Abstract:
:Over 100 cases of standard extracapsular cataract extraction with intraocular lens implantation were reviewed and the effects of two commercially available pharmacological agents were compared. The treatment groups received either acetylcholine chloride (Miochol) or carbachol (Miostat). Intraocular pressures were measured preoperatively and 20 to 24 hours postoperatively. The difference in mean pressures between the treatment groups was statistically significant. The results of the study showed Miostat to be the better pharmacological agent for controlling intraocular pressure 20 to 24 hours later. Since the majority of surgeons use Miochol rather than Miostat, the conclusions of this study appear to be significant.
journal_name
J Cataract Refract Surgjournal_title
Journal of cataract and refractive surgeryauthors
McKinzie JW,Boggs MB Jrdoi
10.1016/s0886-3350(89)80008-2subject
Has Abstractpub_date
1989-03-01 00:00:00pages
185-90issue
2eissn
0886-3350issn
1873-4502pii
S0886-3350(89)80008-2journal_volume
15pub_type
杂志文章abstract:UNLABELLED:An 83-year-old man presented with a 1-year history of blurry vision in his left eye. Bilateral cataract surgery and ciliary sulcus posterior chamber intraocular lens (IOL) implantation had been performed 11 years earlier. The corrected distance visual acuity (CDVA) was 20/60 in the left eye. Slitlamp examina...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章,评审
doi:10.1016/j.jcrs.2015.09.013
更新日期:2015-10-01 00:00:00
abstract:PURPOSE:To determine the sex hormone levels in the serum and aqueous humor in patients with age-related cataract and the corresponding hormone receptors in cataract lens epithelial cells (LECs). SETTING:Research Laboratory, International Intraocular Implant Training Center, Tianjin Medical University, Tianjin, China. ...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(02)01436-0
更新日期:2003-01-01 00:00:00
abstract:PURPOSE:To examine the psychometric properties of the Visual Activities Questionnaire (VAQ) and each of its subscales in a modern cataract population using Rasch analysis and if flawed, to revise the VAQ and create a valid measure that maximizes its measurement properties. SETTING:Flinders Eye Centre, Flinders Medical...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2009.05.058
更新日期:2009-11-01 00:00:00
abstract:PURPOSE:To compare the values for corneal power determined by the axial, instantaneous and refractive formulas when imaging normal human corneas using computerized videokeratography. SETTING:Cullen Eye Institute, Baylor College of Medicine, Houston, Texas, USA. METHODS:This prospective clinical trial involved 60 corn...
journal_title:Journal of cataract and refractive surgery
pub_type: 临床试验,杂志文章
doi:10.1016/s0886-3350(98)80009-6
更新日期:1998-09-01 00:00:00
abstract::We present the case of a 56-year-old woman with moderate myopia and bilateral cataract who had cataract extraction and intraocular lens (IOL) implantation. Due to the patient's desire for spectacle independence, a trifocal IOL with toric correction for astigmatism was implanted. During the follow-up, it became obvious...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2016.02.001
更新日期:2016-03-01 00:00:00
abstract:PURPOSE:To evaluate the long-term outcomes of laser in situ keratomileusis (LASIK) for high myopia with or without astigmatism. SETTING:Vissum Instituto Oftalmologico de Alicante and Miguel Hernandez University, Alicante, Spain. DESIGN:Retrospective-prospective case series. METHODS:Laser in situ keratomileusis was p...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2014.08.029
更新日期:2015-01-01 00:00:00
abstract::Two cases of intrastromal corneal ring (Intacs, Addition Technology) implantation to treat post-laser in situ keratomileusis (LASIK) ectasia developed progressive slippage of the flap over the stromal bed, resulting in progressive flattening of the affected meridian. The flattening was thought to have occurred because...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2008.06.049
更新日期:2008-12-01 00:00:00
