Pipeline embolization device thrombosis induced peri-construct collateral channels.

Abstract:

:More than half a decade of experience and follow-up has now been accumulated with regard to flow diversion as a treatment for intracranial aneurysms; however, many uncertainties, such as the nature of aneurysmal remnants and the meaning of non-regressed, non-perfused aneurysmal masses, are still unknown. Here we discuss a 22-year-old man who presented with a grade 1 subarachnoid hemorrhage secondary to a dissecting right anterior cerebral artery aneurysm who was subsequently treated with a Pipeline Embolization Device construct. After ceasing dual antiplatelet therapy himself, he was found on MRI to have an area of increased aneurysmal remnant reperfusion. This was found to connect to multiple channels which reconstituted flow within the distal construct on angiography. The central area of construct thrombosis could not be visualized on MRI. The finding suggests that non-opacified aneurysmal remnants that have not regressed are biologically active and raises concerns regarding using MRI for long term follow-up.

journal_name

J Neurointerv Surg

authors

Chiu AH,Marotta TR

doi

10.1136/neurintsurg-2015-012093.rep

subject

Has Abstract

pub_date

2016-11-01 00:00:00

pages

e47

issue

11

eissn

1759-8478

issn

1759-8486

pii

neurintsurg-2015-012093.rep

journal_volume

8

pub_type

杂志文章
  • Inter-rater reliability of published flow diversion occlusion scales.

    abstract:BACKGROUND:With increasing use of flow-diverting stents for the treatment of intracranial aneurysms, standardized methods and a common language to evaluate angiographic outcomes are needed. Multiple grading scales have been developed for this purpose but none has been widely adopted. OBJECTIVE:To analyze these scales ...

    journal_title:Journal of neurointerventional surgery

    pub_type: 杂志文章

    doi:10.1136/neurintsurg-2015-012193

    authors: Mazur MD,Taussky P,Shah LM,Winegar B,Park MS

    更新日期:2016-12-01 00:00:00

  • Risk of acute kidney injury associated with neuroimaging obtained during triage and treatment of patients with acute ischemic stroke symptoms.

    abstract:BACKGROUND:Combining non-contrast CT (NCCT), CT angiography (CTA), and CT perfusion (CTP) imaging (referred to as a CT stroke study, CTSS) provides a rapid evaluation of the cerebrovascular axis during acute ischemic stroke. Iodinated contrast-enhanced CT imaging is not without risk, which includes renal injury. If a p...

    journal_title:Journal of neurointerventional surgery

    pub_type: 杂志文章

    doi:10.1136/neurintsurg-2015-012118

    authors: Hall SL,Munich SA,Cress MC,Rangel-Castilla L,Levy EI,Snyder KV,Siddiqui AH

    更新日期:2016-12-01 00:00:00

  • Venous sinus stenting for idiopathic intracranial hypertension: a review of the literature.

    abstract::Idiopathic intracranial hypertension (IIH) is characterized by headache, papilledema, visual field changes and tinnitus with elevated cerebral spinal fluid opening pressures on lumbar puncture. Left untreated, this condition can lead to permanent visual loss. Previous treatment modalities include medical management, t...

    journal_title:Journal of neurointerventional surgery

    pub_type: 杂志文章,评审

    doi:10.1136/neurintsurg-2012-010468

    authors: Puffer RC,Mustafa W,Lanzino G

    更新日期:2013-09-01 00:00:00

  • Prediction of death after endovascular thrombectomy in the extended window: a secondary analysis of DEFUSE 3 ".

    abstract:BACKGROUND:The Endovascular Therapy Following Imaging Evaluation for Ischemic Stroke 3 (DEFUSE 3) clinical trial assessed the use of endovascular thrombectomy (EVT) during the period 6-16 hours after last normal in selected patients. This is a secondary cohort analysis of the DEFUSE 3 data assessing potential predictiv...

    journal_title:Journal of neurointerventional surgery

    pub_type: 杂志文章

    doi:10.1136/neurintsurg-2020-016548

    authors: Taussky P,Agnoletto G,Grandhi R,Alexander MD,Wong KH,Albers GW,de Havenon A

    更新日期:2020-10-19 00:00:00

  • A novel approach to the management of carotid blowout syndrome: the use of thrombin in a case of failed covered stenting.

    abstract::Acute hemorrhage relating to an expanding pseudoaneurysm of the carotid artery is referred to as carotid blowout syndrome (CBS). CBS is associated with a high morbidity and mortality. We describe the case of a patient who presented with dysphagia and a pulsatile mass in the neck. Imaging revealed a pseudoaneurysm orig...

