Hybrid subtraction for improved arteriography.

Abstract:

:A hybrid subtraction method to reduce the motion sensitivity of temporal subtraction for intravenous arteriography is described. Hybrid subtraction uses dual-energy scanned projection radiography to provide pre- and post-contrast images with the soft tissues subtracted. These pre- and post-contrast soft-tissue-cancelled images are then subtracted. Because involuntary motion (such as swallowing or bowel peristalsis) often affects soft tissues primarily, this hybrid technique provides better visualization of carotid and abdominal arteries than temporal or dual-energy subtraction alone.

journal_name

Radiology

journal_title

Radiology

authors

Brody WR

doi

10.1148/radiology.141.3.7029620

subject

Has Abstract

pub_date

1981-12-01 00:00:00

pages

828-31

issue

3

eissn

0033-8419

issn

1527-1315

journal_volume

141

pub_type

杂志文章
  • Liver transplant biopsies with a biopsy gun.

    abstract::The authors evaluated the safety and efficacy of a biopsy gun for performance of image-guided percutaneous biopsy of hepatic allografts in liver transplant recipients. Two hundred fifty-two liver biopsies were performed in 58 transplant recipients over a 27-month period by using this instrument with an 18-gauge needle...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.179.2.2014290

    authors: Chezmar JL,Keith LL,Nelson RC,Plaire JC,Hertzler GL,Bernardino ME

    更新日期:1991-05-01 00:00:00

  • The Effect of Modality and Landmark Selection on MRI and CT Femoral Torsion Angles.

    abstract::Background Assessment of femoral torsion at preoperative hip imaging is commonly recommended. However, it is unclear whether MRI is as accurate as CT and how different methods affect femoral torsion measurements. Purpose To compare MRI- and CT-based assessment of femoral torsion by using four commonly used measurement...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2020192723

    authors: Schmaranzer F,Kallini JR,Miller PE,Kim YJ,Bixby SD,Novais EN

    更新日期:2020-08-01 00:00:00

  • Nerve rootlet avulsion. A complication of myelography using the Chynn needle.

    abstract::The authors report a case of traumatic removal of nerve tissue during myelography with the Chynn aspiration cannula. If such a situation occurs, the authors suggest making a second puncture at a different level. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/125.3.734

    authors: Brodey PA,London SS,Sung MA

    更新日期:1977-12-01 00:00:00

  • Radiology of athletic injuries: football.

    abstract::During a 17-year period, 33 injuries produced radiographic abnormalities in 26 members of a professional football team. Sites of injury were correlated with playing position and protective equipment worn at the time of injury. Fractures of multiple transverse processes of the lumbar spine are reported in offensive hal...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/117.1.33

    authors: Bowerman JW,McDonnell EJ

    更新日期:1975-10-01 00:00:00

  • Adventitial cystic disease of the popliteal artery.

    abstract::In a 27-year-old man with claudication, computed tomography (CT) demonstrated a popliteal cyst and an adventitial cyst of the popliteal artery. Adventitial cystic disease was unexpected because the patient had a diminished pedal pulse on plantar flexion of the foot, a physical finding suggesting popliteal artery entra...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.163.1.3823430

    authors: Jasinski RW,Masselink BA,Partridge RW,Deckinga BG,Bradford PF

    更新日期:1987-04-01 00:00:00

  • Quantitative assessment of para-osteo-arthropathy and its maturation on serial radionuclide bone images.

    abstract::Paraplegics whose range of motion is limited by para-osteo-arthropathy (POA) may have difficulty in becoming independent unless the heterotopic bone mass is removed. The recurrence rate is high if the bony mass is not mature at the time of surgery. Radiography and alkaline phosphatase correlations are not trustworthy....

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/123.1.217

    authors: Tanaka T,Rossier AB,Hussey RW,Ahnberg DS,Treves S

    更新日期:1977-04-01 00:00:00

  • Multiple pulmonary nodules in AIDS: usefulness of CT in distinguishing among potential causes.

    abstract:PURPOSE:To determine whether the computed tomographic (CT) appearances of multiple pulmonary nodules in patients with acquired immunodeficiency syndrome (AIDS) can help differentiate the potential infectious and neoplastic causes. MATERIALS AND METHODS:The thoracic CT scans obtained in 60 patients with AIDS and multip...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.214.2.r00fe22427

    authors: Edinburgh KJ,Jasmer RM,Huang L,Reddy GP,Chung MH,Thompson A,Halvorsen RA Jr,Webb RA

