURPOSE:Angiographic assessment of carotid cavernous fistulas (CCFs) can be complex. Our purpose was to examine whether the use of parametric color coding in the postprocessing of DSA series is advantageous in the evaluation of CCFs. METHODS:We enrolled 16 patients with angiographically proven CCFs. Endovascular treat...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-012-0184-8

    authors: Gölitz P,Struffert T,Lücking H,Rösch J,Knossalla F,Ganslandt O,Deuerling-Zheng Y,Doerfler A

    更新日期:2013-06-01 00:00:00

  • Quantitative Susceptibility Mapping: Concepts and Applications.

    abstract:PURPOSE:To review the fundamental principles of susceptibility-weighted imaging (SWI) and quantitative susceptibility mapping (QSM), and to discuss recent clinical developments. METHODS:SWI is a magnetic resonance imaging method that takes advantage of magnitude signal loss and phase information to reveal anatomic and...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00062-015-0432-9

    authors: Reichenbach JR,Schweser F,Serres B,Deistung A

    更新日期:2015-10-01 00:00:00

  • Two in One: Endovascular Treatment of Acute Tandem Occlusions in the Anterior Circulation.

    abstract:PURPOSE:Acute major stroke with high-grade stenosis or occlusion of the extracranial internal carotid artery (ICA) and additional intracranial large artery occlusion is increasingly treated with a mechanical endovascular approach by extracranial stenting and intracranial thrombectomy due to poor response to systemic th...

    journal_title:Clinical neuroradiology

    pub_type: 临床试验,杂志文章

    doi:10.1007/s00062-014-0318-2

    authors: Maurer CJ,Joachimski F,Berlis A

    更新日期:2015-12-01 00:00:00

  • Wide, short bore magnetic resonance at 1.5 t: reducing the failure rate in claustrophobic patients.

    abstract:PURPOSE:Claustrophobic reactions in patients undergoing magnetic resonance imaging (MRI) have a significant impact on the workflow, patient acceptance and ultimately the costs involved in obtaining a diagnostic scan. The purpose of this study was to determine if the use of a wide, short bore MRI scanner could reduce th...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-011-0075-4

    authors: Hunt CH,Wood CP,Lane JI,Bolster BD,Bernstein MA,Witte RJ

    更新日期:2011-09-01 00:00:00

  • Stent Retriever Thrombectomy with Mindframe Capture LP in Isolated M2 Occlusions.

    abstract:BACKGROUND AND PURPOSE:Mechanical thrombectomy is an effective recanalization technique in acute ischemic stroke patients with large vessel occlusions; however, it is unclear to what extent stent retriever thrombectomy may be applicable to occlusions of smaller peripheral cerebral vessels. The outcome of patients with ...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-018-0739-4

    authors: Dobrocky T,Bellwald S,Kurmann R,Piechowiak EI,Kaesmacher J,Mosimann PJ,Zibold F,Jung S,Arnold M,Fischer U,Gralla J,Mordasini P

    更新日期:2020-03-01 00:00:00

  • Merged Volume Rendered Flat-panel Computed Tomography for Postoperative Cochlear Implant Assessment.

    abstract:PURPOSE:Evaluation of a new postprocessing method for postoperative control of cochlear implants (CI) based on a single flat detector computed tomography (FD-CT) run and volume rendering of 3D models of the inner ear. METHODS:The FD-CT datasets of CIs were selected and postprocessed to generate both standard multiplan...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-019-00832-x

    authors: Eisenhut F,Lang S,Taha L,Doerfler A,Iro H,Hornung J

    更新日期:2020-12-01 00:00:00

  • The Past, Present and Future of Endovascular Aneurysm Treatment.

    abstract::The technology available for the endovascular treatment of intracranial aneurysms is rapidly evolving. Both current and future devices are described. This includes, among others, UNO for parent vessel occlusion, the Medina device for saccular filling, the Comaneci device for remodeling, pCONus for assisted coil occlus...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00062-015-0403-1

    authors: Henkes H,Weber W

    更新日期:2015-10-01 00:00:00

  • Value of Flat-detector Computed Tomography Angiography with Intravenous Contrast Media Injection in the Evaluation and Treatment of Acutely Ruptured Aneurysms of the AcomA complex: A Single Center Experience in 15 Cases.

    abstract:OBJECTIVE:To illustrate the added value of flat-detector computed tomography angiography with intravenous contrast media injection (intravenous FDCTA) in the evaluation of complex A1/A2/AcomA aneurysms. PATIENTS AND METHODS:We retrospectively reviewed 15 patients with ruptured aneurysms. In each patient, an intravenou...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-017-0592-x

    authors: Rösch J,Lang S,Gölitz P,Kallmünzer B,Rössler K,Doerfler A,Struffert T

    更新日期:2018-12-01 00:00:00

  • Isometric non-machine-based prevention training program: effects on the cross-sectional area of the paravertebral muscles on magnetic resonance imaging.

