MR image-guided endovascular procedures with the ultrasmall superparamagnetic iron oxide SH U 555 C as an intravascular contrast agent: study in pigs.

Abstract:

PURPOSE:To evaluate the feasibility of using the ultrasmall superparamagnetic iron oxide (USPIO) SH U 555 C as an intravascular contrast agent for magnetic resonance (MR) image-guided vascular procedures with an open MR imaging system. MATERIALS AND METHODS:All experiments were performed with MR imaging at 0.2 T. MR image-guided interventions were performed in USPIO-enhanced vessels in four pigs. With near real-time MR image guidance (acquisition time, 0.64 second per section), the splenic and renal arteries were consecutively catheterized by using a susceptibility artifact-based catheter-guide wire combination. Angioplasty and stent implantation were performed four times in the renal artery and twice in the iliac artery. Intraaortal signal intensity (SI) was measured during the interventions. RESULTS:After administration of SH U 555 C (40 micromol of iron per kilogram of body weight), a three-dimensional MR angiographic sequence was performed that allowed visualization of the abdominal and pelvic vessels that were as small as 2 mm in diameter. Catheterization, angioplasty, and stent implantation were successfully guided in the USPIO-enhanced vasculature. Sixty minutes after contrast agent injection, the mean aortic SI was 70% of the maximum measured enhancement levels. CONCLUSION:One intravenous injection of SH U 555 C enabled long, continuous intravascular SI enhancement at MR angiography, and, in combination with susceptibility artifact-based device tracking, the injection allowed the performance of MR imaging-guided intravascular interventions in an open MR imaging system.

journal_name

Radiology

journal_title

Radiology

authors

Wacker FK,Reither K,Ebert W,Wendt M,Lewin JS,Wolf KJ

doi

10.1148/radiol.2262011815

subject

Has Abstract

pub_date

2003-02-01 00:00:00

pages

459-64

issue

2

eissn

0033-8419

issn

1527-1315

journal_volume

226

pub_type

杂志文章
  • Focal hepatic masses: comparison of detection during arterial portography with MR imaging and CT.

    abstract:PURPOSE:A prospective study was performed to compare the sensitivity and specificity of magnetic resonance (MR) imaging and computed tomography (CT) both performed during arterial portography in depicting focal hepatic masses. MATERIALS AND METHODS:Eleven patients with 31 pathologically proved focal hepatic masses wer...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.190.3.8115620

    authors: Soyer P,Laissy JP,Sibert A,Blanc F,Belghiti J,Marmuse JP,Zeitoun G,Levesque M,Menu Y

    更新日期:1994-03-01 00:00:00

  • Waldenström macroglobulinemia: MR imaging of the spine and CT of the abdomen and pelvis.

    abstract::Twenty-three consecutive patients with Waldenström macroglobulinemia were studied with magnetic resonance (MR) imaging of the spine and computed tomography (CT) of the abdomen and pelvis. MR imaging studies included sagittal T1-weighted and gradient-recalled-echo sequences performed with and without contrast material ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.188.3.8351330

    authors: Moulopoulos LA,Dimopoulos MA,Varma DG,Manning JT,Johnston DA,Leeds NE,Libshitz HI

    更新日期:1993-09-01 00:00:00

  • Liver SULmean at FDG PET/CT: interreader agreement and impact of placement of volume of interest.

    abstract:PURPOSE:To evaluate how interreader agreement and the site of the volume of interest (VOI) affect the agreement and variability of liver mean standardized uptake value normalized to lean body mass (SUL(mean)) at fluorine 18 fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT). MATERIALS...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.12121385

    authors: Viner M,Mercier G,Hao F,Malladi A,Subramaniam RM

    更新日期:2013-05-01 00:00:00

  • A calcified adenocarcinoma of the lung with very high CT numbers.

    abstract::A case is reported of a man with a solitary pulmonary nodule that had an average CT number of 366 HU. Biopsy of the lesion demonstrated a primary adenocarcinoma of the lung with diffuse calcification. It is concluded that high CT numbers of solitary nodules do not ensure a benign lesion. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.150.3.6695080

    authors: Goldstein MS,Rush M,Johnson P,Sprung CL

    更新日期:1984-03-01 00:00:00

  • F-18 fluorodeoxyglucose PET in vivo evaluation of pancreatic glucose metabolism for detection of pancreatic cancer.

    abstract:PURPOSE:To evaluate positron emission tomography (PET) with fluorine-18-labeled fluorodeoxyglucose (FDG) for detection of pancreatic cancer compared with computed tomography (CT) and ultrasonography (US). MATERIALS AND METHODS:Forty patients with suspected pancreatic cancer underwent static PET after intravenous injec...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.192.1.8208970

    authors: Bares R,Klever P,Hauptmann S,Hellwig D,Fass J,Cremerius U,Schumpelick V,Mittermayer C,Büll U

    更新日期:1994-07-01 00:00:00

  • Subtraction radiography: techniques and limitations.

    abstract::Subtraction radiography permits the use of 7-10 times less contrast material than is required without subtraction techniques. The first-order, second-order, and composite mask techniques are described and evaluated. While the second-order technique gives more complete cancellation of common structures, the more common...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/124.1.65

    authors: Ort MG,Gregg EC,Kaufman B

    更新日期:1977-07-01 00:00:00

  • Blood flow vortices along the main pulmonary artery measured with MR imaging for diagnosis of pulmonary hypertension.