    更新日期:2000-02-01 00:00:00

  • Evaluation of the Patient Request Process for Radiology Imaging in U.S. Hospitals.

    abstract::Background In the United States, patients have the right to access their protected health information. However, to the knowledge of the authors, no study has evaluated the patient request process and the barriers to patient access of their radiology images. Purpose To assess U.S. hospital compliance with federal regul...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2019190473

    authors: Lye CT,Krumholz HM,Eckroate JE,Daniel JG,deBronkart D,Mann MK,Hsiao AL,Forman HP

    更新日期:2019-08-01 00:00:00

  • Extraocular muscles in Graves ophthalmopathy: usefulness of T2 relaxation time measurements.

    abstract:PURPOSE:To determine if T2 relaxation time measurements with magnetic resonance (MR) imaging in patients with Graves ophthalmopathy (GO) can predict response to therapy. MATERIALS AND METHODS:Studied were 84 patients with GO, 27 with Graves disease without ophthalmopathy (GD), and 12 control subjects without Graves di...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.190.3.8115640

    authors: Ohnishi T,Noguchi S,Murakami N,Tajiri J,Harao M,Kawamoto H,Hoshi H,Jinnouchi S,Futami S,Nagamachi S

    更新日期:1994-03-01 00:00:00

  • Colorectal tumor vascularity: quantitative assessment with multidetector CT--do tumor perfusion measurements reflect angiogenesis?

    abstract:PURPOSE:To establish the relationships between quantitative perfusion computed tomography (CT) parameters-specifically, primary tumor blood flow, blood volume, transit time, and permeability surface-area product-and immunohistologic markers of angiogenesis in colorectal cancer. MATERIALS AND METHODS:After institutiona...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2492071365

    authors: Goh V,Halligan S,Daley F,Wellsted DM,Guenther T,Bartram CI

    更新日期:2008-11-01 00:00:00

  • Evaluation of Quantitative PET/MR Enterography Biomarkers for Discrimination of Inflammatory Strictures from Fibrotic Strictures in Crohn Disease.

    abstract:PURPOSE:To retrospectively evaluate positron emission tomography (PET)/magnetic resonance (MR) enterography for the differentiation of fibrotic strictures from inflammatory strictures in patients with Crohn disease. MATERIALS AND METHODS:This HIPAA-compliant retrospective study was approved by the institutional review...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2015150566

    authors: Catalano OA,Gee MS,Nicolai E,Selvaggi F,Pellino G,Cuocolo A,Luongo A,Catalano M,Rosen BR,Gervais D,Vangel MG,Soricelli A,Salvatore M

    更新日期:2016-03-01 00:00:00

  • Endorectal MR imaging in the evaluation of seminal vesicle invasion: diagnostic accuracy and multivariate feature analysis.

    abstract:PURPOSE:To retrospectively determine the accuracy of endorectal magnetic resonance (MR) imaging in demonstrating seminal vesicle invasion (SVI) and to investigate the MR imaging features that can predict SVI. MATERIALS AND METHODS:The Institutional Review Board granted exempt status for this retrospective study, with ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2383050657

    authors: Sala E,Akin O,Moskowitz CS,Eisenberg HF,Kuroiwa K,Ishill NM,Rajashanker B,Scardino PT,Hricak H

    更新日期:2006-03-01 00:00:00

  • Noxious somatosensory stimulation affects the default mode of brain function: evidence from functional MR imaging.

    abstract:PURPOSE:To investigate whether default mode network (DMN) spatial properties can be directly affected by pain, with a comparison of painful and nonpainful conditions. MATERIALS AND METHODS:The authors performed a functional magnetic resonance (MR) imaging study, approved by the local institutional ethics committee, in...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2533090602

    authors: Mantini D,Caulo M,Ferretti A,Romani GL,Tartaro A

    更新日期:2009-12-01 00:00:00

  • Lymphography without the use of vital dyes.

    abstract::Pedal lymphography was performed without the use of vital dyes in 510 patients. Lymphatic vessels were still readily identifiable by this method, due to their transparency, clarity, elasticity, distensibility, and characteristic branching pattern. Procedure time was shortened by 10-15 minutes without compromising the ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/133.3.795

    authors: Kapdi CC

    更新日期:1979-12-01 00:00:00

  • The changing role of external-beam irradiation in the management of malignant tumors of the major salivary glands.

