Abstract:
:Linear accelerator workloads for each available photon energy are important quantities to know for radiation safety considerations, and presented is a technique to measure the workload using paired detectors. The signals from the two detectors can give sufficient information to separate the signal contributions from 6 and 18 MV photon fields and, combined with a signal-per-monitor-unit calibration factor, yields the number of monitor units delivered for each energy. CR-39 NTD is a neutron detector chosen for its ability to discriminate between 6 MV and 18 MV radiation fields. TLD-100 is a detector responsive to both 6 MV and 18 MV fields. These appeared to be a good choice for a detector pair. This experiment had both failures and successes to report. The CR-39 NTD and TLD-100 were not a successful pairing. The CR-39 NTD signals saturated under this experiment's exposure conditions. The TLD-100 had a combination of detector noise and detector sensitivity that made extracting the 6 MV signal from the total signal impractical, unless the total exposure was overwhelmingly 6 MV. Nevertheless, the TLD-100 proved to be excellent for determining workloads when it was exposed to a single energy with 1% accuracy and 3% precision. The theory and data analysis showed the importance of understanding the noise contributions for the more general problem of pairing any two detector types. This experiment indicated the TLD-100 could be an excellent detector choice if paired with a suitable second detector.
journal_name
Health Physjournal_title
Health physicsauthors
Corns R,Schroeder C,Sandhu G,Henderson K,McKay Idoi
10.1097/HP.0000000000000984subject
Has Abstractpub_date
2019-09-01 00:00:00pages
233-241issue
3eissn
0017-9078issn
1538-5159journal_volume
117pub_type
杂志文章相关文献
HEALTH PHYSICS文献大全abstract::Low-dose radiation is widely used across the world for the diagnosis of many diseases by means of a variety of imaging technologies. However, the harmful effects of exposure to low-dose radiation during medical examination remain controversial. The authors studied the effects of medical diagnostic low-dose x rays (i.e...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/HP.0000000000000647
更新日期:2017-05-01 00:00:00
abstract::Everyone will agree that specialized computer programs have done away with the many tedious tasks associated with manually keeping track of radioisotopes. Enhanced electronic programs have virtually cut the time of managing radioisotopes. Agriculture and Agri-Food, Canada's (AAFC) program for the management of radiois...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/01.HP.0000308501.32700.f1
更新日期:2008-05-01 00:00:00
abstract::Monte Carlo simulation techniques using a Monte Carlo N-Particle code (MCNP5) analyzed six Source Production & Equipment Co., Inc., Se industrial radiography sources to determine an appropriate air kerma rate constant for Se, factoring in source encapsulation and compared to a theoretical approximation. Based on this ...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/HP.0b013e318284592c
更新日期:2013-05-01 00:00:00
abstract::In recent years, regulatory emphasis on the prevention of loss, theft and intentional misuse of radioactive materials at academic institutions has forced radiation safety personnel to devote increasing amounts of time and effort to address security issues. NRC regulations require that radioactive materials used or sto...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/00004032-200311002-00009
更新日期:2003-11-01 00:00:00
abstract::While much of the language used to express the concepts of radiation protection works effectively, there are many ill-chosen names and phrases and much jargon that permeate our professional speech and writing. From the oxymoron "internal exposure" to the "snarl word" "decay," there is much room for improvement. This e...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/00004032-200203000-00010
更新日期:2002-03-01 00:00:00
abstract::The ICRP effective dose equivalent has been compared with a weighted dose equivalent, computed by treating the entire remainder instead of the sample of five remainder organs in the ICRP method as uniformly radiosensitive, for dose distributions from three common diagnostic exposures: chest, dental full-mouth and dent...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/00004032-198904000-00012
更新日期:1989-04-01 00:00:00
abstract::The plant uptake of 244Cm, 137Cs, 238Pu and 90Sr was measured for trees in a flood plain forest whose soils were contaminated by aqueous discharges from a nuclear-fuel chemical separations facility. Uptake of the naturally occurring radionuclide 226Ra was also measured. The relative availability of the nuclides was 23...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/00004032-198409000-00003
