Abstract:
PURPOSE:To observe changes in intraocular pressure (IOP), the manner in which the eye is suctioned, and the effect of the number of suction ports. SETTING:Department of Ophthalmology, Tokyo Dental College, Suidobashi Hospital, Tokyo, Japan. METHODS:Suction rings with single or dual ports were made of transparent acrylic acid resin to facilitate observation with a digital video camera. The IOP and the duration of the IOP increase (time to reach 90% of the maximum IOP) were measured in 6 porcine eyes with an intra-vein pressure-sensor catheter in the vitreous cavity. The IOP changes were recorded using a personal computer. RESULTS:Suctioning with single- and dual-port suction rings was similar. The IOP increases with single- and dual-port suction rings were similar (99.1 mm Hg +/- 6.1 [SD] and 99.0 +/- 6.5 mm Hg, respectively) (P=.987). The duration of the IOP increase was also similar (4.21 +/- 0.24 seconds and 4.12 +/- 0.33 seconds, respectively) (P=.190). CONCLUSIONS:The number of ports did not affect suctioning and changes in IOP. This technique is useful in developing the ideal shape and setting of the suction ring.
journal_name
J Cataract Refract Surgjournal_title
Journal of cataract and refractive surgeryauthors
Bissen-Miyajima H,Suzuki S,Ohashi Y,Minami Kdoi
10.1016/j.jcrs.2004.06.085subject
Has Abstractpub_date
2005-03-01 00:00:00pages
590-4issue
3eissn
0886-3350issn
1873-4502pii
S0886-3350(04)00883-1journal_volume
31pub_type
杂志文章abstract:PURPOSE:To compare the incidence of diffuse lamellar keratitis (DLK) after laser in situ keratomileusis (LASIK) with flap creation using the 15 kHz (FS15), 30 kHz (FS30), or 60 kHz (FS60) femtosecond laser. SETTING:University-based academic practice, Ann Arbor, Michigan, USA. DESIGN:Retrospective comparative case ser...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2010.09.003
更新日期:2010-11-01 00:00:00
abstract:PURPOSE:To compare the outgrowth of lens epithelial cells (LECs) on 3 types of intraocular lenses (IOLs) to determine the influence of lens material and lens design (optic edge) on this phenomenon. SETTING:Department of Ophthalmology, University of Vienna, Medical School, Vienna, Austria. METHOD:Ninety eyes scheduled...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(00)00861-0
更新日期:2001-06-01 00:00:00
abstract:PURPOSE:To compare the pharmacotherapeutic practices of high-volume photorefractive keratectomy (PRK) surgeons with suggested practices gleaned from the current literature. SETTING:York Finch Eye Associates, Toronto, Canada. METHODS:Seventy-five ophthalmic surgeons believed by the authors to do a high-volume of PRKs ...
journal_title:Journal of cataract and refractive surgery
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1016/s0886-3350(96)80116-7
更新日期:1996-10-01 00:00:00
abstract:PURPOSE:To perform a pilot study of a new in-the-bag Fresnel prism intraocular lens (IOL) designed to deviate the image from diseased to healthy retina in eyes with bilateral age-related macular degeneration (AMD). SETTING:Anterior segment subspeciality practice, Pretoria, South Africa. DESIGN:Prospective nonmasked t...
