Right ventricle shape and contraction patterns and relation to magnetic resonance imaging findings.

Abstract:

OBJECTIVE:To analyze and to describe the shape and contraction of the normal right ventricle (RV) as visualized by magnetic resonance imaging (MRI). METHODS:Thirty normal volunteers were imaged using cine MRI in axial, short-axis, and long-axis planes. The shape and contraction of the RV were qualitatively evaluated. Quantitative evaluation of RV shape was performed by calculating the angle subtended between the planes of horizontal long-axis view (HLA) and axial view and the RV base-to-apex distance. Multiplanar reformation was used to visualize changes between corresponding views. RESULTS:The spectrum of major RV shape (wedge, box, and round) was more variable on axial images (17%, 43%, and 23%, respectively) than on HLA images (63%, 20%, and 0%, respectively). Focal outpouching of the RV free wall was more frequent on the axial view than on the HLA view. The subtended plane angle and base-to-apex distance showed statistically significant dependence indicative of an artificially foreshortened RV in the axial view with a direct influence on RV variations. CONCLUSIONS:With increasing subtended angles, variation of the normal RV appearance is substantially higher on axial views compared with HLA views.

journal_name

J Comput Assist Tomogr

authors

Fritz J,Solaiyappan M,Tandri H,Bomma C,Genc A,Claussen CD,Lima JA,Bluemke DA

doi

10.1097/01.rct.0000179596.86221.38

keywords:

subject

Has Abstract

pub_date

2005-11-01 00:00:00

pages

725-33

issue

6

eissn

0363-8715

issn

1532-3145

pii

00004728-200511000-00002

journal_volume

29

pub_type

杂志文章
  • Myocardial perfusion magnetic resonance imaging using sliding-window conjugate-gradient HYPR methods in canine with stenotic coronary arteries.

    abstract:PURPOSE:First-pass perfusion magnetic resonance imaging (MRI) is a promising technique for detecting ischemic heart disease. However, the diagnostic value of the method is limited by the low spatial coverage, resolution, signal-to-noise ratio (SNR), and cardiac motion-related image artifacts. A combination of sliding w...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0b013e3181e9e9dd

    authors: Ge L,Kino A,Lee D,Dharmakumar R,Carr JC,Li D

    更新日期:2010-09-01 00:00:00

  • Image noise and radiation dose using an automatic tube current modulation technique at 64-detector computed tomography: effect of off-center patient position, bowtie filter type, and scan projection radiograph.

    abstract::We describe the effect of the off-center position, the bowtie filter type, and the direction of scan projection radiograph on the radiation dose and image noise of 64-detector computed tomographic scans using the automatic tube current modulation technique. On anteroposterior scan projection radiographs, the tube curr...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0b013e31819d6f6f

    authors: Funama Y,Taguchi K,Awai K,Sakabe D,Shimamura M,Yamashita Y

    更新日期:2009-11-01 00:00:00

  • Computed tomographic and clinicopathological features of inflammatory pseudotumor of the spleen.

    abstract:OBJECTIVE:Our goal was to elucidate the computed tomographic (CT) and clinicopathological features of inflammatory pseudotumor of the spleen. METHODS:Computed tomographic findings and clinic materials of 4 patients with inflammatory pseudotumor of the spleen were reviewed and compared with pathologic findings. RESULT...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0000000000000215

    authors: Lu T,Yang C

    更新日期:2015-05-01 00:00:00

  • Epiploic appendicitis: CT characteristics.

    abstract::Acute infarction of an appendix epiploica resulted in an inflammatory process involving the caudal aspect of the transverse colon and the adjacent greater omentum. Computed tomography demonstrated prominent linear soft tissue densities, an increase in CT number of the involved greater omentum, and posterior displaceme...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198601000-00032

    authors: Danielson K,Chernin MM,Amberg JR,Goff S,Durham JR

    更新日期:1986-01-01 00:00:00

  • Motion Artifact Reduction From High-Pitch Dual-Source Computed Tomography Pulmonary Angiography.

    abstract:PURPOSE:The purpose of this study was to compare quantitative and qualitative measures of aortic, cardiac, and respiratory motion artifact between high-pitch dual-source (DS) and single-source (SS) computed tomography pulmonary angiography (CTPA) protocols. METHODS:This institutional review board-approved, Health Insu...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0000000000000736

    authors: Bunch PM,Fulwadhva UP,Wortman JR,Primak AN,Madan R,Steigner ML,Sodickson AD

    更新日期:2018-07-01 00:00:00

  • The infraconal compartment: a multidirectional pathway for spread of disease between the extraperitoneal abdomen and pelvis.

