Diagnostic efficacy and safety of ultrasound-guided kidney transplant biopsy using cortex-only view: a retrospective single-center study.

Abstract:

PURPOSE:Cortical biopsy is the cornerstone to reveal a cause of unexplained dysfunction of the kidney transplant. Nevertheless, only a few studies have reported the biopsy technique with its performance. We described a novel technique of ultrasound (US)-guided kidney transplant biopsy using cortex-only view and analyzed its diagnostic efficacy and safety. MATERIALS AND METHODS:Between January 2014 and December 2016, a consecutive series of 188 patients who underwent US-guided kidney transplant biopsy using cortex-only view by an experienced radiologist were evaluated (mean age, 46.1 ± 12.5 years; range, 21-79 years). Biopsy time, biopsy distance, biopsy core number, and glomerular number per patient were recorded. Successful biopsy (e.g., adequate, 10 or more glomeruli; marginal, 7-9 glomeruli) and complication rates were investigated, using Banff criteria and Clavien-Dindo classification, respectively. RESULTS:Mean biopsy time, distance, and core number were 20.6 ± 6.7 min (range, 10-44 min), 3.2 ± 0.7 cm (range, 2.1-5.4 cm), and 1.9 ± 0.3 (range, 1.0-3.0), respectively. Mean glomerular number per patient was 20.4 ± 10.0 (range, 0-54). Adequate and marginal biopsy rates were 87.2% (164/188) and 95.2% (179/188), respectively. There was no major complication requiring treatment (no patient with Clavien-Dindo grade 2 or greater complication), while there were self-limiting minor complications in 5 patients (overall complication rate, 2.7%). CONCLUSION:US-guided biopsy using cortex-only view is feasible and safe in sampling cortical tissues of kidney transplant. KEY POINTS:• Ultrasound (US)-guided kidney transplant biopsy using cortex-only view is feasible and safe. • Adequate and marginal biopsy rates were 87.2% and 95.2%, respectively. • No major complication requiring treatment occurred after biopsy.

journal_name

Eur Radiol

journal_title

European radiology

authors

Shin J,Park SY

doi

10.1007/s00330-018-5910-4

subject

Has Abstract

pub_date

2019-10-01 00:00:00

pages

5272-5279

issue

10

eissn

0938-7994

issn

1432-1084

pii

10.1007/s00330-018-5910-4

journal_volume

29

pub_type

杂志文章
  • Quantitative multivoxel 1H MR spectroscopy of the brain in children with acute liver failure.

    abstract::Acute liver failure (ALF)-related encephalopathy was previously characterized by MR spectroscopy of single voxels containing both grey and white matter brain tissue. Quantitative multivoxel MRS was used here to compare grey and white matter brain tissue concentrations of glutamate/glutamine (Glx) and lactate in ALF an...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-008-1049-z

    authors: Sijens PE,Alkefaji H,Lunsing RJ,van Spronsen FJ,Meiners LC,Oudkerk M,Verkade HJ

    更新日期:2008-11-01 00:00:00

  • CT-guided core-needle biopsy in the diagnosis of mediastinal lymphoma.

    abstract::The advent of radiologic guidance techniques for percutaneous biopsy has changed the approach to the routine diagnosis of mediastinal lymphoma. The aim of the present study was to evaluate the diagnostic accuracy of CT-guided percutaneous core-needle biopsy (PCNB) in the clinical management of patients with mediastina...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050991

    authors: Sklair-Levy M,Polliack A,Shaham D,Applbaum YH,Gillis S,Ben-Yehuda D,Sherman Y,Libson E

    更新日期:2000-01-01 00:00:00

  • Contrast-enhanced cone beam breast CT features of breast cancers: correlation with immunohistochemical receptors and molecular subtypes.

    abstract:OBJECTIVES:To investigate the association of contrast-enhanced cone beam breast CT (CE-CBBCT) features, immunohistochemical (IHC) receptors, and molecular subtypes in breast cancer. METHODS:In this retrospective study, patients who underwent preoperative CE-CBBCT and received complete IHC results were analyzed. CE-CBB...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-07277-8

    authors: Ma Y,Liu A,O'Connell AM,Zhu Y,Li H,Han P,Yin L,Lu H,Ye Z

    更新日期:2020-10-02 00:00:00

  • Triple-negative breast cancer: correlation between imaging and pathological findings.

