Iomeprol and iopamidol in cardiac angiography: a randomised, double-blind, parallel-group comparison.

Abstract:

:During cardiac angiography, hemodynamic alterations and surface electrocardiographic changes are common, predictable and dose-related adverse reactions to radiocontrast media. High osmolality, inadequate sodium content and local transient hypocalcemia are thought to be the main mechanisms responsible for these untoward cardiovascular effects. The purpose of this double-blind, parallel-group trial was to compare the hemodynamic and electrocardiographic responses to cardiac and selective coronary artery injection of iomeprol 400 (400 mgI/ml) and iopamidol 370 (370 mgI/ml). One-hundred consenting adult inpatients were randomised to receive iomeprol 400 (41 males, nine females; mean age, 56.6 years) or iopamidol 370 (46 males, four females; mean age, 57.6 years). Both agents produced minor and transient hemodynamic and electrophysiological effects. Following left ventriculography, iopamidol 370 produced a significantly greater increase in LVEDP than iomeprol 400 (mean increases after first and second left ventriculogram: 2.5 and 4.6 mmHg with iomeprol 400, 3.3 and 9.9 mmHg with iopamidol 370, P = 0.027). The QT-interval was more affected by iopamidol 370 than by iomeprol 400. However, post-contrast prolongation of the QT-interval was not significant with either agent, nor were there any significant T-wave, ST-segment or RR-interval changes associated with the injection of the test compounds. No serious adverse events occurred throughout the study. Mild pain was complained by only one patient, while most patients reported mild to moderate sensation of heat. Image quality of the vast majority of the procedures was rated as good or excellent in both patient groups.(ABSTRACT TRUNCATED AT 250 WORDS)

journal_name

Eur J Radiol

authors

Fattori R,Piva R,Schicchi F,Pancrazi A,Gabrielli G,Marzocchi A,Piovaccari G,Blandini A,Magnani B

doi

10.1016/0720-048x(94)90095-7

subject

Has Abstract

pub_date

1994-05-01 00:00:00

pages

S61-6

eissn

0720-048X

issn

1872-7727

pii

0720-048X(94)90095-7

journal_volume

18 Suppl 1

pub_type

临床试验,杂志文章,随机对照试验
  • Quantitative in vivo imaging of tissue factor expression in glioma using dynamic contrast-enhanced MRI derived parameters.

    abstract:OBJECTIVE:Tissue Factor (TF) has been well established in angiogenesis, invasion, metastasis, and prognosis in glioma. A noninvasive assessment of TF expression status in glioma is therefore of obvious clinical relevance. Dynamic contrast-enhanced (DCE) MRI parameters have been used to evaluate microvascular characteri...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2017.06.006

    authors: Chen X,Xie T,Fang J,Xue W,Tong H,Kang H,Wang S,Yang Y,Xu M,Zhang W

    更新日期:2017-08-01 00:00:00

  • New-born infants with severe hyaline membrane disease: radiological evaluation during high frequency oscillatory versus conventional ventilation.

    abstract:OBJECTIVE:The aim of our study was to determine the impact of treatment with exogenous surfactant (ES) and high frequency oscillatory ventilation (HFOV) on the radiological appearance and clinical course of hyaline membrane disease (HMD) in new-born infants. MATERIALS AND METHODS:New-born infants (18) (median weight, ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/s0720-048x(97)00153-8

    authors: Helbich TH,Popow C,Dobner M,Wunderbaldinger P,Zekert M,Herold CJ

    更新日期:1998-10-01 00:00:00

  • Reducing artifacts from total hip replacements in dual layer detector CT: Combination of virtual monoenergetic images and orthopedic metal artifact reduction.

    abstract:PURPOSE:To evaluate the reduction of artifacts caused by total hip replacements (THR) in dual-layer DECT (DLCT) provided by the combination of virtual monoenergetic images (VMI) and orthopedic metal artifact reduction (MAR). MATERIALS AND METHODS:A total of 24 consecutive patients carrying THR, who received DLCT, were...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2018.12.008

    authors: Neuhaus V,Grosse Hokamp N,Zopfs D,Laukamp K,Lennartz S,Abdullayev N,Maintz D,Borggrefe J