    journal_title:Journal of neurointerventional surgery

    pub_type: 杂志文章

    doi:10.1136/neurintsurg-2015-012121.rep

    authors: Sablani N,Jain G,Hasan MM,Sivakumar K,Feuerwerker S,Arcot K,Farkas J

    更新日期:2016-12-01 00:00:00

  • Inflammatory changes in the aneurysm wall: a review.

    abstract::Rupture of a saccular intracranial artery aneurysm (IA) causes subarachnoid hemorrhage, a significant cause of stroke and death. The current treatment options, endovascular coiling and clipping, are invasive and somewhat risky. Since only some IAs rupture, those IAs at risk for rupture should be identified. However, t...

    journal_title:Journal of neurointerventional surgery

    pub_type: 杂志文章,评审

    doi:10.1136/jnis.2009.002055.rep

    authors: Tulamo R,Frösen J,Hernesniemi J,Niemelä M

    更新日期:2018-07-01 00:00:00

  • Infectious intracranial aneurysms: a systematic review of epidemiology, management, and outcomes.

    abstract::Infectious intracranial aneurysms (IIAs) are a rare cerebrovascular complication of systemic infections induced by microbial infiltration and degradation of the arterial vessel wall. Studies on the epidemiology and management of IIAs are limited to case reports and retrospective single-center studies, and report a lar...

    journal_title:Journal of neurointerventional surgery

    pub_type: 杂志文章,评审

    doi:10.1136/neurintsurg-2017-013603

    authors: Alawieh A,Chaudry MI,Turner RD,Turk AS,Spiotta AM

    更新日期:2018-07-01 00:00:00

  • Per-pass analysis of acute ischemic stroke clots: impact of stroke etiology on extracted clot area and histological composition.

    abstract:BACKGROUND:Initial studies investigating correlations between stroke etiology and clot composition are conflicting and do not account for clot size as determined by area. Radiological studies have shown that cardioembolic strokes are associated with shorter clot lengths and lower clot burden than non-cardioembolic clot...

    journal_title:Journal of neurointerventional surgery

    pub_type: 杂志文章

    doi:10.1136/neurintsurg-2020-016966

    authors: Fitzgerald S,Rossi R,Mereuta OM,Jabrah D,Okolo A,Douglas A,Molina Gil S,Pandit A,McCarthy R,Gilvarry M,Dunker D,Nordanstig A,Ceder E,Redfors P,Jood K,Dehlfors N,Magoufis G,Tsivgoulis G,Brinjikji W,Kallmes DF,O'Har

    更新日期:2020-12-09 00:00:00

  • Intracranial bailout stenting with the Acclino (Flex) Stent/NeuroSpeed Balloon Catheter after failed thrombectomy in acute ischemic stroke: a multicenter experience.

    abstract:BACKGROUND AND PURPOSE:To report on the feasibility, safety, and outcome of acute intracranial stenting (ICS) with the Acclino (Flex) Stent and NeuroSpeed Balloon Catheter in cases of failed mechanical thrombectomy (MT) for acute ischemic stroke (AIS). METHODS:We retrospectively reviewed the data of patients treated w...

    journal_title:Journal of neurointerventional surgery

    pub_type: 杂志文章,多中心研究

    doi:10.1136/neurintsurg-2019-014957

    authors: Stracke CP,Meyer L,Fiehler J,Leischner H,Bester M,Buhk JH,Thomalla G,Krause LU,Lowens S,Rothaupt J,Chapot R,Hanning U

    更新日期:2020-01-01 00:00:00

  • Endovascular retrieval of dental needle retained in the internal carotid artery.

    abstract::Intravascular foreign bodies are a known complication of medical and dental procedures. Dental anesthetic needles may be broken off and retained in the oropharynx. These needles have occasionally been reported to migrate through the oral mucosa in to deeper structures. Here we present the case of a 57-year-old man who...

    journal_title:Journal of neurointerventional surgery

    pub_type: 杂志文章

    doi:10.1136/neurintsurg-2016-012771.rep

    authors: Moore K,Khan NR,Michael LM,Arthur AS,Hoit D

    更新日期:2017-07-01 00:00:00

  • Use of a pressure sensing sheath: comparison with standard means of blood pressure monitoring in catheterization procedures.

    abstract:PURPOSE:Monitoring of blood pressure (BP) during procedures is variable, depending on multiple factors. Common methods include sphygmomanometer (BP cuff), separate radial artery catheterization, and side port monitoring of an indwelling sheath. Each means of monitoring has disadvantages, including time consumption, add...

