MR-guided freehand biopsy of liver lesions with fast continuous imaging using a 1.0-T open MRI scanner: experience in 50 patients.

Abstract:

:The purpose of this study was to assess a new open system with a field-strength of 1.0 T for the feasibility of liver biopsy using the freehand technique with fast continuous imaging. Fifty patients with focal liver lesions measuring 5 to 30 mm in diameter were included in the study. Guidance and monitoring was performed using a 1.0-T open magnetic resonance (MR) scanner (Panorama HFO; Philips Healthcare, Best, The Netherlands). With fast continuous imaging using a T1-weighted (T1W) gradient echo (GRE) sequence after administration of gadolinium (Gd)-EOB-DTPA, the needle was placed into the lesion. An interface for interactive dynamic viewing in two perpendicular planes prevented needle deviations T2-weighted turbo spin echo (TSE) fat-suppressed sequence was added to rule out postinterventional hematoma or biloma. All lesions were visible on the interventional images. Biopsy was technically successful, and solid specimens were obtained in all cases. Forty-six patients showed a histopathologic pattern other than native liver tissue, thus confirming correct position of the needle. Time between determination of the lesion and performance of the control scan was on average 18 min. No major complications were recorded. MR guidance with the new 1-T open system must be considered an attractive alternative for liver punction. An interface for dynamic imaging of needle guidance and T1W-GRE imaging with administration of Gd-EOB-DTPA for contrast enhancement allows the pinpoint puncture of liver lesions.

authors

Fischbach F,Bunke J,Thormann M,Gaffke G,Jungnickel K,Smink J,Ricke J

doi

10.1007/s00270-010-9836-8

subject

Has Abstract

pub_date

2011-02-01 00:00:00

pages

188-92

issue

1

eissn

0174-1551

issn

1432-086X

journal_volume

34

pub_type

杂志文章
  • Two cases of spontaneous lysis of arterial thrombi.

    abstract::Two cases of spontaneous lysis of arterial thrombi are described. The occurrence of spontaneous thrombolysis and the relative ease of performing Fogarty embolectomy (thrombectomy) in peripheral arteries should be considered along with the clinical status of a patient who is viewed as a possible candidate for thromboly...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02552672

    authors: Weiner MA,Sniderman KW,Sos TA,Saddekni S,Silane M

    更新日期:1984-01-01 00:00:00

  • Volumetric analysis of right ventricular cadaver models viewed in axially angled projections.

    abstract::Axial cinematography of 15 cadaver cast models of the right ventricle was performed, using 16 different real and simulated single and biplane axial oblique projections. Heart volumes were then calculated by Dodge's area-length method and Ferlinz' method. In our volumetric studies of models, the smallest positive devia...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02552633

    authors: Dübel HP,Romaniuk P,Tschapek A

    更新日期:1985-01-01 00:00:00

  • Permanent indwelling peritoneal access device for the management of malignant ascites.

    abstract::The case presented demonstrates an alternative management approach for malignant ascites. A permanent indwelling peritoneal port for at-home, small-volume paracentesis, provided palliative therapy for a patient who had malignant ascites secondary to breast cancer. The device allowed paracentesis without the risk of re...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF00192454

    authors: Sabatelli FW,Glassman ML,Kerns SR,Hawkins IF Jr

    更新日期:1994-09-01 00:00:00

  • A system for computer-assisted design of stent-grafts for aortic aneurysms using 3-D morphological models.

    abstract::A three-dimensional model was constructed from helical CT images for abdominal aortic aneurysm (AAA) and thoracic aortic aneurysm (TAA). A stent-graft was designed and positioned endoluminally on the computer. One hundred and nine stent-grafts for 101 patients were designed by this method and deployed well in all pati...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-001-0383-8

    authors: Imai Y,Urayama S,Uyama C,Inoue K,Ueno K,Kuribayashi S,Takamiya M,Hamada S,Hirane Y

    更新日期:2001-07-01 00:00:00

  • Nasolacrimal polyurethane stent: complications with CT correlation.

    abstract:PURPOSE:To evaluate initial results in patients with epiphora secondary to obstruction of the nasolacrimal duct treated by placement of a polyurethane stent, and to discuss the technical problems and complications arising during the procedure, with visualization of the anatomy of the drainage apparatus using computed t...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 临床试验,杂志文章

    doi:10.1007/s002709900302

    authors: Pinto IT,Paul L,Grande C

    更新日期:1998-11-01 00:00:00

  • Post-stenting intravascular brachytherapy trials on hypercholesterolemic rabbits using 32P liquid sources: implications for prevention of in-stent restenosis.

