Music perception of cochlear implant users compared with that of hearing aid users.

Abstract:

OBJECTIVES:To investigate the music perception skills of adult cochlear implant (CI) users in comparison with hearing aid (HA) users who have similar levels of hearing impairment. It was hypothesized that the HA users would perform better than the CI recipients on tests involving pitch, instrument, and melody perception, but similarly for rhythm perception. DESIGN:Fifteen users of the Nucleus CI system and 15 HA users participated in a series of music perception tests. All subjects were postlingually deafened adults, with the HA subjects being required to meet the current audiological criteria for CI candidacy. A music test battery was designed for the study incorporating four major tasks: (1) discrimination of 38 pairs of rhythms; (2) pitch ranking of one-octave, half-octave, and quarter-octave intervals; (3) instrument recognition incorporating three subtests, each with 12 different instruments or ensembles; and (4) recognition of 10 familiar melodies. Stimuli were presented via direct audio input at comfortable presentation levels. The test battery was administered to each subject on two separate occasions, approximately 4 mo apart. RESULTS:The results from the rhythm test were 93% correct for the CI group and 94% correct for the HA group; these scores were not significantly different. For the pitch test, there was a significant difference between the HA group and the CI group (p < 0.001), with higher mean scores recorded by the HA group for all three interval sizes. The CI subject group was unable to rank pitches a quarter-octave apart, only scoring at chance level for this interval size. In the instrument recognition test, although there was no significant difference between the mean scores of the two groups, both groups obtained significantly higher scores for the subtest incorporating single instrument stimuli than those incorporating multiple instrumentations (p < 0.001). In the melody test, there was a significant difference between the implantees' mean score of 52% correct and the HA group's mean of 91% (p < 0.001). CONCLUSIONS:As hypothesized, results from the two groups were almost identical for the rhythm test, with the HA group performing significantly better than the CI group on the pitch and melody tests. However, there was no difference between the groups in their ability to identify musical instruments or ensembles. The results of this study indicate that HA users with similar levels of hearing loss perform at least equal to, if not better than, CI users on these music perception tests. However, despite the differences between scores obtained by the CI and HA subject groups, both these subject groups were largely unable to achieve accurate or effective music perception, regardless of the device they used.

journal_name

Ear Hear

journal_title

Ear and hearing

authors

Looi V,McDermott H,McKay C,Hickson L

doi

10.1097/AUD.0b013e31816a0d0b

subject

Has Abstract

pub_date

2008-06-01 00:00:00

pages

421-34

issue

3

eissn

0196-0202

issn

1538-4667

journal_volume

29

pub_type

杂志文章
  • Nonsense syllable test (NST) results and hearing loss.

    abstract::Errors on a nonsense syllable test (NST) were compared to pure-tone thresholds and ages of 109 subjects with normal or sensorineural hearing loss. A strong correlation was found between the number of NST errors and hearing loss at 2000 and 250 Hz. NST errors do not appear to be related to the age of subjects. Excellen...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198702000-00008

    authors: Butts FM,Ruth RR,Schoeny ZG

    更新日期:1987-02-01 00:00:00

  • Measurement of individual loudness functions by trisection of loudness ranges.

    abstract:OBJECTIVES:Loudness-balance measurements with monaurally impaired subjects have shown that the shape of the loudness versus sound-pressure curve among hearing-impaired persons varies significantly. But the effectiveness of adjusting the compression characteristics of wide-dynamic-range compression hearing aids-the comp...

    journal_title:Ear and hearing

    pub_type: 临床试验,杂志文章

    doi:10.1097/AUD.0b013e318177d9c6

    authors: Villchur E,Killion MC

    更新日期:2008-10-01 00:00:00

  • Using multichannel wide-dynamic range compression in severely hearing-impaired listeners: effects on speech recognition and quality.

    abstract:OBJECTIVE:The objective of this study was to compare speech recognition across a sampling of amplification choices available for listeners with severe loss. This includes conventional options (linear with peak clipping and linear with compression limiting) and newer strategies (multichannel wide-dynamic range compressi...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200504000-00002

    authors: Souza PE,Jenstad LM,Folino R

    更新日期:2005-04-01 00:00:00

  • Hearing function in patients living with HIV/AIDS.

    abstract:OBJECTIVES:During the earlier years of the HIV/AIDS epidemic, initial reports described sensorineural hearing loss in up to 49% of individuals with HIV/AIDS. During those years, patients commonly progressed to advanced stages of HIV disease and frequently had neurological complications. However, the abnormalities on pu...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000064

    authors: Luque AE,Orlando MS,Leong UC,Allen PD,Guido JJ,Yang H,Wu H

    更新日期:2014-11-01 00:00:00

  • The influence of contextual information on the perception of speech by postlingually and prelingually profoundly hearing-impaired Hebrew-speaking adolescents and adults.