    更新日期:2019-02-01 00:00:00

  • 68Ga-PSMA PET/MRI for the diagnosis of primary and biochemically recurrent prostate cancer: A meta-analysis.

    abstract:PURPOSE:Our meta-analysis aimed to evaluate the diagnostic performance of 68Ga-labelled prostate-specific membrane antigen ligand positron emission tomography/magnetic resonance imaging (68Ga-PSMA PET/MRI) in patients with primary and biochemically recurrent prostate cancer (PCa). METHODS:We searched for relevant arti...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2020.109131

    authors: Wang R,Shen G,Yang R,Ma X,Tian R

    更新日期:2020-09-01 00:00:00

  • Quantitative computed tomography measurements to evaluate airway disease in chronic obstructive pulmonary disease: Relationship to physiological measurements, clinical index and visual assessment of airway disease.

    abstract:PURPOSE:To correlate currently available quantitative CT measurements for airway disease with physiological indices and the body-mass index, airflow obstruction, dyspnea, and exercise capacity (BODE) index in patients with chronic obstructive pulmonary disease (COPD). MATERIALS AND METHODS:This study was approved by o...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2016.09.010

    authors: Nambu A,Zach J,Schroeder J,Jin G,Kim SS,Kim YI,Schnell C,Bowler R,Lynch DA

    更新日期:2016-11-01 00:00:00

  • Endovascular stent-graft management of thoracic aortic diseases.

    abstract::The traditional standard therapy for descending thoracic aortic aneurysm (TAA) is open operative repair with graft replacement of the diseased aortic segment. Despite important advances in surgical techniques, anesthetic management, and post-operative care over the last 30 years, the mortality and morbidity of surgery...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/s0720-048x(01)00341-2

    authors: Dake MD

    更新日期:2001-07-01 00:00:00

  • Quantitative CT detects changes in airway dimensions and air-trapping after bronchial thermoplasty for severe asthma.

    abstract:OBJECTIVES:Bronchial thermoplasty (BT) can be considered in the treatment of severe asthma to reduce airway smooth muscle mass and bronchoconstriction. We hypothesized that BT may thus have long-term effects on airway dimensions and air-trapping detectable by quantitative computed tomography (QCT). METHODS:Paired in- ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2018.08.007

    authors: Konietzke P,Weinheimer O,Wielpütz MO,Wagner WL,Kaukel P,Eberhardt R,Heussel CP,Kauczor HU,Herth FJ,Schuhmann M

    更新日期:2018-10-01 00:00:00

  • Protoneus-sequence: extended fluid-attenuated inversion recovery MR imaging without and with contrast enhancement.

    abstract::Fluid-attenuated inversion recovery imaging (=flair imaging) is widely used as primary screening sequence in various investigation protocols, due to its high lesion contrast and sensitivity in detection of parenchymatous and leptomeningeal disease. An additional increase of sensitivity for detection of lesions may be ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2004.11.008

    authors: Nasel C

    更新日期:2005-08-01 00:00:00

  • How does nose blowing effect the computed tomography of paranasal sinuses in chronic sinusitis?

    abstract:OBJECTIVE:Our aim was to determine whether inward or outward movement of the secretions in the paranasal sinuses due to nose blowing after nasal decongestion has any effect on the paranasal sinus computed tomography (CT) images in patients with sinusitis and to asses whether nose blowing may result in misdiagnosis or o...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2004.04.003

    authors: Savranlar A,Uzun L,Ugur MB,Mahmutyazicioglu K,Ozer T,Gundogdu S

    更新日期:2005-02-01 00:00:00

  • Focal liver lesion detection and characterization: comparison of non-contrast enhanced and SPIO-enhanced diffusion-weighted single-shot spin echo echo planar and turbo spin echo T2-weighted imaging.

