Abstract:
INTRODUCTION:Available literature suggests there is a transient drop in implant stability from approximately week 0 to week 3-4 as a result of peri-implant bone remodeling as it transitions from a primary, mechanical stability to a secondary, biological stability. Research investigating the influence of macro-thread design on this process is scant. AIM:The specific aim of this study was to evaluate the role of macro-thread design on implant stability in the early post-operative healing period using resonance frequency analysis (RFA). MATERIAL AND METHODS:Seven patients, each missing at least two posterior teeth in the same arch, were included in the study. Three patients qualified for four implants resulting in a total of 10 matched pairs. All sites were healed (>6 months), non-grafted sites with sufficient bone to place implants. Each site in a matched pair was randomly assigned to receive either a control (Megagen EZ Plus Internal; EZ) or test (Megagen AnyRidge; AR) implant. The test implant incorporates a novel thread design with a wide thread depth and increased thread pitch. RFA was used to determine implant stability quotient (ISQ) values for each implant at the time of placement and weekly for the first 8 weeks. RESULTS:Implants consistently achieved a relatively high insertion torque (30-45 N/cm) and high initial ISQ value (79.8 ± 1.49). Baseline ISQ values for test (AR; 79.55 ± 1.61) and control (EZ; 80.05 ± 1.37) implants were similar. A general pattern of stability from baseline through all eight follow-up evaluations was observed for the test implants. A pattern of decreasing ISQ values was observed for the control implants across the early follow-up evaluations up to week four, where the value plateaued. There was a statistically significant main effect due to implant type (P < 0.01) and a statistically significant interaction between implant type and time (P < 0.01), indicating that the test and control implants performed differently at certain time points. CONCLUSIONS:Within the limitations of this study, macro-thread design appears to play a role in implant stability in the early post-operative healing period as assessed by RFA. These findings may have important implications related to immediate or early loading protocols.
journal_name
Clin Oral Implants Resjournal_title
Clinical oral implants researchauthors
McCullough JJ,Klokkevold PRdoi
10.1111/clr.12945subject
Has Abstractpub_date
2017-10-01 00:00:00pages
1218-1226issue
10eissn
0905-7161issn
1600-0501journal_volume
28pub_type
杂志文章,随机对照试验abstract:AIM:To test whether an equine bone substitute block used for guided bone regeneration (GBR) of peri-implant defects differs from bovine block or particulate bone substitutes regarding the hard and soft tissue contours of the augmented ridge. MATERIAL & METHODS:Two semi-saddle bone defects were prepared in each side of...
journal_title:Clinical oral implants research
pub_type: 杂志文章
doi:10.1111/clr.13011
更新日期:2017-11-01 00:00:00
abstract:OBJECTIVE:To evaluate the demographic, radiological and therapeutic parameters that influence the overall clinical performance of palatal implants subjected to orthodontic loading. PATIENTS AND METHODS:The data of all patients who had received an orthodontic palatal implant for skeletal anchorage between January 1998 ...
journal_title:Clinical oral implants research
pub_type: 杂志文章,多中心研究
doi:10.1111/j.1600-0501.2011.02197.x
更新日期:2012-06-01 00:00:00
abstract:OBJECTIVES:Maxillary sinus augmentation procedures with bone replacement grafts aimed to increase bone height in the posterior maxilla. During healing, bone particles are partially resorbed and replaced by the patient's own bone. Vitamin D plays an essential role in calcium homeostasis and is critical for bone formatio...
journal_title:Clinical oral implants research
pub_type: 杂志文章,随机对照试验
doi:10.1111/clr.12641
更新日期:2016-06-01 00:00:00
abstract:OBJECTIVE:Short implants are increasingly used, but there is doubt about their performance being similar to that of regular implants. The aim of this study was to compare the mechanical stability of short implants vs. regular implants placed in the edentulous posterior mandible. MATERIAL AND METHODS:Twenty-three patie...
