Mucolytics, expectorants, and mucokinetic medications.

Abstract:

:In health, the airways are lined by a layer of protective mucus gel that sits atop a watery periciliary fluid. Mucus is an adhesive, viscoelastic gel, the biophysical properties of which are largely determined by entanglements of long polymeric gel-forming mucins, MUC5AC and MUC5B. This layer entraps and clears bacteria and inhibits bacterial growth and biofilm formation. It also protects the airway from inhaled irritants and from fluid loss. In diseases such as cystic fibrosis there is almost no mucin (and thus no mucus) in the airway; secretions consist of inflammatory-cell derived DNA and filamentous actin polymers, which is similar to pus. Retention of this airway pus leads to ongoing inflammation and airway damage. Mucoactive medications include expectorants, mucolytics, and mucokinetic drugs. Expectorants are meant to increase the volume of airway water or secretion in order to increase the effectiveness of cough. Although expectorants, such as guaifenesin (eg, Robatussin or Mucinex), are sold over the counter, there is no evidence that they are effective for the therapy of any form of lung disease, and when administered in combination with a cough suppressant such as dextromethorphan (the "DM" in some medication names) there is a potential risk of increased airway obstruction. Hyperosmolar saline and mannitol powder are now being used as expectorants in cystic fibrosis. Mucolytics that depolymerize mucin, such as N-acetylcysteine, have no proven benefit and carry a risk of epithelial damage when administered via aerosol. DNA-active medications such as dornase alfa (Pulmozyme) and potentially actin-depolymerizing drugs such as thymosin beta(4) may be of value in helping to break down airway pus. Mucokinetic agents can increase the effectiveness of cough, either by increasing expiratory cough airflow or by unsticking highly adhesive secretions from the airway walls. Aerosol surfactant is one of the most promising of this class of medications.

journal_name

Respir Care

journal_title

Respiratory care

authors

Rubin BK

subject

Has Abstract

pub_date

2007-07-01 00:00:00

pages

859-65

issue

7

eissn

0020-1324

issn

1943-3654

journal_volume

52

pub_type

杂志文章
  • Factors that delay COPD detection in the general elderly population.

    abstract:BACKGROUND:In patients with COPD, early detection and rapid treatment are essential to prevent its progression and exacerbations. OBJECTIVE:To identify factors that delay COPD detection. METHODS:We conducted a cross-sectional study of elderly COPD patients and healthy subjects in rural Japan. We measured respiratory ...

    journal_title:Respiratory care

    pub_type: 杂志文章

    doi:10.4187/respcare.01109

    authors: Horie J,Murata S,Hayashi S,Murata J,Miyazaki J,Mizota K,Horikawa E

    更新日期:2011-08-01 00:00:00

  • Computerized adventitious respiratory sounds as outcome measures for respiratory therapy: a systematic review.

    abstract:INTRODUCTION:There is a need to develop simple, noninvasive, and sensitive outcome measures for respiratory therapy. Adventitious respiratory sounds (ie, crackles and wheezes) can be objectively characterized with computerized respiratory sound analysis (CORSA) and have been shown to contribute for diagnosis purposes; ...

    journal_title:Respiratory care

    pub_type: 杂志文章,评审

    doi:10.4187/respcare.02765

    authors: Marques A,Oliveira A,Jácome C

    更新日期:2014-05-01 00:00:00

  • Should PEEP Titration Be Based on Chest Mechanics in Patients With ARDS?

    abstract::Functional residual capacity (FRC) is essentially the alveolar volume and a determinant of both oxygenation and respiratory system compliance (CRS). ARDS decreases FRC, and sufficient PEEP restores FRC; thus, assessments of PEEP by its impact on oxygenation and CRS are intimately linked. PEEP also can ameliorate or ag...

    journal_title:Respiratory care

    pub_type: 杂志文章,评审

    doi:10.4187/respcare.04657

    authors: Kallet RH

    更新日期:2016-06-01 00:00:00

  • Purchasing medical equipment: a protocol for decision making.

    abstract::In light of today's tight hospital financial picture caused by Medicare's prospective payment system and local constraints, capital expenditures must be made with great care and forethought. The process for purchase decision making should assess the need for the device; specifically identify what is required; carefull...