abstract:PURPOSE:To describe the indications, motivations, and outcomes of artificial iris exchange. SETTING:Stein Eye Institute. DESIGN:Consecutive case series. METHODS:Review of medical records of patients implanted with an artificial iris device who underwent a subsequent artificial iris exchange. RESULTS:Five patients w...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1097/j.jcrs.0000000000000321
更新日期:2020-12-01 00:00:00
abstract::Twenty-three eyes of 20 patients who had had myopic epikeratoplasty were evaluated and the mean 21-month postoperative results (range: 12 to 47 months) tabulated. Average preoperative myopia was -16.7 diopters (D) spherical equivalent (range: -10 to -33 D), and average postoperative refractive correction was 13 D. Of ...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(13)80305-7
更新日期:1993-05-01 00:00:00
abstract:PURPOSE:To study the architecture of clear corneal incisions for phacoemulsification cataract surgery using optical coherence tomography (OCT). SETTING:Doheny Eye Institute and Department of Ophthalmology, Keck School of Medicine of the University of Southern California, Los Angeles, California, USA. METHODS:This pro...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章,多中心研究
doi:10.1016/j.jcrs.2008.05.026
更新日期:2008-09-01 00:00:00
abstract:PURPOSE:To evaluate the visual results and complications of angle-supported phakic intraocular lenses (IOLs) to correct myopia associated with early-stage keratoconus. SETTING:Private practice, Siena, Italy. METHODS:In a prospective noncomparative single-surgeon interventional case series, outcomes in 12 consecutive ...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(03)00346-8
更新日期:2003-08-01 00:00:00
abstract:PURPOSE:To prospectively investigate the incidence, associated factors, and prognostic significance of relative afferent pupillary defects (RAPDs) in eyes with less severe cataract than in contralateral eyes. SETTING:Department of Ophthalmology, Seoul Municipal Boramae Hospital, College of Medicine, Seoul National Uni...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2003.11.022
更新日期:2004-01-01 00:00:00
abstract::A 38-year-old woman had posterior chamber phakic intraocular lens (IOL) implantation as a secondary refractive procedure to correct residual refraction (20/50 with -16.50 -1.50 x 80) in May 1998, 3 years after intrastromal corneal ring segment surgery for high myopia (-30.00 diopters). Ultrasound biomicroscopy reveale...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(00)00410-7
更新日期:2000-05-01 00:00:00
abstract:PURPOSE:To evaluate meridional differences in angle-to-angle (A-A) and sulcus-to-sulcus (S-S) dimensions in human eyes using very high frequency ultrasound (VHF US) and anterior segment optical coherence tomography (AS-OCT). SETTING:John A. Moran Eye Center, University of Utah, USA; Berlin Eye Research Institute, Germ...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2008.03.033
更新日期:2008-07-01 00:00:00
abstract:PURPOSE:To assess the efficacy of sublingual lorazepam in inducing amnesia when used as a premedication for peribulbar anesthesia. SETTING:Department of Ophthalmology in a large district general hospital. METHODS:Following local ethical committee approval, a prospective, randomized, placebo-controlled, double-blind s...
journal_title:Journal of cataract and refractive surgery
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1016/s0886-3350(97)80033-8
更新日期:1997-12-01 00:00:00
abstract:UNLABELLED:We report a case in which toric intraocular Collamer lenses (ICLs) effectively corrected the refractive errors of pellucid marginal degeneration (PMD). Preoperatively, in the patient's right eye, the manifest refraction was -10.5 -3.5 x 55, the uncorrected distance visual acuity (UDVA) was 20/1000, and the c...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2009.08.021
更新日期:2010-01-01 00:00:00
abstract::Unwanted optical images are noticed by a surprisingly large number of patients following cataract extraction with implantation of posterior chamber intraocular lenses (IOLs). These images are caused by the positioning holes, lens edge, or laser ridge. We studied 550 eyes in which one of seven different IOLs was insert...