journal_title:Clinical oral implants research
pub_type: 杂志文章
doi:10.1111/clr.12394
更新日期:2015-09-01 00:00:00
abstract:OBJECTIVES:To evaluate the potential influence of different cone-beam computed tomography (CBCT) devices on the transfer accuracy of an open-source system for computer-aided implantology (CAI). MATERIAL AND METHODS:A total of 108 implants in 18 partially edentulous patient-equivalent models were planned and fully guid...
journal_title:Clinical oral implants research
pub_type: 杂志文章
doi:10.1111/j.1600-0501.2011.02272.x
更新日期:2012-09-01 00:00:00
abstract:OBJECTIVES:To evaluate the implant failure, marginal bone loss (MBL), and other biological or technical complications of restorations supported by tilted and straight implants after at least 3 years in function. METHODS:Electronic and manual searches were performed in MEDLINE, Embase, Web of Science, and OpenGrey to i...
journal_title:Clinical oral implants research
pub_type: 杂志文章,meta分析
doi:10.1111/clr.13279
更新日期:2018-10-01 00:00:00
abstract:AIM:To evaluate the soft tissue and the dimensional changes of the alveolar bony crest at sites where deproteinized bovine bone mineral (DBBM) particles, concomitantly with the placement of a collagen membrane, were used at implants installed into sockets immediately after tooth extraction. MATERIAL AND METHODS:The pu...
journal_title:Clinical oral implants research
pub_type: 杂志文章
doi:10.1111/j.1600-0501.2011.02332.x
更新日期:2012-07-01 00:00:00
abstract:OBJECTIVES:The objectives of this systematic review were to assess the 5-year survival of resin-bonded bridges (RBBs) and to describe the incidence of technical and biological complications. METHODS:An electronic Medline search complemented by manual searching was conducted to identify prospective and retrospective co...
journal_title:Clinical oral implants research
pub_type: 杂志文章,评审
doi:10.1111/j.1600-0501.2007.01527.x
更新日期:2008-02-01 00:00:00
abstract:AIM:This study compared the effects of Escherichia-coli-produced recombinant human bone morphogenetic protein 2 (ErhBMP-2) with a biphasic calcium phosphate (BCP) carrier to those of deproteinized bovine bone in human maxillary sinus floor augmentation. MATERIAL AND METHODS:Screening for this clinical trial selected 5...
journal_title:Clinical oral implants research
pub_type: 杂志文章,多中心研究,随机对照试验
doi:10.1111/clr.12471
更新日期:2015-12-01 00:00:00
abstract::In a prospective study, 20 patients who underwent harvesting of chin grafts as outpatients, were followed up for 12 months (3 further patients with incomplete follow-up data were excluded from the study). Preoperatively and 7 days, 1, 3, 6 and 12 months postoperatively, follow-up data were assessed. Evaluation of the ...
journal_title:Clinical oral implants research
pub_type: 杂志文章
doi:10.1034/j.1600-0501.2001.120510.x
更新日期:2001-10-01 00:00:00
abstract:OBJECTIVE:To identify clinical studies evaluating efficiency and/or effectiveness of digital technologies as compared to conventional manufacturing procedures for the fabrication of implant-supported reconstructions. MATERIALS AND METHODS:A systematic search from 1990 through July 2017 was performed using the online d...
journal_title:Clinical oral implants research
pub_type: 杂志文章
doi:10.1111/clr.13300
更新日期:2018-10-01 00:00:00
abstract::This study details the structural and ultrastructural features of the interfaces between titanium implants and their surrounding tissues. The material stemmed from an experiment in dogs in which guided tissue regeneration with Gore-Tex membranes was used to treat peri-implant, ligature-induced tissue breakdown around ...
journal_title:Clinical oral implants research
pub_type: 杂志文章
doi:10.1034/j.1600-0501.1994.050201.x
更新日期:1994-06-01 00:00:00
abstract::It was hypothesized that the bending stiffness of the mandible is an important biomechanical parameter in implant dentistry. It was shown how this bending stiffness can be estimated by means of the principal area moments of inertia of the cortical and cancellous cross-sections as obtained by computed tomography, some ...