    abstract:PURPOSE:The purpose of this study was to determine potential effects of isometric non-machine-based training on the cross-sectional area (CSA) of the paravertebral muscles in volunteers who were participants in a prevention program. An increase in the CSA of back muscles after various machine-based exercises have been ...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-011-0104-3

    authors: Lescher S,Bender B,Eifler R,Haas F,Gruber K,Felber S

    更新日期:2011-11-01 00:00:00

  • Acute Basilar Artery Occlusion with Underlying High-Grade Basilar Artery Stenosis: Multimodal Endovascular Therapy in a Series of Seven Patients.

    abstract:PURPOSE:Acute basilar artery occlusion is associated with high rates of major morbidity and mortality. In rare cases, the underlying pathology is a high-grade stenosis of the basilar artery. We report on a series of seven cases with occluded high-grade basilar artery stenosis who received endovascular therapy at our ce...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-014-0303-9

    authors: Behme D,Weber W,Mpotsaris A

    更新日期:2015-09-01 00:00:00

  • [Middle cerebral artery infarct after aneurysm coiling].

    abstract::The report concerns a 44-year-old female patient with incidental left middle cerebral artery aneurysm. After endovascular therapy by coiling, a hemiparesis was observed following extubation. Disturbance of speech and disorientation added later. An infarct of the lenticular nucleus was found. The angiography showed an ...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-010-0007-8

    authors: Turowski B,Becker H

    更新日期:2010-06-01 00:00:00

  • Neuroradiological viewpoint on the diagnostics of space-occupying brain lesions.

    abstract::Conventional magnetic resonance (MR) imaging of space-occupying lesions may answer most of the questions concerning the diagnosis and subsequent treatment strategies if patient age, clinical and paraclinical findings are considered as well. However, crucial and relevant differential diagnoses require additional MR met...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00062-011-0073-6

    authors: Faehndrich J,Weidauer S,Pilatus U,Oszvald A,Zanella FE,Hattingen E

    更新日期:2011-09-01 00:00:00

  • Potential impact of a 32-channel receiving head coil technology on the results of a functional MRI paradigm.

    abstract:PURPOSE:The authors investigated the potential of a 32-channel (32ch) receiving head coil for functional magnetic resonance imaging (fMRI) compared to a standard eight-channel (8ch) coil using a motor task. MATERIAL AND METHODS:Brain activation was analyzed in 14 healthy right-handed subjects performing finger tapping...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-010-0029-2

    authors: Albrecht J,Burke M,Haegler K,Schöpf V,Kleemann AM,Paolini M,Wiesmann M,Linn J

    更新日期:2010-12-01 00:00:00

  • Optical Coherence Tomography as an Adjunct During Carotid Artery Stenting for Carotid Atherosclerotic Disease.

    abstract:PURPOSE:Carotid artery stenting (CAS) has been proven to decrease the risk of stroke in symptomatic patients with moderate/high-grade carotid stenosis; however, there is an increased periprocedural risk of stroke with CAS compared to carotid endarterectomy. The goal of this article is to report the utilization of endov...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-019-00799-9

    authors: Pasarikovski CR,Ramjist J,da Costa L,Black SE,Cardinell J,Yang VX

    更新日期:2020-09-01 00:00:00

  • B-Flow Sonography for Evaluation of Basal Cerebral Arteries in Newborns.

    abstract::The aim of the study was to evaluate the B‑flow sonography (BFS) to image the basal cerebral arteries in newborn infants. For this purpose 34 newborns, who underwent standardized ultrasound of the brain including BFS, color Doppler (CDS) and power Doppler (PDS) techniques were retrospectively assessed. Delineation of ...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-017-0624-6

    authors: Groth M,Ernst M,Deindl P,Herrmann J

    更新日期:2019-03-01 00:00:00

  • MR angiography at 3 Tesla to assess proximal internal carotid artery stenoses: contrast-enhanced or 3D time-of-flight MR angiography?

    abstract:PURPOSE:The aim of this study was to compare the diagnostic accuracy of 3D time-of-flight (TOF-MRA) and contrast-enhanced (CE-MRA) magnetic resonance angiography at 3 T for detection and quantification of proximal high-grade stenosis using multidetector computed tomography angiography (MDCTA) as reference standard. ME...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-013-0279-x

    authors: Weber J,Veith P,Jung B,Ihorst G,Moske-Eick O,Meckel S,Urbach H,Taschner CA