    journal_title:Respiratory care

    pub_type: 杂志文章

    doi:

    authors: Clark JT

    更新日期:1985-08-01 00:00:00

  • Problems in delivering desired oxygen concentrations from jet nebulizers to patients via face tents.

    abstract::We compared the actual oxygen concentration reaching the airway of 10 patients with the preset oxygen concentration delivered from single and double jet nebulizers to face tents. We measured hypopharyngeal oxygen concentration (FHO2), which closely approximates tracheal fractional inspired oxygen concentration (FIO2),...

    journal_title:Respiratory care

    pub_type: 杂志文章

    doi:

    authors: Monast RL,Kaye W

    更新日期:1984-10-01 00:00:00

  • Pediatric Oxygen Therapy: A Review and Update.

    abstract::Oxygen is a colorless, odorless, tasteless gas that is utilized by the body for respiration. Oxygen has played a major role in respiratory care. Oxygen therapy is useful in treating hypoxemia but is often thought of as a benign therapy. After many years of study, we have learned a great deal of the benefits and potent...

    journal_title:Respiratory care

    pub_type: 杂志文章,评审

    doi:10.4187/respcare.05245

    authors: Walsh BK,Smallwood CD

    更新日期:2017-06-01 00:00:00

  • Ventilator-integrated jet nebulization systems: tidal volume control and efficiency of synchronization.

    abstract:BACKGROUND:Jet nebulizers constitute the aerosolization devices most frequently used during mechanical ventilation. Continuous nebulization can influence the delivered tidal volume (V(T)) and lead to significant medication loss during expiration. Ventilators thus provide integrated jet nebulization systems that are syn...

    journal_title:Respiratory care

    pub_type: 杂志文章

    doi:10.4187/respcare.02637

    authors: Ehrmann S,Lyazidi A,Louis B,Isabey D,Le Pennec D,Brochard L,Apiou-Sbirlea G

    更新日期:2014-10-01 00:00:00

  • Use of a computerized respiratory care record system to study utilization of IPPB therapy.

    abstract::Increases in the utilization of respiratory therapy and the need to avoid its misuse have placed increasing management responsibilities on medical and technical supervisors of respiratory care services. To improve our managerial capabilities we designed a computerized respiratory care record system. Respiratory therap...

    journal_title:Respiratory care

    pub_type: 杂志文章

    doi:

    authors: Chase CR,Merz BA,Shinozaki T,Greenwood SA,Deane RS

    更新日期:1983-03-01 00:00:00

  • Increased Accuracy After Adjustment of Spirometry Threshold for Diagnosing COPD Based on Pre-Bronchodilator FEV1/FVC.

    abstract:BACKGROUND:COPD is a leading cause of morbidity and mortality worldwide. Spirometry is the most common lung function test for diagnosing COPD with a post-bronchodilator FEV1/FVC < 0.70 confirming the presence of the disease. However, diagnosticians appear reluctant to use bronchodilators, which have been linked to the ...

    journal_title:Respiratory care

    pub_type: 杂志文章

    doi:10.4187/respcare.06148

    authors: Kronborg T,Hangaard S,Cichosz SL,Hejlesen O

    更新日期:2019-01-01 00:00:00

  • Comparison of different exercise tests in assessing outcomes of pulmonary rehabilitation.

    abstract:INTRODUCTION:Common modalities of clinical exercise testing for outcome measurement after pulmonary rehabilitation (PR) include walk tests, progressive cycle ergometry, and cycle endurance testing. We hypothesized that patients' responses to PR, as measured by those 3 tests, are differentially correlated, and we design...

    journal_title:Respiratory care

    pub_type: 杂志文章

    doi:

    authors: Ong KC,Chong WF,Soh C,Earnest A

    更新日期:2004-12-01 00:00:00

  • High-Flow Nasal Cannula in a Mixed Adult ICU.

    abstract:BACKGROUND:Humidified, high-flow nasal cannula (HFNC) enables mucociliary clearance, accurate oxygen measurement, precise control of flow, and low-level positive airway pressure. There is sparse information concerning the timing of HFNC on patient outcomes such as incidence of adverse events during hospitalization, ICU...