journal_title:Clinical oral implants research
pub_type: 杂志文章
doi:10.1111/j.1600-0501.2004.01021.x
更新日期:2004-08-01 00:00:00
abstract::The objective of the present investigation was to characterize the cellular composition of the soft tissues surrounding consecutively retrieved late failures of Brånemark implants. Criteria for implant failure were signs of loss of osseointegration (radiographic peri-fixtural radiolucency and mobility). The clinical h...
journal_title:Clinical oral implants research
pub_type: 杂志文章
doi:10.1034/j.1600-0501.1997.080502.x
更新日期:1997-10-01 00:00:00
abstract::This review article provides an overview of cone beam (CB) imaging technology and its role in orofacial imaging, including comparison with two-dimensional (2D) radiography and multislice computed tomography (MCT). The radiation dose levels of CB systems are discussed, with reference to those delivered by MCT and commo...
journal_title:Clinical oral implants research
pub_type: 杂志文章,评审
doi:10.1111/j.1600-0501.2010.01996.x
更新日期:2010-11-01 00:00:00
abstract:OBJECTIVES:The purpose of the present study was to evaluate the survival rate of dental implants in previously failed implant sites. In addition, factors that might affect the outcome of these redo procedures were also explored. MATERIAL AND METHODS:Patients that had failed dental implants, which were replaced with th...
journal_title:Clinical oral implants research
pub_type: 杂志文章
doi:10.1111/j.1600-0501.2007.01466.x
更新日期:2008-03-01 00:00:00
abstract::This study aimed to investigate the effect of hyperbaric oxygen (HBO) therapy on the tissue reactions to commercially pure (c.p.) titanium implants placed in free autogenous bone graft by a 1-stage procedure. Eighty c.p. titanium implants were placed in the bone grafted from iliac crest to bilateral mandible of 40 Jap...
journal_title:Clinical oral implants research
pub_type: 杂志文章
doi:10.1034/j.1600-0501.1996.090604.x
更新日期:1998-12-01 00:00:00
abstract:OBJECTIVES:To prospectively evaluate, as part of an ongoing randomized pilot trial, the clinical outcomes of two-piece zirconia implants in comparison with titanium implants 80 months after delivery of all-ceramic (lithium disilicate) single-tooth restorations. MATERIAL AND METHODS:The original sample included 31 (16 ...
journal_title:Clinical oral implants research
pub_type: 杂志文章,随机对照试验
doi:10.1111/clr.13576
更新日期:2020-04-01 00:00:00
abstract:BACKGROUND:Alumina-toughened zirconia (ATZ) is a possible alternative material to titanium for oral implants. No data are available on the fracture strength of ATZ oral implants. PURPOSE:The purpose of this study was to examine one-piece implants made of ATZ ceramic under artificial loading conditions and to compare t...
journal_title:Clinical oral implants research
pub_type: 杂志文章
doi:10.1111/j.1600-0501.2010.01954.x
更新日期:2010-12-01 00:00:00
abstract:OBJECTIVE:The purpose of this study was to investigate the effects of a nanostructured calcium coating on the surfaces of blasted Ti implants on peri-implant bone formation in the rabbit tibiae. MATERIAL AND METHODS:Threaded implants (3.75 mm in diameter, 6 mm in length) were roughened by hydroxyapatite (HA) blasting ...
journal_title:Clinical oral implants research
pub_type: 杂志文章
doi:10.1111/j.1600-0501.2006.01323.x
更新日期:2007-06-01 00:00:00
abstract:BACKGROUND:The transcrestal approach with osteotomes is a commonly applied and predictable technique for maxillary sinus floor elevation. However, Schneiderian membrane perforation is a common and often inevitable intraoperative complication. Recently, the use of balloons has been proposed to reduce the risk of sinus m...
journal_title:Clinical oral implants research
pub_type: 杂志文章,随机对照试验
doi:10.1111/j.1600-0501.2012.02506.x
更新日期:2013-09-01 00:00:00
abstract:OBJECTIVES:To evaluate the effect of immortalized hypertrophic chondrocytes extracellular matrix (HCM) with or without the use of guided bone regeneration (GBR) on the healing of critical-size calvarial defects. MATERIAL AND METHODS:In 42 rats, 5 mm critical-size calvarial defects were surgically created. The animals ...