    更新日期:2015-03-01 00:00:00

  • Contrast-enhanced magnetic resonance angiography in stroke diagnostics: additional information compared with time-of-flight magnetic resonance angiography?

    abstract:PURPOSE:The aim of this study was a comparison of the diagnostic value of time-of-flight magnetic resonance angiography (TOF-MRA) and contrast-enhanced (CE) MRA in the setting of acute stroke MRI. The hypothesis was that CE-MRA has at least the same diagnostic value as the commonly used TOF-MRA. MATERIALS AND METHODS:...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-010-0039-0

    authors: Alfke K,Jensen U,Pool C,Rohr A,Brüning R,Weber J,Bartsch T,Stingele R,Jansen O

    更新日期:2011-04-01 00:00:00

  • Limbic-Auditory Interactions of Tinnitus: An Evaluation Using Diffusion Tensor Imaging.

    abstract:OBJECTIVE:Tinnitus is defined as an imaginary subjective perception in the absence of an external sound. Convergent evidence proposes that tinnitus perception includes auditory, attentional and emotional components. The aim of this study was to investigate the thalamic, auditory and limbic interactions associated with ...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-015-0473-0

    authors: Gunbey HP,Gunbey E,Aslan K,Bulut T,Unal A,Incesu L

    更新日期:2017-06-01 00:00:00

  • Computed Tomography Perfusion is a Useful Adjunct to Computed Tomography Angiography in the Diagnosis of Brain Death.

    abstract:BACKGROUND:In the diagnosis of brain death (BD), computed tomography angiography (CTA) results in some cases show intracranial filling, leading to diagnostic confusion. Because cerebral circulatory arrest commences at the capillary level, we hypothesized that computed tomography perfusion (CTP) would be a more sensitiv...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-017-0631-7

    authors: Sawicki M,Sołek-Pastuszka J,Chamier-Ciemińska K,Walecka A,Walecki J,Bohatyrewicz R

    更新日期:2019-03-01 00:00:00

  • Clinical Significance of Circumferential Aneurysmal Wall Enhancement in Symptomatic Patients with Unruptured Intracranial Aneurysms: a High-resolution MRI Study.

    abstract:BACKGROUND AND PURPOSE:The estimates on the risk of rupture of intracranial aneurysms remain a controversial topic. Circumferential aneurysmal wall enhancement (CAWE) on vessel wall magnetic resonance imaging (MRI) has been described in unstable aneurysms. Sentinel headaches and third nerve palsy are possible symptoms ...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-017-0598-4

    authors: Fu Q,Guan S,Liu C,Wang K,Cheng J

    更新日期:2018-12-01 00:00:00

  • Long-term Angiographic Results of the Low-profile Acandis Acclino Stent for Treatment of Intracranial Aneurysms : A Multicenter Study.

    abstract:PURPOSE:The low-profile Acandis Acclino is a self-expandable nitinol microstent for stent-assisted coiling of intracranial aneurysms. This article reports long-term clinical and angiographic outcome in a multicenter setting. METHODS:In this study 98 consecutive patients (mean age 55.4 ± 13.5 years) were treated with t...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-019-00847-4

    authors: Goertz L,Smyk MA,Mpotsaris A,Borggrefe J,Dorn F,Liebig T,Schlamann M,Laukamp K,Krischek B,Turowski B,Kabbasch C

    更新日期:2020-12-01 00:00:00

  • SVM-Based Normal Pressure Hydrocephalus Detection.

    abstract:BACKGROUND AND PURPOSE:As magnetic resonance imaging (MRI) signs of normal pressure hydrocephalus (NPH) may precede clinical symptoms we sought to evaluate an algorithm that automatically detects this pattern. METHODS:A support vector machine (SVM) was trained in 30 NPH patients treated with ventriculoperitoneal shunt...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-020-00993-0

    authors: Rau A,Kim S,Yang S,Reisert M,Kellner E,Duman IE,Stieltjes B,Hohenhaus M,Beck J,Urbach H,Egger K

    更新日期:2021-01-26 00:00:00

  • Evaluation of a Touchless Angiography Suite Computer Controller for Neuroendovascular Procedures.

    abstract:BACKGROUND AND PURPOSE:The GestSure system is an Food and Drugs Administration (FDA)-registered depth-sensing infrared device initially developed for touchless image navigation during open surgery. The goal of this study was to explore the feasibility of this technology with medical students, residents, fellows and sta...

    journal_title:Clinical neuroradiology

    pub_type: 杂志文章

    doi:10.1007/s00062-019-00829-6

    authors: Dmytriw AA,Phan K,Tremaine J,Strickland M,Radovanovic I,Krings T,Pereira VM

    更新日期:2019-11-06 00:00:00