    journal_title:Respiratory care

    pub_type: 杂志文章

    doi:10.4187/respcare.04016

    authors: Gaunt KA,Spilman SK,Halub ME,Jackson JA,Lamb KD,Sahr SM

    更新日期:2015-10-01 00:00:00

  • Spontaneously breathing lung model comparison of work of breathing between automatic tube compensation and pressure support.

    abstract:INTRODUCTION:Automatic tube compensation (ATC), a new ventilation mode that compensates for the work of breathing imposed by endotracheal tube resistance, recently became commercially available. METHODS:We conducted a laboratory study with a lung model and a Nellcor Puritan Bennett 840 ventilator to compare ATC and pr...

    journal_title:Respiratory care

    pub_type: 杂志文章

    doi:

    authors: Fujino Y,Uchiyama A,Mashimo T,Nishimura M

    更新日期:2003-01-01 00:00:00

  • Metabolic and nutrition support in the chronic critical illness syndrome.

    abstract::Technological innovations in the ICU have led to artificially prolonged life, with an associated cost. Chronic critical illness (CCI) occurs in patients with prolonged mechanical ventilation and allostatic overload, and is associated with a discrete and consistent metabolic syndrome. Metabolic interventions are extra...

    journal_title:Respiratory care

    pub_type: 杂志文章,评审

    doi:10.4187/respcare.01620

    authors: Schulman RC,Mechanick JI

    更新日期:2012-06-01 00:00:00

  • A review of options for treating sialorrhea in amyotrophic lateral sclerosis.

    abstract::Sialorrhea or drooling represents quite a common problem in patients with amyotrophic lateral sclerosis (ALS). In this review, we describe the possible treatments for this issue. Current medical management is not always effective: anticholinergic drugs (atropine, glycopyrrolate, amitriptyline, hyoscyamine, and transde...

    journal_title:Respiratory care

    pub_type: 杂志文章,评审

    doi:10.4187/respcare.02856

    authors: Banfi P,Ticozzi N,Lax A,Guidugli GA,Nicolini A,Silani V

    更新日期:2015-03-01 00:00:00

  • Comparison of Vibrating Mesh, Jet, and Breath-Enhanced Nebulizers During Mechanical Ventilation.

    abstract:BACKGROUND:This study compared 3 nebulizer technologies for inter- and intradevice reproducibility, humidification, and fill volume sensitivity during mechanical ventilation: a breath-enhanced jet nebulizer, a vibrating mesh nebulizer, and a jet nebulizer. The breath-enhanced jet nebulizer featured a new design located...

    journal_title:Respiratory care

    pub_type: 杂志文章

    doi:10.4187/respcare.07639

    authors: Ashraf S,McPeck M,Cuccia AD,Smaldone GC

    更新日期:2020-10-01 00:00:00

  • Work of breathing in adaptive pressure control continuous mandatory ventilation.

    abstract:BACKGROUND:Adaptive pressure control is a mode of mechanical ventilation where inflation pressure is adjusted by the ventilator to achieve a target tidal volume (VT). This means that as patient effort increases, inflation pressure is reduced, which may or may not be clinically appropriate. The purpose of this study was...

    journal_title:Respiratory care

    pub_type: 杂志文章

    doi:

    authors: Mireles-Cabodevila E,Chatburn RL

    更新日期:2009-11-01 00:00:00

  • 2000 Donald F. Egan Scientific Lecture. Are respiratory therapists effective? Assessing the evidence.

    abstract::In the current cost-attentive health care climate, the effectiveness of various providers in delivering care is being examined closely. To evaluate the effectiveness of respiratory therapists (RTs) in delivering respiratory care in the intensive care unit (ICU), in adult non-ICU inpatient care, and in ambulatory care,...

    journal_title:Respiratory care

    pub_type: 杂志文章,meta分析

    doi:

    authors: Stoller JK

    更新日期:2001-01-01 00:00:00

  • The accuracy of transcutaneous PCO2 in subjects with severe brain injury: a comparison with end-tidal PCO2.

