The Time Course of Radiation-induced Lung Injury in a Nonhuman Primate Model of Partial-body Irradiation With Minimal Bone Marrow Sparing: Clinical and Radiographic Evidence and the Effect of Neupogen Administration.

Abstract:

:The primary objectives of two companion manuscripts were to assess the natural history of delayed radiation-induced lung injury in a nonhuman primate model of acute high-dose, partial-body irradiation with 5% bone marrow sparing, to include the clinical, radiographic, and histopathological evidence and the effect of Neupogen administration on the morbidity and mortality. Nonhuman primates were exposed to 10.0 or 11.0 Gy with 6 MV linac-derived photons at approximately 0.80 Gy min. All nonhuman primates received subject-based, medical management. Subsets of nonhuman primates were administered Neupogen (10 μg kg) starting on day 1, day 3, or day 5 until recovery (absolute neutrophil count ≥ 1,000 cells μL for three consecutive days). Mortality due to multiple organ injury at 180 d study duration: Mortality at 180 d post either 10.0 Gy or 11.0 Gy was the consequence of concurrent injury due to the acute radiation syndrome (gastrointestinal and hematological) and delayed radiation-induced lung injury. The 180-d all-cause mortality observed in the control cohorts at 10.0 Gy (53%) or 11.0 Gy (86%) did not vary from cohorts that received Neupogen at any administration schedule. Mortality ranged from 43-50% (10 Gy) to 75-100% (11.0 Gy) in the Neupogen-treated cohorts. The study, however, was not powered to detect statistical significant differences between mortality in the control and Neupogen-treated cohorts. Clinical and radiographic evidence of radiation-induced lung injury: The mean nonsedated respiratory rate in the control cohorts exposed to 10 or 11 Gy increased from a baseline value of 37 breaths min to >60 breaths min within 103 d and 94 d postexposure, and the incidence of nonsedated respiratory rate > 80 breaths min was 50% and 70%, respectively. The mean duration of latency to development of clinical pneumonitis and/or fibrosis (nonsedated respiratory rate > 80 breaths min) was not significantly different between the 10.0-Gy or 11.0 Gy-cohorts (range 100-107 d). Neupogen (granulocyte colony-stimulating factor) administration had no apparent effect of the latency, incidence, or severity of nonsedated respiratory rate within either radiation dose or administration schedule. Computed tomography scans were obtained and images were analyzed for evidence of lung injury, e.g., pneumonitis and/or fibrosis, pleural and pericardial effusion. A quantitative, semiautomated method was developed based on differences in radiodensity (Hounsfield units) and lung morphology to extract the volume of pneumonitis/fibrosis and pleural effusion as indexed against total lung at each time point obtained. At both irradiation doses, 100% of the nonhuman primates surviving acute radiation syndrome manifested radiographic evidence of radiation-induced lung injury as pneumonitis and/or fibrosis. There was no apparent effect of Neupogen administration on the latency, incidence, severity, or progression of pneumonitis/fibrosis:total lung volume or pleural effusion:total lung volume at either exposure. A comparative review of the data illustrated the concomitant time course of increased mortality, nonsedated respiratory rate, and pneumonitis/fibrosis:total lung volume and pleural effusion:total lung volume consequent to 10.0-Gy or 11.0-Gy partial-body irradiation with 5% bone marrow sparing. All key parameters proceeded from a latent period of approximately 60 d followed by an increase in all three indices of clinical and radiographic evidence of radiation-induced lung injury within the next 60 d to 120 d postexposure. The subsequent time course and longitudinal analysis was influenced by the persistent progression of radiation-induced lung injury, administration of dexamethasone, and loss of nonhuman primates due to lethality. Companion paper: Lung and Heart Injury in a Nonhuman Primate Model of Partial-body Irradiation With Minimal Bone Marrow Sparing: Histopathological Evidence of Lung and Heart Injury (Parker et al. 2019): Note that the computed tomography-based radiodensity data do not permit differentiation of pneumonitis and fibrosis. The companion paper employed Masson's trichrome, collagen 1, and selected staining to identify the key time and incidence parameters relative to excessive collagen deposition indicative of fibrosis and associated histopathology in the lung. This histological database provided valuable longitudinal analysis in support of the clinical and radiographic evidence associated with the time course of radiation-induced lung injury.