    abstract:PURPOSE:To compare lesion conspicuity and image quality between single-shot spin echo echo planar imaging (SS SE-EPI) before, immediately and 5min after intravenous (IV) injection of superparamagnetic iron oxide (SPIO) for detecting and characterizing focal liver lesions (FLLs). MATERIALS AND METHODS:Twenty-five patie...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2008.09.005

    authors: Coenegrachts K,Matos C,ter Beek L,Metens T,Haspeslagh M,Bipat S,Stoker J,Rigauts H

    更新日期:2009-12-01 00:00:00

  • 3T Double Inversion Recovery Magnetic Resonance Imaging: diagnostic advantages in the evaluation of cortical development anomalies.

    abstract:PURPOSE:The aim of this work was to investigate the diagnostic value of the DIR sequence at 3T MR imaging operating in the evaluation of cortical development anomalies. METHODS:We studied 40 patients, with a previous diagnosis of cortical dysplasia, by FLAIR-3D, DIR, FSE T2 and MPR-GE T1 sequences at 3T MRI. Two indep...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2016.02.018

    authors: Granata F,Morabito R,Mormina E,Alafaci C,Marino S,Laganà A,Vinci SL,Briguglio M,Calamuneri A,Gaeta M,Salpietro V,Longo M

    更新日期:2016-05-01 00:00:00

  • Is magnetic resonance imaging of hepatic hemangioma any different in liver fibrosis and cirrhosis compared to normal liver?

    abstract:PURPOSE:To compare qualitative and quantitative magnetic resonance (MR) imaging characteristics of hepatic hemangiomas in patients with normal, fibrotic and cirrhotic livers. MATERIALS AND METHODS:Retrospective, institutional review board approved study (waiver of informed consent). Eighty-nine consecutive patients wi...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2015.01.016

    authors: Duran R,Ronot M,Di Renzo S,Gregoli B,Van Beers BE,Vilgrain V

    更新日期:2015-05-01 00:00:00

  • Pelvic magnetic resonance imaging angioanatomy of the arterial blood supply to the penis in suspected prostate cancer patients.

    abstract:PURPOSE:To describe the internal pudendal artery (IPA) and accessory pudendal artery (APA) detected by magnetic resonance (MR) angiography to help surgeons to find and preserve them during radical prostatectomy (RP). MATERIALS AND METHODS:Constrast-enhanced MR 3.0 T angiography of the pelvis were performed in 111 male...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2015.01.017

    authors: Thai CT,Karam IM,Nguyen-Thi PL,Lefèvre F,Hubert J,Felblinger J,Eschwège P

    更新日期:2015-05-01 00:00:00

  • Accelerated MRI of the knee. Quality and efficiency of compressed sensing.

    abstract:PURPOSE:To evaluate potential clinical acceleration factors of Compressed SENSE (CS)1 in direct comparison with SENSE for fat saturated (fs)2, proton density-weighted (PD)3 2D and 3D sequences of the knee. METHOD:Twenty healthy volunteers were scanned with a 3 T scanner, all receiving a standard, fs 2D PD, three CS (C...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2020.109273

    authors: Iuga AI,Abdullayev N,Weiss K,Haneder S,Brüggemann-Bratke L,Maintz D,Rau R,Bratke G

    更新日期:2020-11-01 00:00:00

  • Technical challenges of coronary CT angiography: today and tomorrow.

    abstract::Rapid advancements in multidetector row computed tomography (MDCT) are beginning to revolutionise cardiac imaging applications. As a consequence, coronary CT angiography (CTA) is fast emerging as a highly effective, noninvasive imaging technique for the assessment of coronary artery disease (CAD). Technology is improv...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2010.02.011

    authors: Hassan A,Nazir SA,Alkadhi H

    更新日期:2011-08-01 00:00:00

  • Differentiation between benign and malignant colon tumors using fast dynamic gadolinium-enhanced MR colonography; a feasibility study.

    abstract:BACKGROUND:Colorectal cancer will present itself as a bowel obstruction in 16-23% of all cases. However, not all obstructing tumors are malignant and the differentiation between a benign and a malignant tumor can be difficult. The purpose of our study was to determine whether fast dynamic gadolinium-enhanced MR imaging...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2009.03.033

    authors: Achiam MP,Andersen LP,Klein M,Løgager V,Chabanova E,Thomsen HS,Rosenberg J

