Body surface mapping of atrial arrhythmias: atlas of paced P wave integral maps to localize the focal origin of right atrial tachycardia.

Abstract:

:Successful curative treatment of right atrial tachycardia (AT) can be obtained provided detailed catheter activation mapping of the target site for radiofrequency energy application has been accomplished. However, right AT mapping may be difficult with a single roving catheter due to infrequent presence or noninducibility of the arrhythmia. The present report describes the preliminary clinical use of body surface mapping as an adjunctive noninvasive method to identify the region of AT origin prior to catheter ablation. This technique has been previously applied to develop a reference data base of 17 different paced P wave integral map patterns. The data base was designed by performing right atrial pace mapping in patients without structural heart disease. Each P wave integral map pattern in the data base is unique to ectopic activation onset in a circumscribed right atrial endocardial segment. Localization of the segment of AT origin is accomplished by matching the P wave integral map of a single AT beat with the data base of paced P wave integral maps. The use of body surface mapping as an integral part of the mapping protocol during radiofrequency catheter ablation of right AT offers the possibility to: (1) noninvasively determine the arrhythmogenic target area for ablation using a single beat analysis approach; (2) confine detailed catheter activation mapping to a limited area; and (3) accelerate the overall procedure and limit fluoroscopic exposure by reducing the time required for mapping.

journal_name

J Electrocardiol

authors

SippensGroenewegen A,Roithinger FX,Peeters HA,Linnenbank AC,van Hemel NM,Steiner PR,Lesh MD

doi

10.1016/s0022-0736(98)90298-9

subject

Has Abstract

pub_date

1998-01-01 00:00:00

pages

85-91

eissn

0022-0736

issn

1532-8430

journal_volume

31 Suppl

pub_type

杂志文章
  • Computer analysis of the spatial angular parameters of the canine QRSsE loop from necropsy-verified normal dogs.

    abstract::Vectorcardiograms were recorded by the canine modification of the axial lead system of McFee and Parungao from 38 necropsy-verified normal dogs placed in the recommended position of right lateral recumbency. A digital computer program was used to identify and analyze the spatial characteristics of the QRSsE loop. In o...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/s0022-0736(83)80004-1

    authors: Musselman EE

    更新日期:1983-07-01 00:00:00

  • Electrocardiographic estimation of successful ablation site in patients with manifest inferior paraseptal accessory pathway.

    abstract::Inferior paraseptal accessory pathways (APs) have a wide distribution and prediction of AP location before radiofrequency ablation is very important in such pathways. We aimed to estimate successful ablation site based on electrocardiogram in 137 patients (mean age: 25.8±9.0; 126 males) with single manifest inferior p...

    journal_title:Journal of electrocardiology

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jelectrocard.2015.12.017

    authors: Kabul HK,Ulus T,Barcın C,Unlu M,Samedli S,Kose S

    更新日期:2016-03-01 00:00:00

  • T loop in posterior myocardial infarction: a useful clue to vectorcardiographic diagnosis.

    abstract::In order to differentiate posterior (posterolateral) myocardial infarction (PMI) from the anterior shift of the QRS loop in "normal variant" cases using a vectorcardiogram, the T loop as well as the QRS loop in the transverse plane (TP) were analyzed in 34 elderly Japanese males with angiographically-proven PMI and in...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/s0022-0736(86)80017-6

    authors: Takatsu F,Osugi J,Nagaya T,Uwatoko M,Watabe S,Ishikawa H

    更新日期:1986-04-01 00:00:00

  • Quantitative vectorcardiographic criteria for the differentiation between atrial septal defects of primum and secundum types.

    abstract::From a population of 304 patients who were operated on for atrial septal defects, 25 patients with primum defects and 78 patients with secundum defects were studied with regard to the ability of various quantitative axial lead vectorcardiographic (VCG) data to predict the anatomical type of defect. The patients includ...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/s0022-0736(75)80023-9

    authors: Rasmussen K

    更新日期:1975-01-01 00:00:00

  • Correlation of ST-segment "hump sign" during exercise testing with impaired diastolic function of the left ventricle.

    abstract:BACKGROUND:The appearance of a discrete upward deflection of the ST segment, termed the ST hump sign during exercise testing has been associated with resting hypertension and exaggerated blood pressure response to exercise. OBJECTIVE:We investigated the correlation between the presence of hump sign during exercise tes...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/j.jelectrocard.2009.09.001

    authors: Michaelides AP,Raftopoulos LG,Aggeli C,Liakos C,Antoniades C,Fourlas C,Stamatopoulos E,Ioakeimides N,Soulis D,Stefanadis C

    更新日期:2010-03-01 00:00:00

  • Fractal mechanisms and heart rate dynamics. Long-range correlations and their breakdown with disease.

