Abstract:
:Purpose To compare the prognostic performances of clinical T categorization between the longest diameter and average diameter at CT in patients who underwent surgical resection of non-small cell lung cancers (NSCLCs). Materials and Methods This study retrospectively determined clinical T categories based on the longest diameter (clinical Tlongest) and average diameter (clinical Taverage) in 1153 patients, including 651 men (median age, 67 years; interquartile range [IQR], 60-72 years) and 502 women (median age, 63 years; IQR, 55-70 years) who underwent preoperative chest CT and subsequent resection of NSCLCs (clinical T1 to clinical T4; N0M0) between 2009 and 2015. Prognostic performances for disease-free survival (DFS) were compared between clinical Tlongest and clinical Taverage by using the Harrell concordance indexes and Student t test. The effect of the average diameter on clinical T category shifts (downstaging) was also investigated by using the McNemar-Bowker test. Results Concordance indexes did not significantly differ between clinical Tlongest (0.72; 95% confidence interval [CI]: 0.67, 0.76) and clinical Taverage (0.70; 95% CI: 0.64, 0.75) (P = .12 for the comparison). In the clinical T1 subgroup analysis, concordance indexes were 0.77 (95% CI: 0.71, 0.83) for clinical Tlongest and 0.75 (95% CI: 0.69, 0.81) for clinical Taverage (P = .17 for the comparison). Use of the clinical Taverage resulted in significant downstaging in all clinical T categories (P < .001). Conclusion The prognostic performance of clinical T categorization was not significantly different between the longest and average diameter measurements. Clinical T categorization based on the longest tumor diameter at CT was demonstrated to be sufficient for risk stratification of surgically treated non-small cell lung cancers. © RSNA, 2019 Online supplemental material is available for this article.
journal_name
Radiologyjournal_title
Radiologyauthors
Kim H,Goo JM,Kim YT,Park CMdoi
10.1148/radiol.2019182068subject
Has Abstractpub_date
2019-03-01 00:00:00pages
807-813issue
3eissn
0033-8419issn
1527-1315journal_volume
290pub_type
杂志文章相关文献
RADIOLOGY文献大全abstract::Radiology chiefs at hospitals with open heart surgery programs were queried to ascertain both current and desired degrees of participation by radiologists in coronary angiography. While current participation is limited, respondents indicated a desire to achieve increased active participation. Opposition of cardiologis...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/125.2.313
更新日期:1977-11-01 00:00:00
abstract::Real-time ultrasonography was useful in differentiating tumor from syringohydromyelia as the cause of cervical cord widening in four patients. Those with syringohydromyelia had a smooth, regular, cystic space located symmetrically in the spinal cord. Tumor appeared as an echogenic, hypoechoic, or cystic expansile lesi...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.151.1.6701310
更新日期:1984-04-01 00:00:00
abstract::The purpose of the study was to implement a three-dimensional (3D) magnetic resonance (MR) angiographic technique with acquisition times on the order of 800 msec with use of a spoiled gradient-echo pulse sequence (repetition time, 1.60 msec; echo time, 0.65 msec) and bolus intravenous injection of contrast material do...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2243010984
更新日期:2002-09-01 00:00:00
abstract:PURPOSE:To investigate the effect of variations in anatomic features of the circle of Willis on the perfusion territory to deep structures, including the nucleus caudatus, the nucleus lentiformis, and the thalamus. MATERIALS AND METHODS:The ethics committee of the study institution approved the study protocol. A total...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.09090284
更新日期:2010-03-01 00:00:00
abstract::Pulmonary angiography is sensitive and specific in the diagnosis of pulmonary thromboembolism, but it remains an invasive procedure. Experience with 1,350 pulmonary angiograms was reviewed to ascertain the incidence, etiologies, and avoidance of complications. There were three deaths, all of which were secondary to co...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.136.2.7403500
更新日期:1980-08-01 00:00:00
abstract:PURPOSE:To prospectively determine the accuracy of combination positron emission tomography-computed tomography (PET/CT) in lymph node staging in patients with early-stage cervical cancer, with histopathologic results as the reference standard. MATERIALS AND METHODS:The study was institutional review board approved, a...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2381041799
更新日期:2006-01-01 00:00:00
abstract::Twenty pigs underwent (a) cystic duct occlusion by means of fluoroscopically guided transcatheter endoluminal bipolar radio-frequency (RF) electrocoagulation and (b) gallbladder sclerotherapy with one of two different regimens of ethanol and sodium tetradecyl-sulfate (STS). Serum ethanol levels and hepatic enzyme test...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.171.1.2928530