    更新日期:2010-06-01 00:00:00

  • Application of CT perfusion imaging to the histological differentiation of adrenal gland tumors.

    abstract:BACKGROUND:CT perfusion imaging has been used in diagnosis and classification of tumors widely and in assess tumor angiogenesis in some organs. However, there are few reports describing CT perfusion imaging of adrenal gland tumors. OBJECTIVE:This study aimed to evaluate the application of CT perfusion imaging in analy...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2010.12.072

    authors: Qin HY,Sun HR,Li YJ,Shen BZ

    更新日期:2012-03-01 00:00:00

  • Whole-body MRI as a screening tool?

    abstract::Screening (early detection of disease in asymptomatic groups of persons) with whole-body MR (wb-MR) has only recently become possible. Technical requirements include extended scanner table range and extended coverage with surface coils. This allows for examining the whole body without repositioning the patient. wb-MR ...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2009.02.011

    authors: Ladd SC

    更新日期:2009-06-01 00:00:00

  • MR imaging of the biliary tract with Gd-EOB-DTPA: effect of liver function on signal intensity.

    abstract:OBJECTIVE:To quantitatively evaluate the signal intensity of the biliary tract in gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance (MR) imaging and to investigate the effect of liver function on the signal intensity of the biliary tract. MATERIALS AND METHODS:A tota...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2009.08.008

    authors: Takao H,Akai H,Tajima T,Kiryu S,Watanabe Y,Imamura H,Akahane M,Yoshioka N,Kokudo N,Ohtomo K

    更新日期:2011-02-01 00:00:00

  • A comparative analysis of double inversion recovery TFE and TSE sequences on carotid artery wall imaging.

    abstract:OBJECTIVE:To analyze the characteristics of double inversion recovery (DIR) turbo field echo (TFE) and turbo spin echo (TSE) sequences and explore the value of double inversion recovery TFE sequence on carotid artery wall imaging. PATIENTS AND METHODS:56 patients (32 males and 24 females, aged 31-76 years with a mean ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2010.12.048

    authors: Chen J,Di YJ,Bu CQ,Zhang YF,Li SH

    更新日期:2012-02-01 00:00:00

  • A comparative study to validate the use of ultrasonography and computed tomography in patients with post-operative intra-abdominal sepsis.

    abstract:PURPOSE:To validate abdominal ultrasonography and helical computed tomography in detecting causes for sepsis in patients after abdominal surgery and to determine improved criteria for its use. MATERIALS AND METHODS:Eighty-five consecutive surgical patients primarily operated for non-infectious disease were included in...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2004.08.004

    authors: Go HL,Baarslag HJ,Vermeulen H,Laméris JS,Legemate DA

    更新日期:2005-06-01 00:00:00

  • Reject analysis: a pilot programme for image quality management.

    abstract::The radiographic film wastage and the different parameters affecting this wastage were analysed for a 9-week period at a 600-bed University Hospital. An overall reject rate of 7.6% was found. The different reasons for rejection were evaluated, while retake rate, relation between working experience of the personnel, am...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/0720-048x(91)90067-6

    authors: Arvanitis TN,Parizel PM,Degryse HR,De Schepper AM

    更新日期:1991-05-01 00:00:00

  • Comparison of diagnostic performance between two prostate imaging reporting and data system versions: A systematic review.

    abstract:OBJECTIVE:To compare the diagnostic performance between Prostate Imaging Reporting and Data System version 1(PI-RADS v1) and PI-RADS v2 for detection of prostate cancer (PCa). METHODS:A systematic literature search was performed from inception to September 31, 2018, in following databases MEDLINE, EMBASE, Cochrane Lib...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2019.03.016

    authors: Li W,Xin C,Zhang L,Dong A,Xu H,Wu Y

    更新日期:2019-05-01 00:00:00

  • Scaphoid nonunions treated with vascularised bone grafts: MRI assessment.