    abstract::Under healthy conditions, the normal cardiac (sinus) interbeat interval fluctuates in a complex manner. Quantitative analysis using techniques adapted from statistical physics reveals the presence of long-range power-law correlations extending over thousands of heartbeats. This scale-invariant (fractal) behavior sugge...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/s0022-0736(95)80017-4

    authors: Peng CK,Havlin S,Hausdorff JM,Mietus JE,Stanley HE,Goldberger AL

    更新日期:1995-01-01 00:00:00

  • Remodeling of cardiac gap junctions: the relationship to the genesis of ventricular tachycardia.

    abstract::Cardiac gap junctions are responsible for normal conduction properties of the ventricles. Alteration in gap junction distribution (remodeling) in ischemic heart disease is likely to be an important cause of life threatening ventricular arrhythmias. ...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1054/jelc.2001.28834

    authors: Wit AL

    更新日期:2001-01-01 00:00:00

  • Triggered rhythms in atrial muscle.

    abstract::Intracellular and extracellular recording techniques were used to study triggered activity in tissues isolated from the inferior right atrium of the dog. In the presence of norepinephrine (greater than 10(-7) M) single stimuli or short rapid pacing elicited action potentials with delayed after-depolarizations, leading...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/0022-0736(87)90005-7

    authors: Lipsius SL

    更新日期:1987-01-01 00:00:00

  • Noninvasive blood potassium measurement using signal-processed, single-lead ecg acquired from a handheld smartphone.

    abstract:OBJECTIVE:We have previously used a 12-lead, signal-processed ECG to calculate blood potassium levels. We now assess the feasibility of doing so with a smartphone-enabled single lead, to permit remote monitoring. PATIENTS AND METHODS:Twenty-one hemodialysis patients held a smartphone equipped with inexpensive FDA-appr...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/j.jelectrocard.2017.06.008

    authors: Yasin OZ,Attia Z,Dillon JJ,DeSimone CV,Sapir Y,Dugan J,Somers VK,Ackerman MJ,Asirvatham SJ,Scott CG,Bennet KE,Ladewig DJ,Sadot D,Geva AB,Friedman PA

    更新日期:2017-01-01 00:00:00

  • Intravenous electrocardiographic guidance for placement of peripherally inserted central catheters.

    abstract:BACKGROUND:Correct positioning of peripherally inserted central catheters (PICCs) is essential to avoid complications. We evaluated intravenous electrocardiogram (ECG) recordings during PICC placement to assess the effectiveness of this guidance technique to reduce complications resulting from incorrect catheter placem...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/j.jelectrocard.2010.02.003

    authors: Smith B,Neuharth RM,Hendrix MA,McDonnall D,Michaels AD

    更新日期:2010-05-01 00:00:00

  • Characteristic findings on the standard 12-lead ECG in patients with the fasciculoventricular Mahaim fiber.

    abstract::Standard 12-lead electrocardiograms with a Q wave in lead V1 were obtained from 32 subjects without organic cardiac disease and analyzed for features that might characterize an abnormal atrioventricular conduction through the fasciculoventricular Mahaim fiber. Following an infusion of ajmaline, the Q wave in V1 vanish...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/0022-0736(92)90030-4

    authors: Miyaguchi K,Tsuzuki J,Yokota M,Hayashi H

    更新日期:1992-10-01 00:00:00

  • Brugada-type patterns are easily observed in high precordial lead ECGs in collegiate athletes.

    abstract:BACKGROUND:Displacement of ECG leads can result in unwarranted findings. We assessed the frequency of Brugada-type patterns in athletes when precordial leads were purposely placed upward. METHODS:Four hundred ninety-one collegiate athletes underwent two ECGs: one with standard leads, one with V1 and V2 along the 2nd i...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/j.jelectrocard.2013.08.014

    authors: Chung EH,McNeely DE 3rd,Gehi AK,Brickner T,Evans S,Pryski E,Waicus K,Stafford H,Mounsey JP,Schwartz JD,Huang S,Pursell I,Ciocca M

    更新日期:2014-01-01 00:00:00

  • High-resolution ECG on a standard ECG cart.

    abstract::High-resolution (HI-RES) ECG analysis software and a new front end have been designed for a standard 12-lead ECG cart, MAC-12. The front end acquires orthogonal ECG at 1,000 samples/sec and 1.2 microV/bit and transmits to the cart. The HI-RES software delineates QRS complexes and correlates them with a template in fre...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/0022-0736(88)90062-3

    authors: Reddy BR,Christenson DW,Rowlandson GI

    更新日期:1988-01-01 00:00:00

  • Normal limits of the electrocardiogram in Indians.