    abstract:OBJECTIVE:To study linguistic context effects on speech perception by prelingually (N = 10) and postlingually (N = 10) hearing-impaired Hebrew-speaking adolescents and adults. DESIGN:Participants were cochlear implant surgery candidates with profound sensorineural hearing loss (95 dB HL+). Four levels of speech percep...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200106000-00008

    authors: Most T,Adi-Bensaid L

    更新日期:2001-06-01 00:00:00

  • Analog and zero phase-shift digital filtering of the auditory brain stem response waveform.

    abstract::Auditory brain stem response waveforms, derived from normal ears, were analyzed with a computer-based digital filtering program as a means of systematically evaluating the effects of phase-shift distortion. Off-line analysis involved the stimulated responses of a Butterworth-type filter at five high-pass and four low-...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198612000-00006

    authors: Domico WD,Kavanagh KT

    更新日期:1986-12-01 00:00:00

  • The efficiency of the single- versus multiple-stimulus auditory steady state responses in infants.

    abstract:OBJECTIVES:Multiple auditory steady state responses (ASSRs) will likely be included in the diagnostic test battery for estimating infant auditory thresholds in the near future; however, the effects of single- versus multiple-stimulus presentation in infants has never been investigated. In adults, there are no interacti...

    journal_title:Ear and hearing

    pub_type: 临床试验,杂志文章

    doi:10.1097/AUD.0b013e3181ff352c

    authors: Hatton J,Stapells DR

    更新日期:2011-05-01 00:00:00

  • Evaluation of streamlined programming procedures for the Nucleus cochlear implant with the Contour electrode array.

    abstract:OBJECTIVE:The objective of this study was to evaluate streamlined programming procedures for the Nucleus cochlear implant system with the Contour electrode array. DESIGN:Phase 1 involved an examination of the clinical MAPs for the first 103 recipients implanted with the Contour electrode array in the Melbourne Cochlea...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/01.aud.0000188201.86799.01

    authors: Plant K,Law MA,Whitford L,Knight M,Tari S,Leigh J,Pedley K,Nel E

    更新日期:2005-12-01 00:00:00

  • Evaluation of Long-Term Cochlear Implant Use in Subjects With Acquired Unilateral Profound Hearing Loss: Focus on Binaural Auditory Outcomes.

    abstract:INTRODUCTION:Cochlear implantation (CI) in subjects with unilateral profound sensorineural hearing loss was investigated. The authors of the present study demonstrated the binaural auditory outcomes in a 12- and 36-month prospective cohort outcome study. The present study aimed to do a long-term (LT) evaluation of the ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000359

    authors: Mertens G,De Bodt M,Van de Heyning P

    更新日期:2017-01-01 00:00:00

  • Time course and cost of misdirecting auditory spatial attention in younger and older adults.

    abstract:OBJECTIVES:The effects of directing, switching, and misdirecting auditory spatial attention in a complex listening situation were investigated in 8 younger and 8 older listeners with normal-hearing sensitivity below 4 kHz. DESIGN:In two companion experiments, a target sentence was presented from one spatial location a...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e31829bf6ec

    authors: Singh G,Pichora-Fuller MK,Schneider BA

    更新日期:2013-11-01 00:00:00

  • Are You There for Me? Joint Engagement and Emotional Availability in Parent-Child Interactions for Toddlers With Moderate Hearing Loss.

    abstract:OBJECTIVES:This study examined joint engagement and emotional availability of parent-child interactions for toddlers with moderate hearing loss (MHL) compared with toddlers with normal hearing (NH) and in relation to children's language abilities. DESIGN:The participants in this study were 25 children with MHL (40 to ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000596

    authors: Dirks E,Rieffe C

    更新日期:2019-01-01 00:00:00

  • Hearing in time: evoked potential studies of temporal processing.

    abstract::This article reviews the temporal aspects of human hearing as measured using the auditory evoked potentials. Interaural timing cues are essential to the detection and localization of sound sources. The temporal envelope of a sound--how it changes in amplitude over time--is crucially important for speech perception. Ti...

    journal_title:Ear and hearing

    pub_type: 杂志文章,评审

    doi:10.1097/AUD.0b013e31827ada02

    authors: Picton T

    更新日期:2013-07-01 00:00:00

  • Prevalence of Hearing Loss Among a Representative Sample of Canadian Children and Adolescents, 3 to 19 Years of Age.

