Abstract:
BACKGROUND:Advanced techniques of electroanatomical mapping efficiently guide ventricular tachycardia (VT) ablation strategies; in this context, the adjunctive value of combining activation mapping (AMap) to improve accuracy has not been elucidated. OBJECTIVE:To investigate whether conventional AMap further contributes to the identification of critical sites of VT reentry and whether this translates into a more effective ablation outcome in a cohort of patients undergoing VT ablation. METHODS:We prospectively enrolled 126 patients (mean age 65.3 ± 10.5 years; left ventricular ejection fraction 33.3% ± 7.2%) with ischemic (n = 89) or idiopathic (n = 37) dilated cardiomyopathy undergoing endocardial (n = 105) or endo-epicardial (n = 21) electroanatomical mapping and ablation. A substrate-guided strategy targeting surrogate markers of reentry was accomplished in all patients, but the feasibility and efficacy of AMap was preliminarily assessed for all induced VTs focusing on early VT suppression obtained during radiofrequency delivery. VT-free survival was assessed by ICD interrogation. RESULTS:AMap successfully guided ablation in 62 of 104 (59.6%) patients with inducible VT(s). At 1 year, 6 of 126 (4.8%) patients died; VT recurred in 28 of 126 (22.2%) patients. No significant difference in VT recurrence rate was observed between patients in whom AMap proved effective versus those in whom substrate-guided ablation was not corroborated by AMap (16 of 62 [25.8%] vs 12 of 64 [18.8%]; log-rank test, P = .3). CONCLUSIONS:Our findings support the efficacy of a substrate-guided strategy targeting specific markers of arrhythmogenicity identified during sinus rhythm. AMap proves highly efficient acutely but does not improve overall VT-free survival, suggesting that in patients with advanced cardiac disease, life-threatening arrhythmias can be successfully treated by ablation in sinus rhythm, thus limiting procedural risks.
journal_name
Heart Rhythmjournal_title
Heart rhythmauthors
Carbucicchio C,Ahmad Raja N,Di Biase L,Volpe V,Dello Russo A,Trivedi C,Bartoletti S,Zucchetti M,Casella M,Russo E,Santangeli P,Moltrasio M,Tundo F,Fassini G,Natale A,Tondo Cdoi
10.1016/j.hrthm.2013.09.059subject
Has Abstractpub_date
2013-12-01 00:00:00pages
1850-8issue
12eissn
1547-5271issn
1556-3871pii
S1547-5271(13)01069-2journal_volume
10pub_type
杂志文章相关文献
HEART RHYTHM文献大全abstract:BACKGROUND:Early detection of cardiac involvement in sarcoidosis is difficult but essential to achieve optimal treatment. Signal-averaged electrocardiography (SAECG) can detect subtle cardiac electrical abnormalities termed late potentials (LPs) and would be useful for the early diagnosis of cardiac involvement. OBJEC...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2018.03.013
更新日期:2018-06-01 00:00:00
abstract:BACKGROUND:Areas of conduction delay (CD) or conduction block (CB) are associated with higher recurrence rates after ablation therapy for atrial fibrillation (AF). OBJECTIVE:Thus far, there are no reports on the quantification of the extensiveness of CD and CB at the pulmonary vein area (PVA) and their clinical releva...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2018.10.027
更新日期:2019-04-01 00:00:00
abstract:BACKGROUND:Patients with atrial fibrillation (AF) experience an increased risk of heart failure (HF). However, data are lacking on current trends in the risk of HF after AF. OBJECTIVE:The purpose of this study was to describe the temporal trends in HF occurrence after AF in a community cohort of patients with incident...
journal_title:Heart rhythm
pub_type: 杂志文章,多中心研究
doi:10.1016/j.hrthm.2017.01.031
更新日期:2017-06-01 00:00:00
abstract:BACKGROUND:Only a few studies on the cephalic vein cutdown technique for pacemaker lead implantation in children weighing ≤10 kg have been reported even though the procedure is widely accepted in adults. OBJECTIVE:The purpose of this study was to prove that cephalic vein cutdown for pacemaker lead implantation is a re...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2015.04.025
更新日期:2015-08-01 00:00:00
abstract:BACKGROUND:With the increasing use of implantable cardioverter-defibrillators (ICDs), device complications are becoming more common. Fungal-related ICD infections have rarely been reported, and little is known about the presentation, prevalence, and treatment options for these morbid infections. OBJECTIVES:The purpose...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2006.04.012
更新日期:2006-08-01 00:00:00
abstract:BACKGROUND:A considerable rate of atrial fibrillation (AF) recurrence is one of the major limitations of pulmonary vein isolation (PVI). Although endothelin-1 (ET-1) is involved in atrial remodeling, it is unknown whether plasma ET-1 level before PVI can be used as a predictive factor for AF recurrence. OBJECTIVE:The ...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2009.02.027
更新日期:2009-06-01 00:00:00
abstract:BACKGROUND:Epicardial pacing increases risk of ventricular tachycardia (VT) in patients with ischemic cardiomyopathy (ICM) when pacing in proximity to scar. Endocardial pacing may be less arrhythmogenic as it preserves the physiological sequences of activation and repolarization. OBJECTIVE:The purpose of this study wa...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2020.03.021
更新日期:2020-08-01 00:00:00
abstract:BACKGROUND:Limited data exist on cryoablation of atrial fibrillation (Cryo-AF) using the newly available third-generation (Arctic Front Advance-Short Tip [AFA-ST]) cryoballoon. OBJECTIVE:In this multicenter study, we evaluated the safety and efficacy of Cryo-AF using the AFA-ST vs the second-generation (Arctic Front A...