journal_name

Health Phys

journal_title

Health physics

authors

MacVittie TJ,Farese AM,Parker GA,Jackson W 3rd

doi

10.1097/HP.0000000000000968

subject

Has Abstract

pub_date

2019-03-01 00:00:00

pages

366-382

issue

3

eissn

0017-9078

issn

1538-5159

journal_volume

116

pub_type

杂志文章
  • A consistent radionuclide vector after the Chernobyl accident.

    abstract::The radionuclide vector in the release plume from the destroyed unit 4 of the Chernobyl Nuclear Power Plant was assessed. Emphasis was laid on radionuclides relevant for the internal dose, including those with short half-lives, and on the radionuclide vector in the 30-km zone where practically no data in air or foodst...

    journal_title:Health physics

    pub_type: 杂志文章

    doi:10.1097/00004032-200202000-00002

    authors: Mück K,Pröhl G,Likhtarev I,Kovgan L,Meckbach R,Golikov V

    更新日期:2002-02-01 00:00:00

  • Overview of the National Cancer Institute's activities related to exposure of the public to fallout from the Nevada Test Site.

    abstract::The Department of Health and Human Services (DHHS) was directed by Congress to assess the risk of thyroid cancer from 131I associated with fallout from the atmospheric testing of nuclear weapons at the Nevada Test Site. The National Cancer Institute (NCI) was requested by DHHS to address Public Law 97-414, Section 7 (...

    journal_title:Health physics

    pub_type: 杂志文章

    doi:10.1097/00004032-199011000-00002

    authors: Wachholz BW

    更新日期:1990-11-01 00:00:00

  • A study of amplifying the response of an LR115 solid state track detector by combining it with electret.

    abstract::Radon progeny are positively charged immediately after formation. A negatively charged electret collects radon progeny atoms which are produced in the diffusion chamber. The detector sensitivity may be increased by using an electret in front of solid state nuclear track detector. Dependence of detection sensitivity on...

    journal_title:Health physics

    pub_type: 杂志文章

    doi:10.1097/00004032-199512000-00008

    authors: Nikezić D,Krstić D

    更新日期:1995-12-01 00:00:00

  • PRex: An Experiment to Investigate Detection of Near-field Particulate Deposition from a Simulated Underground Nuclear Weapons Test Vent.

    abstract::A radioactive particulate release experiment to produce a near-field ground deposition representative of small-scale venting from an underground nuclear test was conducted to gather data in support of treaty capability development activities. For this experiment, a CO2-driven "air cannon" was used to inject (140)La, a...

    journal_title:Health physics

    pub_type: 杂志文章

    doi:10.1097/HP.0000000000000506

    authors: Keillor ME,Arrigo LM,Baciak JE,Chipman V,Detwiler RS,Emer DF,Kernan WJ,Kirkham RR,MacDougall MR,Milbrath BD,Rishel JP,Seifert A,Seifert CE,Smart JE

    更新日期:2016-05-01 00:00:00

  • Measurement of 226Ra and 228Ra in water by gamma-ray counting after preconcentration on ion-exchange resin.

    abstract::A rugged resin concentration method followed by gamma counting was developed for measuring 226Ra and 228Ra in drinking water. Using typical distribution system pressure, 310 kPa (45 psig), radium in a 20-L sample was concentrated 100-fold onto 200 mL of ion-exchange resin beads that were then sealed in a glass jar for...

    journal_title:Health physics

    pub_type: 杂志文章

    doi:10.1097/00004032-199205000-00005

    authors: Clifford DA,Higgins EA

    更新日期:1992-05-01 00:00:00

  • Non-linear radionuclide transfer from the aquatic environment to fish.

    abstract::Uptake of 226Ra, 232Th, 230Th, and 228Th from water, sediment, and diet sources to bone and muscle of white suckers (Catostomus commersoni) was studied in sixteen lakes in the uranium-mining district of Ontario, Canada. Fish tissues did not increase linearly with environmental concentrations. The best relationship app...

    journal_title:Health physics

    pub_type: 杂志文章

    doi:10.1097/00004032-199709000-00007

    authors: Pyle GG,Clulow FV

    更新日期:1997-09-01 00:00:00

  • Fractional absorption of ingested uranium in humans.

    abstract::This paper provides a review and reanalysis of data relating to gastrointestinal (GI) uptake of uranium in humans. Estimates of GI uptake of uranium in adult humans have been derived from results of three controlled experimental studies involving short-term oral intake of an elevated quantity of uranium in fluids, fro...