    abstract:PURPOSE:The space below the kidneys where the anterior and posterior pararenal spaces converge has been defined only vaguley in the past. We describe observations on clinical CT cases and studies on cadavers that lead to a refinement in the terminology for this extraperitoneal compartment. METHOD:Abdominal/pelvic CT s...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-199703000-00011

    authors: Beaulieu CF,Mindelzun RE,Dolph J,Jeffrey RB Jr

    更新日期:1997-03-01 00:00:00

  • Anomalous systemic arterialization to normal basal segments of the left lower lobe: helical CT and CTA findings.

    abstract:PURPOSE:The purpose of this work was to evaluate the helical CT and CT angiography (CTA) findings of anomalous systemic artery (ASA) to the basal segments of the left lower lobe (LLL). METHOD:Three patients (two had hemoptysis, one was asymptomatic) with blotchy nodular density in the LLL revealed on chest radiographs...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-200011000-00026

    authors: Ko SF,Ng SH,Lee TY,Wan YL,Lee CM,Hsieh MJ,Chen MC

    更新日期:2000-11-01 00:00:00

  • Quantification of vasa vasorum density in multi-slice computed tomographic coronary angiograms: role of computed tomographic image voxel size.

    abstract:OBJECTIVE:This study is motivated by the possibility of using computed tomography (CT) to detect early coronary atherosclerosis by the increased CT values within the arterial wall resulting from vasa vasorum proliferation. METHODS:Coronary arteries (n = 5) with early atherosclerotic changes were injected with Microfil...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0b013e3181bb0d32

    authors: Moritz R,Eaker DR,Langheinrich AC,Jorgensen SM,Bohle RM,Ritman EL

    更新日期:2010-03-01 00:00:00

  • Computed tomography of spontaneous acute cervical epidural hematoma.

    abstract::Cervical spinal epidural hematoma is a rare cause of acute neurologic syndromes including paralysis of various types. Although devastating, it can be successfully treated surgically if recognized early. We report two cases of spontaneous cervical epidural hematoma diagnosed by computed tomography, the first with a pla...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:

    authors: Haykal HA,Wang AM,Zamani AA,Rumbaugh CL

    更新日期:1984-04-01 00:00:00

  • Sectional neuroanatomy of the lumbosacral spine (L1-S5).

    abstract::This paper will review the lumbosacral spine (L1-S5). Procedures performed in the lumbosacral spine include electromyography, spinal stimulator implants, spinal infusion implants for spasticity or pain medications, sacroiliac spine injections, facet blocks, and steroid injections. Complications from these procedures i...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0b013e3181560a51

    authors: Chiou-Tan FY,Miller JS,Zhang H,Kass JS,Taber KH

    更新日期:2007-09-01 00:00:00

  • Characteristic CT pattern of giant superior mesenteric artery aneurysms.

    abstract::The presence of superior mesenteric artery aneurysms may be suspected on the basis of clinical and ultrasound findings. These lesions have a suggestive appearance on computed tomography, but for a preoperative assessment angiography is always indicated. Two cases are presented. ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198010000-00009

    authors: Passariello R,Simonetti G,Rovighi L,Ciolina A

    更新日期:1980-10-01 00:00:00

  • Display of three-dimensional information in computed tomography.

    abstract::From a sequence of computed tomograms of two-dimensional transverse slices of a body one can build up a three-dimensional array of numbers containing spatial rather than cross-sectional information. We have developed computer methods to display a slice at arbitrary orientation through the three-dimensional object. The...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-197701000-00018

    authors: Herman GT,Liu HK

    更新日期:1977-01-01 00:00:00

  • MRI of meniscal allografts.

    abstract:OBJECTIVE:To illustrate the techniques and the MRI appearance of meniscal transplants. MATERIALS AND METHODS:Three patients underwent MRI of the knee between 2 weeks and 14 months after meniscal transplantation. RESULTS:Although postoperative artifacts were present, in all three patients the position, signal intensit...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-199503000-00015

    authors: Patten RM,Rolfe BA

    更新日期:1995-03-01 00:00:00

  • Development and validation of a practical lower-dose-simulation tool for optimizing computed tomography scan protocols.

    abstract:OBJECTIVE:The objective of this study was to develop and validate a novel noise insertion method that can accurately simulate lower-dose images from existing standard-dose computed tomography (CT) data. METHODS:The noise insertion method incorporates the effects of the bowtie filter, automatic exposure control, and el...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0b013e318258e891

    authors: Yu L,Shiung M,Jondal D,McCollough CH

    更新日期:2012-07-01 00:00:00

  • Long-term follow-up of hepatitis using computed tomography.