    abstract:OBJECTIVES:There are no nationally representative hearing loss (HL) prevalence data available for Canadian youth using direct measurements. The present study objectives were to estimate national prevalence of HL using audiometric pure-tone thresholds (0.5 to 8 kHz) and or distortion product otoacoustic emissions (DPOAE...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000345

    authors: Feder KP,Michaud D,McNamee J,Fitzpatrick E,Ramage-Morin P,Beauregard Y

    更新日期:2017-01-01 00:00:00

  • Effects of reference interaural time and intensity differences on binaural performance in listeners with normal and impaired hearing.

    abstract:OBJECTIVE:The purpose of this research was to measure the effects of reference interaural time and intensity differences on binaural performance in listeners with normal hearing and impaired hearing for a number of different binaural tests. Experiment 1 measures the dependence of binaural detection and discrimination p...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199508000-00001

    authors: Koehnke J,Culotta CP,Hawley ML,Colburn HS

    更新日期:1995-08-01 00:00:00

  • Behavioral Measures of Listening Effort in School-Age Children: Examining the Effects of Signal-to-Noise Ratio, Hearing Loss, and Amplification.

    abstract:OBJECTIVES:Increased listening effort in school-age children with hearing loss (CHL) could compromise learning and academic achievement. Identifying a sensitive behavioral measure of listening effort for this group could have both clinical and research value. This study examined the effects of signal-to-noise ratio (SN...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000623

    authors: McGarrigle R,Gustafson SJ,Hornsby BWY,Bess FH

    更新日期:2019-03-01 00:00:00

  • SSW test performance-intensity functions for hearing-impaired adults.

    abstract::The present study investigated the effects of intensity on hearing-impaired adults' performance on the Staggered Spondaic Word (SSW) test. Fifteen adults having mild-to-moderate cochlear hearing losses were administered the 40-item SSW test which was subdivided into four groups of ten items each, and presented at diff...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198411000-00004

    authors: Flynn PA,Danhauer JL,Gerber SE,Goller MC,Arnst DJ

    更新日期:1984-11-01 00:00:00

  • Determining the upper limits of stimulation for auditory steady-state response measurements.

    abstract:OBJECTIVE:To determine the maximum stimulus levels at which a measured auditory steady-state response (ASSR) can be assumed to be a reliable measure of auditory thresholds. DESIGN:ASSR thresholds were measured at octave frequencies from 500 to 4000 Hz in 10 subjects with profound hearing loss. These subjects provided ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/01.aud.0000130801.96611.6b

    authors: Gorga MP,Neely ST,Hoover BM,Dierking DM,Beauchaine KL,Manning C

    更新日期:2004-06-01 00:00:00

  • Evaluation of a tinnitus masking program: a follow-up study of 598 patients.

    abstract::A follow-up study of two groups of tinnitus patients was conducted in an attempt to evaluate the tinnitus masking program. Results are discussed separately for a group of patients seen during the first three years of the program (1976 through 1978) and during the last year (1979). These results suggest an improvement ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198003000-00004

    authors: Schleuning AJ,Johnson RM,Vernon JA

    更新日期:1980-03-01 00:00:00

  • Chronic Conductive Hearing Loss Is Associated With Speech Intelligibility Deficits in Patients With Normal Bone Conduction Thresholds.

    abstract:OBJECTIVES:The main objective of this study is to determine whether chronic sound deprivation leads to poorer speech discrimination in humans. DESIGN:We reviewed the audiologic profile of 240 patients presenting normal and symmetrical bone conduction thresholds bilaterally, associated with either an acute or chronic u...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000787

    authors: Okada M,Welling DB,Liberman MC,Maison SF

    更新日期:2020-05-01 00:00:00

  • Mechanisms of Localization and Speech Perception with Colocated and Spatially Separated Noise and Speech Maskers Under Single-Sided Deafness with a Cochlear Implant.

    abstract:OBJECTIVES:This study tested listeners with a cochlear implant (CI) in one ear and acoustic hearing in the other ear, to assess their ability to localize sound and to understand speech in collocated or spatially separated noise or speech maskers. DESIGN:Eight CI listeners with contralateral acoustic hearing ranging fr...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000708

    authors: Dirks C,Nelson PB,Sladen DP,Oxenham AJ

    更新日期:2019-11-01 00:00:00

  • Behavioral Pure-Tone Threshold Shifts Caused by Tympanic Membrane Electrodes.

    abstract:OBJECTIVE:To determine whether tympanic membrane (TM) electrodes induce behavioral pure-tone threshold shifts. DESIGN:Pure-tone thresholds (250 to 8000 Hz) were measured twice in test (n = 18) and control (n = 10) groups. TM electrodes were placed between first and second threshold measurements in the test group, wher...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000275

    authors: Smith SB,Lichtenhan J,Cone B

    更新日期:2016-07-01 00:00:00

  • Assessment of ear disorders using power reflectance.