    abstract:PURPOSE:To assess the value of MR imaging (MRI) with regard to union, graft viability and proximal pole bone marrow status, after use of vascularized bone grafts for treating scaphoid nonunions. MATERIALS AND METHODS:Vascularized bone grafts from the distal radius were used to treat 47 scaphoid nonunions resulting fro...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2004.01.017

    authors: Dailiana ZH,Zachos V,Varitimidis S,Papanagiotou P,Karantanas A,Malizos KN

    更新日期:2004-06-01 00:00:00

  • Clinical value of Doppler ultrasound in the first two months after kidney transplant.

    abstract::The ability of PI measurements to differentiate between acute rejection and ATN was investigated in 37 patients, who were frequently examined by duplex Doppler after kidney transplant. Absolute PI values as well as increase in PI were recorded and the clinical course was correlated with these pulsatility measurements....

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/0720-048x(92)90057-g

    authors: van Leeuwen MS,Hené RJ,Muller AF,Beek FJ,Meyer R,Ganpat R

    更新日期:1992-01-01 00:00:00

  • High resolution magnetic resonance imaging of urethral anatomy in continent nulliparous pregnant women.

    abstract:INTRODUCTION:To quantify the distribution of morphologic appearances of urethral anatomy and measure variables of urethral sphincter anatomy in continent, nulliparous, pregnant women by high resolution magnetic resonance imaging (MRI). MATERIALS AND METHODS:We studied fifteen women during their first pregnancy. We def...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2010.08.046

    authors: Preyer O,Brugger PC,Laml T,Hanzal E,Prayer D,Umek W

    更新日期:2011-12-01 00:00:00

  • The physics of the oscillating bubble made simple.

    abstract::The physics of bubbles and of their oscillations is extremely complex and attempts at its mathematical description are generally inaccessible. Yet some idea, in broad descriptive terms at least, is very helpful in understanding bubble phenomena of clinical interest. A brief attempt to provide such a description is giv...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/s0720-048x(02)00023-2

    authors: Dawson P

    更新日期:2002-03-01 00:00:00

  • Using a single abdominal computed tomography image to differentiate five contrast-enhancement phases: A machine-learning algorithm for radiomics-based precision medicine.

    abstract:PURPOSE:The clinical adoption of quantitative imaging biomarkers (radiomics) has established the need for high quality contrast-enhancement in medical images. We aimed to develop a machine-learning algorithm for Quality Control of Contrast-Enhancement on CT-scan (CECT-QC). METHOD:Multicenter data from four independent...

    journal_title:European journal of radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1016/j.ejrad.2020.108850

    authors: Dercle L,Ma J,Xie C,Chen AP,Wang D,Luk L,Revel-Mouroz P,Otal P,Peron JM,Rousseau H,Lu L,Schwartz LH,Mokrane FZ,Zhao B

    更新日期:2020-04-01 00:00:00

  • Liver fat quantification: Comparison of dual-echo and triple-echo chemical shift MRI to MR spectroscopy.

    abstract:PURPOSE:To assess the diagnostic value of MRI using dual-echo (2PD) and triple-echo (3PD) chemical shift imaging for liver fat quantification against multi-echo T2 corrected MR spectroscopy (MRS) used as the reference standard, and examine the effect of T2(*) imaging on accuracy of MRI for fat quantification. MATERIAL...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2015.05.001

    authors: Satkunasingham J,Besa C,Bane O,Shah A,de Oliveira A,Gilson WD,Kannengiesser S,Taouli B

    更新日期:2015-08-01 00:00:00

  • CT diagnosis of pedunculated liver tumours.

    abstract::Liver tumours with extrahepatic location are uncommon. They show specific CT criteria with respect to blood supply. Various CT criteria have been analysed in 10 tumours, including three hepatocellular adenomas, two focal nodular hyperplasias, four cavernous haemangiomas and one hepatocellular carcinoma. Correct diagno...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:

    authors: Lüning M,Mühler A

    更新日期:1988-11-01 00:00:00