    journal_title:Journal of neurointerventional surgery

    pub_type: 杂志文章

    doi:10.1136/neurintsurg-2016-012536

    authors: Purdy PD,South C,Klucznik RP,Liu KC,Novakovic RL,Puri AS,Pride GL,Aagaard-Kienitz B,Ray A,Elliott AC

    更新日期:2017-08-01 00:00:00

  • Incidence and morbidity of craniocervical arterial dissections in atraumatic subarachnoid hemorrhage patients who underwent aneurysmal repair.

    abstract:BACKGROUND:No studies have assessed the incidence of craniocervical arterial dissections (CCADs) and its association to mortality in hospitalized patients with a primary diagnosis of atraumatic subarachnoid hemorrhage (SAH) requiring aneurysmal repair. We hypothesize that the incidence of CCADs in these patients has in...

    journal_title:Journal of neurointerventional surgery

    pub_type: 杂志文章

    doi:10.1136/neurintsurg-2014-011324

    authors: Carr K,Rincon F,Maltenfort M,Birnbaum L,Dengler B,Rodriguez M,Seifi A

    更新日期:2015-10-01 00:00:00

  • Early results of the Axium MicroFX for Endovascular Repair of IntraCranial Aneurysm (AMERICA) study: a multicenter prospective observational registry.

    abstract:BACKGROUND:Axium MicroFX coils contain polymer (polyglycolic/polylactic acid, PGLA) microfilaments designed to significantly impact intra-aneurysmal flow and to encourage aneurysm thrombosis. To provide preliminary evaluation of the safety and suggested efficacy of the MicroFX design, we performed a multicenter prospec...

    journal_title:Journal of neurointerventional surgery

    pub_type: 杂志文章,多中心研究

    doi:10.1136/neurintsurg-2013-010887

    authors: Fargen KM,Blackburn S,Carpenter JS,Jabbour P,Mack WJ,Rai AT,Siddiqui AH,Turner RD,Mocco J

    更新日期:2014-09-01 00:00:00

  • Endovascular stroke therapy may be safe in patients with elevated international normalized ratio.

    abstract:INTRODUCTION:Endovascular therapy in acute ischemic stroke is safe and efficient. However, patients receiving oral anticoagulation were excluded in the larger trials. OBJECTIVE:To analyze the safety of endovascular therapy in patients with acute ischemic stroke and elevated international normalized ratio (INR) values....

    journal_title:Journal of neurointerventional surgery

    pub_type: 杂志文章

    doi:10.1136/neurintsurg-2016-012757

    authors: Mundiyanapurath S,Tillmann A,Möhlenbruch MA,Bendszus M,Ringleb PA

    更新日期:2017-12-01 00:00:00

  • Novel aneurysm neck reconstruction device: initial experience in an experimental preclinical bifurcation aneurysm model.

    abstract:INTRODUCTION:Treatment of wide-necked bifurcation aneurysms often poses procedural and long-term outcome challenges. The initial preclinical experience with the Pulsar Vascular Aneurysm Neck Reconstruction Device (PVANRD) in a canine bifurcation model is described. METHODS:Experimental bifurcation vein pouch aneurysms...

    journal_title:Journal of neurointerventional surgery

    pub_type: 杂志文章

    doi:10.1136/neurintsurg-2012-010312

    authors: Turk A,Turner RD,Tateshima S,Fiorella D,Jang KS,Chaudry I,Kelly M

    更新日期:2013-07-01 00:00:00

  • Early detachment of the Solitaire stent during thrombectomy retrieval: an in vitro investigation.

    abstract:OBJECTIVE:To elucidate the early detachment of the Solitaire stent during mechanical thrombectomy, we tested the stent in vitro under various conditions and evaluated with microscopy. METHODS:A total of five stents were tested. Using a dynamic mechanical analysis machine, we calculated the tensile force needed for sep...

    journal_title:Journal of neurointerventional surgery

    pub_type: 杂志文章

    doi:10.1136/neurintsurg-2013-010942

    authors: Kwon HJ,Chueh JY,Puri AS,Koh HS

    更新日期:2015-02-01 00:00:00

  • Micro Vascular Plug (MVP)-assisted vessel occlusion in neurovascular pathologies: technical results and initial clinical experience.

    abstract:BACKGROUND:Deconstructive approaches may be necessary to treat a variety of neurovascular pathologies. Recently, a new device has become available for endovascular arterial occlusion that may have unique applications in neurovascular disease. The Micro Vascular Plug (MVP, Reverse Medical, Irvine, California, USA) has b...

    journal_title:Journal of neurointerventional surgery

    pub_type: 杂志文章

    doi:10.1136/neurintsurg-2014-011306

    authors: Beaty NB,Jindal G,Gandhi D

    更新日期:2015-10-01 00:00:00

  • Treatment of recurrent intracranial aneurysms with the Pipeline Embolization Device.