journal_title:Journal of cataract and refractive surgery
pub_type: 临床试验,杂志文章
doi:10.1016/j.jcrs.2013.10.049
更新日期:2014-07-01 00:00:00
abstract::Capsular bag distension syndrome (CBDS) is a rare complication of cataract surgery due to collection of fluid behind the intraocular lens (IOL). Nd:Yag laser capsulotomy is commonly performed to release the fluid collection; however, the potential risk of infection and inflammation has led to adaptation of numerous su...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1097/j.jcrs.0000000000000362
更新日期:2020-12-01 00:00:00
abstract:PURPOSE:To evaluate the effect of removal and/or exchange of intrastromal corneal ring segments (ICRS, Intacs); specifically the risk factors, degree of reversibility, and visual outcomes. SETTING:Gimbel Eye Centres, Calgary, Edmonton, and Vancouver, Canada. METHODS:Prospective cohort data were collected on 71 eyes t...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(01)01172-5
更新日期:2002-04-01 00:00:00
abstract:PURPOSE:To investigate the accuracy and predictability of intraocular lens (IOL) power calculation in postoperative photorefractive keratectomy (PRK) eyes. SETTING:Gimbel Eye Centre, Calgary, Alberta, Canada. METHODS:The results in 5 cataract surgery eyes that had had PRK were analyzed retrospectively. Target refract...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(00)00480-6
更新日期:2000-08-01 00:00:00
abstract:PURPOSE:To compare the intraoperative behavior and postoperative outcomes of posterior capsule dehiscence during phacoemulsification and during manual extracapsular cataract extraction (ECCE). SETTING:L.V. Prasad Eye Institute, Hyderabad, India. METHODS:This study was a retrospective chart review of consecutive cases...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(02)01696-6
更新日期:2003-03-01 00:00:00
abstract:PURPOSE:To compare the development of posterior capsule opacification (PCO) and neodymium:YAG (Nd:YAG) capsulotomy rates between 2 microincision intraocular lenses (IOLs) 4 years after surgery. SETTING:Department of Ophthalmology, Medical University of Vienna, Vienna, Austria. DESIGN:Prospective randomized clinical t...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章,随机对照试验
doi:10.1016/j.jcrs.2014.09.037
更新日期:2015-05-01 00:00:00
abstract::A 25-year-old woman with myopia who had an AC pIOL implantation in the left eye and posterior chamber pIOL implantation in the right eye developed bilateral granulomatous panuveitis 2 months after the second surgery. Physical examination showed bilateral Koeppe and Busacca nodules. Fluorescein angiography showed diffu...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2012.02.026
更新日期:2012-06-01 00:00:00
abstract::We used power modulations in addition to new technology available from 6 phacoemulsification manufacturers and altered our phacoemulsification techniques to take advantage of these technologies to significantly reduce the amount of ultrasound energy placed into the eye and enhance the rapidity and level of visual reha...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(00)00834-8
更新日期:2001-02-01 00:00:00
abstract:UNLABELLED:We describe a case of unilateral corneal ectasia in a 26-year-old man following small-incision lenticule extraction. The preoperative corneal topography was normal, with a minimum corneal thickness of 511 μm and 513 μm in the right eye and left eye, respectively. Lenticules of 85 μm and 82 μm were fashioned ...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2015.08.006
更新日期:2015-09-01 00:00:00
abstract:PURPOSE:To investigate whether topical diclofenac sodium 0.1% solution (Voltaren Ophthalmic) is as efficacious as topical ketorolac tromethamine 0.5% solution (Acular) in the treatment of established, chronic cystoid macular edema (CME) after uneventful phacoemulsification cataract extraction with posterior chamber int...
journal_title:Journal of cataract and refractive surgery
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1016/s0886-3350(03)00233-5
更新日期:2003-12-01 00:00:00
abstract:PURPOSE:To determine predictors of long-term intraocular pressure (IOP) after cataract surgery. SETTING:Hunter Holmes McGuire Veterans Administration Hospital, Richmond, Virginia, USA. DESIGN:Case series. METHODS:Clinical variables, IOP by applanation tonometry, anatomic features on anterior segment optical coherenc...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2011.07.033
更新日期:2012-01-01 00:00:00
abstract::Spontaneous bilateral lens dislocation with subcapsular and cortical cataract was found in a 17-year-old boy with Seckel syndrome. No other identifiable cause of lens dislocation was noted. ...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2006.12.027
更新日期:2007-05-01 00:00:00
abstract:UNLABELLED:We describe a technique that uses flexible iris hooks to dilate and stabilize the capsular bag in a patient with a very deep set and small eye, narrow palpebral fissure, shallow anterior chamber, and very small pupil, who was scheduled for routine phacoemulsification for a white cataract. At the time of iris...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2014.07.009
更新日期:2014-09-01 00:00:00
abstract:PURPOSE:To report the prevalence of ocular surface dysfunction in patients presenting for cataract surgery evaluation. SETTING:Duke University Eye Center and Weill Cornell Ophthalmology, single-physician practices. DESIGN:Prospective case series. METHODS:Consecutive patients presenting for cataract surgery evaluatio...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2018.06.026
更新日期:2018-09-01 00:00:00
abstract:PURPOSE:To determine whether the yellow filters often used for glare reduction influence retinal straylight measured in healthy eyes. SETTING:Department of Ophthalmology, Antwerp University Hospital, Edegem, Belgium. DESIGN:Prospective case series. METHODS:For each eye, the spherical equivalent (SE) was determined u...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2017.06.033
更新日期:2017-08-01 00:00:00
abstract:PURPOSE:To evaluate transient increases in intraocular pressure (IOP) after use of high-viscosity viscoelastic agents in cataract surgery. SETTING:Military Hospital, Ulm, Germany. METHODS:In a prospective, randomized study, we evaluated IOP following cataract surgery using two different viscoelastic substances (Healo...