    abstract::Computed tomography of the liver was performed on two patients with subacute hepatitis. The CT findings included the presence of multiple regenerative nodules in the atrophied liver, shown by decreased CT attenuation. Complications due to hepatitis, such as massive ascites and splenomegaly, were also observed. The CT ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198907000-00016

    authors: Ishikawa N,Nakagawa S,Hirata K,Takizawa Y,Hayashi S,Obara T,Ishikawa T

    更新日期:1989-07-01 00:00:00

  • MR imaging of pontine and extrapontine myelinolysis.

    abstract::Two cases of pontine and extrapontine myelinolysis following electrolyte derangements are presented. One case showed only extrapontine myelinolytic lesions on magnetic resonance (MR) imaging, although both pontine and extrapontine myelinolysis were confirmed at postmortem. Another case made full recovery clinically wi...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198805010-00018

    authors: Moriwaka F,Tashiro K,Maruo Y,Nomura M,Hamada K,Kashiwaba T

    更新日期:1988-05-01 00:00:00

  • Observations on CT differentiation of pleural and peritoneal fluid.

    abstract::Distinguishing juxtadiaphragmatic pleural and peritoneal fluid by computed tomography (CT) is sometimes difficult. We evaluated the distribution of fluid in 50 consecutive patients with pleural effusion or ascites or both. Juxtadiaphragmatic pleural fluid was nearly always found posteromedially, whereas peritoneal flu...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198402000-00005

    authors: Griffin DJ,Gross BH,McCracken S,Glazer GM

    更新日期:1984-02-01 00:00:00

  • Value of dynamic enhanced magnetic resonance imaging for distinguishing between ovarian fibroma and subserous uterine leiomyoma.

    abstract:PURPOSE:The purpose of this study was to assess the accuracy of magnetic resonance imaging (MRI), particularly, dynamic MRI, in distinguishing ovarian fibromas from subserous uterine leiomyomas. MATERIAL AND METHODS:Fifteen ovarian fibromas and 15 subserous uterine leiomyomas were retrospectively reviewed. All MR exam...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/01.rct.0000237810.88251.9e

    authors: Thomassin-Naggara I,Daraï E,Nassar-Slaba J,Cortez A,Marsault C,Bazot M

    更新日期:2007-03-01 00:00:00

  • A comprehensive electrocardiogram-gated 64-slice multidetector computed tomography imaging protocol to visualize the coronary arteries, thoracic aorta, and pulmonary vasculature in a single breath hold.

    abstract:OBJECTIVES:Advances in computed tomography technology may permit the evaluation of coronary disease, aortic dissection, and pulmonary embolism with a single contrast bolus and breath hold. We sought to determine whether 64-slice computed tomography angiography (CTA) allows for simultaneous visualization of the coronary...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0b013e31817c12b1

    authors: Shapiro MD,Dodd JD,Kalva S,Wittram C,Hsu J,Nasir K,Liu B,Nagurney JT,Kalra MK,Nichols JH,Cury RC,Abbara S,Tawakol A,Brady TJ,Hoffmann U

    更新日期:2009-03-01 00:00:00

  • Rotating conventional gamma camera single-photon tomographic system: physical characterization.

    abstract::A whole-body single-photon emission computed tomography system has been evaluated in terms of its physical performance. It consists of a standard GE 400 T maxi camera rotating on a ring stand, coupled to an Informatek Simis 3 computer system. In its standard mode of operation, 64 or 128 successive views of 64 X 64 or ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198108000-00017

    authors: Soussaline FP,Todd-Popkropek AE,Zurowski S,Huffer E,Raynaud CE,Kellershohn CL

    更新日期:1981-08-01 00:00:00

  • CT diagnosis of dorsal pancreas agenesis.

    abstract::We report a case of agenesis of dorsal pancreas diagnosed by CT. This anomaly can easily be confused with pancreas divisum on endoscopic retrograde cholangiopancreatography alone. ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198701000-00038

    authors: Shah KK,DeRidder PH,Schwab RE,Alexander TJ

    更新日期:1987-01-01 00:00:00

  • The effect of the section thickness used for 2- and 3-dimensional quantification of dual-energy perfusion computed tomography.

    abstract:PURPOSE:To retrospectively investigate the effect of the section thickness used for quantifying dual-energy perfusion computed tomography (DEpCT) during 2- and 3-dimensional evaluation. METHODS:Sixty-six patients (22 males and 44 females; mean age, 59.3 years) suspected of having an acute pulmonary embolism underwent ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0000000000000148

    authors: Nomura T,Okada M,Nakashima Y,Yonezawa T,Kudomi S,Kido S,Matsunaga N

    更新日期:2014-11-01 00:00:00

  • Predicting Neoadjuvant Chemotherapy in Nonconcentric Shrinkage Pattern of Breast Cancer Using 1H-Magnetic Resonance Spectroscopic Imaging.

    abstract:OBJECTIVE:The aim of this study was to explore the response to neoadjuvant chemotherapy (NAC) in nonconcentric shrinkage pattern of breast cancer (BC) patients using H-magnetic resonance spectroscopy. METHODS:Twenty-five BC patients were the study cohort. All patients received AT-based regimen as first-line treatment....