journal_title:Clinical oral implants research
pub_type: 杂志文章
doi:10.1111/j.1600-0501.2010.02120.x
更新日期:2011-12-01 00:00:00
abstract:OBJECTIVES:This study aimed to evaluate histologic and histomorphometric bone characteristics with a focus on vitality after lateral alveolar ridge augmentation using an autogenous bone graft as a block covered by either a platelet-rich fibrin (PRF) membrane (test group) or a standard procedure involving coverage of th...
journal_title:Clinical oral implants research
pub_type: 杂志文章,随机对照试验
doi:10.1111/clr.13605
更新日期:2020-08-01 00:00:00
abstract:OBJECTIVES:A removable implant-retained dental prosthesis in an edentulous mandible can use telescopic crowns or a bar superstructure as anchorage elements for an overdenture. The aim of this study was to compare the clinical results for bar-anchored and telescopic crown-retained overdentures in implant prosthetic trea...
journal_title:Clinical oral implants research
pub_type: 杂志文章,随机对照试验
doi:10.1111/j.1600-0501.2007.01500.x
更新日期:2008-05-01 00:00:00
abstract:OBJECTIVE:Bacterial species have been found harboring the internal surface of dental implants as consequence of their failed connections. The aim of the present study was to compare the detection frequency of bacterial leakage from human saliva through the implant-abutment interface, under non-loading conditions, using...
journal_title:Clinical oral implants research
pub_type: 杂志文章
doi:10.1111/j.1600-0501.2011.02280.x
更新日期:2012-10-01 00:00:00
abstract:OBJECTIVE:The aim of this study is to analyze the morphology and proliferation of human osteoblastic cells in vitro on five commercially available titanium surfaces. MATERIALS AND METHODS:Human primary cells of the osteoblastic lineage were obtained from bone explants. The cells were plated on polished (T1), machined ...
journal_title:Clinical oral implants research
pub_type: 杂志文章
doi:10.1111/j.1600-0501.2009.01906.x
更新日期:2010-07-01 00:00:00
abstract::Breakdown of bone around oral implants following occlusal overload or plaque accumulation was evaluated in monkeys. 5 screw-type implants of pure titanium (Astra Tech) were inserted in the mandible of 4 monkeys (Macaca Fascicularis). 6 months after insertion of the implants a fixed partial prosthesis was mounted on th...
journal_title:Clinical oral implants research
pub_type: 杂志文章
doi:10.1111/j.1600-0501.1997.tb00001.x
更新日期:1997-02-01 00:00:00
abstract::The installation of implants directly into extraction sockets offers considerable advantages over other treatment modalities for both practitioners and patients. Usually, immediate implants are placed and subsequently covered by mucosa allowing a submerged healing mode. This report presents the rationale, clinical pro...
journal_title:Clinical oral implants research
pub_type: 杂志文章
doi:10.1034/j.1600-0501.1994.050306.x
更新日期:1994-09-01 00:00:00
abstract:BACKGROUND:In the replacement of missing teeth, a paradigm shift is currently observed with immediate implant placement and/or restoration, particularly in the aesthetic zone. In molar sites, however, anatomical, occlusal and biomechanical considerations remain deterrent factors influencing the outcome of this treatmen...
journal_title:Clinical oral implants research
pub_type: 杂志文章
doi:10.1111/j.1600-0501.2011.02415.x
更新日期:2013-05-01 00:00:00
abstract:OBJECTIVES:To investigate the role of different levels of pH of artificial saliva under simulated oral environment on the corrosion behavior of commercially pure titanium (cp-Ti) and Ti-6Al-4V alloy. Special attention is given to understand the changes in corrosion kinetics and surface characterization of Ti by using e...
journal_title:Clinical oral implants research
pub_type: 杂志文章
doi:10.1111/j.1600-0501.2011.02265.x
更新日期:2012-09-01 00:00:00