更新日期:1989-04-01 00:00:00
abstract:PURPOSE:To assess the value of resistive index (RI) and systolic acceleration time (SAT) for diagnosis of stenoses and thromboses of the hepatic artery in liver transplant recipients. MATERIALS AND METHODS:Doppler sonograms and angiograms in 125 liver transplant recipients were correlated and analyzed for any statisti...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.192.3.8058930
更新日期:1994-09-01 00:00:00
abstract::Computed tomography (CT) scans of 9 surgically proved cases of cerebral abscess were reviewed. The CT characteristics were studied, as were the postoperative scans. Also assessed were the contributions to the diagnosis of the clinical features, plain radiographic examinations, radionuclide imaging, and angiography. Th...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/121.3.641
更新日期:1976-12-01 00:00:00
abstract::Lung abscesses were drained by means of catheters guided by computed tomography (CT) in 19 patients who still had sepsis despite standard medical therapy; all patients had received antibiotics for at least 5 days, and 11 of the 19 patients had undergone bronchoscopy. The abscess was cured (by clinical and radiographic...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.178.2.1987590
更新日期:1991-02-01 00:00:00
abstract::The sonograms of 40 patients with second-trimester polyhydramnios were reviewed to determine (a) whether fetal and maternal conditions occur as often during second-trimester polyhydramnios as during third-trimester polyhydramnios, (b) the frequency of persistence of polyhydramnios into the third trimester, and (c) how...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.165.2.3310100
更新日期:1987-11-01 00:00:00
abstract::Pseudostenosis of the rectosigmoid colon due to compression by a dilated urinary bladder may pose a diagnostic problem. Although probably quite common, it has not received much attention in the radiological literature. Four cases are presented and the radiological features on barium enema are described. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/127.3.645
更新日期:1978-06-01 00:00:00
abstract:PURPOSE:To prospectively determine sensitivity and specificity of breast magnetic resonance (MR) imaging in a screening and symptomatic population by using independent double reading, with histologic or cytologic results or a minimum 18-month follow-up as the standard. MATERIALS AND METHODS:Informed consent and ethica...
journal_title:Radiology
pub_type: 杂志文章,多中心研究
doi:10.1148/radiol.2363040735
更新日期:2005-09-01 00:00:00
abstract:PURPOSE:To evaluate fluid-attenuated inversion-recovery (FLAIR) magnetic resonance (MR) imaging in a blinded reader study for the detection of proved subarachnoid space (SAS) disease. MATERIALS AND METHODS:FLAIR MR imaging was performed in 62 patients (21 with proved SAS or meningeal disease) and 41 control patients. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.208.2.9680570
更新日期:1998-08-01 00:00:00
abstract::Pelvic sonograms from 61 consecutive patients with suspected ectopic pregnancy and an additional 17 proved ectopic pregnancy cases were reviewed retrospectively. Special attention was given to the appearance of the uterus and intrauterine fluid collections in the absence of a fetal pole. Criteria for the exclusion of ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.143.1.7063730
更新日期:1982-04-01 00:00:00
abstract::Liposomal gadolinium diethylenetriaminepentaacetic acid (DTPA) encapsulated within 70- and 400-nm vesicles was tested as a contrast agent for magnetic resonance (MR) imaging of the liver in rats with hepatic metastases. Liposomal Gd-DTPA caused significant improvement in contrast between liver and tumor (P less than ....
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.171.1.2928550
更新日期:1989-04-01 00:00:00
abstract::Images from endoscopic retrograde pancreatography performed in 38 patients with cystic pancreatic neoplasms were reviewed to determine whether they might allow differentiation of malignant from benign lesions. Twenty-three patients had histologically proved benign lesions; 15 had frankly malignant lesions. Images were...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.188.3.8394590
更新日期:1993-09-01 00:00:00
abstract:PURPOSE:To evaluate magnetic resonance (MR) hydrometry, a method of quantifying fluid amounts by using MR imaging, for assessing the exocrine function of the pancreas after stimulation with secretin. MATERIALS AND METHODS:Images were obtained with a single-shot turbo spin-echo sequence by using a 1.0-T magnet with a q...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.218.1.r01ja2061
更新日期:2001-01-01 00:00:00
abstract::Background Early stage hepatocellular carcinoma (HCC) is the ideal candidate for resection in patients with preserved liver function; however, cancer will recur in half of these patients and no reliable prognostic tool has been established. Purpose To investigate the effectiveness of radiomic features in predicting tu...
