Immunoglobulin G4-related periaortitis and periarteritis: CT findings in 17 patients.

Abstract:

PURPOSE:To retrospectively evaluate computed tomographic (CT) findings of immunoglobulin G4 (IgG4)-related disease involving the vascular system. MATERIALS AND METHODS:This study was approved by the institutional review board, and all patients included had consented to the use of their medical records for the purpose of research. The study consisted of 17 patients (16 men and one woman; age range, 54-86 years). CT findings of IgG4-related periarterial lesions were retrospectively analyzed. Radiopathologic correlations were examined on the basis of surgically resected specimens. RESULTS:A total of 22 periarterial lesions were detected in 17 patients. The lesions were located in the thoracic aorta (n = 4), abdominal aorta to iliac arteries (n = 13), superior mesenteric artery (n = 3), inferior mesenteric artery (n = 1), and splenic artery (n = 1). Radiologically, they were characterized by arterial wall thickening (mean thickness, 11 mm), relatively clear circumscription, possible association with luminal change (mostly dilated and rarely stenotic), exaggerated atherosclerotic change, and homogeneous enhancement at the late phase of contrast material-enhanced CT. Twelve patients (71%) had IgG4-related disease in other organs. Pathologically, diffuse lymphoplasmacytic infiltration, numerous IgG4-positive plasma cells, and irregular fibrosis were noted in the thickened arterial wall, especially at the adventitia. Steroid therapy administered to eight patients rapidly diminished the arterial wall thickening. One patient who did not receive steroid therapy showed spontaneous improvement at follow-up CT. CONCLUSION:IgG4-related arterial lesions occur mainly in the aorta and its main branches and are radiologically characterized by homogeneous arterial wall thickening corresponding to pathologic features of IgG4-related sclerosing inflammation in the adventitia.

journal_name

Radiology

journal_title

Radiology

authors

Inoue D,Zen Y,Abo H,Gabata T,Demachi H,Yoshikawa J,Miyayama S,Nakanuma Y,Matsui O

doi

10.1148/radiol.11102250

subject

Has Abstract

pub_date

2011-11-01 00:00:00

pages

625-33

issue

2

eissn

0033-8419

issn

1527-1315

pii

radiol.11102250

journal_volume

261

pub_type

杂志文章
  • Thyroid gland: US in patients with Hodgkin disease treated with radiation therapy in childhood.

    abstract::The authors retrospectively assessed with sonography the prevalence of thyroid gland abnormalities in 30 patients who underwent radiation therapy for Hodgkin disease between 1962 and 1984. Doses ranged from 3,000 to 4,500 rad (3,000-4,500 cGy). Abnormalities were found in the sonograms of 24 patients and included unil...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.172.1.2662250

    authors: Stewart RR,David CL,Eftekhari F,Ried HL,Fuller LM,Fornage BD

    更新日期:1989-07-01 00:00:00

  • Radiation dose is reduced with a single-pass whole-body multi-detector row CT trauma protocol compared with a conventional segmented method: initial experience.

    abstract::Radiation dose data were collected from a calibrated multi-detector row computed tomographic (CT) scanner during trauma CT. One protocol (used with 10 case subjects) involved a single-pass continuous whole-body acquisition from cranial vertex to symphysis pubis, while the other, conventional protocol (used with 10 con...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2293021651

    authors: Ptak T,Rhea JT,Novelline RA

    更新日期:2003-12-01 00:00:00

  • Reciprocating Bucky for serial film changers.

    abstract::A reciprocating Bucky design for serial film changers is described. It is simple to construct. Inexpensive, and enhances radiograph resolution by eliminating grid lines. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/125.1.250

    authors: Becker JA,Heiferman S

    更新日期:1977-10-01 00:00:00

  • Liver metabolite concentrations measured with 1H MR spectroscopy.

    abstract:PURPOSE:To determine the feasibility of measuring choline and glycogen concentrations in normal human liver in vivo with proton (hydrogen 1 [1H]) magnetic resonance (MR) spectroscopy. MATERIALS AND METHODS:Signed consent to participate in an institutional review board-approved and HIPAA-compliant study was obtained fr...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.12112344

    authors: Ouwerkerk R,Pettigrew RI,Gharib AM

    更新日期:2012-11-01 00:00:00

  • Xeroradiography of axillary lymph node disease.

    abstract::Xeroradiographic evaluation of the axillary lymph nodes permits differentiation of characteristic patterns, including normal nodes and those enlarged as the result of fatty infiltration, inflammation, metastases from a breast primary, or primary nodal disease such as lymphoma or hyperplasia. The author describes his e...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/115.1.67

    authors: Kalisher L

    更新日期:1975-04-01 00:00:00

  • Microwave ablation with multiple simultaneously powered small-gauge triaxial antennas: results from an in vivo swine liver model.