更新日期:1984-09-01 00:00:00
abstract::Power-frequency (50/60 Hz) magnetic fields produced by electric blankets are estimated from data on blanket design using a three-dimensional computer model. Maximum, minimum, and volume-average fields within human forms are presented as a function of blanket type and a number of geometric factors including body size, ...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/00004032-199004000-00012
更新日期:1990-04-01 00:00:00
abstract::Sandia National Laboratories' Z-Machine is the world's most powerful electrical device, and experiments have been conducted that make it the world's most powerful radiation source. Because Z-Machine is used for research, an assortment of materials can be placed into the machine; these materials can be subjected to a r...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/HP.0b013e31827126f1
更新日期:2013-02-01 00:00:00
abstract::A comparison of the risk coefficients for 239Pu- or 226Ra-induced bone cancer in two canine breeds, one with a relatively low (beagle) and the other with a very high (St. Bernard) natural incidence, indicated only slightly higher risk in the giant breed. The differences in risk for skeletal malignancy in 239Pu and 226...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/00004032-199710000-00014
更新日期:1997-10-01 00:00:00
abstract::Unlike detached or semi-detached houses, the main source of indoor radon in high-rise buildings is the building material. Radon released from the building material will be removed by ventilation, either forced or natural, so that its concentration, its progeny's concentration, and the equilibrium between the two will ...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/00004032-199809000-00010
更新日期:1998-09-01 00:00:00
abstract::Studies of the physical and chemical properties of radioactive aerosols produced in different work environments were made at Chin-Shan nuclear power plant in Taiwan. These properties, including particle mass- and activity-size distributions, elemental and radionuclide compositions, and solubility lung class, are essen...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/00004032-199308000-00003
更新日期:1993-08-01 00:00:00
abstract::The use of x-ray generators for diagnostic radiology in the medical sector in Cameroon, Central Africa, is wide spread and on the increase in recent times. Regulatory control of x-ray machines used in medical sector has been achieved in the Littoral Region of Cameroon by means of notification and authorization systems...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/HP.0000000000000713
更新日期:2017-11-01 00:00:00
abstract::Reliable radon laboratory operations motivated the construction of three radon gas calibration chambers. One chamber is used for background calibrations while the other two cover a radon gas concentration range of 110 to >5,550 Bq m(-3) (3-150 pCi L(-1)). The chambers entered commercial service, for tertiary radon cal...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/01.HP.0000267006.55621.2f
更新日期:2007-08-01 00:00:00
abstract::Lifetime follow-up of USTUR Case 246 demonstrated the lack of severe biological effects resulting from his exposure to 241Am. Deterministic effects observed were limited to hematological changes, including lymphopenia and thrombocytopenia. These hematological changes were consistent with those observed in experimental...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/00004032-199509000-00005
更新日期:1995-09-01 00:00:00
abstract::This paper describes an investigation into the distribution of radiation doses to workers, undertaken at the request of ICRP Committee 4. Three main questions are considered. Firstly, the distribution of annual doses to workers is described. Doses are generally well below the ICRP dose limits and most are below 15 mSv...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/00004032-198611000-00002
更新日期:1986-11-01 00:00:00
abstract::The average absorbed dose due to DNA-bound 3H in a cell nucleus was estimated by a Monte Carlo simulation for a model nucleus which was assumed to be spheroidal. The shape of the cell nucleus was found to be of minor importance in determining the average absorbed dose. The volume of the cell nucleus was the major dose...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/00004032-198504000-00009
更新日期:1985-04-01 00:00:00
abstract::Releases of radioactive materials from the Mayak Production Association in 1949-1956 resulted in contamination of the Techa River; a nuclide of major interest was 90Sr, which downstream residents consumed with water from the river and with milk contaminated by cows' consumption of river water and contaminated pasture....