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0000000000000647

    authors: Zhou J,Qiao PG,Zhang HT,Li GJ,Jiang ZF

    更新日期:2018-01-01 00:00:00

  • 64 multidetector-row computed tomography for preoperative evaluation of gastric cancer: histological correlation.

    abstract:OBJECTIVE:To assess the accuracy of 64 multidetector-row computed tomography (MDCT) in the diagnosis and staging of gastric cancer. METHODS:This study was approved by the institutional review board, and the patients involved gave informed consent. Forty-four patients (34 men and 10 women; mean age, 57 years) with gast...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/01.rct.0000234072.16209.ab

    authors: Yang DM,Kim HC,Jin W,Ryu CW,Kang JH,Park CH,Kim HS,Jung DH

    更新日期:2007-01-01 00:00:00

  • Accuracy of object depiction and opacity transfer function optimization in CT volume-rendered images.

    abstract::Volume rendering is a visualization technique that has important applications in diagnostic radiology and radiotherapy. A methodology is presented for (a) evaluation of the quantitative accuracy of representation of known objects in volume-rendered scenes and for (b) optimization of the opacity transfer function to ac...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-199805000-00020

    authors: Jani AB,Pelizzari CA,Chen GT,Grzeszczuk RP

    更新日期:1998-05-01 00:00:00

  • Rare benign and malignant appendiceal lesions: spectrum of computed tomography findings with pathologic correlation.

    abstract::Although acute appendicitis is the most common disease of the appendix, the appendix can be involved by a wide range of diseases. Diseases other than acute appendicitis may produce signs and symptoms indistinguishable from those of acute appendicitis. Computed tomography (CT) can provide important information for diag...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章,评审

    doi:10.1097/00004728-200305000-00001

    authors: Chiou YY,Pitman MB,Hahn PF,Kim YH,Rhea JT,Mueller PR

    更新日期:2003-05-01 00:00:00

  • MR depiction of zonal anatomy of the prostate at 1.5 T.

    abstract::Previous reports of magnetic resonance imaging of the prostate have described a homogeneous appearance to the normal prostate gland. The T2-weighted images of the normal prostate obtained at higher field strength (1.5 T) reveal an inhomogeneous appearance of the normal gland, with apparent differentiation of normal pr...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198611000-00017

    authors: Sommer FG,McNeal JE,Carrol CL

    更新日期:1986-11-01 00:00:00

  • High resolution MRI of the deep gray nuclei at 8 Tesla.

    abstract:PURPOSE:High resolution MR images obtained from a normal human volunteer at 8 T are utilized to describe the appearance of iron-containing deep gray nuclei at this field strength. METHOD:High resolution (1,024 x 1,024 matrix) near-axial gradient echo images of the deep gray nuclei were acquired on a human volunteer by...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-199911000-00009

    authors: Bourekas EC,Christoforidis GA,Abduljalil AM,Kangarlu A,Chakeres DW,Spigos DG,Robitaille PM

    更新日期:1999-11-01 00:00:00

  • Detection of thyroid pyramidal lobe by ultrasound versus computed tomography: a single-center study.

    abstract:OBJECTIVE:The prevalence and features of the thyroid pyramidal lobe (TPL) on computed tomography (CT) have been reported, but no ultrasound (US) study has been found. The purposes of the current study were to assess the sonographic prevalence and features of TPLs and to compare the US and CT parameters of TPLs. METHOD...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0000000000000054

    authors: Kim KS,Kim DW,Sung JY

    更新日期:2014-05-01 00:00:00

  • Deep-frozen biologic phantom for performance evaluation of CT scanners.

    abstract::A test method with use of a biologic phantom--a deep-frozen specimen of a human cadaver--was developed in an attempt to simulate the clinical setting in CT of the spine. The quality of both soft tissue and bone images in the absence of motion artifacts was evaluated for seven scanner models. Special attention was paid...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198611000-00023

    authors: Moström U,Bergström K,Pech P,Ytterbergh C

    更新日期:1986-11-01 00:00:00