journal_title:Journal of cataract and refractive surgery
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1016/s0886-3350(96)80224-0
更新日期:1996-03-01 00:00:00
abstract:PURPOSE:To use the double-pass technique to evaluate the in vitro optical quality of foldable monofocal intraocular lenses (IOLs) used to correct aphakia. SETTING:Universitat Politècnica de Catalunya, Terrassa, and Instituto de Microcirugía Ocular de Barcelona, Barcelona, Spain; Universidad Nacional de Tucumán, Tucumá...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2009.03.022
更新日期:2009-08-01 00:00:00
abstract:PURPOSE:To compare the volumetric occlusion break surge responses of phacoemulsification units from 1 company over 3 generations under varying vacuum limits and target intraocular pressure (IOP) settings. SETTING:Alcon Research, Ltd., Lake Forest, California, USA. DESIGN:Experimental study. METHODS:Three generations...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2018.01.032
更新日期:2018-12-01 00:00:00
abstract:PURPOSE:To evaluate a poly(methyl methacrylate) refractive, zonal-progressive multifocal intraocular lens (IOL) in patients requiring cataract surgery. SETTING:Department of Ophthalmology, Saiseikai Kurihashi Hospital, Saitama, Japan. METHODS:This open-label noncomparative study evaluated 58 eyes of 31 Japanese patie...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(99)00408-3
更新日期:2000-07-01 00:00:00
abstract::A patient with long-standing ankylosing spondylitis and chronic uveitis needed cataract extraction in his only eye. Extensive spinal deformities, including cervical kyphosis, prevented him from being positioned satisfactorily for surgery using a routine head-end or temporal position for the surgeon. The best possible ...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(00)00596-4
更新日期:2000-08-01 00:00:00
abstract:PURPOSE:To evaluate irregularity of the anterior and posterior cornea before and after Descemet-stripping endothelial keratoplasty (DSEK) and its effect on visual acuity. SETTING:Department of Ophthalmology, Keio University School of Medicine, Tokyo, Japan. METHODS:Corneal data were acquired using a rotating Scheimpf...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2008.11.062
更新日期:2009-04-01 00:00:00
abstract::We report 3 cases of globe rupture after peribulbar anesthesia. We discuss the predisposing factors, presenting features, and visual outcome after this complication. Globe explosion is a severe complication of inadvertent intraocular injection during peribulbar anesthesia. Visual outcome after vitrectomy is generally ...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(01)01034-3
更新日期:2002-03-01 00:00:00
abstract:PURPOSE:To assess the visual results after bilateral implantation of the bifocal Acri.LISA 366D intraocular lens (IOL) (Acri.Tec AG). SETTING:Fernández-Vega Ophthalmological Institute, Oviedo, Spain. METHODS:Eighty-one patients had bilateral implantation of the distance-dominant bifocal Acri.LISA 366D IOL in a prospe...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2007.06.067
更新日期:2007-11-01 00:00:00
abstract:PURPOSE:To assess the feasibility of determining intraocular lens (IOL) power by measurement of the central optic thickness using clinically available Scheimpflug imaging (Pentacam, Oculus). SETTING:King's College Hospital Ophthalmology Department, London, United Kingdom. METHODS:Sixty-seven eyes were assessed 1 mont...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2007.02.023
更新日期:2007-06-01 00:00:00
abstract:PURPOSE:To calculate theoretically the magnitude of the excess area between the lower surface of the flap and the underlying ablated stroma. METHODS:On the initial assumptions of a nonextensible flap and a spherical cornea, flap and ablated stromal areas were determined as a function of myopic correction in the range ...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/s0886-3350(02)01636-x
更新日期:2002-12-01 00:00:00
abstract::We present a simple, effective technique to remove an intraocular lens (IOL) via a very small incision (2.2 mm). After the IOL is carefully removed from the capsular bag, into the anterior chamber, 2 radial incisions, 35 degrees to 50 degrees apart, are made with a Vannas scissors. This results in 2 IOL pieces (maximu...
journal_title:Journal of cataract and refractive surgery
pub_type: 杂志文章
doi:10.1016/j.jcrs.2009.02.036
更新日期:2009-07-01 00:00:00
abstract:PURPOSE:To evaluate the clinical feasibility of the prototype version of a commercial partial coherence interferometry instrument (axial length measurement, ALM, Carl Zeiss Jena) for noninvasive, high-precision biometry in cataractous eyes. SETTING:Department of Ophthalmology, Vienna General Hospital, and Institute of...
journal_title:Journal of cataract and refractive surgery
pub_type: 临床试验,杂志文章
doi:10.1016/s0886-3350(01)01272-x
更新日期:2002-02-01 00:00:00