Partially Melted Ti6Al4V Particles Increase Bacterial Adhesion and Inhibit Osteogenic Activity on 3D-printed Implants: An In Vitro Study.

Abstract:

BACKGROUND:A porous Ti6Al4V implant that is manufactured using selective laser melting (SLM) has broad potential applications in the field of orthopaedic implants. The pore structure of the SLM porous Ti6Al4V implant allows for cell migration and osteogenic differentiation, which is favorable for bone ingrowth and osseointegration. However, it is unclear whether the pore structure and partially melted Ti6Al4V particles on a SLM porous Ti6Al4V implant will increase bacterial adhesion and, perhaps, the risk of implant-related infection. QUESTIONS/PURPOSES:(1) Is there more bacterial adhesion and colonization on SLM porous Ti6Al4V implants than on polished orthopaedic implants? (2) Do partially melted Ti6Al4V particles on SLM porous Ti6Al4V implants reduce human bone mesenchymal stem cells (hBMSCs) adhesion, viability, and activity? METHODS:To determine bacterial adhesion and biofilm formation, we incubated five different Ti6Al4V discs (polished, grit-blasted, plasma-sprayed, particle SLM porous, and nonparticle SLM porous discs) with methicillin-resistant Staphylococcus aureus (MRSA) and Escherichia coli. Bacterial coverage on the surface of the five different Ti6Al4V discs were evaluated based on scanning electron microscopy (SEM) images quantitatively. In addition, a spread-plate method was used to quantitatively evaluate the bacterial adhesion on those implants. The biofilm formation was stained with crystal violet and semi-quantitatively determined with a microplate reader. The morphology and adhesion of hBMSCs on the five Ti6Al4V discs were observed with SEM. The cell viability was quantitatively evaluated with a Cell Counting Kit-8 assay. In addition, the osteogenic activity was determined in vitro with a quantitatively alkaline phosphatase activity assay and alizarin-red staining. For semiquantitative analysis, the alizarin-red stained mineralized nodules were dissolved and determined with a microplate reader. RESULTS:The polished discs had the lowest MRSA adhesion (8.3% ± 2.6%) compared with grit-blasted (19.1% ± 3.9%; p = 0.006), plasma-sprayed (38.5% ± 5.3%; p < 0.001), particle (23.1% ± 2.8%; p < 0.001), and nonparticle discs (15.7% ± 2.5%; p = 0.003). Additionally, when comparing the two SLM discs, we found that particle discs had higher bacterial coverage than nonparticle discs (23.1% ± 2.8% versus 15.7% ± 2.5%; p = 0.020). An E. coli analysis showed similar results, with the higher adhesion to particle SLM discs than to nonparticle discs (20.7% ± 4.2% versus 14.4% ± 3.6%; p = 0.011). In addition, on particle SLM porous discs, bacterial colonies were localized around the partially melted Ti6Al4V particles, based on SEM images. After a 7-day incubation period, the cell viability in the particle group (optical density value 0.72 ± 0.05) was lower than that in the nonparticle groups (optical density value: 0.87 ± 0.08; p = 0.003). Alkaline phosphatase activity, as a marker of osteogenic differentiation, was lower in the particle group than in the nonparticle group (1.32 ± 0.12 U/mL versus 1.58 ± 0.09 U/mL; p = 0.012). CONCLUSION:Higher bacterial adhesion was observed on SLM porous discs than on polished discs. The partially melted Ti6Al4V particles on SLM porous discs not only enhanced bacterial adhesion but also inhibited the osteogenic activity of hBMSCs. Postprocessing treatment is necessary to remove partially melted Ti6Al4V particles on an SLM implant before further use. Additional studies are needed to determine whether an SLM porous Ti6Al4V implant increases the risk of implant-related infection in vivo. CLINICAL RELEVANCE:As implants with porous Ti6Al4V made using SLM are being designed, our preliminary findings suggest that postprocessing treatment is needed to remove partially melted Ti6Al4V particles before further use. In addition, the depth of the porous structure of the SLM implant should not exceed the maximum depth of bone ingrowth because the host immune defense cannot prevent bacterial adhesion without integration.

