Calculation of van't Hoff enthalpy associated with aspirin-induced change in liposomal membrane anisotropy.

Abstract:

:The lipid disordering effect of aspirin on the liposomal membrane of dipalmitoyl phosphatidyl choline has recently been studied using the fluorescence polarization method. From the anisotropy-temperature curve, we have calculated here the associated change in van't Hoff enthalpy. Since the fluorescence technique requires a very small amount of sample (10(-4) M), this method of enthalpy calculation compares well and is advantageous over the standard calorimetric methods.

journal_name

Phys Med Biol

authors

De S,Ghosh AK,Basu R,Nandy P

doi

10.1088/0031-9155/41/3/003

subject

Has Abstract

pub_date

1996-03-01 00:00:00

pages

383-6

issue

3

eissn

0031-9155

issn

1361-6560

journal_volume

41

pub_type

杂志文章
  • MR-based keyhole SPECT for small animal imaging.

    abstract::The rationale for multi-modality imaging is to integrate the strengths of different imaging technologies while reducing the shortcomings of an individual modality. The work presented here proposes a limited-field-of-view (LFOV) SPECT reconstruction technique that can be implemented on a multi-modality MR/SPECT system ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/3/010

    authors: Lee KS,Roeck WW,Gullberg GT,Nalcioglu O

    更新日期:2011-02-07 00:00:00

  • Feasibility of salvage interstitial microwave thermal therapy for prostate carcinoma following failed brachytherapy: studies in a tissue equivalent phantom.

    abstract::Thermal therapy is an experimental treatment to destroy solid tumours by heating them to temperatures ranging from 55 degrees C to 90 degrees C, inducing thermal coagulation and necrosis of the tumour. We are investigating the feasibility of interstitial microwave thermal therapy as a salvage treatment for prostate ca...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/48/8/306

    authors: McCann C,Kumaradas JC,Gertner MR,Davidson SR,Dolan AM,Sherar MD

    更新日期:2003-04-21 00:00:00

  • An automated, fast and accurate registration method to link stranded seeds in permanent prostate implants.

    abstract::The geometry of a permanent prostate implant varies over time. Seeds can migrate and edema of the prostate affects the position of seeds. Seed movements directly influence dosimetry which relates to treatment quality. We present a method that tracks all individual seeds over time allowing quantification of seed moveme...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/20/N391

    authors: Westendorp H,Nuver TT,Moerland MA,Minken AW

    更新日期:2015-10-21 00:00:00

  • Effect of blood perfusion on the ablation of liver parenchyma with high-intensity focused ultrasound.

    abstract::This paper discusses the effect of blood perfusion on the ablation of rat liver tissue with high-intensity focused ultrasound (HIFU). For this study a practical method has been developed, in which the liver blood flow can be reduced by ligation of the hepatic artery and portal vein. During the treatment the rat liver ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/38/11/011

    authors: Chen L,ter Haar G,Hill CR,Dworkin M,Carnochan P,Young H,Bensted JP

    更新日期:1993-11-01 00:00:00

  • A finite element method for the determination of the relative response of ionization chambers in MR-linacs: simulation and experimental validation up to 1.5 T.

    abstract::In magnetic resonance (MR) guided radiotherapy, the magnetic field-dependent change in the dose response of ionization chambers is typically included by means of a correction factor [Formula: see text]. This factor can be determined experimentally or calculated by means of Monte Carlo (MC) simulations. To date, a smal...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab2837

    authors: Pojtinger S,Kapsch RP,Dohm OS,Thorwarth D

    更新日期:2019-07-04 00:00:00

  • Regional deep hyperthermia: impact of observer variability in CT-based manual tissue segmentation on simulated temperature distribution.

    abstract::The aim of this study was to systematically investigate the influence of the inter- and intra-observer segmentation variation of tumors and organs at risk on the simulated temperature coverage of the target. CT scans of six patients with tumors in the pelvic region acquired for radiotherapy treatment planning were use...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa685b

    authors: Aklan B,Hartmann J,Zink D,Siavooshhaghighi H,Merten R,Putz F,Ott O,Fietkau R,Bert C