journal_title:Radiology
pub_type: 杂志文章,多中心研究
doi:10.1148/radiol.2020191470
更新日期:2020-03-01 00:00:00
abstract:PURPOSE:To evaluate prospectively bolus tracking to time hepatic arterial phase (HAP) imaging of hypervascular hepatocellular carcinomas (HCCs) with a 40-detector computed tomographic (CT) scanner. MATERIALS AND METHODS:This study received institutional review board approval; informed consent was obtained. The study i...
journal_title:Radiology
pub_type: 杂志文章,随机对照试验
doi:10.1148/radiol.2431060069
更新日期:2007-04-01 00:00:00
abstract::A phase I/II clinical trial with indium-111-labeled antimucin murine monoclonal antibody (MoAb) CCR 086 was conducted. Seventeen patients with histologically proved colorectal carcinoma and known metastatic disease underwent external scintigraphy after administration of 5.5 mCi (203.5 MBq) of In-111 CCR 086 at doses o...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.176.1.2353080
更新日期:1990-07-01 00:00:00
abstract::An ex vivo magnetic resonance (MR) colonographic system with a bovine colon with polyps of predetermined dimensions was developed for evaluation and optimization of different combinations of imaging sequences and intraluminal contrast agents. Findings were then applied during in vivo testing in human subjects. The res...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2251011664
更新日期:2002-11-01 00:00:00
abstract:PURPOSE:To determine the reliability and accuracy of magnetic resonance (MR) arthrography for the diagnosis of superior labral anterior posterior (SLAP) tears. MATERIALS AND METHODS:The MR arthrograms in 80 patients who underwent arthroscopy and MR arthrography during a 54-month period were retrospectively reviewed. M...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.218.1.r01ja44127
更新日期:2001-01-01 00:00:00
abstract::Measurements of the intensity distribution of a 60-Co beam revealed a significant field distortion caused by minor misalignment of the collimator assembly which was not detected by routine methods. Accurate monitoring of radiation intensity distribution and periodic visual inspection of collimators are suggested for ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/116.1.226
更新日期:1975-07-01 00:00:00
abstract::The line spread function (LSF) and modulation transfer function (MTF) of 9 rare-earth screen/film systems were measured and compared with those of two fast calcium tungstate systems, using double-emulsion films sandwiched between two screens and mounted in regular cassettes. The LSFs were found to fit exponential func...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/121.2.473
更新日期:1976-11-01 00:00:00
abstract:PURPOSE:To summarize the overall diagnostic performance of magnetic resonance (MR) angiography in the evaluation of peripheral arteriosclerotic occlusive disease and to identify the most important sources of variation in diagnostic accuracy between studies. MATERIALS AND METHODS:A search strategy in MEDLINE and citati...
journal_title:Radiology
pub_type: 杂志文章,meta分析
doi:10.1148/radiology.217.1.r00oc11105
更新日期:2000-10-01 00:00:00
abstract::The diagnostic quality and side effects of Amipaque and Pantopaque as myelographic contrast agents were compared prospectively using the identical protocol in 167 cases (117 Amipaque, 50 Pantopaque). Good ratings were attained in 74% of Amipaque and 76% of Pantopaque examinations. Demonstration of nerve rootlets in th...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/129.3.695
更新日期:1978-12-01 00:00:00
abstract::The CT scanner makes three-dimensional anatomical information available for treatment planning, the calculational algorithm being the limiting factor in dose calculations. A method has been developed, called the "effective tissue-air ratio method," that uses all the information but reduces it to manageable proportions...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/129.3.787
更新日期:1978-12-01 00:00:00
abstract:PURPOSE:To assess the effect of using a lossy Joint Photographic Experts Group standard for wavelet image compression, JPEG2000, on pulmonary nodule detection at low-dose computed tomography (CT). MATERIALS AND METHODS:One hundred sets of lung CT data ("cases") were compressed to 30:1, 20:1, and 10:1 levels by using a...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2281020254
更新日期:2003-07-01 00:00:00
abstract:PURPOSE:To evaluate a technique to perform fluoroscopically directed thoracic transforaminal epidural injections. MATERIALS AND METHODS:Institutional review board approval and a waiver of consent were obtained for this retrospective HIPAA-compliant study. Findings from 198 consecutively performed foraminal nerve block...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.09082085
更新日期:2010-02-01 00:00:00