    abstract:BACKGROUND:In patients suffering from brain injury, end-tidal PCO2 (PETCO2 ) monitoring is controversial, but transcutaneous PCO2 (PtcCO2 ), which is noninvasive and utilizes immediate display, may be an alternative method. We hypothesized that PtcCO2 would be more accurate than PETCO2 for monitoring PaCO2 in patients ...

    journal_title:Respiratory care

    pub_type: 杂志文章

    doi:10.4187/respcare.02726

    authors: Rosier S,Launey Y,Bleichner JP,Laviolle B,Jouve A,Malledant Y,Seguin P

    更新日期:2014-08-01 00:00:00

  • AARC Clinical Practice Guidelines. Endotracheal suctioning of mechanically ventilated patients with artificial airways 2010.

    abstract::An electronic literature search for articles published between January 1990 and October 2009 was conducted by using MEDLINE, CINAHL, and Cochrane Library databases. The update of this clinical practice guideline is the result of reviewing a total of 114 clinical trials, 62 reviews and 6 meta-analyses on endotracheal s...

    journal_title:Respiratory care

    pub_type: 杂志文章,实务指引

    doi:

    authors: American Association for Respiratory Care.

    更新日期:2010-06-01 00:00:00

  • Physiological Responses During Field Walking Tests in Adults with Bronchiectasis.

    abstract:BACKGROUND:Field walking tests are commonly used in patients with chronic pulmonary diseases for assessment of functional capacity. However, the physiological demands and magnitude of desaturation on 6-min walk test (6MWT), incremental shuttle walk test (ISWT), and endurance shuttle walk test (ESWT) have not been inves...

    journal_title:Respiratory care

    pub_type: 杂志文章

    doi:10.4187/respcare.07171

    authors: Corso SD,Boldorini JC,de Camargo AA,José A,Rached SZ,Athanazio RA,Stelmach R,Holland AE

    更新日期:2020-05-01 00:00:00

  • Filamin A mutation may be associated with diffuse lung disease mimicking bronchopulmonary dysplasia in premature newborns.

    abstract::Bronchopulmonary dysplasia (BPD) is a common long-term complication in premature newborns requiring ventilatory support and is the most common cause of chronic diffuse lung disease in this population. We present the clinical course of a premature newborn with a complicated neonatal respiratory course that was initiall...

    journal_title:Respiratory care

    pub_type: 杂志文章

    doi:10.4187/respcare.02847

    authors: Lord A,Shapiro AJ,Saint-Martin C,Claveau M,Melançon S,Wintermark P

    更新日期:2014-11-01 00:00:00

  • Effects of decreasing the frequency of ventilator circuit changes to every 7 days on the rate of ventilator-associated pneumonia in a Beijing hospital.

    abstract:INTRODUCTION:We investigated whether decreasing ventilator circuit changes from every 2 days to every 7 days would impact ventilator-associated pneumonia rates at our institution. METHODS:All mechanically ventilated patients at Peking Union Medical College Hospital were studied over a 21 month period. From March 1998 ...

    journal_title:Respiratory care

    pub_type: 杂志文章

    doi:

    authors: Han JN,Liu YP,Ma S,Zhu YJ,Sui SH,Chen XJ,Luo DM,Adams AB,Marini JJ

    更新日期:2001-09-01 00:00:00

  • Neonatal Pneumothorax Pressures Surpass Higher Threshold in Lung Recruitment Maneuvers: An In Vivo Interventional Study.

    abstract:BACKGROUND:Causing pneumothorax is one of the main concerns of lung recruitment maneuvers in pediatric patients, especially newborns. Therefore, these maneuvers are not performed routinely during anesthesia. Our objective was to determine the pressures that cause pneumothorax in healthy newborns by a prospective experi...

    journal_title:Respiratory care

    pub_type: 杂志文章

    doi:10.4187/respcare.04250

    authors: González-Pizarro P,García-Fernández J,Canfrán S,Gilsanz F

    更新日期:2016-02-01 00:00:00

  • Decreasing Unplanned Extubation in the Neonatal ICU With a Focus on Endotracheal Tube Tip Position.