    abstract:BACKGROUND:The treatment of recurrent aneurysms after previous surgery or embolization is challenging. Little is known regarding the use of the Pipeline Embolization Device (PED) for recurrent aneurysms. OBJECTIVE:To analyze the safety and results of PED therapy for recurrent aneurysms. METHODS:Fifteen patients with ...

    journal_title:Journal of neurointerventional surgery

    pub_type: 杂志文章

    doi:10.1136/neurintsurg-2012-010612

    authors: Chalouhi N,Chitale R,Starke RM,Jabbour P,Tjoumakaris S,Dumont AS,Rosenwasser RH,Gonzalez LF

    更新日期:2014-01-01 00:00:00

  • The modified 'no touch' technique in the antegrade endovascular approach for left common carotid artery ostial stenosis stenting.

    abstract:BACKGROUND:Open surgery and the retrograde endovascular approach via the distal left common carotid artery (LCCA) have some limitations in LCCA ostial stenosis treatment. The 'no touch' technique used in the renal artery was modified for this situation. METHODS:Fifteen selective LCCA stenosis patients were treated by ...

    journal_title:Journal of neurointerventional surgery

    pub_type: 杂志文章

    doi:10.1136/neurintsurg-2016-012544

    authors: Tang X,Long WA,Hu C,Tang F,Wang Q,Li L

    更新日期:2017-02-01 00:00:00

  • Picture-to-puncture time in acute stroke endovascular intervention: are we getting faster?

    abstract:BACKGROUND:In acute stroke management, time efficiency in the continuum of patient management is critical. We aimed to determine if implementation of system improvements at our institution translated to reduced picture-to-puncture (P2P) times over a 6-year period. METHODS:We conducted a single-center retrospective ana...

    journal_title:Journal of neurointerventional surgery

    pub_type: 杂志文章

    doi:10.1136/neurintsurg-2014-011177

    authors: van Heerden J,Yan B,Churilov L,Dowling RJ,Mitchell PJ

    更新日期:2015-08-01 00:00:00

  • The value of protective head cap and glasses in neurointerventional radiology.

    abstract:BACKGROUND:Protection of the head and eyes of the neurointerventional radiologist is a growing concern, especially after recent reports on the incidence of brain cancer among these personnel, and the revision of dose limits to the eye lens. The goal of this study was to determine typical occupational dose levels and to...

    journal_title:Journal of neurointerventional surgery

    pub_type: 杂志文章

    doi:10.1136/neurintsurg-2015-011703

    authors: Sans Merce M,Korchi AM,Kobzeva L,Damet J,Erceg G,Marcos Gonzalez A,Lovblad KO,Mendes Pereira V

    更新日期:2016-07-01 00:00:00

  • Quantification of speed-up and accuracy of multi-CPU computational flow dynamics simulations of hemodynamics in a posterior communicating artery aneurysm of complex geometry.

    abstract:BACKGROUND:Towards the translation of computational fluid dynamics (CFD) techniques into the clinical workflow, performance increases achieved with parallel multi-central processing unit (CPU) pulsatile CFD simulations in a patient-derived model of a bilobed posterior communicating artery aneurysm were evaluated while ...

    journal_title:Journal of neurointerventional surgery

    pub_type: 杂志文章

    doi:10.1136/neurintsurg-2012-010586

    authors: Karmonik C,Yen C,Gabriel E,Partovi S,Horner M,Zhang YJ,Klucznik RP,Diaz O,Grossman RG

    更新日期:2013-11-01 00:00:00

  • Relationship of white matter lesion severity with early and late outcomes after mechanical thrombectomy for large vessel stroke.

    abstract:BACKGROUND:White matter lesions (WML) are associated with poor outcome after mechanical thrombectomy (MT) for large vessel stroke; the reasons are uncertain. To elucidate this issue we sought to determine the association of WML with multiple early and late outcome measures after MT. METHODS:We retrospectively analyzed...

    journal_title:Journal of neurointerventional surgery

    pub_type: 杂志文章

    doi:10.1136/neurintsurg-2020-015940

    authors: Albo Z,Marino J,Nagy M,Jayaraman DK,Azeem MU,Puri AS,Henninger N

    更新日期:2021-01-01 00:00:00

  • The bihemispheric posterior interior cerebellar artery: anatomic variations and clinical relevance in 11 cases.

    abstract:PURPOSE:Although the anatomic course of the posterior interior cerebellar artery (PICA) is variable, it is thought to be very rare for the artery to cross midline, with an estimated incidence of 0.1%. Bihemispheric PICA crosses midline and typically serves both PICA territories. METHODS:We present 11 cases of bihemisp...