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/HP.0b013e318206d0ff
更新日期:2011-07-01 00:00:00
abstract::Assumptions supporting a chronic aqueous release methodology are inappropriate for estimating dose from accidental discharges. A method of modeling acute or accidental releases is being developed for predicting maximum individual dose. Standardization of consumption rates and usage factors for acute aqueous releases i...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/00004032-199206000-00011
更新日期:1992-06-01 00:00:00
abstract::Signal processing within a radiation detector affects detection efficiency. Currently, organizations such as private industry, the U.S. Navy, Army, and Air Force are coupling some detector systems with data collection devices to survey large land areas for radioactive contamination. As detector technology has advanced...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/HP.0000000000000298
更新日期:2015-07-01 00:00:00
abstract::Instrumentation and application methodologies for rapidly and accurately estimating individual ionizing radiation dose are needed for on-site triage in a radiological/nuclear event. One such methodology is an in vivo X-band, electron paramagnetic resonance, physically based dosimetry method to directly measure the rad...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/HP.0000000000000874
更新日期:2018-07-01 00:00:00
abstract::The life-time tumor dose-response relationships observed in beagles injected with 226Ra or fed 90Sr at the University of California, Davis, provide a basis for understanding the induction of bone cancer for these bone-seeking radionuclides and for scaling to people. In these studies 385 dogs were exposed to graded dos...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/00004032-198306001-00002
更新日期:1983-01-01 00:00:00
abstract:INTRODUCTION:Following critiques of multiple personal contamination events from entries into the Oak Ridge National Laboratory's Spallation Neutron Source Transfer Bay, it was considered that the most likely causes for contamination were personal protective clothing doffing errors or moisture (sweat) allowing contamina...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/HP.0000000000001275
更新日期:2020-08-01 00:00:00
abstract::The total ozone column of 265 ± 11 Dobson Units in the tropical-equatorial zones and 283 ± 16 Dobson Units in the subtropics of Brazil are among the lowest on Earth, and as a result, the prevalence of skin cancer due to solar ultraviolet radiation is among the highest. Daily erythemal doses in Brazil can be over 7,500...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/HP.0000000000000489
更新日期:2016-06-01 00:00:00
abstract::Monte Carlo neutron transport calculations were performed to obtain the neutron response functions of a superheated drop detector (SDD-100) that is surrounded by polyethylene of various thicknesses. The calculational results suggest that a SDD-100 surrounded by 2.54 cm of polyethylene gives the best dose-equivalent re...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/00004032-199203000-00001
更新日期:1992-03-01 00:00:00
abstract::A new modification of the prior human lung compartment plutonium model, Doses-2005, has been described. The modified model was named "Mayak Worker Dosimetry System-2008" (MWDS-2008). In contrast to earlier models developed for workers at the Mayak Production Association (Mayak PA), the new model more correctly describ...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/HP.0b013e31827dbf60
更新日期:2013-04-01 00:00:00
abstract::A case of plutonium deposition in man within the range of 190 Bq by inhalation from about 12 yr ago is reported. An estimate of systemic burden was made based on analyses of urine and faeces and the models of Langham, Beach/Dolphin, and Durbin while the individual was alive. This estimate was compared with autopsy fin...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/00004032-198404000-00008
更新日期:1984-04-01 00:00:00
abstract::As in the past, the principle role of the scientist in the courtroom is to assist attorneys, judges, and jurors in understanding the complex scientific and technical issues before them. In the last decade, however, changes in the law and the increasing technical complexity of many disputes have introduced new factors ...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/00004032-200109000-00008
更新日期:2001-09-01 00:00:00
abstract::A mathematical model of the process of collecting and analyzing a grab sample of radon decay products in air can be useful for a number ofpurposes. Among them is predicting the observed counts of alpha particles and/or beta particles (1) under various conditions of radon decay product equilibrium; (2) for various samp...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/00004032-200208001-00014
更新日期:2002-08-01 00:00:00
abstract::Soil permeability to air can increase substantially with measurement length scale. We tested the hypothesis that the scale effect could resolve large model underpredictions of radon and soil-gas entry into two experimental basement structures located in natural sandy-loam soil at a field site in Ben Lomond, CA. Previo...
journal_title:Health physics
pub_type: 杂志文章
doi:10.1097/00004032-199908000-00008
更新日期:1999-08-01 00:00:00