    abstract:PURPOSE:Liquid sources of radiation delivered in angioplasty balloons may be a convenient self-centering device used for prevention of in-stent restenosis. To test the effectiveness of this method an intravascular brachytherapy study was performed using 32P liquid sources in an animal model. METHODS:The radial dose di...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-002-1879-z

    authors: Wilczek K,Walichiewicz P,Petelenz B,Jache W,Jochem J,Tomasik A,Bilski P,Snietura M,Wodniecki J

    更新日期:2002-07-01 00:00:00

  • Injection-associated pain in femoral arteriography: a European multicenter study comparing safety, tolerability, and efficacy of iodixanol and iopromide.

    abstract:PURPOSE:To evaluate injection-associated pain, safety, and efficacy with the isotonic contrast medium iodixanol (Visipaque 270 mg I/ml) compared with iopromide (Ultravist 300 mg I/ml) in femoral arteriography. METHODS:A multicenter, double-blind, randomized, parallel-group clinical investigation was carried out in 54 ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1007/s002709900147

    authors: Justesen P,Downes M,Grynne BH,Lang H,Rasch W,Seim E

    更新日期:1997-07-01 00:00:00

  • Radioembolization dosimetry: the road ahead.

    abstract::Methods for calculating the activity to be administered during yttrium-90 radioembolization (RE) are largely based on empirical toxicity and efficacy analyses, rather than dosimetry. At the same time, it is recognized that treatment planning based on proper dosimetry is of vital importance for the optimization of the ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00270-014-1042-7

    authors: Smits ML,Elschot M,Sze DY,Kao YH,Nijsen JF,Iagaru AH,de Jong HW,van den Bosch MA,Lam MG

    更新日期:2015-04-01 00:00:00

  • Sacroiliac Joint Ablation Using MR-HIFU.

    abstract::The sacroiliac joint is the culprit in 15-30% of patients with chronic lumbar back pain. Ablation of the posterior sensory nerves supplying the joint is an established treatment option before arthrodesis. We report the successful application of MR-HIFU in a patient with therapy-refractory pain using the Sonalleve MR-H...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-019-02263-0

    authors: Najafi A,Sartoretti E,Binkert CA

    更新日期:2019-09-01 00:00:00

  • Transarterial (Chemo-)Embolization and Lipiodolization for Hepatic Haemangioma.

    abstract:BACKGROUND:Transarterial (chemo-)embolization/lipiodolization (TAE/TAL) might be an attractive minimally invasive alternative to surgery in the treatment of symptomatic hepatic haemangioma. This review assesses the efficacy and safety of TAE/TAL as primary treatment for symptomatic hepatic haemangioma. METHODS:A syste...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00270-019-02169-x

    authors: Furumaya A,van Rosmalen BV,Takkenberg RB,van Delden OM,Dejong CHC,Verheij J,van Gulik TM

    更新日期:2019-06-01 00:00:00

  • Access to the superficial femoral artery in the presence of a "hostile groin": a prospective study.

    abstract:PURPOSE:Lower limb angioplasty is commonly performed via antegrade common femoral artery (CFA) puncture, followed by selective superficial femoral artery (SFA) catheterization. Arterial access can be complicated by a "hostile groin" (scarring, obesity, or previous failed CFA puncture). We prospectively investigated col...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-005-0347-y

    authors: Marcus AJ,Lotzof K,Howard A

    更新日期:2007-05-01 00:00:00

  • Endovascular broad-neck aneurysm creation in a porcine model using a vascular plug.

    abstract:PURPOSE:Ruptured cerebral arterial aneurysms require prompt treatment by either surgical clipping or endovascular coiling. Training for these sophisticated endovascular procedures is essential and ideally performed in animals before their use in humans. Simulators and established animal models have shown drawbacks with...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-012-0431-z

    authors: Mühlenbruch G,Nikoubashman O,Steffen B,Dadak M,Palmowski M,Wiesmann M

    更新日期:2013-02-01 00:00:00

  • Transarterial Ethanol Ablation for Small Hepatocellular Carcinoma (≤ 3 cm): A Comparative Study Versus Radiofrequency Ablation.

    abstract:PURPOSE:The objective was to evaluate the local treatment efficacy of transarterial ethanol ablation (TEA) as compared to radiofrequency ablation (RFA) for small hepatocellular carcinoma (HCC). MATERIALS AND METHODS:This was a retrospective study between January 2005 and April 2017, in which the treatment outcomes of ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-020-02426-4

    authors: Yu SCH,Hui JWY,Chong CCN,Chu CM,Cheung S,Wong J,Lee KF

    更新日期:2020-05-01 00:00:00

  • Utility of covered stents for revision of aging failing synthetic hemodialysis grafts: a report of three cases.

    abstract::Three aging failing hemodialysis polytetrafluoroethylene bypass shunts, average age 44 months, previously percutaneously revised with balloon angioplasty, presented with pseudoaneurysms and recurrent thrombosis. All were treated with percutaneous covered stent placement within their affected limbs. One graft was ligat...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-003-0013-1

    authors: Silas AM,Bettmann MA

    更新日期:2003-11-01 00:00:00

  • Segment 2/3 Hypertrophy is Greater When Right Portal Vein Embolisation is Extended to Segment 4 in Patients with Colorectal Liver Metastases: A Retrospective Cohort Study.