    更新日期:2017-05-08 00:00:00

  • Effects of pulmonary inhalation on hyperpolarized krypton-83 magnetic resonance T1 relaxation.

    abstract::The (83)Kr magnetic resonance (MR) relaxation time T(1) of krypton gas in contact with model surfaces was previously found to be highly sensitive to surface composition, surface-to-volume ratio, and surface temperature. The work presented here explored aspects of pulmonary (83)Kr T(1) relaxation measurements in excise...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/56/13/001

    authors: Stupic KF,Elkins ND,Pavlovskaya GE,Repine JE,Meersmann T

    更新日期:2011-07-07 00:00:00

  • Dosimetric and workflow evaluation of first commercial synthetic CT software for clinical use in pelvis.

    abstract::To evaluate a commercial synthetic CT (syn-CT) software for use in prostate radiotherapy. Twenty-five prostate patients underwent CT and MR simulation scans in treatment position on a 3T MR scanner. A commercially available MR protocol was used that included a T2w turbo spin-echo sequence for soft-tissue contrast and ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa5452

    authors: Tyagi N,Fontenla S,Zhang J,Cloutier M,Kadbi M,Mechalakos J,Zelefsky M,Deasy J,Hunt M

    更新日期:2017-04-21 00:00:00

  • The first visualization of chemotherapy-induced tumor apoptosis via magnetic particle imaging in a mouse model.

    abstract::Imaging technologies that allow non-radiative visualization and quantification of apoptosis have a great potential for assessing therapy response, early diagnosis, and disease monitoring. Magnetic particle imaging (MPI), the direct imaging of magnetic nanoparticles as positive contrast agent and sole signal source, en...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/abad7c

    authors: Liang X,Wang K,Du J,Tian J,Zhang H

    更新日期:2020-09-24 00:00:00

  • Optimisation of field flatness and depth-dose for therapy electron beams.

    abstract::Curves relating beam energy, scattering foil thickness, central-axis depth-dose, and beam flatness have been generated using data taken on a Siemens 200A betatron. The curve set allows a single combination of tungsten foil thickness and electron beam energy to be chosen that will provide the optimum depth-dose distrib...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/26/3/007

    authors: Marbach JR,Almond PR

    更新日期:1981-05-01 00:00:00

  • Reconsideration of the backscatter components in the intermediate cavity theory for photon beams.

    abstract::Cavity theories are used to relate the dose in a medium to the dose in a cavity. No satisfactory analytical approach exists for the case of intermediate cavities, such as TLDs, when interface effects are important. Burlin proposed a general cavity theory that accounts for the cavity size but which ignores interface ef...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/46/4/320

    authors: Frujinoiu C

    更新日期:2001-04-01 00:00:00

  • Coupled thermo-electro-mechanical models for thermal ablation of biological tissues and heat relaxation time effects.

    abstract::Thermal ablation is a widely applied electrosurgical process in medical treatment of soft biological tissues. Numerical modeling and simulations play an important role in prediction of temperature distribution and damage volume during the treatment planning stage of associated therapies. In this contribution we report...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab4cc5

    authors: Singh S,Melnik R

    更新日期:2019-12-13 00:00:00

  • Spectral phase-based automatic calibration scheme for swept source-based optical coherence tomography systems.

    abstract::The automatic calibration in Fourier-domain optical coherence tomography (FD-OCT) systems allows for high resolution imaging with precise depth ranging functionality in many complex imaging scenarios, such as microsurgery. However, the accuracy and speed of the existing automatic schemes are limited due to the functio...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/21/7652

    authors: Ratheesh KM,Seah LK,Murukeshan VM

    更新日期:2016-11-07 00:00:00

  • Estimation of tissue resistivities from multiple-electrode impedance measurements.

    abstract::In order to measure in vivo resistivity of tissues in the thorax, the possibility of combining anatomical data extracted from high-resolution images with multiple-electrode impedance measurements, a priori knowledge of the range of tissue resistivities, and a priori data on the instrumentation noise is assessed in thi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/39/1/001

    authors: Eyüboğlu BM,Pilkington TC,Wolf PD

    更新日期:1994-01-01 00:00:00

  • Automated cell cycle analysis with fluorescence microscopy and image analysis.

