Abstract:
BACKGROUND:Field walking tests are commonly used in patients with chronic pulmonary diseases for assessment of functional capacity. However, the physiological demands and magnitude of desaturation on 6-min walk test (6MWT), incremental shuttle walk test (ISWT), and endurance shuttle walk test (ESWT) have not been investigated in patients with bronchiectasis. The objective of this study was to compare the physiological responses and the magnitude of desaturation of subjects with bronchiectasis when performing the 6MWT, ISWT, and ESWT. METHODS:Thirty-two subjects underwent the 6MWT, ISWT, and ESWT on 3 different days. Pulmonary gas exchange, heart rate, and [Formula: see text] were measured in all tests. RESULTS:There were no differences in the peak rate of oxygen uptake, ventilation, dyspnea, and leg fatigue between the tests. Equivalent cardiac demand (ie, heart rate at peak) was observed with the 6MWT (137 ± 21 beats/min) and the ESWT (142 ± 21 beats/min), but this was lower in the ISWT (135 ± 19 beats/min) compared to ESWT (P < .05). Most subjects achieved a vigorous exercise intensity (heart rate of 70-90% of predicted) in all tests. There was no difference in desaturation among the tests (6MWT: -6.8 ± 6.6%, ISWT: -6.1 ± 6.0%, and ESWT: -7.0 ± 5.4%). CONCLUSIONS:The 6MWT, ISWT, and ESWT induced similar physiological responses at the peak of exercise, eliciting a vigorous exercise intensity. The magnitude of desaturation was similar across tests. This means these tests can be used interchangeably for evaluation of exercise-induced desaturation.
journal_name
Respir Carejournal_title
Respiratory careauthors
Corso SD,Boldorini JC,de Camargo AA,José A,Rached SZ,Athanazio RA,Stelmach R,Holland AEdoi
10.4187/respcare.07171subject
Has Abstractpub_date
2020-05-01 00:00:00pages
618-624issue
5eissn
0020-1324issn
1943-3654pii
respcare.07171journal_volume
65pub_type
杂志文章相关文献
Respiratory Care文献大全abstract:BACKGROUND:Jet nebulizers constitute the aerosolization devices most frequently used during mechanical ventilation. Continuous nebulization can influence the delivered tidal volume (V(T)) and lead to significant medication loss during expiration. Ventilators thus provide integrated jet nebulization systems that are syn...
journal_title:Respiratory care
pub_type: 杂志文章
doi:10.4187/respcare.02637
更新日期:2014-10-01 00:00:00
abstract:INTRODUCTION:There is no published standard for the ratio of staff to patients during exercise sessions in outpatient pulmonary rehabilitation. This lack of a standard raises concern about patient safety and the ability to monitor patients adequately. OBJECTIVE:Determine a staff-to-patient ratio standard by examining ...
journal_title:Respiratory care
pub_type: 杂志文章
doi:
更新日期:2001-07-01 00:00:00
abstract:BACKGROUND:Airway remodeling is a characteristic structural change that occurs extensively in the airways of patients with asthma. The change can be evaluated by measuring airway dimensions by using high-resolution computed tomography. This study aimed to explore the variation trends of airway dimensions from the secon...
journal_title:Respiratory care
pub_type: 杂志文章
doi:10.4187/respcare.06050
更新日期:2018-11-01 00:00:00
abstract::We present a patient with acute-onset dyspnea and unexplained severe hypoxemia. No signs of severe cardiopulmonary disease, pulmonary arterial hypertension, or pulmonary embolism were present. The patient was diagnosed with hepatopulmonary syndrome, since liver disease of alcoholic origin was present, markedly increa...
journal_title:Respiratory care
pub_type: 杂志文章
doi:10.4187/respcare.01612
更新日期:2012-11-01 00:00:00
abstract:BACKGROUND:Portable oxygen devices simplify and facilitate patient therapy. This study was designed to compare S(pO2) and patient satisfaction with a portable oxygen concentrator or a combined system consisting of a fixed device with continuous-flow oxygen dispensation and a portable device with pulse dispensation for ...
journal_title:Respiratory care
pub_type: 杂志文章,多中心研究,随机对照试验
doi:10.4187/respcare.03470
更新日期:2015-03-01 00:00:00
abstract:BACKGROUND:Recent literature suggests that optimization of tidal driving pressure (ΔP) would be a better variable to target for lung protection at the bedside than tidal volume (VT) or plateau pressure (Pplat), the traditional indicators of ventilator-induced lung injury. However, the usual range or variability of ΔP o...
journal_title:Respiratory care
pub_type: 杂志文章
doi:10.4187/respcare.06599
更新日期:2019-08-01 00:00:00
abstract::The data available to guide clinical management of acute lung injury and acute respiratory distress syndrome are much more limited for infants and children than for adult patients. This paper reviews the available medical data and the pertinent physiology on the management of pediatric patients with acute lung injury...