    journal_title:Journal of neurointerventional surgery

    pub_type: 杂志文章

    doi:10.1136/neurintsurg-2012-010527

    authors: Carlson AP,Alaraj A,Dashti R,Aletich VA

    更新日期:2013-11-01 00:00:00

  • Transfundal stent placement for treatment of complex basilar tip aneurysm: technical note.

    abstract::We describe a case where a complex unruptured basilar tip aneurysm was treated with a unique method of stent-assisted coil embolization. The aneurysm was considered to have a complex anatomy since both the left posterior cerebral artery and left superior cerebellar artery originated from the dome of the aneurysm. Also...

    journal_title:Journal of neurointerventional surgery

    pub_type: 杂志文章

    doi:10.1136/neurintsurg-2014-011288.rep

    authors: Vasquez C,Hubbard M,Jagadeesan BD,Tummala RP

    更新日期:2015-10-01 00:00:00

  • Use of the pCONus HPC as an adjunct to coil occlusion of acutely ruptured aneurysms: early clinical experience using single antiplatelet therapy.

    abstract:BACKGROUND:Coil occlusion has become the standard treatment for many ruptured aneurysms. However, specific aneurysm structures pose technical difficulties and may require the use of adjunctive neck-bridging devices, which necessitate the use of dual antiplatelet therapy. The hydrophilic polymer coating (pHPC, phenox) i...

    journal_title:Journal of neurointerventional surgery

    pub_type: 杂志文章

    doi:10.1136/neurintsurg-2019-015746

    authors: Aguilar Perez M,AlMatter M,Hellstern V,Wendl C,Ganslandt O,Bäzner H,Henkes H

    更新日期:2020-09-01 00:00:00

  • Reversible cerebral vasoconstriction syndromes presenting with subarachnoid hemorrhage: a case series.

    abstract:BACKGROUND AND PURPOSE:Reversible cerebral vasoconstriction syndromes (RCVS) represent a heterogeneous group of cerebrovascular disease characterized by acute presentations and transient segmental narrowing of the distal intracranial arteries. A series of patients with RCVS were studied to better understand the clinica...

    journal_title:Journal of neurointerventional surgery

    pub_type: 杂志文章

    doi:10.1136/jnis.2010.004242

    authors: Ansari SA,Rath TJ,Gandhi D

    更新日期:2011-09-01 00:00:00

  • The impact of timing on outcomes of carotid artery stenting in recently symptomatic patients.

    abstract:OBJECTIVES:We sought to determine whether the timing of carotid artery stenting (CAS) affects peri-procedural outcomes in recently symptomatic patients. BACKGROUND:Early carotid endarterectomy following a stroke lowers the risk of recurrent ischemic events but has been associated with an increased risk of intracerebra...

    journal_title:Journal of neurointerventional surgery

    pub_type: 杂志文章

    doi:10.1136/jnis.2009.000901

    authors: Lin R,Mazighi M,Yadav J,Abou-Chebl A

    更新日期:2010-03-01 00:00:00

  • Onyx embolization of an extensive mandibular arteriovenous malformation via a dual lumen balloon catheter: a technical case report.

    abstract:SUMMARY:The first known use of Onyx delivered via a dual lumen balloon catheter is reported. A mandibular arteriovenous malformation was successfully embolized with Onyx via an Ascent balloon catheter. CASE PRESENTATION:A teenage girl presented with facial deformity and episodes of oral bleeding. Angiogram showed an e...

    journal_title:Journal of neurointerventional surgery

    pub_type: 杂志文章

    doi:10.1136/neurintsurg-2011-010179

    authors: Fifi J,Niimi Y,Berenstein A

    更新日期:2013-03-01 00:00:00

  • Stentrievers versus other endovascular treatment methods for acute stroke: comparison of procedural results and their relationship to outcomes.

    abstract:BACKGROUND AND PURPOSE:The use of stentrievers (ST) is rapidly growing due to several potential benefits over other available treatments. ST potentially restore flow before clot retrieval and reduce procedural time. We aimed to study the impact of these potential benefits. METHODS:Patients with acute stroke treated wi...

    journal_title:Journal of neurointerventional surgery

    pub_type: 杂志文章,多中心研究

    doi:10.1136/neurintsurg-2013-010748

    authors: Ribo M,Molina CA,Jankowitz B,Tomasello A,Zaidi S,Jumaa M,Coscojuela P,Oakley J,Alvarez-Sabín J,Jovin T

    更新日期:2014-05-01 00:00:00