    journal_title:Health physics

    pub_type: 杂志文章,评审

    doi:10.1097/00004032-199504000-00005

    authors: Leggett RW,Harrison JD

    更新日期:1995-04-01 00:00:00

  • Estimating past exposure to indoor radon from household glass.

    abstract::CR-39 plastic was attached to household glass objects to learn whether residual radioactivity from radon decay products could be measured and correlated with cumulative radon exposures over defined time periods. Such an approach could be used to increase the completeness of exposure data collected in epidemiologic stu...

    journal_title:Health physics

    pub_type: 杂志文章

    doi:10.1097/00004032-199304000-00005

    authors: Mahaffey JA,Parkhurst MA,James AC,Cross FT,Alavanja MC,Boice JD,Ezrine S,Henderson P,Brownson RC

    更新日期:1993-04-01 00:00:00

  • Enhanced Radioactive Material Source Security.

    abstract::Requirements for additional security measures for sealed radioactive sources have evolved since they were first implemented after the terrorist events of 11 September 2001. This paper will describe the sequence of those measures, commencing with the early orders issued by the U.S. Nuclear Regulatory Commission to the ...

    journal_title:Health physics

    pub_type: 杂志文章

    doi:10.1097/HP.0000000000000397

    authors: Klinger JG

    更新日期:2016-02-01 00:00:00

  • Dose quantities and instrumentation for measuring environmental gamma radiation during emergencies.

    abstract::The dosimetry for exposure to gamma radiation in the environment is reviewed, including the factors used to convert measurements of traceable quantities to effective dose equivalent. A value of 0.70 Sv Gy-1 is widely used to convert air kerma or absorbed dose-to-air to effective dose equivalent, but recent work shows ...

    journal_title:Health physics

    pub_type: 杂志文章

    doi:10.1097/00004032-199305000-00006

    authors: Clark MJ,Burgess PH,McClure DR

    更新日期:1993-05-01 00:00:00

  • Using a computer to manage the radiation safety and quality control activities in diagnostic radiology.

    abstract::Software has been developed to aid in the management of a radiation safety quality control program in diagnostic radiology. The core of the system is a data base of radiation safety activities. Software design goals were the prioritization, scheduling, and reporting of these activities. Computerization has helped orga...

    journal_title:Health physics

    pub_type: 杂志文章

    doi:10.1097/00004032-199201000-00015

    authors: David G,Price SC

    更新日期:1992-01-01 00:00:00

  • Light water reactor health physics.

    abstract::In this article an overview of the historical development of light water reactor health physics programs is presented. Operational health physics programs have developed and matured as experience in operating and maintaining light water reactors has been gained. Initial programs grew quickly in both size and complexit...

    journal_title:Health physics

    pub_type: 杂志文章,评审

    doi:10.1097/00004032-200506000-00011

    authors: Prince RJ,Bradley SE

    更新日期:2005-06-01 00:00:00

  • An investigation of voxel geometries for MCNP-based radiation dose calculations.

    abstract::Voxelized geometry such as those obtained from medical images is increasingly used in Monte Carlo calculations of absorbed doses. One useful application of calculated absorbed dose is the determination of fluence-to-dose conversion factors for different organs. However, confusion still exists about how such a geometry...

    journal_title:Health physics

    pub_type: 杂志文章

    doi:10.1097/01.HP.0000234039.58356.de

    authors: Zhang J,Bednarz B,Xu XG

    更新日期:2006-11-01 00:00:00

  • Development of a rapidly deployed Department of Energy emergency response element.

    abstract::The Federal Radiological Emergency Response Plan (FRERP) directs the Department of Energy (DOE) to maintain a viable, timely, and fully documented response option capable of supporting the responsible Lead Federal Agency in the event of a radiological emergency impacting any state or United States territory (e.g., CON...

    journal_title:Health physics

    pub_type: 杂志文章

    doi:10.1097/00004032-200002001-00007

    authors: Tighe RJ,Riland CA,Hopkins RC

    更新日期:2000-02-01 00:00:00

  • LIFE: a sustainable solution for developing safe, clean fusion power.

    abstract::The National Ignition Facility (NIF) at the Lawrence Livermore National Laboratory (LLNL) in California is currently in operation with the goal to demonstrate fusion energy gain for the first time in the laboratory-also referred to as "ignition." Based on these demonstration experiments, the Laser Inertial Fusion Ener...

    journal_title:Health physics

    pub_type: 杂志文章

    doi:10.1097/HP.0b013e31828d2fab

    authors: Reyes S,Dunne M,Kramer K,Anklam T,Havstad M,Mazuecos AL,Miles R,Martinez-Frias J,Deri B