    abstract:OBJECTIVE:This study was designed to investigate the mammography and ultrasound findings of triple-negative breast cancer and to compare the results with characteristics of ER-positive/PR-negative/HER2-negative breast cancer and ER-negative/PR-negative/HER2-positive breast cancer. METHODS:From January 2007 to October ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-009-1656-3

    authors: Ko ES,Lee BH,Kim HA,Noh WC,Kim MS,Lee SA

    更新日期:2010-05-01 00:00:00

  • Multislice computed tomography perfusion imaging for visualization of acute pulmonary embolism: animal experience.

    abstract::The purpose of our animal study was to evaluate a new computed tomography (CT) subtraction technique for visualization of perfusion defects within the lung parenchyma in subsegmental pulmonary embolism (PE). Seven healthy pigs were entered into a prospective trial. Acute PE was artificially induced by fresh clot mater...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-005-2718-9

    authors: Wildberger JE,Klotz E,Ditt H,Spüntrup E,Mahnken AH,Günther RW

    更新日期:2005-07-01 00:00:00

  • Triple rule-out CT in the emergency department: protocols and spectrum of imaging findings.

    abstract::Triage decisions in patients suffering from acute chest pain remain a challenge. The patient's history, initial cardiac enzyme levels, or initial electrocardiograms (ECG) often do not allow selecting the patients in whom further tests are needed. Numerous vascular and non-vascular chest problems, such as pulmonary emb...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-008-1231-3

    authors: Frauenfelder T,Appenzeller P,Karlo C,Scheffel H,Desbiolles L,Stolzmann P,Marincek B,Alkadhi H,Schertler T

    更新日期:2009-04-01 00:00:00

  • Validation of the Ottawa knee rules in an emergency teaching centre.

    abstract::Our objective was to determine the value of the Ottawa knee rules when applied by users with different levels of clinical training. We used a prospective patient survey by the medical students and surgery residents of a European university trauma centre. The study group consisted of 261 eligible patients who presented...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-001-1198-9

    authors: Ketelslegers E,Collard X,Vande Berg B,Danse E,El-Gariani A,Poilvache P,Maldague B

    更新日期:2002-05-01 00:00:00

  • Effects of microperfusion in hepatic diffusion weighted imaging.

    abstract:OBJECTIVE:Clinical hepatic diffusion weighted imaging (DWI) generally relies on mono-exponential diffusion. The aim was to demonstrate that mono-exponential diffusion in the liver is contaminated by microperfusion and that the bi-exponential model is required. METHODS:Nineteen fasting healthy volunteers were examined ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-011-2313-1

    authors: Dijkstra H,Baron P,Kappert P,Oudkerk M,Sijens PE

    更新日期:2012-04-01 00:00:00

  • Cardiac CT: coronary arteries and beyond.

    abstract::Multi-detector-row computed tomography (MDCT) has emerged as a rapidly developing method for non-invasive imaging of the heart. An understanding of ECG synchronization, contrast material administration, patient preparation and image post-processing is needed to optimize image quality. The basic technical principles an...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-006-0433-9

    authors: Mahnken AH,Mühlenbruch G,Günther RW,Wildberger JE

    更新日期:2007-04-01 00:00:00

  • High-resolution CT of paediatric lung disease.

    abstract::High-resolution computed tomography (HRCT) has improved our understanding of many lung diseases in adults. The technique is used less often in children due to concerns regarding radiation dose. However, HRCT may provide important diagnostic information in a variety of lung diseases in children including airways diseas...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300100865

    authors: Copley SJ,Padley SP

    更新日期:2001-01-01 00:00:00

  • Pre-treatment amide proton transfer imaging predicts treatment outcome in nasopharyngeal carcinoma.

