Abstract:
:This study investigated the presence of adenovirus and norovirus on ward surfaces using real-time polymerase chain reaction (PCR) to assist in the development of evidence-based infection control policy. Screening was carried out weekly for 6 months in the common areas of 2 pediatric wards. Additionally, a one-off screening was undertaken for adenovirus and norovirus on a day unit and for adenovirus only in patient cubicles while occupied. Over the 6-month screening of common areas, 2.4% of samples were positive for adenovirus or norovirus. In rooms occupied with adenovirus-infected children, all cubicle screening sites and almost all swabs were contaminated with adenovirus. In the day unit, 13% of samples were positive. Cleaning and environmental interaction strategies must therefore be designed to control nosocomial transmission of viruses outside of outbreak scenarios.
journal_name
Am J Infect Controljournal_title
American journal of infection controlauthors
Pankhurst L,Cloutman-Green E,Canales M,D'Arcy N,Hartley JCdoi
10.1016/j.ajic.2014.07.028subject
Has Abstractpub_date
2014-11-01 00:00:00pages
1229-32issue
11eissn
0196-6553issn
1527-3296pii
S0196-6553(14)01030-Xjournal_volume
42pub_type
杂志文章abstract::Over the last decade, substantial scientific evidence has accumulated that indicates contamination of environmental surfaces in hospital rooms plays an important role in the transmission of key health care-associated pathogens (eg, methicillin-resistant Staphylococcus aureus, vancomycin-resistant enterococci, Clostrid...
journal_title:American journal of infection control
pub_type: 杂志文章,评审
doi:10.1016/j.ajic.2015.11.015
更新日期:2016-05-02 00:00:00
abstract::One medical center in southern Taiwan faced an outbreak of nosocomial Legionnaires' disease; a total of 81 suspected cases were detected during an 8-month period. Baseline environmental surveillance showed that 80% of the distal sites in intensive care units (ICUs) were positive for Legionella pneumophila. Superheat-a...
journal_title:American journal of infection control
pub_type: 杂志文章
doi:10.1016/j.ajic.2004.12.008
更新日期:2005-12-01 00:00:00
abstract::Catheter-associated urinary tract infections represent a significant medical burden in critically ill children. Ethanol locks have been shown to be effective and safe for central line-associated bloodstream infection prevention and we propose utilizing this strategy for urinary catheters. Because this has never been d...
journal_title:American journal of infection control
pub_type: 杂志文章
doi:10.1016/j.ajic.2015.05.012
更新日期:2015-10-01 00:00:00
abstract:BACKGROUND:Catheter-associated urinary tract infections (CAUTIs) are the most common healthcare-acquired condition. The attributable cost of CAUTIs is frequently cited to be approximately $1,000. However, there is a paucity of recent literature that confirms this estimate. The purpose of this study was to perform a sys...
journal_title:American journal of infection control
pub_type: 杂志文章
doi:10.1016/j.ajic.2018.01.015
更新日期:2018-07-01 00:00:00
abstract:BACKGROUND:Healthcare associated infections are associated with indwelling devices. Yet, data regarding prevalence of indwelling devices in noncritically ill hospitalized patients remains scant. METHODS:Adult, noncritically ill patients on general care, telemetry, and surgical floors at our quaternary care hospital we...
journal_title:American journal of infection control
pub_type: 杂志文章
doi:10.1016/j.ajic.2020.06.205
更新日期:2021-02-01 00:00:00
abstract::In a simultaneous assessment of 250 environmental surfaces after terminal cleaning using aerobic cultures as a gold standard, both fluorescent marker and an adenosine triphosphate bioluminescence assay system demonstrated better diagnosticity compared with subjective visual inspection. These results support the use of...
journal_title:American journal of infection control
pub_type: 杂志文章
doi:10.1016/j.ajic.2012.09.019
更新日期:2013-08-01 00:00:00
abstract::Microbial contamination of used, unprocessed internal components of dental handpieces (HPs) was assessed. HPs were dismantled aseptically, immersed in phosphate-buffered saline, ultrasonicated, and cultured. A median of 200 CFU per turbine (n = 40), 400 CFU per spray channel (n = 40), and 1000 CFU per item of surgical...
journal_title:American journal of infection control
pub_type: 杂志文章
doi:10.1016/j.ajic.2014.06.008
更新日期:2014-09-01 00:00:00
abstract:BACKGROUND:Postoperative wound infection (PWI) after intracranial neurosurgery remains a significant worldwide problem, resulting in substantial morbidity/mortality if not combatted quickly and energetically. Although the danger of PWI is universally recognized, the reported incidence of PWI after intracranial neurosur...
journal_title:American journal of infection control
pub_type: 杂志文章,meta分析
doi:10.1016/j.ajic.2007.07.015
更新日期:2008-10-01 00:00:00
abstract:BACKGROUND:Numerous state health departments (SHDs) have validated central line-associated bloodstream infection (CLABSI) data, and results from these studies provide important insights into the accuracy of CLABSI reporting to the National Healthcare Safety Network (NHSN) and remediable shortcomings in adherence to the...