    更新日期:2013-06-01 00:00:00

  • Fortification of existing rooms used for brachytherapy patients.

    abstract::Often, the radiation exposure levels around brachytherapy patient rooms exceed the limits allowed by Nuclear Regulatory Commission (NRC) regulations and National Council on Radiation Protection (NCRP) recommendations. Since a neighboring patient may be present in the radiation field from a brachytherapy patient, or pa...

    journal_title:Health physics

    pub_type: 杂志文章

    doi:10.1097/00004032-198309000-00004

    authors: Thomadsen B,van de Geijn J,Buchler D,Paliwal B

    更新日期:1983-09-01 00:00:00

  • Nonlinear properties of optical filters--implications for laser safety.

    abstract::Laser safety filter materials must be evaluated at various levels up to the maximum irradiances likely to be encountered, since the absorber may exhibit nonlinear properties. Extreme care is necessary around short-duration lasers due to extremely high peak irradiances in the beam. This is especially true for visible a...

    journal_title:Health physics

    pub_type: 杂志文章

    doi:10.1097/00004032-198607000-00007

    authors: Lyon TL,Marshall WJ

    更新日期:1986-07-01 00:00:00

  • Results of surveys at United States pulp and paper mills for the presence of scales and precipitates containing naturally occurring radioactive material (NORM).

    abstract::Field surveys were carried out at sixteen pulp and paper mills in the United States--seven kraft process, two sulfite process, and seven recycling process mills--for the presence of naturally occurring radioactive material (NORM) in precipitates and scales. NORM was detected at three of the kraft mills, one sulfite mi...

    journal_title:Health physics

    pub_type: 杂志文章

    doi:10.1097/00004032-200304000-00011

    authors: Fisher RP,Easty DB

    更新日期:2003-04-01 00:00:00

  • Adsorption of 222Rn by open-faced and diffusion-barrier canisters at different conditions of temperature and humidity.

    abstract::Open-faced and diffusion-barrier charcoal canisters were individually exposed to a fixed temperature, humidity, and radon concentration in a chamber for a period of 7 d. The radon progeny activity in the canister under study was measured every 3 h. A total of 15 runs were made for the open-faced canisters and nine run...

    journal_title:Health physics

    pub_type: 杂志文章

    doi:10.1097/00004032-199401000-00009

    authors: Luetzelschwab JW,Hastings L,Ellis SM

    更新日期:1994-01-01 00:00:00

  • Photon extremity absorbed dose and kerma conversion coefficients for calibration geometries.

    abstract::Absorbed dose and dose equivalent conversion coefficients are routinely used in personnel dosimetry programs. These conversion coefficients can be applied to particle fluences or to measured air kerma values to determine appropriate operational monitoring quantities such as the ambient dose equivalent or personal dose...

    journal_title:Health physics

    pub_type: 杂志文章

    doi:10.1097/01.HP.0000243165.43316.78

    authors: Veinot KG,Hertel NE

    更新日期:2007-02-01 00:00:00

  • Assessing the applicability of FISH-based prematurely condensed dicentric chromosome assay in triage biodosimetry.

    abstract::The dicentric chromosome assay (DCA) has been regarded as the gold standard of radiation biodosimetry. The assay, however, requires a 2-d peripheral blood lymphocyte culture before starting metaphase chromosome analyses to estimate biological doses. Other biological assays also have drawbacks with respect to the time ...

    journal_title:Health physics

    pub_type: 杂志文章

    doi:10.1097/HP.0000000000000182

    authors: Suto Y,Gotoh T,Noda T,Akiyama M,Owaki M,Darroudi F,Hirai M

    更新日期:2015-03-01 00:00:00

  • Mixing in a square and a rectangular duct regarding selection of locations for extractive sampling of gaseous contaminants.

    abstract::Tests were conducted to characterize the uniformity of velocity and tracer gas profiles in a square and a rectangular duct with respect to defining the suitability of locations for single point sampling of gaseous contaminants. Several configurations, such as a straight duct with unidirectional flow at the entrance se...

    journal_title:Health physics

    pub_type: 杂志文章

    doi:10.1097/01.HP.0000203325.62672.39

    authors: Seo Y,McFarland AR,Ortiz CA,O'Neal DL

    更新日期:2006-07-01 00:00:00

  • Imaging radiation induced muscular necrosis with antimyosin-scintigraphy and computed tomography.