    abstract:BACKGROUND:In patients with colorectal cancer liver metastases (CRLM), right portal vein embolisation (RPVE) is used to increase the volume of the future remnant liver (FRL) before major hepatic resection. It is not established whether embolisation of segment 4 in addition RPVE (RPVE + 4) induces greater hypertrophy of...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-018-02159-5

    authors: Hammond CJ,Ali S,Haq H,Luo L,Wyatt JI,Toogood GJ,Lodge JPA,Patel JV

    更新日期:2019-04-01 00:00:00

  • Modified PAIR technique for percutaneous treatment of high-risk hydatid cysts.

    abstract:PURPOSE:This paper presents a modification of the known method for percutaneous treatment of hydatid cyst, the PAIR technique. It aimed to achieve safe aspiration of large symptomatic cysts and cysts with a danger of impending rupture. METHODS:We designed a coaxial catheter system to achieve concomitant evacuation of ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/pl00021047

    authors: Gabal AM,Khawaja FI,Mohammad GA

    更新日期:2005-03-01 00:00:00

  • Temporary arterial embolization of liver parenchyma with degradable starch microspheres (EmboCept®S) in a swine model.

    abstract:BACKGROUND:This study aimed to evaluate the embolic properties, time to reperfusion, and histologic changes in temporary embolization of liver tissue with degradable starch microspheres (DSM) in a swine model. METHODS:In four adult minipigs, DSMs were injected into the right or left hepatic artery on the lobar level u...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-014-0966-2

    authors: Pieper CC,Meyer C,Vollmar B,Hauenstein K,Schild HH,Wilhelm KE

    更新日期:2015-04-01 00:00:00

  • Radial artery approach to salvage nonmaturing radiocephalic arteriovenous fistulas.

    abstract:PURPOSE:To evaluate the usefulness of an approach through the radial artery distal to the arteriovenous anastomosis for salvaging nonmaturing radiocephalic arteriovenous fistulas. METHODS:Procedures that fulfilled the following criteria were retrospectively reviewed: (1) autogenous radiocephalic fistulas, (2) fistulas...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-012-0533-7

    authors: Hsieh MY,Lin L,Tsai KC,Wu CC

    更新日期:2013-08-01 00:00:00

  • Bilateral renal artery aneurysm: percutaneous treatment with stent-graft placement.

    abstract::A 51-year-old man with an 8-year history of hypertension (170/115 mmHg with two drugs) and altered renal function (5.6 mg/dl serum creatinine, 101 mg/dl BUN) was referred to our Department to evaluate the renal arteries and rule out renovascular hypertension. Doppler ultrasound and magnetic resonance angiography revea...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-004-8209-6

    authors: Gandini R,Spinelli A,Pampana E,Fabiano S,Pendenza G,Simonetti G

    更新日期:2006-09-01 00:00:00

  • Transnasal Snare Technique for Retrograde Primary Jejunostomy Placement After Surgical Gastrojejunostomy.

    abstract:PURPOSE:To report a transnasal snare technique for retrograde primary jejunostomy placement after surgical gastrojejunostomy. MATERIALS AND METHODS:Two patients underwent the transnasal snare technique for retrograde primary jejunostomy placement. Patients included two females, age 58 and 62. In both patients, a goose...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-017-1777-z

    authors: Srinivasa RN,Chick JFB,Hage AN,Shields JJ,Saad WE,Majdalany BS,Srinivasa RN

    更新日期:2017-12-01 00:00:00

  • Magnetic resonance imaging (MRI) analysis of fibroid location in women achieving pregnancy after uterine artery embolization.

    abstract::The purpose of this study was to evaluate the fibroid morphology in a cohort of women achieving pregnancy following treatment with uterine artery embolization (UAE) for symptomatic uterine fibroids. A retrospective review of magnetic resonance imaging (MRI) of the uterus was performed to assess pre-embolization fibroi...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-007-9118-2

    authors: Walker WJ,Bratby MJ

    更新日期:2007-09-01 00:00:00

  • Percutaneous Lung Tumor Biopsy Under CBCT Guidance with PET-CT Fusion Imaging: Preliminary Experience.

    abstract:PURPOSE:The aim of this study is to evaluate the feasibility of percutaneous lung tumor biopsy under cone beam-computed tomography (CBCT) with PET-CT imaging fusion. MATERIALS AND METHODS:Eleven patients (four women and seven men) underwent C-arm CBCT lung biopsy with PET-CT fusion imaging. A preprocedural PET-CT scan...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-019-02270-1

    authors: Floridi C,Carnevale A,Fumarola EM,Schampaert S,Fontana F,De Palma D,Del Sole A,Giganti M,Carrafiello G