    abstract:PURPOSE:To prospectively investigate the ability of a single generator to power multiple small-diameter antennas and create large zones of ablation in an in vivo swine liver model. MATERIALS AND METHODS:Thirteen female domestic swine (mean weight, 70 kg) were used for the study as approved by the animal care and use c...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2441052054

    authors: Brace CL,Laeseke PF,Sampson LA,Frey TM,van der Weide DW,Lee FT Jr

    更新日期:2007-07-01 00:00:00

  • Left coronary arterial blood flow: noninvasive detection by Doppler US.

    abstract::Continuous wave (CW) and pulsed Doppler ultrasound studies with spectral analysis were used to detect the left coronary arterial blood flow in patients who were undergoing routine echocardiography. The pulmonary artery is a stable ultrasonic landmark from which detection of the blood flow can be effected. The left cor...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.159.3.3517950

    authors: Gramiak R,Holen J,Moss AJ,Gutierrez OH,Picone AL,Roe SA

    更新日期:1986-06-01 00:00:00

  • Stab wounds to the extremities: indications for angiography.

    abstract::To ascertain the sensitivity of physical examination with respect to significant arterial injury, the angiographic findings of 61 stab wounds to the extremities were correlated with specific physical findings. In 25 injuries there were physical findings of major injury, including one or more of the following: pulse de...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.162.2.3797660

    authors: Hartling RP,McGahan JP,Blaisdell FW,Lindfors KK

    更新日期:1987-02-01 00:00:00

  • Transcatheter occlusion of pulmonary arterial circulation and collateral supply: failures, incidents, and complications.

    abstract::Failures and complications were analyzed retrospectively in 45 patients treated with embolotherapy or occlusion of pulmonary arterial circulation. Pulmonary arterial branches were occluded with steel coils in 19 patients with pulmonary arteriovenous malformations, 17 with hemoptysis of pulmonary artery (PA) origin, an...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.180.3.1871280

    authors: Remy-Jardin M,Wattinne L,Remy J

    更新日期:1991-09-01 00:00:00

  • Xeroradiography of the thyroid.

    abstract::In a study of 726 patients, xeroradiography of the thyroid using a modified oblique projection was found to be superior to conventional soft-tissue radiography in detecting calcification in thyroid tumors because of edge enhancement. This facilitated a diagnosis of carcinoma in 75% of 68 primary tumors and 55% of 33 r...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.141.2.7291570

    authors: Kasai N,Tsuya A

    更新日期:1981-11-01 00:00:00

  • Quantitative CT indexes in idiopathic pulmonary fibrosis: relationship with physiologic impairment.

    abstract:PURPOSE:To determine whether measurements of skewness, kurtosis, and mean lung attenuation on thin-section computed tomographic (CT) histograms in patients with idiopathic pulmonary fibrosis (IPF) correlate with pulmonary physiologic abnormality in a nonspirometrically controlled multicenter study. MATERIALS AND METHO...

    journal_title:Radiology

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1148/radiol.2282020274

    authors: Best AC,Lynch AM,Bozic CM,Miller D,Grunwald GK,Lynch DA

    更新日期:2003-08-01 00:00:00

  • Assessing radiologist performance using combined digital mammography and breast tomosynthesis compared with digital mammography alone: results of a multicenter, multireader trial.

    abstract:PURPOSE:To compare radiologists' diagnostic accuracy and recall rates for breast tomosynthesis combined with digital mammography versus digital mammography alone. MATERIALS AND METHODS:Institutional review board approval was obtained at each accruing institution. Participating women gave written informed consent. Medi...

    journal_title:Radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1148/radiol.12120674

    authors: Rafferty EA,Park JM,Philpotts LE,Poplack SP,Sumkin JH,Halpern EF,Niklason LT

    更新日期:2013-01-01 00:00:00

  • Rotator cuff disruption: diagnosis with digital arthrography.

    abstract::Shoulder arthrography is a reliable technique for use in the diagnosis of tears of the rotator cuff, although delineation of the precise site and size of tears requires meticulous double-contrast technique and considerable examiner expertise. The authors initiated a prospective evaluation of digital arthrography of th...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.168.3.3406400

    authors: Stiles RG,Resnick D,Sartoris DJ,Andre MP

    更新日期:1988-09-01 00:00:00

  • Duplex ultrasound imaging: vascular applications.