    abstract:AIMS:The objective of the study was to develop normal limits of the ECG in an apparently healthy population of South Asians living in India. METHODS:Three centres contributed to recording 12 lead ECGs on identical digital electrocardiographs. Apparently healthy volunteers were recruited and ECGs were first transferred...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章,多中心研究

    doi:10.1016/j.jelectrocard.2015.04.013

    authors: Macfarlane PW,Lloyd SM,Singh D,Hamde S,Clark E,Devine B,Francq BG,Kumar V

    更新日期:2015-07-01 00:00:00

  • Quantitative assessment of 12-lead ECG synthesis using CAVIAR.

    abstract::The objective of this study is to assess the performance of patient-specific segment-specific (PSSS) synthesis in QRST complexes using CAVIAR, a new method of the serial comparison for electrocardiograms and vectorcardiograms. A collection of 250 multi-lead recordings from the Common Standards for Quantitative Electro...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/0022-0736(92)90080-j

    authors: Scherer JA,Rubel P,Fayn J,Willems JL

    更新日期:1992-01-01 00:00:00

  • An adaptive QRS detection algorithm for ultra-long-term ECG recordings.

    abstract:BACKGROUND:Accurate detection of QRS complexes during mobile, ultra-long-term ECG monitoring is challenged by instances of high heart rate, dramatic and persistent changes in signal amplitude, and intermittent deformations in signal quality that arise due to subject motion, background noise, and misplacement of the ECG...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/j.jelectrocard.2020.02.016

    authors: Malik J,Soliman EZ,Wu HT

    更新日期:2020-01-01 00:00:00

  • ST-segment deviation pattern of takotsubo cardiomyopathy similar to acute pericarditis: diffuse ST-segment elevation.

    abstract:BACKGROUND:Possible similarities or differences in the ST- and PR-segment deviations in the electrocardiogram of takotsubo cardiomyopathy (TTC) and acute pericarditis (AP) are not well defined. METHODS:We compared different parameters of the admission electrocardiogram in eight patients with TTC and eight patients wit...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/j.jelectrocard.2012.11.013

    authors: Zhong-qun Z,Chong-quan W,Sclarovsky S,Nikus KC,Chao-rong H,Shan M

    更新日期:2013-03-01 00:00:00

  • Exercise training slows down heart rate and improves deceleration and acceleration capacity in patients with heart failure.

    abstract::Controlled physical training has been shown to be a valuable therapeutic addition to a pharmacological treatment in patients with chronic heart failure (CHF). It is speculated that repeated physical training can improve the autonomic modulation of the cardiovascular system in patients with CHF. The present study evalu...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.jelectrocard.2012.01.002

    authors: Ricca-Mallada R,Migliaro ER,Piskorski J,Guzik P

    更新日期:2012-05-01 00:00:00

  • Transient ST-segment elevation in subarachnoid hemorrhage.

    abstract::Electrocardiographic manifestation mimicking the hyperacute phase of myocardial infarction and the electrical alternans of the elevated ST-segment in association with subarachnoid hemorrhage were reported in two patients with no evidence of heart disease. In both cases the ST-segment changes were transient and there w...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/0022-0736(89)90082-4

    authors: Nakamura Y,Kaseno K,Kubo T

    更新日期:1989-04-01 00:00:00

  • A method for assembling a collaborative research team from multiple disciplines and academic centers to study the relationships between ECG estimation and MRI measurement of myocardial infarct size.

    abstract::A method has been developed for establishing a "University Without Walls" for the purpose of studying the relationship between electrocardiographic estimation and magnetic resonance imaging measurements of myocardial infarct size. The research team includes faculty and students from 4 medical centers, with expertise e...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1054/jelc.2001.28810

    authors: Wagner GS,Engblom H,Billgren T,Carlsson M,Hedstrom E,Ugander M,Selvester RH,Arheden H,Eisenstein E,Kasper J,White R

    更新日期:2001-01-01 00:00:00

  • Evidence for local cardiac effects in electrocardiograms from a large electrode array.

    abstract::The sensitivity of an extensive electrocardiographic examination to local cardiac regions was evaluated by comparison with findings in vectorcardiographic leads. Evaluation consisted of comparing QRS areas during different ventricular activation patterns. The ratio of areas from the vector-cardiogram (VCG) and extensi...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/s0022-0736(76)80009-x

    authors: Abildskov JA

    更新日期:1976-01-01 00:00:00

  • Successful epicardial ablation for ventricular tachycardia originating from the true apex of apical aneurysm associated with hypertrophic cardiomyopathy.

    abstract::Hypertrophic cardiomyopathy (HCM) with apical aneurysm (AA) is rare, but has been reported to be associated with refractory ventricular tachycardias (VTs). Majority of such cases had a central isthmus of the reentry circuit on the border zone of AA. In this report, we describe a rare case of the successful epicardial ...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/j.jelectrocard.2020.06.014

    authors: Nakao M,Watanabe M,Kamada R,Hagiwara H,Takahashi Y,Koya T,Kadosaka T,Koizumi T,Hirose M,Anzai T