journal_title:Respiratory care
pub_type: 杂志文章
doi:10.4187/respcare.01515
更新日期:2011-10-01 00:00:00
abstract::Endotracheal intubation can lead to iatrogenic trauma to the upper airways. Superficial mucosal tears in the mouth, pharynx, or larynx are common and can cause secondary infection and acute respiratory distress due to massive air leak. We report a patient who sustained a severe 5-cm tracheal laceration and subcutaneou...
journal_title:Respiratory care
pub_type: 杂志文章
doi:10.4187/respcare.00891
更新日期:2011-06-01 00:00:00
abstract:BACKGROUND:Readmission of mechanically ventilated patients to an ICU within 7 d reflects not only patient safety but also the quality of care of the ICU. This study aimed to investigate the risk and related factors for readmission to an ICU within 7 d in mechanically ventilated subjects. METHODS:A total of 658,452 mec...
journal_title:Respiratory care
pub_type: 杂志文章
doi:10.4187/respcare.03868
更新日期:2015-12-01 00:00:00
abstract::COPD is a complex collection of conditions. All share the feature of limited expiratory air flow. It is a "disease" in the same sense as is "chronic renal failure." Like most other chronic organ failure "diseases," COPD has disparate causes, and patients are heterogeneous in their prognosis and response to treatment. ...
journal_title:Respiratory care
pub_type:
doi:10.4187/respcare.01419
更新日期:2011-08-01 00:00:00
abstract::A number of adjuncts to mechanical ventilation have been the focus of recent research. Automatic tube compensation (the regulation of airway pressure by estimation of tracheal pressure) appears to be an ideal approach to unloading the resistive effort imposed by the endotracheal tube. Randomized controlled trials have...
journal_title:Respiratory care
pub_type: 杂志文章,评审
doi:
更新日期:2002-03-01 00:00:00
abstract:BACKGROUND:Limited adult data suggest that airway driving pressure might better reflect the potential risk for lung injury than tidal volume based on ideal body weight, and the parameter correlates with mortality in ARDS. There is a lack of data about the effect of driving pressure on mortality in pediatric ARDS. This ...
journal_title:Respiratory care
pub_type: 杂志文章
doi:10.4187/respcare.08024
更新日期:2020-10-06 00:00:00
abstract:BACKGROUND:Obstructive lung disease is diagnosed by a decreased ratio of FEV1 to the vital capacity (VC). Although the most commonly used VC is FVC, American Thoracic Society guidelines suggest alternative VCs, for example, slow VC (SVC), may offer a more-accurate evaluation of breathing capacity. There is recent evide...
journal_title:Respiratory care
pub_type: 杂志文章
doi:10.4187/respcare.06419
更新日期:2019-07-01 00:00:00
abstract::Traumatic brain injury is a problem that affects millions of Americans yearly and for which there is no definitive treatment that improves outcome. Continuous brain tissue oxygen (PbtO2 ) monitoring is a complement to traditional brain monitoring techniques, such as intracranial pressure and cerebral perfusion pressur...
journal_title:Respiratory care
pub_type: 杂志文章,评审
doi:10.4187/respcare.04962
更新日期:2016-09-01 00:00:00
abstract:BACKGROUND:The use of neurally-adjusted ventilatory assist (NAVA) during noninvasive ventilation (NIV) results in better patient-ventilator interaction. Whether this improves clinical outcomes lacks dedicated study. METHODS:In this randomized controlled trial, we compared NAVA with PSV for delivering NIV in consecutiv...
journal_title:Respiratory care
pub_type: 杂志文章
doi:10.4187/respcare.07952
更新日期:2021-02-01 00:00:00
abstract::The presence of bronchiectasis (BR) in patients with rheumatoid arthritis (RA) has been recognized for many decades; nevertheless, little research has been undertaken in this area. It is important to recognize that BR coexistent with RA differs from the other types of BR. The purpose of this descriptive review was to ...
journal_title:Respiratory care
pub_type: 杂志文章,评审
doi:10.4187/respcare.01857
更新日期:2013-04-01 00:00:00
abstract:BACKGROUND:The impulse oscillometry system (IOS) is increasingly used to evaluate lung function, but individual results must be compared with appropriate reference values. We aimed to obtain such reference values in Mexican children and adolescents. METHODS:Healthy subjects were recruited from kindergartens and school...
journal_title:Respiratory care
pub_type: 杂志文章
doi:10.4187/respcare.03374
更新日期:2015-01-01 00:00:00
abstract:UNLABELLED:We conducted a prospective study of 50 consecutive postoperative patients over a 5-month period to characterize the bacterial contamination of ultrasonic nebulizers (USNs) after 24, 48, and 72 hours (h) of use. METHODS:Samples of the USN effluent mist and reservoir fluid were cultured and the results were c...