journal_name

Clin Orthop Relat Res

authors

Xie K,Guo Y,Zhao S,Wang L,Wu J,Tan J,Yang Y,Wu W,Jiang W,Hao Y

doi

10.1097/CORR.0000000000000954

subject

Has Abstract

pub_date

2019-12-01 00:00:00

pages

2772-2782

issue

12

eissn

0009-921X

issn

1528-1132

pii

00003086-201912000-00031

journal_volume

477

pub_type

杂志文章
  • An evaluation of the mechanical failure modalities of a rotating hinge knee prosthesis.

    abstract::The clinical and metallurgical performance of 12 retrieved Noiles total knee prostheses was investigated. Clinical histories and serial roentgenograms were used in conjunction with the American Society for Testing and Materials (ASTM) standard implant retrieval and analysis techniques to assess device performance. All...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:

    authors: Kester MA,Cook SD,Harding AF,Rodriguez RP,Pipkin CS

    更新日期:1988-03-01 00:00:00

  • Mechanical properties of perforated and partially demineralized bone grafts.

    abstract::Changes in flexural rigidity and compression strength of 18 sheep tibias were investigated after laser perforation and partial demineralization. Test bones were divided into three groups: Group 1, no treatment; Group 2, laser hole grid; and Group 3, laser hole grid and partial demineralization. Starting in the anterio...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1097/00003086-199808000-00028

    authors: Lewandrowski KU,Bonassar L,Uhthoff HK

    更新日期:1998-08-01 00:00:00

  • An unusual case of primary osteosarcoma of the talus.

    abstract::An osteosarcoma of the talus occurred in a 21-year-old man. The tumor had been mistaken for a fibrosarcoma, but its osteogenic nature was demonstrated by multiple sectioning of the entire talus. Nineteen months after amputation the patient died from pulmonary metastases. Osteosarcoma in the talus seems not to have bee...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:

    authors: Amini M,Colacecchi C

    更新日期:1980-07-01 00:00:00

  • Femoral revision with impaction grafting and a collarless, polished, tapered stem.

    abstract::Femoral impaction allografting has been done with and without variations of the original description. The purpose of this study was to review Harris hip scores, radiographs, and complications in patients in whom we used the original technique without significant modifications. Preoperative and postoperative hip scores...

    journal_title:Clinical orthopaedics and related research

    pub_type: 临床试验,杂志文章

    doi:10.1097/01.blo.0000150320.73465.82

    authors: Mahoney CR,Fehringer EV,Kopjar B,Garvin KL

    更新日期:2005-03-01 00:00:00

  • Surgical technique: Tscherne-Johnson extensile approach for tibial plateau fractures.

    abstract:BACKGROUND:The standard approach to lateral tibial plateau fractures involves elevation of the iliotibial band (IT) and anterior tibialis origin in continuity from Gerdy's tubercle and metaphyseal flare. We describe an alternative approach to increase lateral plateau joint exposure and maintain iliotibial band insertio...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1007/s11999-013-2962-2

    authors: Johnson EE,Timon S,Osuji C

    更新日期:2013-09-01 00:00:00

  • Bone marrow aspirate concentrate and platelet-rich plasma enhanced bone healing in distraction osteogenesis of the tibia.

    abstract:BACKGROUND:During lower limb lengthening, poor bone regeneration is a devastating complication. Several local or systemic applications have been used to promote osteogenesis, and biologic stimulations are gaining attention, but their utility has not been proven in this setting. QUESTIONS/PURPOSES:In patients undergoin...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s11999-014-3548-3

    authors: Lee DH,Ryu KJ,Kim JW,Kang KC,Choi YR

    更新日期:2014-12-01 00:00:00

  • Is a cementless dual mobility socket in primary THA a reasonable option?

    abstract:BACKGROUND:Dislocation after THA continues to be relatively common. Dual mobility sockets have been associated with low dislocation rates, but it remains unclear whether their use in primary THA would not introduce additional complications. QUESTIONS/PURPOSES:We therefore asked whether a current cementless dual mobili...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1007/s11999-012-2395-3

    authors: Hamadouche M,Arnould H,Bouxin B

    更新日期:2012-11-01 00:00:00

  • Results of cementless revisions of total hip arthroplasties using the Harris-Galante prosthesis.