journal_title:American journal of infection control
pub_type: 杂志文章,评审
doi:10.1016/j.ajic.2018.04.233
更新日期:2018-11-01 00:00:00
abstract:BACKGROUND:Infection control practice compliance is commonly monitored by measuring hand hygiene compliance. The limitations of this approach were recognized in 1 acute health care organization that led to the development of an Infection Control Continuous Quality Improvement tool. METHODS:The Pronovost cycle, Barrier...
journal_title:American journal of infection control
pub_type: 杂志文章
doi:10.1016/j.ajic.2019.06.014
更新日期:2020-01-01 00:00:00
abstract::Urinary tract infections are one of the most common hospital-acquired infections, with 70%-80% resulting from catheter-associated urinary tract infections (CAUTIs). We undertook a qualitative study to assess patient perspectives of indwelling urinary catheters using a semistructured interview. We found that patient aw...
journal_title:American journal of infection control
pub_type: 杂志文章
doi:10.1016/j.ajic.2015.10.011
更新日期:2016-03-01 00:00:00
abstract::We performed 4 years of active screening for multidrug resistant organism (MDRO) colonization among patients with a history of overseas hospitalization. Thirteen (56.5%) of 23 cases were positive for MDROs, which highlights the importance of preemptive infection control to prevent the spread of MDROs in this populatio...
journal_title:American journal of infection control
pub_type: 杂志文章
doi:10.1016/j.ajic.2016.06.040
更新日期:2016-11-01 00:00:00
abstract::Chlorhexidine gluconate (CHG) decreases hospital-acquired methicillin-resistant Staphylococcus aureus (MRSA) that can cause colonization and infection. A standard approach is the bathing of all patients with CHG to prevent MRSA transmission. To decrease CHG utilization, this study assessed selective daily administrati...
journal_title:American journal of infection control
pub_type: 杂志文章
doi:10.1016/j.ajic.2013.12.026
更新日期:2014-05-01 00:00:00
abstract::We aimed to validate quality assurance (QA) criteria for rectal surveillance cultures (RSCs) for extended-spectrum β-lactamase-producing Enterobacteriaceae. QA for RSCs were tested by observing the presence or absence of fecal soiling and by examining the growth of Enterobacteriaceae on MacConkey agar. Extended-spectr...
journal_title:American journal of infection control
pub_type: 杂志文章
doi:10.1016/j.ajic.2017.02.036
更新日期:2017-09-01 00:00:00
abstract:BACKGROUND:Thorough drying of flexible endoscope channels has been identified as an essential reprocessing step. Yet, instructions are not specific on how to dry endoscopes. There is lack of data supporting efficacy of current drying practices, due to limitations in determining channel dryness. METHODS:Novel endoscope...
journal_title:American journal of infection control
pub_type: 杂志文章
doi:10.1016/j.ajic.2020.08.034
更新日期:2020-09-03 00:00:00
abstract:BACKGROUND:Clostridium difficile is the usual and most important cause of antibiotic-associated pseudomembranous enterocolitis. The source of nosocomial acquisition of the organism in nonepidemic settings has not been determined. METHODS:Epidemiologic and microbiologic studies were conducted in a community-teaching ho...
journal_title:American journal of infection control
pub_type: 杂志文章
doi:10.1016/0196-6553(94)90070-1
更新日期:1994-08-01 00:00:00
abstract::The coronavirus pandemic resulted in a shortage of protective equipment. To meet the request of eye-protecting devices, an interdisciplinary consortium involving practitioners, researchers, engineers and technicians developed and manufactured thousands of inexpensive 3D-printed face shields, inside hospital setting. T...
journal_title:American journal of infection control
pub_type: 杂志文章
doi:10.1016/j.ajic.2020.08.005
更新日期:2020-08-11 00:00:00
abstract::From 1988 through 1992, we conducted a prospective study of postdischarge surgical wound infection surveillance in our institution. A total of 6604 patients were seen after discharge in a centralized outpatient clinic, supervised by the infection control commission. Wounds were inspected, stitches were removed, and dr...
journal_title:American journal of infection control
pub_type: 杂志文章
doi:10.1016/0196-6553(95)90059-4
更新日期:1995-10-01 00:00:00
abstract::Sample-size determination is a crucial component of study design. Estimates of sample size are influenced by the amount of change that must occur between study groups and the degree of risk that the investigator is willing to accept in evaluating the null hypothesis. A complete understanding of the impact of sample si...
journal_title:American journal of infection control
pub_type: 杂志文章
doi:10.1016/0196-6553(93)90007-q
更新日期:1993-06-01 00:00:00
abstract:BACKGROUND:Tuberculosis (TB) has re-emerged as a major infectious disease in several areas in the world. Airborne tubercle bacilli produced by individuals with pulmonary TB and droplet nuclei remain suspended in the air for a long time. This study attempts to use a sensitive polymerase chain reaction (PCR) analytic met...