    abstract::Automatic cell cycle analysis (DNA histograms) is usually performed with flow cytometry. In cases when only few cells are available, the DNA content has to be measured with a fluorescence microscope combined with sensitive camera systems (SIT, MCP, cooled CCDs) and a frame grabber for image analysis. The fluorescent c...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/41/3/013

    authors: Böcker W,Gantenberg HW,Müller WU,Streffer C

    更新日期:1996-03-01 00:00:00

  • Dosimetry for the MRI accelerator: the impact of a magnetic field on the response of a Farmer NE2571 ionization chamber.

    abstract::The UMC Utrecht is constructing a 1.5 T MRI scanner integrated with a linear accelerator (Lagendijk et al 2008 Radiother. Oncol. 86 25-9). The goal of this device is to facilitate soft-tissue contrast based image-guided radiotherapy, in order to escalate the dose to the tumour while sparing surrounding normal tissues....

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/10/002

    authors: Meijsing I,Raaymakers BW,Raaijmakers AJ,Kok JG,Hogeweg L,Liu B,Lagendijk JJ

    更新日期:2009-05-21 00:00:00

  • Trimmer sequencing time minimization during dynamically collimated proton therapy using a colony of cooperating agents.

    abstract::The dynamic collimation system (DCS) can be combined with pencil beam scanning proton therapy to deliver highly conformal treatment plans with unique collimation at each energy layer. This energy layer-specific collimation is accomplished through the synchronized motion of four trimmer blades that intercept the proton...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/ab416d

    authors: Smith BR,Hyer DE,Flynn RT,Hill PM,Culberson WS

    更新日期:2019-10-21 00:00:00

  • Optical-thermal characterization of cutaneous transilluminators.

    abstract::In recent years, there has been an increase in the popularity of light-emitting diode (LED)-based, battery-powered transilluminators (BPTs) for facilitating transdermal vascular access in adults and neonates. BPTs are believed to have lower potential for inducing skin burns than prior devices based on high-power broad...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/54/22/008

    authors: Pfefer TJ,Mehrabi A,James R,Landry R,Weininger S,Chang I,Kaufman D,Miller S

    更新日期:2009-11-21 00:00:00

  • A phantom for the testing and calibration of near infra-red spectrometers.

    abstract::This note describes a simple phantom which can be used to check the long term stability and accuracy of relative attenuation measurements made by near infra-red (NIR) spectrometers. The phantom has been calibrated, and the results of the calibration are shown to agree with theoretical predictions of the relative atten...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/39/9/015

    authors: Firbank M,Delpy DT

    更新日期:1994-09-01 00:00:00

  • W values and other transport data on low energy electrons in tissue equivalent gas.

    abstract::The degradation of low energy electrons in a methane based, tissue equivalent gas was studied experimentally by ionization chamber experiments and theoretically by Monte Carlo electron transport simulation in the energy range between 25 eV and 5 keV. From measured ionization yields and calculated ionization and energy...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/37/5/008

    authors: Waibel E,Grosswendt B

    更新日期:1992-05-01 00:00:00

  • GGEMS-Brachy: GPU GEant4-based Monte Carlo simulation for brachytherapy applications.

    abstract::In brachytherapy, plans are routinely calculated using the AAPM TG43 formalism which considers the patient as a simple water object. An accurate modeling of the physical processes considering patient heterogeneity using Monte Carlo simulation (MCS) methods is currently too time-consuming and computationally demanding ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/60/13/4987

    authors: Lemaréchal Y,Bert J,Falconnet C,Després P,Valeri A,Schick U,Pradier O,Garcia MP,Boussion N,Visvikis D

    更新日期:2015-07-07 00:00:00

  • Film dosimetry using a smart device camera: a feasibility study for point dose measurements.

    abstract::In this work, a methodology for using a smartphone camera, in conjunction with a light-tight box operating in reflective transmission mode, is investigated as a proof of concept for use as a film dosimetry system. An imaging system was designed to allow the camera of a smartphone to be used as a pseudo densitometer. T...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/1361-6560/aa8b36

    authors: Aland T,Jhala E,Kairn T,Trapp J

    更新日期:2017-10-03 00:00:00

  • Four-dimensional Monte Carlo simulation of time-dependent geometries.