    abstract::Sixty patients were treated with Harris-Galante prosthesis for failed, nonseptic, cemented total hip arthroplasties. The minimum follow-up period was 12 months, although 23 patients were followed for two or more years. Acetabular bone grafting was done in 86% and femoral bone grafting in 57% of the patients. The avera...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:

    authors: Harris WH,Krushell RJ,Galante JO

    更新日期:1988-10-01 00:00:00

  • Induction of osteoarthrosis in the rabbit knee joint: biochemical studies on the articular cartilage.

    abstract::Measurements of uptake in vivo of 3H-proline into 3H-hydroxyproline demonstrate that cartilage surfaces in rabbit knees with surgically induced osteoarthrosis (up to 3 months after operation) incorporated 2 to 5 times more activity into collagen than cartilage of control knees. The high uptake indicates that collagen ...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:

    authors: Floman Y,Eyre DR,Glimcher MJ

    更新日期:1980-03-01 00:00:00

  • Intraoperative cartilage degeneration predicts outcome 12 months after hip arthroscopy.

    abstract:BACKGROUND:When considering arthroscopic surgery for treatment of hip pain, it is important to understand the influence of joint degeneration on the likelihood of success. Previous research has shown poorer outcomes among patients with osteoarthritis but new arthroscopic techniques including femoroacetabular impingemen...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1007/s11999-012-2594-y

    authors: Egerton T,Hinman RS,Takla A,Bennell KL,O'Donnell J

    更新日期:2013-02-01 00:00:00

  • A comparison of patients treated by chymopapain and laminectomy for low back pain using a multidimensional pain scale.

    abstract::Seventy-seven patients treated by chymopapain and laminectomy were compared before, and 6 and 14 weeks after, treatment. A standardized, multidimensional scale of low back pain providing scores on 7 independent dimensions of sensory and affective discomfort and one measure of intensity were used. Fourteen weeks after ...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:

    authors: Leavitt F,Garron DC,Whisler WW,D'Angelo CM

    更新日期:1980-01-01 00:00:00

  • Treatment of the femoral neck amd trochanteric benign lesions.

    abstract::Thirty-five patients with a benign lesion of the femoral neck or trochanter were treated and seen in followup at the authors' institution from 1988 to 1991. Sixteen men and 19 women between the ages of 18 and 54 years (average, 27 years) were seen at an average followup of 3 years 6 months (range, 2-5 years). Eight pa...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1097/00003086-199607000-00034

    authors: Shih HN,Cheng CY,Chen YJ,Huang TJ,Hsu RW

    更新日期:1996-07-01 00:00:00

  • High cup angle and microseparation increase the wear of hip surface replacements.

    abstract::High wear rates and high patient ion levels have been associated with high (> 55 degrees) cup inclination angles for metal-on-metal surface replacements. Wear rates and patterns have been simulated for ceramic-on-ceramic bearings by applying microseparation to replicate head offset deficiency. We tested 39-mm metal-on...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1007/s11999-009-0830-x

    authors: Leslie IJ,Williams S,Isaac G,Ingham E,Fisher J

    更新日期:2009-09-01 00:00:00

  • Reconstruction of the posterior cruciate ligament using the semimembranosus tendon.

    abstract::The semimembranosus tendon was successfully used as a posterior cruciate ligament substitute in a 27-year-old man who sustained an isolated tear of the ligament. Two years after the operation, he has no feeling of instability, and has normal hamstring strength, power, and endurance as tested on the Cybex II dynamomete...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:

    authors: Southmayd WW,Rubin BD

    更新日期:1980-07-01 00:00:00

  • Joint injury, repair, and remodeling: roles in post-traumatic osteoarthritis.