journal_title:Respiratory care
pub_type: 杂志文章
doi:
更新日期:1986-12-01 00:00:00
abstract:BACKGROUND:Treatment of bronchiectasis includes drugs, oxygen therapy, and bronchial-clearance maneuvers. OBJECTIVE:To assess the safety and efficacy of intrapulmonary percussive ventilation (IPV) compared to traditional standard chest physical therapy in patients with bronchiectasis and productive cough. METHODS:In ...
journal_title:Respiratory care
pub_type: 杂志文章,随机对照试验
doi:10.4187/respcare.01098
更新日期:2011-07-01 00:00:00
abstract:UNLABELLED:The development of an expanded understanding of employees' reaction to their job may be important for improvement in the quality of work life and of services rendered. We sought to determine the factors, or rewards, that significantly affect respiratory therapists' job satisfaction. METHOD:Questionnaires de...
journal_title:Respiratory care
pub_type: 杂志文章
doi:
更新日期:1989-03-01 00:00:00
abstract::Although oral and injectable drug formulations still dominate the market, interest in pulmonary delivery has been rising steadily. Given patients' desire for an alternative to injections, and recent advances in aerosol science and pulmonary medicine, the potential for improved disease management outcomes by using aero...
journal_title:Respiratory care
pub_type: 杂志文章,评审
doi:
更新日期:2000-07-01 00:00:00
abstract:BACKGROUND:Previous studies have demonstrated the safety of flexible bronchoscopy (FB) in mechanically ventilated subjects. However, the safety of FB in adult subjects receiving extracorporeal membrane oxygenation (ECMO) has not been described previously. METHODS:A retrospective review was conducted of all adult subje...
journal_title:Respiratory care
pub_type: 杂志文章
doi:10.4187/respcare.04456
更新日期:2016-05-01 00:00:00
abstract:BACKGROUND:Exercise-induced bronchoconstriction (EIB) can lead to long-term respiratory illness and even death. EIB prevalence rates are both high and variable in college athletes. Also, prevalence rates may be underestimated due to ineffective screening. The purpose of this study is to investigate the prevalence of EI...
journal_title:Respiratory care
pub_type: 杂志文章
doi:10.4187/respcare.04553
更新日期:2016-07-01 00:00:00
abstract::Pressure support ventilation (PSV) is a commonly used mode. It is patient-triggered, pressure-limited, and (normally) flow-cycled. Triggering difficulty occurring during PSV is usually due to intrinsic positive end-expiratory pressure. The airway pressure generated at the initiation of inhalation is determined by the ...
journal_title:Respiratory care
pub_type: 杂志文章,评审
doi:
更新日期:2005-02-01 00:00:00
abstract::A 20-year-old man was admitted in the neurology ICU after the drainage of a large frontal hematoma related to the spontaneous bleeding of a recently diagnosed cavernoma. On admission the Glasgow coma score was 4/15, with evidence of sub-falcorial herniation and elevated intracranial pressure. On the 4th postoperative...
journal_title:Respiratory care
pub_type: 杂志文章
doi:10.4187/respcare.01322
更新日期:2012-07-01 00:00:00
abstract::Hospital-wide computerized information systems evolved from the need to capture patient information and perform billing and other financial functions. These systems, however, have fallen short of meeting the needs of respiratory care departments regarding work load assessment, productivity management, and the level of...
journal_title:Respiratory care
pub_type: 杂志文章,评审
doi:
更新日期:2004-04-01 00:00:00
abstract:BACKGROUND:Patient work of breathing (WOB) during assisted ventilation is reduced when inspiratory flow (V(I)) from the ventilator exceeds patient flow demand. Patients in acute respiratory failure often have unstable breathing patterns and their requirements for V(I) may change from breath to breath. Volume control ve...
journal_title:Respiratory care
pub_type: 临床试验,杂志文章
doi:
更新日期:2000-09-01 00:00:00
abstract::Pulmonary rehabilitation (PR) is the standard of care for patients suffering chronic obstructive pulmonary disease (COPD). This report describes and defines PR and reviews the evidence regarding the efficacy of PR. COPD management guidelines that include PR have been published by the European Respiratory Society, the ...
journal_title:Respiratory care
pub_type: 杂志文章
doi:
更新日期:2004-01-01 00:00:00
abstract::Infants have low tidal volume, vital capacity, and functional residual capacity, and short respiratory cycles (low I:E ratio), which result in a low residence time for aerosol particles and, thus, low pulmonary deposition of aerosol particles (< 1% of the nominal dose), compared to adults (8-22%). Scintigraphy data su...
journal_title:Respiratory care
pub_type: 杂志文章,评审
doi:
更新日期:2004-06-01 00:00:00
abstract:BACKGROUND:The primary focus of previous aerosol research during mechanical ventilation was the endotracheal tube (ETT). Consequently, there are limited data in the literature on the delivery of inhaled medications administered with different aerosol devices in mechanically ventilated patients with a tracheostomy tube ...
journal_title:Respiratory care
pub_type: 杂志文章
doi:10.4187/respcare.04125
更新日期:2015-11-01 00:00:00