    abstract::This article describes the effect of various pathologies on power reflectance (PR) and absorbance measured in human adults. The pathologies studied include those affecting the tympanic membrane, the middle-ear ossicles, the middle-ear cavity, the inner ear, and intracranial pressure. Interesting pathology-induced chan...

    journal_title:Ear and hearing

    pub_type: 杂志文章,评审

    doi:10.1097/AUD.0b013e31829c964d

    authors: Nakajima HH,Rosowski JJ,Shahnaz N,Voss SE

    更新日期:2013-07-01 00:00:00

  • Children's recognition of spectrally degraded cartoon voices.

    abstract:OBJECTIVES:Although the spectrally degraded input provided by cochlear implants (CIs) is sufficient for speech perception in quiet, it poses problems for talker identification. The present study examined the ability of normally hearing (NH) children and child CI users to recognize cartoon voices while listening to spec...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e3182a468d0

    authors: van Heugten M,Volkova A,Trehub SE,Schellenberg EG

    更新日期:2014-01-01 00:00:00

  • Single-channel versus bilateral multichannel cochlear implant results: a case report.

    abstract::Pre- and postoperative audiologic findings are compared in a patient who underwent three cochlear implant surgeries: an initial single-channel device in a recently deafened ear with no residual hearing, followed by a multichannel device in a congenitally deafened ear with a severe to profound loss, and subsequent expl...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199112000-00007

    authors: Pijl S

    更新日期:1991-12-01 00:00:00

  • Identification, assessment, and management of children with unilateral sensorineural hearing loss.

    abstract::Because some unilaterally hearing-impaired children appear to experience difficulty in communication and educational progress, it seems only appropriate to reassess the identification and management strategies that are used with these children. Accordingly, this paper presents some general information on identificatio...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198602000-00008

    authors: Bess FH,Klee T,Culbertson JL

    更新日期:1986-02-01 00:00:00

  • The relationship between audiometric and self-report measures of hearing handicap.

    abstract::In 430 individuals with adult onset hearing loss, relationships were explored between definitions of handicap based on a number of arithmetic formulas applied to audiometric data and definitions of handicap based on two self-report questionnaires (the Denver Scale of Communication Function and the Social Hearing Handi...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198503000-00005

    authors: Brainerd SH,Frankel BG

    更新日期:1985-03-01 00:00:00

  • Neurophysiological Differences in Emotional Processing by Cochlear Implant Users, Extending Beyond the Realm of Speech.

    abstract:OBJECTIVE:Cochlear implants (CIs) restore a sense of hearing in deaf individuals. However, they do not transmit the acoustic signal with sufficient fidelity, leading to difficulties in recognizing emotions in voice and in music. The study aimed to explore the neurophysiological bases of these limitations. DESIGN:Twent...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000701

    authors: Deroche MLD,Felezeu M,Paquette S,Zeitouni A,Lehmann A

    更新日期:2019-09-01 00:00:00

  • Auditory development reflected by middle latency response.

    abstract::The auditory middle latency response (MLR) seems to have a relatively long developmental time course, extending through the first decade of life. Characteristics of each MLR component change developmentally not only with respect to waveform morphology but also with respect to response reliability, dependence on awaren...

    journal_title:Ear and hearing

    pub_type: 杂志文章,评审

    doi:10.1097/00003446-199610000-00008

    authors: McGee T,Kraus N

    更新日期:1996-10-01 00:00:00

  • Effect of minimal/mild hearing loss on children's speech understanding in a simulated classroom.

    abstract:OBJECTIVES:While classroom acoustics can affect educational performance for all students, the impact for children with minimal/mild hearing loss (MMHL) may be greater than for children with normal hearing (NH). The purpose of this study was to examine the effect of MMHL on children's speech recognition comprehension an...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000092

    authors: Lewis DE,Valente DL,Spalding JL

    更新日期:2015-01-01 00:00:00

  • Longitudinal changes in word recognition by patients who use the Ineraid cochlear implant.

    abstract::The time course for reacquisition of spondee word recognition was examined for 27 patients who use the Ineraid cochlear implant. At 1 month postfitting, test scores ranged from 0 to 84% correct. The median score was 10% correct. At 22 to 28 months postfitting, the scores ranged from 0 to 100% correct. The median score...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199012000-00008

    authors: Dorman MF,Dankowski K,McCandless G,Parkin JL,Smith L

    更新日期:1990-12-01 00:00:00