journal_title:Heart rhythm
pub_type: 杂志文章,多中心研究
doi:10.1016/j.hrthm.2016.08.011
更新日期:2016-12-01 00:00:00
abstract:BACKGROUND:Catheter ablation for polymorphic ventricular tachycardia and ventricular fibrillation (PMVT/VF) may target triggering premature ventricular contractions (PVCs). Targeting ventricular scar has also been suggested, but data are limited. OBJECTIVE:The purpose of this study was to characterize the electrophysi...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2019.01.032
更新日期:2019-07-01 00:00:00
abstract:BACKGROUND:Gaps in the roof line have been ascribed to epicardial conduction using the septopulmonary bundle. OBJECTIVES:We sought to evaluate the frequency of septopulmonary bundle bypass during roof line ablation, to describe anatomical conditions favoring this epicardial gap, and to propose an alternative strategy ...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2020.11.008
更新日期:2020-11-11 00:00:00
abstract:BACKGROUND:Little is known about the role of left atrial appendage closure using the Watchman device (Boston Scientific) in patients who are at very high risk for stroke. OBJECTIVE:The purpose of this study was to assess the role of Watchman in patients with CHA2DS2-VASc ≥5. METHODS:All patients undergoing procedures...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2019.07.011
更新日期:2020-01-01 00:00:00
abstract:OBJECTIVES:To evaluate the feasibility and outcome of ablation to transect the anterior left atrium (LA) in patients with atrial fibrillation (AF). BACKGROUND:While the Maze procedure is effective in maintaining sinus rhythm in patients with AF, it is associated with significant morbidity. This prospective clinical st...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2004.03.072
更新日期:2004-07-01 00:00:00
abstract:BACKGROUND:Complex fractionated atrial electrograms (CFAEs) and regions of high dominant frequency (DF) both may identify sites critical to the maintenance of atrial fibrillation (AF). CFAEs may be defined by either (1) complex multicomponent electrograms (EGMs) and/or continuous electrical activity (multicomponent/con...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2011.05.021
更新日期:2011-11-01 00:00:00
abstract:OBJECTIVES:The purpose of this study was to determine if there is a difference in commercially available biphasic waveforms. BACKGROUND:Although the superiority of biphasic over monophasic waveforms for external cardioversion of atrial fibrillation (AF) is established, the relative efficacy of available biphasic wavef...
journal_title:Heart rhythm
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1016/j.hrthm.2004.12.024
更新日期:2005-04-01 00:00:00
abstract:BACKGROUND:QRS transition zone is related to the electrical axis of the heart in the horizontal plane and is easily determined from the precordial leads of a standard 12-lead ECG. However, whether delayed QRS transition, or clockwise rotation of the heart, carries prognostic implications and predicts sudden cardiac dea...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2014.08.014
更新日期:2014-12-01 00:00:00
abstract:BACKGROUND:Regular alcohol intake is an important modifiable risk factor associated with atrial fibrillation (AF) and left atrial (LA) dilation. OBJECTIVE:The purpose of this study was to determine the impact of different degrees of alcohol consumption on atrial remodeling using high-density electroanatomic mapping. ...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2018.10.041
更新日期:2019-02-01 00:00:00
abstract:BACKGROUND:An accurate estimate of the incidence of sudden cardiac arrest (SCA) in high school student athletes is needed to guide prevention strategies. OBJECTIVE:To prospectively investigate SCA rates in high school student athletes vs student nonathletes. METHODS:A prospective observational study of 2149 US high s...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2014.04.017
更新日期:2014-07-01 00:00:00
abstract:BACKGROUND:Loss-of-function mutations in SCN5A are associated in ∼20% of Brugada syndrome (BrS) patients. Copy number variations (CNVs) have been shown to be associated with several inherited arrhythmia syndromes. OBJECTIVE:The purpose of this study was to investigate SCN5A CNVs among BrS probands. METHODS:The study ...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2018.03.033
更新日期:2018-08-01 00:00:00
abstract:BACKGROUND:Nontransvenous (NTV) implantable cardioverter-defibrillator (ICD) systems with pericardial and/or subcutaneous coils are used in select pediatric and congenital heart disease patients who are not candidates for transvenous ICD leads. Outcomes with these hybrid configurations are not well understood. OBJECTI...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2009.10.014