    abstract:OBJECTIVE:To investigate the value of pre-treatment amide proton transfer-weighted (APTw) imaging for predicting survival of patients with nasopharyngeal carcinoma (NPC). MATERIALS AND METHODS:Pre-treatment APTw imaging was performed in 77 NPC patients and the mean, 90th percentile, skewness, and kurtosis of APT asymm...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-06985-5

    authors: Qamar S,King AD,Ai QH,Mo FKF,Chen W,Poon DMC,Tong M,Ma BB,Yeung DK,Wang YX,Yuan J

    更新日期:2020-11-01 00:00:00

  • Second-Opinion Interpretations of Gynecologic Oncologic MRI Examinations by Sub-Specialized Radiologists Influence Patient Care.

    abstract:PURPOSE:To determine if second-opinion review of gynaecologic oncologic (GynOnc) magnetic resonance imaging (MRI) by sub-specialized radiologists impacts patient care. METHODS:469 second-opinion MRI interpretations rendered by GynOnc radiologists were retrospectively compared to the initial outside reports. Two gynaec...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-4040-5

    authors: Lakhman Y,D'Anastasi M,Miccò M,Scelzo C,Vargas HA,Nougaret S,Sosa RE,Chi DS,Abu-Rustum NR,Hricak H,Sala E

    更新日期:2016-07-01 00:00:00

  • CT perfusion imaging of the liver and the spleen in patients with cirrhosis: Is there a correlation between perfusion and portal venous hypertension?

    abstract:OBJECTIVES:To correlate hepatic and splenic CT perfusion parameters with hepatic venous pressure gradient (HVPG) measurements in patients with cirrhosis. METHODS:Twenty-one patients with cirrhosis (males, 17; females, 4; mean ± SD age, 57 ± 7 years) underwent hepatic and splenic perfusion CT on a 320-detector row volu...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-4788-x

    authors: Talakić E,Schaffellner S,Kniepeiss D,Mueller H,Stauber R,Quehenberger F,Schoellnast H

    更新日期:2017-10-01 00:00:00

  • In vivo dentate nucleus MRI relaxometry correlates with previous administration of Gadolinium-based contrast agents.

    abstract:OBJECTIVES:To evaluate changes in T1 and T2* relaxometry of dentate nuclei (DN) with respect to the number of previous administrations of Gadolinium-based contrast agents (GBCA). METHODS:In 74 relapsing-remitting multiple sclerosis (RR-MS) patients with variable disease duration (9.8±6.8 years) and severity (Expanded ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4245-2

    authors: Tedeschi E,Palma G,Canna A,Cocozza S,Russo C,Borrelli P,Lanzillo R,Angelini V,Postiglione E,Morra VB,Salvatore M,Brunetti A,Quarantelli M

    更新日期:2016-12-01 00:00:00

  • Liver CT perfusion: which is the relevant delay that reduces radiation dose and maintains diagnostic accuracy?

    abstract:OBJECTIVES:High radiation dose during CT perfusion (CTp) studies contributes to prevent CTp application in daily clinical practice. This work evaluates the consequences of scan delay on perfusion parameters and provides guidelines to help reducing the radiation dose by choosing the most appropriate delay. METHODS:Fift...

    journal_title:European radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s00330-019-06259-9

    authors: Bevilacqua A,Malavasi S,Vilgrain V

    更新日期:2019-12-01 00:00:00

  • Topogram-based automated selection of the tube potential and current in thoraco-abdominal trauma CT - a comparison to fixed kV with mAs modulation alone.

    abstract:OBJECTIVE:To investigate the impact of automated attenuation-based tube potential selection on image quality and exposure parameters in polytrauma patients undergoing contrast-enhanced thoraco-abdominal CT. METHODS:One hundred patients were examined on a 16-slice device at 120 kV with 190 ref.mAs and automated mA modu...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-014-3197-7

    authors: Frellesen C,Stock W,Kerl JM,Lehnert T,Wichmann JL,Nau C,Geiger E,Wutzler S,Beeres M,Schulz B,Bodelle B,Ackermann H,Vogl TJ,Bauer RW

    更新日期:2014-07-01 00:00:00

  • Using an electrode as a lever to increase the distance between renal cell carcinoma and bowel during CT-guided radiofrequency ablation.