    abstract::Postoperative irradiation reduces the local recurrence rate for malignant salivary gland tumors. Less extensive surgery followed by immediate radiotherapy is possible without decreasing local control; moreover, cosmetic appearance and physiological function are preserved. Local tumor control was achieved in 16 out of ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.145.1.6812160

    authors: Chung CT,Sagerman RH,Ryoo MC,King GA,Yu WS,Dalal PS

    更新日期:1982-10-01 00:00:00

  • Ablation of osteoid osteomas with a percutaneously placed electrode: a new procedure.

    abstract::Osteoid osteoma is a benign, self-limited tumor of bone that usually requires surgical excision for relief of pain and to prevent long-term consequences. Radio-frequency electrodes have been successfully and safely used to ablate small areas of the central nervous system and to perform ablation elsewhere in the body. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.183.1.1549690

    authors: Rosenthal DI,Alexander A,Rosenberg AE,Springfield D

    更新日期:1992-04-01 00:00:00

  • Method to control spraying of high-velocity infected blood droplets during arterial catheterization.

    abstract::Spurting of blood from standard arterial needles during guide-wire insertion can be controlled easily with a syringe and a simple needle inserted along the syringe plunger. With this method, blood droplets that may be infected with the hepatitis or human immunodeficiency virus will not come into contact with the head ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.174.3.174-3-1055

    authors: Cope C,Machan L

    更新日期:1990-03-01 00:00:00

  • Radiation-induced decrease in nitric oxide synthase--containing nerves in the rat penis.

    abstract:PURPOSE:Evaluate effect of prostatic irradiation on erectile function. MATERIALS AND METHODS:Forty-seven male adult rats were divided into three groups according to a single radiation dose to the prostate: control (no irradiation) (n = 15), 1,000 cGy (n = 15), and 2,000 cGy (n = 17). Five months after irradiation, rat...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.195.1.7534430

    authors: Carrier S,Hricak H,Lee SS,Baba K,Morgan DM,Nunes L,Ross GY,Phillips TL,Lue TF

    更新日期:1995-04-01 00:00:00

  • Early measurement of pulsatility and resistive indexes: correlation with long-term renal transplant function.

    abstract:PURPOSE:To correlate pulsatility index (PI) and resistive index (RI) measured at early specific intervals after transplantation with 1-year estimated glomerular filtration rate (eGFR) and death-censored transplant survival to assess the long-term prognostic value of these Doppler indexes. MATERIALS AND METHODS:The loc...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.10101329

    authors: McArthur C,Geddes CC,Baxter GM

    更新日期:2011-04-01 00:00:00

  • Therapeutic blockade of arteries using compressed Ivalon.

    abstract::A new technique for embolization with compressed Ivalon plugs is described. Fourteen arteries--six renal, three splenic, two pulmonary, one left gastric, and two abdominal aortas--were occluded in six dogs. In one case of renal artery embolization, three plugs were used, and in one case of abdominal aorta embolization...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.136.3.7403540

    authors: Zollikofer C,Castaneda-Zuniga WR,Galliani C,Rysavy JA,Formanek A,Amplatz K

    更新日期:1980-09-01 00:00:00

  • Computed tomography in cerebral abscess.

    abstract::Computed tomography (CT) scans of 9 surgically proved cases of cerebral abscess were reviewed. The CT characteristics were studied, as were the postoperative scans. Also assessed were the contributions to the diagnosis of the clinical features, plain radiographic examinations, radionuclide imaging, and angiography. Th...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/121.3.641

    authors: New PF,Davis KR,Ballantine HT Jr

    更新日期:1976-12-01 00:00:00

  • Indwelling ureteral stents: percutaneous management of complications.

    abstract::Complications of indwelling ureteral stents were managed percutaneously in 13 patients. These complications consisted of three fractured, three heavily encrusted, and seven migrated stents. While most ureteral stent malfunctions are routinely managed with retrograde techniques, the percutaneous approach allows effecti...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.158.1.3510020

    authors: LeRoy AJ,Williams HJ Jr,Segura JW,Patterson DE,Benson RC Jr

    更新日期:1986-01-01 00:00:00

  • Synthetic ossicular replacements: normal and abnormal CT appearance.