    更新日期:2019-11-01 00:00:00

  • Diaphragmatic hernia after lung percutaneous radiofrequency ablation: incidence and risk factors.

    abstract:PURPOSE:To evaluate diaphragmatic hernias (DH) after percutaneous radiofrequency ablation (PRFA) for basal lung nodules and to detect risk factors. MATERIALS AND METHODS:Between January 2009 and December 2012, the presence of DH was retrospectively recorded in all of the patients who underwent PRFA with multitine expa...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-014-0854-9

    authors: Alberti N,Ferretti G,Buy X,Desjardin M,Al Ammari S,Cazzato RL,Monnin-Bares V,Bechade D,Desolneux G,Michot A,Palussiere J

    更新日期:2014-12-01 00:00:00

  • Transcatheter Arterial Embolization for Gastrointestinal Bleeding Secondary to Gastrointestinal Lymphoma.

    abstract:PURPOSE:To evaluate the effectiveness of transcatheter arterial embolization (TAE) for gastrointestinal (GI) bleeding caused by GI lymphoma. MATERIALS AND METHODS:The medical records of 11 patients who underwent TAE for GI bleeding caused by GI lymphoma between 2001 and 2015 were reviewed retrospectively. RESULTS:A t...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-016-1422-2

    authors: Zheng L,Shin JH,Han K,Tsauo J,Yoon HK,Ko GY,Shin JS,Sung KB

    更新日期:2016-11-01 00:00:00

  • Contralateral loop snare removal of a ruptured and entrapped angioplasty balloon.

    abstract::We describe a technique that extracted a ruptured angioplasty balloon which had become entrapped by a calcified left common iliac artery stenosis. The balloon catheter had been advanced crossover from the right and could not be retracted directly into a sheath across the aortic bifurcation. Therefore, a guidewire was ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02577632

    authors: Braun MA,Smith SJ,Merrill TN

    更新日期:1996-11-01 00:00:00

  • The optimal dose of nicardipine for enhancement of indirect portography.

    abstract:PURPOSE:To determine the optimal dose of nicardipine (NCR) for enhancement of indirect portography. METHODS:Forty-eight patients underwent conventional film indirect portography via the superior mesenteric artery (SMA) first without and then with preinjection of 1/64-2 mg of NCR into the SMA. RESULTS:NCR (1/8-2 mg) s...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1007/s002709900204

    authors: Inoue Y,Nakamura H,Akaji H

    更新日期:1998-01-01 00:00:00

  • Management of ureteral strictures in renal transplants by antegrade balloon dilatation and temporary internal stenting.

    abstract:PURPOSE:To evaluate the efficacy of percutaneous balloon dilatation and temporary internal stenting in the treatment of transplant ureteral strictures. METHODS:Nine patients presenting with obstructed renal transplants were treated by antegrade nephrostomy insertion, ureteroplasty, and temporary internal stenting. Fol...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s002709900412

    authors: Yong AA,Ball ST,Pelling MX,Gedroyc WM,Morgan RA

    更新日期:1999-09-01 00:00:00

  • A migrated aortic stent graft causing erosive spondylopathy.

    abstract::We report about a patient presenting with back pain 4 months after an uneventful endovascular implantation of an aortic stent graft. Computed tomography scan revealed a migration of the stent with consecutive endoleakage, kink formation, and movement of the stent toward the spine, which caused destruction of the aorti...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-013-0695-y

    authors: Gestrich C,Probst C,Wilhelm K,Schiller W

    更新日期:2013-12-01 00:00:00

  • Pulmonary Arteriovenous Malformations Embolized Using a Micro Vascular Plug System: Technical Note on a Preliminary Experience.

    abstract:AIM:To report our preliminary experience using a Micro Vascular Plug (MVP) deployed through a 2.8Fr micro-catheter for the treatment of pulmonary arteriovenous malformations (PAVMs) in a cohort of patients affected by Hereditary Haemorrhagic Telangiectasia (HHT). MATERIALS AND METHODS:Four consecutive female patients ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-016-1493-0

    authors: Boatta E,Jahn C,Canuet M,Garnon J,Ramamurthy N,Cazzato RL,Gangi A

    更新日期:2017-02-01 00:00:00

  • Stenting of the upper gastrointestinal tract: current status.

    abstract::Minimally invasive image-guided insertion of self-expanding metal stents in the upper gastrointestinal tract is the current treatment of choice for palliation of malignant esophageal or gastroduodenal outlet obstructions. A concise review is presented of contemporary stenting practice of the upper gastrointestinal tra...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00270-010-9862-6

    authors: Katsanos K,Sabharwal T,Adam A

    更新日期:2010-08-01 00:00:00