    abstract::Dynamic radiation therapy techniques require that the treatment head setup varies in time and space during dose delivery. Examples are leaf motion in intensity modulated x-ray therapy, modulator wheel rotation in conventional proton therapy and variable magnet settings in proton beam scanning. Consequently, for Monte ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/49/6/n03

    authors: Paganetti H

    更新日期:2004-03-21 00:00:00

  • An exponential growth of computational phantom research in radiation protection, imaging, and radiotherapy: a review of the fifty-year history.

    abstract::Radiation dose calculation using models of the human anatomy has been a subject of great interest to radiation protection, medical imaging, and radiotherapy. However, early pioneers of this field did not foresee the exponential growth of research activity as observed today. This review article walks the reader through...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章,评审

    doi:10.1088/0031-9155/59/18/R233

    authors: Xu XG

    更新日期:2014-09-21 00:00:00

  • Ion concentration and haematocrit as determinants of impedance in an erythrocyte suspension model of renal medullary tissue.

    abstract::In order to analyse the respective roles of ion concentration and fractional volume of the interstitial compartment as determinants of the impedance, Z, of renal medullary tissue, a model was needed in which both these factors could be varied independently. An array of blood cell suspensions ions in saline (different ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/35/11/011

    authors: Niewiadomski W,Sadowski J,Badzyńska B,Rasmussen SN

    更新日期:1990-11-01 00:00:00

  • In vivo electric conductivity of cervical cancer patients based on B₁⁺ maps at 3T MRI.

    abstract::The in vivo electric conductivity (σ) values of tissue are essential for accurate electromagnetic simulations and specific absorption rate (SAR) assessment for applications such as thermal dose computations in hyperthermia. Currently used σ-values are mostly based on ex vivo measurements. In this study the conductivit...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/4/1596

    authors: Balidemaj E,de Boer P,van Lier AL,Remis RF,Stalpers LJ,Westerveld GH,Nederveen AJ,van den Berg CA,Crezee J

    更新日期:2016-02-21 00:00:00

  • Monte Carlo calculations of beam quality correction factors kQ for electron dosimetry with a parallel-plate Roos chamber.

    abstract::Current dosimetry protocols (AAPM, IAEA, DIN) recommend the use of parallel-plate ionization chambers for the measurement of absorbed dose-to-water in clinical electron beams. For well-guarded plane-parallel chambers, it is assumed that the perturbation correction pQ is unity for all electron energies. In this study, ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/6/006

    authors: Zink K,Wulff J

    更新日期:2008-03-21 00:00:00

  • Time-invariant component-based normalization for a simultaneous PET-MR scanner.

    abstract::Component-based normalization is a method used to compensate for the sensitivity of each of the lines of response acquired in positron emission tomography. This method consists of modelling the sensitivity of each line of response as a product of multiple factors, which can be classified as time-invariant, time-varian...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/61/9/3554

    authors: Belzunce MA,Reader AJ

    更新日期:2016-05-07 00:00:00

  • Stochastic versus deterministic kernel-based superposition approaches for dose calculation of intensity-modulated arcs.

    abstract::Dose calculations for radiation arc therapy are traditionally performed by approximating continuous delivery arcs with multiple static beams. For 3D conformal arc treatments, the shape and weight variation per degree is usually small enough to allow arcs to be approximated by static beams separated by 5 degrees -10 de...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/53/17/018

    authors: Tang G,Earl MA,Luan S,Wang C,Cao D,Yu CX,Naqvi SA

    更新日期:2008-09-07 00:00:00

  • Absorbed dose determination at short distance from 60Co and 192Ir brachytherapy sources.

    abstract::This paper presents two methods for absorbed dose determination with ionization chambers at short distance from 60Co and 192Ir brachytherapy sources. The methods are modifications of the Bragg-Gray and large cavity principles given in the IAEA code of practice for high- and medium-energy photon beams. A non-uniformity...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/43/11/002

    authors: Tölli H,Johansson KA

    更新日期:1998-11-01 00:00:00