journal_title:Journal of cataract and refractive surgery
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1016/s0886-3350(89)80113-0
更新日期:1989-09-01 00:00:00
abstract:PURPOSE:To determine whether vault measurements after placement of a hole implantable collamer lens (hole ICL) (KS-AquaPORT) can be predicted by angle-to-angle (ATA) and white-to-white (WTW) measurements obtained with anterior segment optical coherence tomography (AS-OCT). SETTING:Sanno Hospital, Tokyo, Japan. DESIGN...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2019.02.020
更新日期:2019-08-01 00:00:00
abstract::The current trend toward implantation of posterior chamber lenses within the capsular bag rather than the ciliary sulcus seems logical in light of the increasing evidence of uveal damage from sulcus fixated posterior chamber lenses. However, long-term, successful capsular bag fixation has not been demonstrated with cu...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(87)80040-8
更新日期:1987-07-01 00:00:00
abstract:PURPOSE:To compare the incidence of diffuse lamellar keratitis (DLK) after laser in situ keratomileusis (LASIK) with flap creation using the 15 kHz (FS15), 30 kHz (FS30), or 60 kHz (FS60) femtosecond laser. SETTING:University-based academic practice, Ann Arbor, Michigan, USA. DESIGN:Retrospective comparative case ser...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2010.09.003
更新日期:2010-11-01 00:00:00
abstract:PURPOSE:To evaluate the refractive accuracy of intraocular lens (IOL) power calculation after phacovitrectomy. SETTING:Eye Hospital Zonnestraal and Department of Ophthalmology Academic Medical Center, Amsterdam, the Netherlands. DESIGN:Retrospective comparative case series. METHODS:Refraction results 1 month after p...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2016.03.034
更新日期:2016-06-01 00:00:00
abstract:PURPOSE:To validate clinically in a normal healthy population an algorithm to correct the error in the keratometric estimation of corneal power based on the use of a variable keratometric index of refraction (n(k)). SETTING:Medimar International Hospital (Oftalmar) and University of Alicante, Alicante, Spain. DESIGN:...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2012.03.026
更新日期:2012-08-01 00:00:00
abstract::A retrospective analysis of 40 cases of sulcus-fixated one-piece poly(methyl methacrylate) posterior chamber lenses revealed ten cases (25%) that demonstrated oval deformation of the pupil, similar to the condition associated with anterior chamber lenses. This complication was not noted until several weeks after surge...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(13)80803-6
更新日期:1990-07-01 00:00:00
abstract:PURPOSE:To measure the relative difficulty of each stage of phacoemulsification surgery performed by basic surgical trainees. SETTING:Mater Misericordiae University Hospital, Dublin, Ireland. METHODS:This prospective study comprised 100 consecutive cases of phacoemulsification performed by 8 trainee surgeons over an ...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2006.01.045
更新日期:2006-04-01 00:00:00
abstract:PURPOSE:To determine the predictability and consistency of corneal flap thickness, flap diameter, and hinge length with the modern 100 microm head of the Moria LSK-One manual microkeratome. SETTING:Private clinic, office-based practice. METHODS:Forty-two consecutive eyes with no previous surgery having thin flap lase...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2004.10.056
更新日期:2005-06-01 00:00:00
abstract:PURPOSE:To evaluate irregularity of the anterior and posterior cornea before and after Descemet-stripping endothelial keratoplasty (DSEK) and its effect on visual acuity. SETTING:Department of Ophthalmology, Keio University School of Medicine, Tokyo, Japan. METHODS:Corneal data were acquired using a rotating Scheimpf...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2008.11.062
更新日期:2009-04-01 00:00:00
abstract:PURPOSE:To evaluate surgically induced corneal astigmatism after small superotemporal and superonasal clear corneal incision cataract surgery. SETTING:Department of Ophthalmology, School of Medicine, University of Afyon Kocatepe, Afyon, Turkey. METHODS:This prospective study comprised 56 eyes of 28 patients who had b...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2003.11.034
更新日期:2004-06-01 00:00:00
abstract:PURPOSE:To evaluate alterations in corneal power parameters after Descemet-stripping automated endothelial keratoplasty (DSAEK) using rotating Scheimpflug imaging. SETTING:University of Texas, Southwestern Medical Center, Dallas, Texas, USA. METHODS:Eyes that had DSAEK were evaluated with a rotating Scheimpflug imagi...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2010.01.032
更新日期:2010-08-01 00:00:00
abstract::A 40-year old man, highly myopic in both eyes, had laser in situ keratomileusis (LASIK) in the left eye in November 1996. Corneal melting and ulceration and fine striae-like interface infiltrates were noticed 1 day postoperatively. There was no response to intensive topical antibiotics in the form of hourly ofloxacin ...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(99)00080-2
更新日期:1999-07-01 00:00:00
abstract::The ergonomics of ocular surgery has received little attention even though the usual positioning of the patient and surgeon during traditional cataract surgery places the surgeon at risk for back, neck, and arm strain. The recent development of the temporal cataract incision allows the operating microscope to be tilte...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(99)80122-9
更新日期:1999-02-01 00:00:00