    abstract:BACKGROUND:Unplanned extubation (UE) is an important quality metric in the neonatal ICU that is associated with hypoxia, bradycardia, and risk for airway trauma with emergent re-intubation. Initial efforts to reduce UE in our level 4 neonatal ICU included standardized securement of the endotracheal tube (ETT) and requi...

    journal_title:Respiratory care

    pub_type: 杂志文章

    doi:10.4187/respcare.07446

    authors: Morris HF,Schuller L,Archer J,Niesen A,Ellsworth S,Egan J,Rao R,Vesoulis ZA,Mathur AM

    更新日期:2020-11-01 00:00:00

  • Pulmonary rehabilitation for chronic obstructive pulmonary disease: a scientific and political agenda.

    abstract::Pulmonary rehabilitation (PR) is the standard of care for patients suffering chronic obstructive pulmonary disease (COPD). This report describes and defines PR and reviews the evidence regarding the efficacy of PR. COPD management guidelines that include PR have been published by the European Respiratory Society, the ...

    journal_title:Respiratory care

    pub_type: 杂志文章

    doi:

    authors: Fahy BF

    更新日期:2004-01-01 00:00:00

  • Successful extracorporeal membrane oxygenation for respiratory failure in an infant with DiGeorge anomaly, following thymus transplantation.

    abstract::We report the first successful use of venovenous extracorporeal membrane oxygenation (ECMO) for refractory respiratory failure in an infant with DiGeorge anomaly, following thymus transplantation. A 23-month-old female with complete immune-incompetent DiGeorge anomaly 65 days after allogenic thymus transplantation was...

    journal_title:Respiratory care

    pub_type: 杂志文章

    doi:10.4187/respcare.01051

    authors: Hornik CP,Hartman ME,Markert ML,Lodge AJ,Cheifetz IM,Turner DA

    更新日期:2011-06-01 00:00:00

  • Feasibility and potential cost/benefit of routine isoflurane sedation using an anesthetic-conserving device: a prospective observational study.

    abstract:BACKGROUND:Inhaled sedation is efficient and easily controllable; in low concentrations it causes minimal changes in the patient and very little interference with hemodynamics. Awakening after inhaled sedation is quick and predictable. The major reason inhaled sedation has not become widely used in intensive care is th...

    journal_title:Respiratory care

    pub_type: 杂志文章

    doi:

    authors: L'her E,Dy L,Pili R,Prat G,Tonnelier JM,Lefevre M,Renault A,Boles JM

    更新日期:2008-10-01 00:00:00

  • High-frequency oscillation of the airway and chest wall.

    abstract::High-frequency oscillation (HFO), applied to either the airway or chest wall, has been associated with changes in sputum attributes and clearance. The evolution of evidence, both in vitro and in vivo, supporting the use of HFO is reviewed. Devices that apply HFO to the airway range from the relatively simple mechanica...

    journal_title:Respiratory care

    pub_type: 杂志文章,评审

    doi:

    authors: Fink JB,Mahlmeister MJ

    更新日期:2002-07-01 00:00:00

  • Complications of Prone Positioning During Extracorporeal Membrane Oxygenation for Respiratory Failure: A Systematic Review.

    abstract:BACKGROUND:Extracorporeal membrane oxygenation (ECMO) is often used in patients with severe respiratory failure to improve oxygenation and survival. ECMO gives the lungs an opportunity to rest and recover. The addition of prone positioning therapy used concurrently with ECMO can further aid in optimizing alveolar recru...

    journal_title:Respiratory care

    pub_type: 杂志文章,评审

    doi:10.4187/respcare.03882

    authors: Culbreth RE,Goodfellow LT

    更新日期:2016-02-01 00:00:00

  • Congenital pulmonary airway malformation: a case report and review of the literature.

    abstract::Congenital parenchymal lung malformations have an estimated incidence at 1:25,000-1:35,000 births. We present a case of this rare congenital abnormality in a 38 year-old male, review the current literature with discussion of proposed causes, malignant potential, and management strategies. A 38-year-old white male pre...

    journal_title:Respiratory care

    pub_type: 杂志文章,评审

    doi:10.4187/respcare.00727

    authors: McDonough RJ,Niven AS,Havenstrite KA

    更新日期:2012-02-01 00:00:00