    abstract::Joint injuries, especially intraarticular fractures, frequently lead to progressive joint degeneration that causes the clinical syndrome of posttraumatic osteoarthritis. Orthopaedists try to prevent this disease by attempting to restore joint congruity, alignment, and stability; however, many patients have crippling j...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章,评审

    doi:

    authors: Buckwalter JA,Brown TD

    更新日期:2004-06-01 00:00:00

  • Treatment of chronic heel pain by surgical release of the first branch of the lateral plantar nerve.

    abstract::Sixty-nine heels (53 patients) with chronic heel pain had a surgical release of the first branch of the lateral plantar nerve. The average duration of heel-pain symptoms was 23 months (range, six months to eight years). No patient had less than six months of conservative treatment before surgery. The average duration ...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:

    authors: Baxter DE,Pfeffer GB

    更新日期:1992-06-01 00:00:00

  • Is it necessary to cement the tibial stem in cemented total knee arthroplasty?

    abstract::An in vitro study was performed using a singular unibody design CoCr tibial baseplate with fins to test the hypothesis that the addition of cement surrounding the tibial stem decreases micromotion of the tibial tray in cemented total knee arthroplasty. Five configurations were tested. Significant micromotion occurred ...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1097/00003086-199811000-00012

    authors: Bert JM,McShane M

    更新日期:1998-11-01 00:00:00

  • Influenza Vaccination Is Not Associated with Increased Number of Visits for Shoulder Pain.

    abstract:BACKGROUND:Shoulder injury from vaccination was approved for automatic compensation from the Vaccine Injury Compensation Program (VICP)-a federal government program started in 1988 to shield the manufacturers of childhood vaccines from liability. The approval was made on the basis of case reports rather than experiment...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1097/CORR.0000000000001215

    authors: Gonzalez AI,Kortlever JTP,Moore MG,Ring DC

    更新日期:2020-10-01 00:00:00

  • The John Charnley Award: Metal-on-metal hip resurfacing versus large-diameter head metal-on-metal total hip arthroplasty: a randomized clinical trial.

    abstract:UNLABELLED:Resurfacing arthroplasty has become an attractive option for young patients who want to maintain a high activity level. One recent study reported modestly increased activity levels for patients with resurfacing compared to standard total hip arthroplasty (THA). We conducted a prospective randomized clinical ...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s11999-009-1029-x

    authors: Garbuz DS,Tanzer M,Greidanus NV,Masri BA,Duncan CP

    更新日期:2010-02-01 00:00:00

  • Unicompartmental knee arthroplasty. Ten- to 13-year follow-up study.

    abstract::In the past decade, two concepts have caused considerable controversy in orthopedic surgery of the knee. Some orthopedic centers contend that osteotomy of the tibia is the procedure of choice for unicompartmental gonarthrosis of the knee and resist the concept of unicompartmental arthroplasty. The other concept is tha...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:

    authors: Marmor L

    更新日期:1988-01-01 00:00:00

  • Natural polyphenols enhance stability of crosslinked UHMWPE for joint implants.

    abstract:BACKGROUND:Radiation-crosslinked UHMWPE has been used for joint implants since the 1990s. Postirradiation remelting enhances oxidative stability, but with some loss in strength and toughness. Vitamin E-stabilized crosslinked UHMWPE has shown improved strength and stability as compared with irradiated and remelted UHMWP...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1007/s11999-014-3850-0

    authors: Shen J,Gao G,Liu X,Fu J

    更新日期:2015-03-01 00:00:00

  • Vitamin D deficiency rickets. A report on three cases.

    abstract::A resurgence of classic vitamin D deficiency rickets has been noted in the recent pediatric literature, but no mention of it appears in recent orthopedic journals. Three cases of vitamin D deficiency rickets occurred in children whose ages ranged from 14 to 17 months. Similar to the experience of others, all three occ...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:

    authors: Kruger DM,Lyne ED,Kleerekoper M

    更新日期:1987-11-01 00:00:00

  • Effects of high-molecular-weight sodium hyaluronate on experimental osteoarthrosis induced by the resection of rabbit anterior cruciate ligament.