    abstract::The technique of using an electrode as a lever to increase the distance between renal cell carcinoma (RCC) and bowel during CT-guided radiofrequency ablation (RFA) is described. CT-guided percutaneous RFA was performed in two patients with two RCCs, which were in close proximity to the adjacent bowel. A sterile drape ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-007-0816-6

    authors: Park BK,Kim CK

    更新日期:2008-04-01 00:00:00

  • An aberrant vascular channel in the petrous bone: persistent lateral capital vein?

    abstract::An aberrant channel was identified on CT in the petrous bone in four patients presenting with unrelated otological symptoms. These channels occurred unilaterally in each case. In two patients, the channel was seen to run between the sigmoid sinus sulcus and the superior petrosal sinus sulcus; in one of these patients,...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-009-1492-5

    authors: Hermans R,van Rensburg LJ

    更新日期:2009-12-01 00:00:00

  • Does size reliably predict malignancy in soft tissue tumours?

    abstract:PURPOSE:In this retrospective study we examined whether size is a viable marker of tumour malignancy in soft tissue masses (STM) and if the ratio of width and length (RALD) of an STM reflects tumour biology more accurately. METHODS:Measurements of maximal lesion size and perpendicular diameter were performed in availa...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4300-z

    authors: Gruber L,Loizides A,Ostermann L,Glodny B,Plaikner M,Gruber H

    更新日期:2016-12-01 00:00:00

  • Identifying the most infectious lesions in pulmonary tuberculosis by high-resolution multi-detector computed tomography.

    abstract:OBJECTIVE:This study aimed to determine whether characteristics detected by multi-detector computed tomography (MDCT) were predictive of highly infectious, smear-positive, active pulmonary tuberculosis (PTB). METHODS:Among 124 patients with active PTB, 84 had positive (group 1) and 40 had negative (group 2) smear resu...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-010-1796-5

    authors: Yeh JJ,Chen SC,Teng WB,Chou CH,Hsieh SP,Lee TL,Wu MT

    更新日期:2010-09-01 00:00:00

  • Bilateral tuberculous otomastoiditis in an immmunocompetent 5-year-old child: CT and MRI findings (2009: 3b).

    abstract::Bilateral tuberculous mastoiditis (TOM) in an immunocompetent child is a very uncommon form of tuberculous infection presentation. This report shows the CT and MR imaging of bilateral tuberculous otomastoiditis consisting of aggressive signs of middle ear and mastoid involvement with bony destruction and periauricular...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-008-1130-7

    authors: Munoz A,Ruiz-Contreras J,Jimenez A,Maté I,Calvo M,Villafruela M,del-Pozo G

    更新日期:2009-06-01 00:00:00

  • Development of pumping emulsification device with glass membrane to form ideal lipiodol emulsion in transarterial chemoembolization.

    abstract:PURPOSE:To evaluate a pumping emulsification device that can improve the physiochemical properties and stability of lipiodol emulsion for conventional transarterial chemoembolization. MATERIALS AND METHODS:A pumping emulsification device constructed of a glass membrane with a hydrophobic surface with pore size of 50 μ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-5197-x

    authors: Tanaka T,Masada T,Nishiofuku H,Fukuoka Y,Sato T,Tatsumoto S,Marugami N,Higashi S,Kichikawa K

    更新日期:2018-05-01 00:00:00

  • MRI in guiding and assessing intramyocardial therapy.

    abstract::Cardiovascular intervention, using MRI guidance, is challenging for clinical applications. Real-time imaging sequences with high spatial resolution are needed for monitoring intramyocardial delivery of drug, gene, or stem cell therapies. New generation MR scanners make local intramyocardial and vascular wall therapies...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-004-2622-8

    authors: Saeed M,Saloner D,Weber O,Martin A,Henk C,Higgins C

    更新日期:2005-05-01 00:00:00

  • Large-volume multi-tined expandable RF ablation in pig livers: comparison of 2D and volumetric measurements of the ablation zone.