    abstract::Twenty-two patients with synthetic ossicular replacements were studied with computed tomography (CT). Twelve patients had total ossicular replacement prostheses (TORPs), and ten patients had partial ossicular replacement prostheses (PORPs). Good results were achieved in 12 patients (eight with TORPs and four with PORP...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.163.3.3575730

    authors: Swartz JD,Berger AS,Zwillenberg S,Granoff DW,Popky GL

    更新日期:1987-06-01 00:00:00

  • Pulmonary embolus: detection and follow-up using magnetic resonance.

    abstract::Magnetic resonance imaging (MRI) of an angiographically confirmed pulmonary embolus was performed. The thrombus appeared as an intense intraluminal signal within the left descending pulmonary artery; this signal was absent on repeat examination after clot lysis. Because MR will not image flowing blood, it provides a p...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.153.2.6484180

    authors: Moore EH,Gamsu G,Webb WR,Stulbarg MS

    更新日期:1984-11-01 00:00:00

  • Prostate cancer: relationships between postbiopsy hemorrhage and tumor detectability at MR diagnosis.

    abstract:PURPOSE:To retrospectively evaluate the influence of postbiopsy hemorrhage on the accuracy of tumor detection at T2-weighted magnetic resonance (MR) imaging, dynamic contrast material-enhanced MR imaging, and diffusion-weighted (DW) MR imaging of prostate cancer, with histologic findings as the reference standard. MAT...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2482070157

    authors: Tamada T,Sone T,Jo Y,Yamamoto A,Yamashita T,Egashira N,Imai S,Fukunaga M

    更新日期:2008-08-01 00:00:00

  • Endovascular versus open surgical elective repair of infrarenal abdominal aortic aneurysm: predictors of patient discharge destination.

    abstract:PURPOSE:To evaluate patient discharge destination after elective endovascular or open surgical repair of infrarenal abdominal aortic aneurysm and to determine predictors for discharge to home or to a rehabilitation center. MATERIALS AND METHODS:All patients electively treated for infrarenal abdominal aortic aneurysm w...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2202010147

    authors: Bosch JL,Beinfeld MT,Halpern EF,Lester JS,Gazelle GS

    更新日期:2001-09-01 00:00:00

  • Differentiation of Recurrent Glioblastoma from Delayed Radiation Necrosis by Using Voxel-based Multiparametric Analysis of MR Imaging Data.

    abstract::Purpose To assess a volume-weighted voxel-based multiparametric (MP) clustering method as an imaging biomarker to differentiate recurrent glioblastoma from delayed radiation necrosis. Materials and Methods The institutional review board approved this retrospective study and waived the informed consent requirement. Sev...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2017161588

    authors: Yoon RG,Kim HS,Koh MJ,Shim WH,Jung SC,Kim SJ,Kim JH

    更新日期:2017-10-01 00:00:00

  • Thermography, mammography, and clinical examination in breast cancer screening. Review of 16,000 studies.

    abstract::Breast cancer screening detected 139 biopsy-proved malignancies in 16,000 slef-selected women (8.7/1,000). In these, xeroradiography detected 78% (109), clinical examination 55% (76), and thermography 39% (54). In all 16,000 women, the thermogram was interpreted as positive in 17.9% (2,864). The greatest effectiveness...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/122.1.123

    authors: Feig SA,Shaber GS,Schwartz GF,Patchefsky A,Libshitz HI,Edeiken J,Nerlinger R,Curley RF,Wallace JD

    更新日期:1977-01-01 00:00:00

  • Transbronchial biopsy with virtual CT bronchoscopy and nodal highlighting.

    abstract::Transbronchial biopsy to sample lymph nodes and tumors that are not visible at endoscopy has a poor (<50%) success rate. These nodes can be highlighted easily at virtual computed tomographic (CT) bronchoscopy to provide a guide. This study was performed to evaluate if the addition of this information to the bronchosco...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2211001585

    authors: Hopper KD,Lucas TA,Gleeson K,Stauffer JL,Bascom R,Mauger DT,Mahraj R

    更新日期:2001-11-01 00:00:00

  • Acute appendicitis: high-resolution real-time US findings.

    abstract::High-resolution, real-time ultrasonography (US) with graded compression was used to evaluate 90 patients with clinically suspected acute appendicitis. US visualization of a noncompressible appendix was the primary criterion for a diagnosis of acute appendicitis. The overall sensitivity was 89%, the specificity was 95%...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.163.1.3547490

    authors: Jeffrey RB Jr,Laing FC,Lewis FR

    更新日期:1987-04-01 00:00:00