    abstract::Radiations accidents involving high exposures require accurate assessment of radiation dose for correct surgical or medical management. Techniques involving computed tomography and antimyosin-antibody scintigraphy were evaluated in an experimental model of acute localized irradiation overexposure to 192Ir. Ten rabbits...

    journal_title:Health physics

    pub_type: 杂志文章

    doi:10.1097/00004032-200001000-00009

    authors: Albérini JL,Lefaix JL,Bansard JY,Bourguet P

    更新日期:2000-01-01 00:00:00

  • Investigation of atmospheric, mechanical and other pressure effects influencing the levels of radon and radon progeny in buildings.

    abstract::Real-time data measurement and analysis have identified a number of influences affecting the variability and accumulation of radon and its progeny in indoor air. Observed cycles in radon concentrations were shown to be related to the influence of air-conditioning and water-heated central heating systems. The cyclical ...

    journal_title:Health physics

    pub_type: 杂志文章

    doi:10.1097/00004032-199911000-00010

    authors: Marley F

    更新日期:1999-11-01 00:00:00

  • Modeling the resuspension of radionuclides in Ukrainian regions impacted by Chernobyl fallout.

    abstract::Following the 1986 Chernobyl event, large amounts of radioactive materials were deposited in nearby areas. Concentrations of various radionuclides were measured in air and surface soil. To study the resuspension of radioactive particulate, three different exposure situations were developed on the basis of the collecte...

    journal_title:Health physics

    pub_type: 杂志文章

    doi:10.1097/00004032-199701000-00010

    authors: Nair SK,Miller CW,Thiessen KM,Garger EK,Hoffman FO

    更新日期:1997-01-01 00:00:00

  • A Monte Carlo approach to assessing 147Pm in the liver of the adult phantom.

    abstract::A low-background phoswich detector is used to detect small amounts of 147Pm--a pure beta-emitting nuclide--present in the liver of an occupational worker. The assessment was based on the measurement of bremsstrahlung radiation produced by the beta particles in the tissue. Computer programs based on Monte Carlo techniq...

    journal_title:Health physics

    pub_type: 杂志文章

    doi:10.1097/00004032-199306000-00010

    authors: Bhati S

    更新日期:1993-06-01 00:00:00

  • A Radon Background-subtraction Algorithm for Electronic Personal Dosimeters.

    abstract::Many first responders are outfitted with electronic personal dosimeters to recognize and be alerted to radiological hazards during their response operations. These dosimeters provide invaluable measurement data for force protection, allowing the first responder to assess a response situation and take protective measur...

    journal_title:Health physics

    pub_type: 杂志文章

    doi:10.1097/HP.0000000000001178

    authors: Fabian R,Bell J,Brandl A

    更新日期:2020-08-01 00:00:00

  • 239Pu metabolism in newborn and weanling pigs.

    abstract::Newborn (1-2 days old) and weanling (6 wk old) miniature pigs were injected intravenously with 239Pu citrate. Animals from each age group were killed at intervals over a 28-day period to obtain distribution and retention data. The most notable difference between the two age groups was in hepatic deposition and retenti...

    journal_title:Health physics

    pub_type: 杂志文章

    doi:10.1097/00004032-198305000-00007

    authors: McClanahan BJ,Mahlum DD

    更新日期:1983-05-01 00:00:00

  • Chernobyl and Goiânia lessons for responding to radiological terrorism.

    abstract::The deployment of a radiological dispersal device (RDD) is likely to result in relatively low radiation exposure of the targeted population, insufficient to cause a severe radiation detriment. Nevertheless, due to atmospheric dispersion of the radioactive material, an urban area equaling several city blocks could be a...

    journal_title:Health physics

    pub_type: 杂志文章

    doi:10.1097/01.hp.0000178545.02726.21

    authors: Steinhausler F

    更新日期:2005-11-01 00:00:00

  • Determination of Uranium Series Activity Before Secular Equilibrium Is Established.

    abstract::Timely achievement of uranium series' secular equilibrium is not always feasible. Our objective is to mathematically justify methods for early uranium series gamma spectroscopy measurements that can accurately predict naturally occurring radioactive material equilibrium activities long before equilibrium is establishe...

    journal_title:Health physics

    pub_type: 杂志文章

    doi:10.1097/HP.0000000000001073

    authors: Wilson CA 4th,Matthews KL 2nd,Hamideh AM,Wang WH

    更新日期:2019-10-01 00:00:00