    abstract::Sodium hyaluronate (HA) with a molecular weight of 202 x 10(4) (HA-202) was administered into the right knees of mature rabbits for the treatment of experimental osteoarthrosis induced by resection of the anterior cruciate ligament. At six and 12 weeks after the initiation of administration, the test group was compare...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:

    authors: Yoshimi T,Kikuchi T,Obara T,Yamaguchi T,Sakakibara Y,Itoh H,Iwata H,Miura T

    更新日期:1994-01-01 00:00:00

  • Plastic femoral deformity in a 9-year-old Boy.

    abstract::We report the case of a 9-year-old boy who sustained a closed middiaphyseal plastic femoral deformation after a motor vehicle accident. The patient was treated nonoperatively with protected weightbearing to the involved extremity. Although he showed symptomatic improvement at early and intermediate followups, the pati...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1097/BLO.0b013e3181342851

    authors: Lavery MR,Huang M,Amendola A

    更新日期:2007-09-01 00:00:00

  • Screw home motion after total knee replacement.

    abstract::The objective of this study was to evaluate the effect of muscle force and the posterior cruciate ligament on screw home motion in patients with total knee replacement in a posterior cruciate ligament retaining prosthesis (10 knees) and a posterior cruciate ligament substituting prosthesis (10 knees). Screw home motio...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:

    authors: Ishii Y,Terajima K,Koga Y,Bechtold JE

    更新日期:1999-01-01 00:00:00

  • Growth plate matrix vesicle biogenesis. The role of intracellular calcium.

    abstract::Isolated bovine growth plate chondrocytes suspended in a synthetic cartilage buffer containing 10(-7) to 10(-3) M concentrations of calcium were treated with 1 microM ionomycin to induce changes in intracellular ionized calcium as measured by Fura-2 fluorescence. An increase in intracellular calcium of 10(-6) to 10(-4...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:

    authors: Iannotti JP,Naidu S,Noguchi Y,Hunt RM,Brighton CT

    更新日期:1994-09-01 00:00:00

  • Nonoperative versus operative treatment for thoracolumbar burst fractures without neurologic deficit: a meta-analysis.

    abstract:BACKGROUND:Decision-making regarding nonoperative versus operative treatment of patients with thoracolumbar burst fractures in the absence of neurologic deficits is controversial. Lack of evidence-based practice may result in patients being treated inappropriately and being exposed to unnecessary adverse consequences. ...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章,meta分析,评审

    doi:10.1007/s11999-011-2157-7

    authors: Gnanenthiran SR,Adie S,Harris IA

    更新日期:2012-02-01 00:00:00

  • Internal fixation of radial neck fracture in a fracture dislocation of the elbow. A case report.

    abstract::A 27-year-old manual laborer presented with dislocation of the right elbow, complete separation of the radial head at the neck level, and avulsion of the coronoid process. Closed reduction of the elbow resulted in ulnohumeral instability. As an alternative to silastic implant, the radial head was reduced, internally f...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:

    authors: Ebraheim NA,Skie MC,Zeiss J,Saddemi SR,Jackson WT

    更新日期:1992-03-01 00:00:00

  • N-acetylcysteine protects striated muscle in a model of compartment syndrome.

    abstract:BACKGROUND:To avoid ischemic necrosis, compartment syndrome is a surgical emergency treated with decompression once identified. A potentially lethal, oxidant-driven reperfusion injury occurs after decompression. N-acetylcysteine is an antioxidant with the potential to attenuate the reperfusion injury. QUESTIONS/PURPOS...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:10.1007/s11999-010-1287-7

    authors: Kearns SR,O'Briain DE,Sheehan KM,Kelly C,Bouchier-Hayes D

    更新日期:2010-08-01 00:00:00

  • Surgical treatment of lesions of the long head of the biceps.

    abstract::A follow-up study was carried out on 20 patients with a Hitchcock type of biceps tenodesis performed during the past seven years at the Hospital for Special Surgery. Thirteen cases were diagnosed as biceps tendinitis and seven as biceps instability. At follow-up, there was a 30% failure rate; the failures were related...

    journal_title:Clinical orthopaedics and related research

    pub_type: 杂志文章

    doi:

    authors: Dines D,Warren RF,Inglis AE

    更新日期:1982-04-01 00:00:00