journal_title:American journal of infection control
pub_type: 杂志文章
doi:10.1016/s0196-6553(03)00090-7
更新日期:2004-02-01 00:00:00
abstract:BACKGROUND:Health care workers (HCWs) use their mobile phones during working hours or medical care. There is evidence that the instruments are colonized with pathogenic microorganisms. Here, we describe levels of Enterobacteriaceae contamination (EC) in cell phones and the risk factors associated with EC in Peruvian in...
journal_title:American journal of infection control
pub_type: 杂志文章
doi:10.1016/j.ajic.2016.02.020
更新日期:2016-08-01 00:00:00
abstract:BACKGROUND:Pseudomonas aeruginosa is an important nosocomial pathogen that commonly colonizes hospital water supplies, including in taps and sinks. We report the transmission of P. aeruginosa from water to patients in a clinical hematology setting. METHODS:P. aeruginosa from water samples were compared to clinical iso...
journal_title:American journal of infection control
pub_type: 杂志文章
doi:10.1016/j.ajic.2017.10.013
更新日期:2018-04-01 00:00:00
abstract:BACKGROUND AND OBJECTIVE:Observational studies have suggested an association between diabetes mellitus and the risk of surgical site infections (SSIs), but the results remain inconclusive. We conducted a meta-analysis of prospective cohort studies to elucidate the relationship between diabetes mellitus and SSIs. METHO...
journal_title:American journal of infection control
pub_type: 杂志文章,meta分析
doi:10.1016/j.ajic.2015.04.003
更新日期:2015-08-01 00:00:00
abstract:BACKGROUND:To determine if ending the practice of administering prophylactic antibiotics prior to the placement of totally implantable venous access devices (TIVADs) is correlated with an increase in 30-day bloodstream infection-related TIVADs removals. METHODS:The practice of administering prophylactic antibiotics pr...
journal_title:American journal of infection control
pub_type: 杂志文章
doi:10.1016/j.ajic.2019.06.028
更新日期:2020-01-01 00:00:00
abstract:BACKGROUND:Valid data are a crucial aspect of infection prevention and control programs. The aim of this study was to examine the accuracy of routine reporting in the Iranian Nosocomial Infection Surveillance System in intensive care units. METHODS:A blinded retrospective review of general intensive care unit medical ...
journal_title:American journal of infection control
pub_type: 杂志文章
doi:10.1016/j.ajic.2018.12.028
更新日期:2019-08-01 00:00:00
abstract::A 1-year prospective cohort study of health care-acquired infections was conducted at the neonatal intensive care unit of the University Clinical Centre Kragujevac, Serbia. The incidence rate of neonates with health care-acquired infections was 18.6%, and the incidence rate of the infections themselves was 19.4%. The ...
journal_title:American journal of infection control
pub_type: 杂志文章
doi:10.1016/j.ajic.2014.10.005
更新日期:2015-01-01 00:00:00
abstract:INTRODUCTION:Preoperative nasal mupirocin has been shown to reduce surgical site infections (SSIs) in patients undergoing cardiac surgery. We analyzed the effect of mupirocin plus antiseptic body wash on SSI rate and etiology. METHODS:Prospective SSI surveillance was done for patients undergoing cardiac surgery before...
journal_title:American journal of infection control
pub_type: 杂志文章
doi:10.1016/j.ajic.2015.04.188
更新日期:2015-07-01 00:00:00
abstract:BACKGROUND:A safe alternative to ethylene oxide for reprocessing heat-sensitive lumen medical devices, such as endoscopes, is needed. The effectiveness of a new, safe, low-cost, and environmentally friendly low-temperature sterilization process using ozone was assessed. METHOD:Rigid lumen devices were used to assess t...
journal_title:American journal of infection control
pub_type: 杂志文章
doi:10.1016/j.ajic.2007.06.006
更新日期:2008-05-01 00:00:00
abstract::Bacteria can develop resistance to antibiotics, but little is known about their ability to increase resistance to chemical disinfectants. This study randomly sampled 3 automated endoscope reprocessors in the United States using aldehydes for endoscope disinfection. Bacterial contamination was found after disinfection ...
journal_title:American journal of infection control
pub_type: 杂志文章
doi:10.1016/j.ajic.2011.11.004
更新日期:2012-11-01 00:00:00
abstract:BACKGROUND:We observed an increased rate of Pseudomonas aeruginosa bacteremia in our hematology unit in 2004-2007 without an identified environmental source. METHODS:We conducted a matched case-control study to investigate factors associated with P aeruginosa bacteremia in patients with hematologic malignancies. RESU...
journal_title:American journal of infection control
pub_type: 杂志文章
doi:10.1016/j.ajic.2012.07.012
更新日期:2013-06-01 00:00:00