    更新日期:2020-01-01 00:00:00

  • An approach to direct detection of sinus nodal activity in man.

    abstract::We are reporting a series of 13 out of a total of 16 patients in whom sinus nodal activity was recorded with the use of intra-atrial electrodes, during diagnostic His-bundle electrocardiography investigations. The protocol consisted of the simultaneous monitoring of the following intra-atrial points: high right atrium...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/s0022-0736(79)80002-3

    authors: Hombach V,Gil-Sanchez D,Zanker R,Behrenbeck DW,Tauchert M,Hilger HH

    更新日期:1979-10-01 00:00:00

  • Differences between supine and sitting Frank-lead electrocardiograms.

    abstract::Frank-lead electrocardiograms (ECGs) were recorded from 59 adult males with suspected coronary artery disease. Three records were recorded consecutively on frequency modulated tape for each patient in (1) supine position, (2) sitting position with arms relaxed, and (3) sitting position on bicycle with arms on bicycle ...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/s0022-0736(76)80021-0

    authors: Shapiro W,Berson AS,Pipberger HV

    更新日期:1976-01-01 00:00:00

  • Noninvasive risk stratification in postinfarction patients with severe left ventricular dysfunction and methodology of the MADIT II noninvasive electrocardiology substudy.

    abstract::Sudden cardiac death occurs as a result of a complex interplay of changes in myocardial substrate, imbalance of autonomic regulation of the heart, and myocardial vulnerability. Noninvasive electrocardiology serves as a comprehensive tool for investigating factors representing mechanistic pathways leading to cardiac ev...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.jelectrocard.2003.09.022

    authors: Zareba W,Moss AJ

    更新日期:2003-01-01 00:00:00

  • ECG observations in Tibetan and Han residents of Lhasa.

    abstract::In order to compare the prevalence of electrocardiographic (ECG) abnormalities suggestive of right ventricular hypertrophy in native and immigrant populations residing at high altitude, a retrospective review was undertaken of data obtained from a random survey of healthy volunteers and persons with chronic mountain s...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:

    authors: Halperin BD,Sun S,Zhuang J,Droma T,Moore LG

    更新日期:1998-07-01 00:00:00

  • Supernormal conduction in a case of Mobitz type II atrioventricular block.

    abstract::A 52-year-old woman exhibited Mobitz type II atrioventricular block with right bundle branch block and 1:1 atrioventricular conduction at or slower than 80 beats/min. Electrophysiologic study revealed transient HV interval block followed by recovery from the block at shorter coupling intervals without prolongation of ...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/s0022-0736(98)90009-7

    authors: Ayusawa M,Sakurada H,Hiyoshi Y,Sumitomo N,Okazaki H,Motomiya T,Sugiura M,Hiraoka M

    更新日期:1998-01-01 00:00:00

  • Effective extraction of diagnostic ECG waveform information using orthonormal basis functions derived from body surface potential maps.

    abstract::A common basis of orthogonal waveform functions was derived from 128 lead body surface potential maps of 405 subjects. Twelve such orthogonal functions or frames were adequate for reconstruction of original ECGs from the beginning of QRS to the end of T. A larger number of frames (18) was required when basis functions...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/s0022-0736(85)80016-9

    authors: Kornreich F,Rautaharju PM,Warren JW,Horacek BM,Dramaix M

    更新日期:1985-10-01 00:00:00

  • Dual effects of concealed A-V nodal conduction in man.

    abstract::An interpolated premature ventricular contraction (PVC) may produce either complete block of the next sinus impulse or depression of A-V nodal conduction with a prolonged A-H interval. When a PVC results in partial depression of a A-V nodal conduction, the effect on subsequent premature atrial stimuli is unknown. The ...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章

    doi:10.1016/s0022-0736(77)80025-3

    authors: Bissett JK,Kane JJ,de Soyza N,McConnell J,Schmitt N

    更新日期:1977-01-01 00:00:00

  • Association between QRS duration and outcome with cardiac resynchronization therapy: a systematic review and meta-analysis.

    abstract:PURPOSE:We conducted a systematic review and meta-analysis of randomized and observational studies to evaluate the associations between QRS duration (QRSd) at baseline or in follow-up and outcomes with cardiac resynchronization therapy (CRT). METHODS:We searched online databases to December 2010 and included 6 randomi...

    journal_title:Journal of electrocardiology

    pub_type: 杂志文章,meta分析,评审

    doi:10.1016/j.jelectrocard.2012.12.003

    authors: Bryant AR,Wilton SB,Lai MP,Exner DV

    更新日期:2013-03-01 00:00:00