更新日期:2010-01-01 00:00:00
abstract:BACKGROUND:Acute success rates of accessory pathway ablation for Wolff-Parkinson-White (WPW) syndrome can exceed 95%, with rare failures attributed to anatomically complex epicardial connections. Right atrial appendage to right ventricle pathways have been reported, but their left-sided counterparts have only recently ...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2010.08.013
更新日期:2010-12-01 00:00:00
abstract:BACKGROUND:Complex fractionated electrograms (CFAEs) detected during substrate mapping for atrial fibrillation (AF) reflect etiologies that are difficult to separate. Without knowledge of local refractoriness and activation sequence, CFAEs may represent rapid localized activity, disorganized wave collisions, or far-fie...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2010.10.020
更新日期:2011-02-01 00:00:00
abstract:BACKGROUND:Atrial fibrillation (AF) ablation is increasingly used in patients with reduced left ventricular ejection fraction (LVEF), but long-term outcomes are still unknown. OBJECTIVE:To assess the long-term effects of AF ablation in patients with systolic heart failure according to rhythm outcome. METHODS:We inclu...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2013.12.031
更新日期:2014-03-01 00:00:00
abstract:BACKGROUND:Frequent premature ventricular contractions (PVCs) can cause disabling symptoms and decrease left ventricular ejection fraction. PVC burden, typically quantified by a 24-hour monitor, is one of the factors that determines the clinical management of PVCs. OBJECTIVE:The purpose of this study was to evaluate t...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2019.04.033
更新日期:2019-10-01 00:00:00
abstract:BACKGROUND:The effectiveness of radiofrequency catheter ablation (RFCA) in atrial tachyarrhythmias correlates with lesion transmurality. Ablation Index (AI) is an index that incorporates contact force, time, and radiofrequency power simultaneously and is able to predict lesion size and outcomes in RFCA of atrial fibril...
journal_title:Heart rhythm
pub_type: 杂志文章,多中心研究
doi:10.1016/j.hrthm.2019.01.005
更新日期:2019-06-01 00:00:00
abstract:BACKGROUND:The AdaptivCRT algorithm (aCRT) automatically adjusts atrioventricular delays each minute to achieve ventricular fusion through left ventricular (LV) or biventricular (BiV) pacing. aCRT is associated with superior clinical outcomes compared to standard BiV pacing, but the association of aCRT and subsequent a...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2019.05.012
更新日期:2019-07-01 00:00:00
abstract:BACKGROUND:Experience with retrieval of the Micra transcatheter pacing system (TPS) is limited because of its relatively newer technology. Although abandonment of the TPS at end of life is recommended, certain situations such as endovascular infection or device embolization warrant retrieval. OBJECTIVE:The purpose of ...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2018.02.008
更新日期:2018-06-01 00:00:00
abstract:BACKGROUND:Prior studies have reported that more than 20% of implantable cardioverter-defibrillator (ICD) implantations in the United States do not adhere to trial-based criteria. OBJECTIVE:We sought to investigate the patient characteristics associated with not meeting the inclusion criteria of the clinical trials th...
journal_title:Heart rhythm
pub_type: 杂志文章,多中心研究,随机对照试验
doi:10.1016/j.hrthm.2015.05.010
更新日期:2015-10-01 00:00:00
abstract:BACKGROUND:Negative tracheal pressure (NTP) during tracheal obstruction in obstructive apnea increases vagal tone and causes pronounced shortening of the atrial effective refractory period (AERP), thereby perpetuating atrial fibrillation (AF). The role of different atrial potassium channels under those conditions has n...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2011.07.018
更新日期:2011-12-01 00:00:00
abstract:BACKGROUND:Recent research findings have revealed a key role of oxidative DNA damage in the pathogenesis of atrial fibrillation (AF). Therefore, the circulating oxidative DNA damage marker 8-hydroxy-2'-deoxyguanosine (8-OHdG) may represent a biomarker for staging AF and identifying patients at risk for AF recurrence an...
journal_title:Heart rhythm
pub_type: 杂志文章
doi:10.1016/j.hrthm.2020.09.017
更新日期:2020-10-05 00:00:00
abstract:BACKGROUND:Lead malfunction is an important cause of morbidity and mortality in patients with an implantable cardioverter-defibrillator (ICD). We have shown that the failure of recalled high-voltage leads significantly increases after ICD generator replacement. However, generator replacement has not been recognized as ...
journal_title:Heart rhythm
pub_type: 杂志文章,多中心研究
doi:10.1016/j.hrthm.2014.06.018
更新日期:2014-10-01 00:00:00