    abstract:OBJECTIVES:To compare two-dimensional (2D) and three-dimensional (3D) computed tomography (CT) measurements of ablation zones (AZs) related to the shaft of two different large-volume monopolar multi-tined expandable electrodes. METHODS:Percutaneous radiofrequency (RF) ablation was performed in 12 pigs (81.6 +/- 7.8 kg...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-009-1639-4

    authors: Bangard C,Rösgen S,Wahba R,Wiemker R,Hellmich M,Reiter H,Fischer JH,Stippel DL,Lackner KJ

    更新日期:2010-05-01 00:00:00

  • 18F-fluorodeoxyglucose positron emission tomography in patients with recurrent ovarian cancer: in comparison with vascularity, Ki-67, p53, and histologic grade.

    abstract::The aim of this study was to assess the correlation between 18F-fluorodeoxyglucose positron emission tomography (FDG PET) positivity of tumor recurrence and vascularity, Ki-67, p53, and histologic grade in patients with ovarian cancer. Nineteen patients with recurrent ovarian cancer underwent FDG PET before second-loo...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-006-0326-y

    authors: Cho SM,Park YG,Lee JM,Byun JY,Lee JM,Lee KY,Park GS,Kim HS,Lee BY,Lee KH,Song KS

    更新日期:2007-02-01 00:00:00

  • Real-time monitoring of radiofrequency ablation of liver tumors using thermal-dose calculation by MR temperature imaging: initial results in nine patients, including follow-up.

    abstract::To assess the practical feasibility and effectiveness of real-time magnetic resonance (MR) temperature monitoring for the radiofrequency (RF) ablation of liver tumours in a clinical setting, nine patients (aged 49-87 years, five men and four women) with one malignant tumour (14-50 mm, eight hepatocellular carcinomas a...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-009-1532-1

    authors: Lepetit-Coiffé M,Laumonier H,Seror O,Quesson B,Sesay MB,Moonen CT,Grenier N,Trillaud H

    更新日期:2010-01-01 00:00:00

  • Gadoxetic acid disodium-enhanced MR imaging of cholangiolocellular carcinoma of the liver: imaging characteristics and histopathological correlations.

    abstract:OBJECTIVES:To review the gadoxetic acid disodium (EOB)-enhanced magnetic resonance (MR) imaging features of cholangiolocellular carcinoma (CoCC) of the liver and compare them with those of hepatocellular carcinoma (HCC) and intrahepatic cholangiocarcinoma (ICC). METHODS:EOB-enhanced MR images of 19 patients with CoCC,...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-4811-2

    authors: Haradome H,Unno T,Morisaka H,Toda Y,Kwee TC,Kondo H,Sano K,Ichikawa T,Kondo F,Sugitani M,Takayama T

    更新日期:2017-11-01 00:00:00

  • Direct digital mammography image acquisition.

    abstract::Mammography is a branch of radiology which could benefit greatly from the assimilation of digital imaging technologies. Computerized enhancement techniques could be used to ensure optimum presentation of all clinical images. Beyond this it will facilitate powerful new clinical resources such as computer-assisted diagn...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s003300050228

    authors: Cowen AR,Parkin GJ,Hawkridge P

    更新日期:1997-01-01 00:00:00

  • Proper timing for the evaluation of neonatal brain white matter development: a diffusion tensor imaging study.

    abstract:OBJECTIVE:We aimed to determine the timing for assessing birth status of the developing brain (i.e. brain maturity at birth) by exploring the postnatal age-related changes in neonatal brain white matter (WM). METHODS:The institutional review board approved this study and all informed parental consents were obtained. 1...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5665-y

    authors: Jin C,Li Y,Li X,Wang M,Liu C,Gao J,Sun Q,Qiu D,Zeng L,Zhou X,Li G,Zhang J,Zheng J,Yang J

    更新日期:2019-03-01 00:00:00

  • PET/CT in primary musculoskeletal tumours: a step forward.

    abstract::Hybrid imaging with combined positron emission tomography/computed tomography (PET/CT) plays an important role in the staging and management of a wide variety of solid tumours. However, its use in the evaluation of musculoskeletal malignancy has not yet entered routine clinical practice. Cross-sectional imaging with m...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-010-1862-z

    authors: Lakkaraju A,Patel CN,Bradley KM,Scarsbrook AF

    更新日期:2010-12-01 00:00:00