    abstract::A recently developed duplex ultrasonic imaging system that combines high-resolution real-time imaging with simultaneous Doppler analysis provides accurate evaluation of hemodynamically significant occlusive vascular lesions. This system was used in the evaluation of the extracranial carotid arteries, iliofemoral arter...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.150.2.6691110

    authors: Wetzner SM,Kiser LC,Bezreh JS

    更新日期:1984-02-01 00:00:00

  • MR-guided percutaneous intramyocardial injection with an MR-compatible catheter: feasibility and changes in T1 values after injection of extracellular contrast medium in pigs.

    abstract:PURPOSE:To assess the feasibility of percutaneous magnetic resonance (MR)-guided intramyocardial injection of gadodiamide by using real-time imaging and to quantify T1 values and the size of the enhanced region for different concentrations of contrast agent for 30 minutes after injection. MATERIALS AND METHODS:Animal ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2352031760

    authors: Krombach GA,Pfeffer JG,Kinzel S,Katoh M,Günther RW,Buecker A

    更新日期:2005-05-01 00:00:00

  • Diagnostic ultrasound: effects on the DNA and growth patterns of animal cells.

    abstract::The effects of diagnostic levels of ultrasound on DNA of HeLa cells included: increased immunoreactivity to antinucleoside antibodies in G1 cells, strongly suggestive of unwinding of the helix or single-strand break induction, and low levels of non-semiconservative synthesis in logarithmically growing cells treated wi...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/131.1.177

    authors: Liebeskind D,Bases R,Elequin F,Neubort S,Leifer R,Goldberg R,Koenigsberg M

    更新日期:1979-04-01 00:00:00

  • R2 and R2* mapping for sensing cell-bound superparamagnetic nanoparticles: in vitro and murine in vivo testing.

    abstract:PURPOSE:To prospectively determine the cellular iron uptake by using R2 and R2* mapping with multiecho readout gradient-echo and spin-echo sequences. MATERIALS AND METHODS:All experiments were approved by the institutional animal care committee. Lung carcinoma cells were lipofected with superparamagnetic iron oxides (...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2451061345

    authors: Kuhlpeter R,Dahnke H,Matuszewski L,Persigehl T,von Wallbrunn A,Allkemper T,Heindel WL,Schaeffter T,Bremer C

    更新日期:2007-11-01 00:00:00

  • Color Doppler US in the evaluation of acute scrotal disease.

    abstract::Twenty-seven patients presented with painful acute scrotal swelling. After a clinical impression was established, all patients underwent diagnostic imaging with color Doppler ultrasound (US). Seven patients underwent surgical exploration for testicular torsion diagnosed with color Doppler US (100% operative confirmati...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.176.2.2195590

    authors: Lerner RM,Mevorach RA,Hulbert WC,Rabinowitz R

    更新日期:1990-08-01 00:00:00

  • Gastrostomy and gastrojejunostomy tube placements: outcomes in children with gastroschisis, omphalocele, and congenital diaphragmatic hernia.

    abstract:PURPOSE:To retrospectively evaluate the technical success, safety, and outcomes of radiologically guided retrograde percutaneous gastrostomy and gastrojejunostomy tube placements in terms of weight gain and growth in children with gastroschisis, omphalocele, and/or congenital diaphragmatic hernia (CDH). MATERIALS AND ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2481061193

    authors: Rosenberg J,Amaral JG,Sklar CM,Connolly BL,Temple MJ,John P,Chait PG

    更新日期:2008-07-01 00:00:00

  • Retrievable vena caval filter percutaneously introduced.

    abstract::A vena caval filter than can be introduced percutaneously via the femoral vein is described. We placed these filters in five patients without complications. Experimental work in filter removal one to two weeks after insertion in dogs has been performed. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.155.3.4001390

    authors: Lund G,Rysavy J,Hunter DW,Castaneda-Zuniga WR,Amplatz K

    更新日期:1985-06-01 00:00:00

  • Case 253: Thrombosed Umbilical Venous Varix in an Infant.

    abstract::History A 3-month-old previously healthy girl presented to an outside institution with a 4-day history of low-grade fever, irritability, and a tender "knot" in the upper abdomen. Ultrasonography (US) was performed at an outside hospital. US images were not available for review; however, they showed a mass in the left ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2018160106

    authors: Sandberg JK,Hulett-Bowling R,Khanna G

    更新日期:2018-05-01 00:00:00

  • Gallium scanning as a screening test for inflammatory lesions.

    abstract::Of the 67-Ga scans obtained in 42 patients with fever and suspected inflammatory lesions, 17 were positive. In 9 patients the scans yielded information about localized inflammation not provided by previous studies. Four patients did not have an inflammatory lesion at the positive site. Ten of 13 abscesses or inflamed ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/116.2.383

    authors: Teates CD,Hunter JG Jr

    更新日期:1975-08-01 00:00:00

  • Computers in radiology. A question of compatibility.

    abstract::Given the increasing diversification of computers in most areas of radiology, the ability to solve problems resulting from incompatibility between systems is becoming essential. Manufacturers should supply hardware and software documentation to allow connections between different systems and give the radiology departm...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.139.2.7220900

    authors: Ackerman LV

    更新日期:1981-05-01 00:00:00

  • Detection of single and multiple targets in tissue phantoms with fluorescence-enhanced optical imaging: feasibility study.

    abstract:PURPOSE:To evaluate the feasibility of reconstructing single and multiple targets by using fluorescence-enhanced tomography of a breast tissue phantom. MATERIALS AND METHODS:Frequency-domain fluorescence measurements were performed in cup-shaped tissue phantoms of clinically relevant size (diameter, 10 cm) in which si...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2343031725

    authors: Godavarty A,Eppstein MJ,Zhang C,Sevick-Muraca EM

    更新日期:2005-04-01 00:00:00

  • Percutaneous cholecystostomy in acute cholecystitis and common duct obstruction.

    abstract::Percutaneous cholecystostomy was performed in 36 patients, of whom 22 patients with acute cholecystitis had decompression of the gallbladder and 14 patients with common duct obstruction had biliary decompression through the gallbladder. In almost all cases of acute cholecystitis, percutaneous cholecystostomy quickly c...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.152.2.6739800

    authors: Pearse DM,Hawkins IF Jr,Shaver R,Vogel S

    更新日期:1984-08-01 00:00:00

  • Predicting Retear after Repair of Full-Thickness Rotator Cuff Tear: Two-Point Dixon MR Imaging Quantification of Fatty Muscle Degeneration-Initial Experience with 1-year Follow-up.

    abstract::Purpose To determine the degree of preoperative fatty degeneration within muscles, postoperative longitudinal changes in fatty degeneration, and differences in fatty degeneration between patients with full-thickness supraspinatus tears who do and those who do not experience a retear after surgery. Materials and Method...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2016151789

    authors: Nozaki T,Tasaki A,Horiuchi S,Ochi J,Starkey J,Hara T,Saida Y,Yoshioka H

    更新日期:2016-08-01 00:00:00

  • Hyperparathyroidism in high-risk surgical patients: evaluation with double-phase technetium-99m sestamibi imaging.

    abstract:PURPOSE:To evaluate the accuracy of technetium-99m sestamibi as a single agent in the detection and localization of hyperfunctioning parathyroid tissue in patients who underwent prior neck exploration or who otherwise are high surgical risks. MATERIALS AND METHODS:Thirty-nine patients with hyperparathyroidism underwen...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.197.3.7480730

    authors: Lee VS,Wilkinson RH Jr,Leight GS Jr,Coogan AC,Coleman RE

    更新日期:1995-12-01 00:00:00

  • Bronchial collapsibility at forced expiration in healthy volunteers: assessment with multidetector CT.

    abstract:PURPOSE:To assess forced-expiratory bronchial collapsibility in healthy volunteers by using multidetector computed tomography (CT) and to compare the results with the current diagnostic criterion for bronchomalacia. MATERIALS AND METHODS:The institutional review board approved this HIPAA-compliant study. Following inf...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.10100219

    authors: Litmanovich D,O'Donnell CR,Bankier AA,Ernst A,Millett ME,Loring SH,Boiselle PM

    更新日期:2010-11-01 00:00:00

  • Clinical comparison of small-and large-caliber cutting needles for biopsy.

    abstract::A 22 gauge "skinny core" (Madayag) biopsy needle, an 18 gauge Menghini needle, and a 14 gauge Tru-cut needle were compared in 51 patients. The Madayag needle was found to have a high recovery rate and provided adequate histological information in a large percentage of cases. However, the larger needles more consistent...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.146.3.6828680

    authors: Haaga JR,LiPuma JP,Bryan PJ,Balsara VJ,Cohen AM

    更新日期:1983-03-01 00:00:00

  • Esophagogastric neoplasms: palliation with a modified gianturco stent.

    abstract::Self-expanding metallic stents of a modified Gianturco design were used for palliative treatment of malignant esophagogastric strictures. Over a 10-month period, 10 stents were placed in nine patients. All patients with severe dysphagia due to malignant strictures in whom all other treatment options had failed were ca...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.180.2.1712500

    authors: Song HY,Choi KC,Cho BH,Ahn DS,Kim KS

    更新日期:1991-08-01 00:00:00