    abstract:PURPOSE:To approximate the functional relationship between invasively measured mean pulmonary arterial pressure (mPAP) and the phase-contrast magnetic resonance (MR) imaging-derived duration of vortical blood flow along the main pulmonary artery and to analyze its applicability for noninvasive diagnosis of pulmonary hy...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.14140849

    authors: Reiter G,Reiter U,Kovacs G,Olschewski H,Fuchsjäger M

    更新日期:2015-04-01 00:00:00

  • Modification of a serial film changer for frontal magnification angiography.

    abstract::A movable carriage was designed and built for a Franklin film changer to facilitate routine serial 2 times magnification. This simple device permits magnification angiography without major equipment purchases or room alterations. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/117.2.481a

    authors: Spitzer RM,Olsson HE,Gibson BJ

    更新日期:1975-11-01 00:00:00

  • Preeclampsia-eclampsia: clinical and neuroradiographic correlates and insights into the pathogenesis of hypertensive encephalopathy.

    abstract:PURPOSE:To investigate the clinical parameters that are associated with the development of brain edema of hypertensive encephalopathy in patients with preeclampsia-eclampsia. MATERIALS AND METHODS:Twenty-eight patients with preeclampsia-eclampsia and neurologic symptoms underwent magnetic resonance (MR) imaging. Clini...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.217.2.r00nv44371

    authors: Schwartz RB,Feske SK,Polak JF,DeGirolami U,Iaia A,Beckner KM,Bravo SM,Klufas RA,Chai RY,Repke JT

    更新日期:2000-11-01 00:00:00

  • Distal radioulnar joint arthrography: simplified technique.

    abstract::Three-compartment arthrography has been advocated in the current literature for evaluation of the intrinsic ligaments of the wrist. Previous techniques for distal radioulnar joint (DRUJ) injection introduce the needle directly into the joint space. As is done in shoulder arthrography, however, the needle tip can be po...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.199.1.8633160

    authors: Lomasney LM,Cooper RA

    更新日期:1996-04-01 00:00:00

  • Imaging of the gallbladder, 1987.

    abstract::Gallbladder disease, and the patients with symptoms suggestive of gallbladder disease, remains a widespread clinical problem that requires investigation by imaging techniques. Sonography, and to a lesser extent cholescintigraphy, has facilitated the evaluation of these patients and allows the diagnosis of cholelithias...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.163.3.3554340

    authors: Cooperberg PL,Gibney RG

    更新日期:1987-06-01 00:00:00

  • Effects of a program to train radiologic technologists to identify abnormalities on mammograms.

    abstract:PURPOSE:To assess whether radiologic technologists could be successfully trained to identify abnormalities on mammograms. MATERIALS AND METHODS:Eight radiologic technologists from two different institutions took a pretest, underwent an 8-hour training course followed by a period of preceptorship, and then took a postt...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.194.1.7997550

    authors: Bassett LW,Hollatz-Brown AJ,Bastani R,Pearce JG,Hirji K,Chen L

    更新日期:1995-01-01 00:00:00

  • Complications of cesarean section: role of transperineal US.

    abstract::The pelvic area was prospectively examined with transabdominal and transperineal ultrasonography (US) in 22 patients referred for US evaluation for possible complications of cesarean section. The region of the uterine wound was seen with transabdominal US in all patients and with transperineal US in 20. The two in who...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.188.2.8327710

    authors: Hertzberg BS,Bowie JD,Kliewer MA

    更新日期:1993-08-01 00:00:00

  • Acute rat lung injury: feasibility of assessment with micro-CT.

    abstract:PURPOSE:To evaluate the feasibility of micro-computed tomography (CT) for analysis of the lung fine structure and its alterations during endotoxin-induced lung injury. MATERIALS AND METHODS:Intravital perfusion-fixed rat lungs with (n = 5) and without (n = 5) endotoxin perfusion were scanned with micro-CT. Three imagi...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2331031340

    authors: Langheinrich AC,Leithäuser B,Greschus S,Von Gerlach S,Breithecker A,Matthias FR,Rau WS,Bohle RM

    更新日期:2004-10-01 00:00:00

  • Percutaneous gastrostomy in a child.

    abstract::A 2-year-old girl with cyanotic congenital heart disease needed to undergo gastrostomy. To avoid the use of general anesthesia, a percutaneous gastrostomy was performed as an interventional radiologic procedure with the patient under sedation and with the use of local anesthesia. The placement of a nasogastrocutaneous...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.160.1.3715040

    authors: Keller MS,Lai S,Wagner DK

    更新日期:1986-07-01 00:00:00

  • The ultrasonic features of hypertrophic pyloric stenosis, with emphasis on the postoperative appearance.

    abstract::Six patients were examined with high-resolution real-time ultrasound following Rammstedt pyloromyotomy for hypertrophic pyloric stenosis. At surgery, the pyloric muscle thickness was greater than or equal to 4 mm, diameter greater than or equal to 13 mm, and length greater than or equal to 19 mm. Sequential sonograms ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.147.2.6836130

    authors: Sauerbrei EE,Paloschi GG

    更新日期:1983-05-01 00:00:00

  • Mn-DPDP in MR imaging of pancreatic adenocarcinoma: initial clinical experience.

    abstract::Manganese (II) N,N'-dipyridoxylethylenediamine-N,N'-diacetate 5,5'-bis(phosphate) (DPDP) was tested as a contrast agent for magnetic resonance imaging of pancreatic adenocarcinoma in 15 patients. At enhanced T1-weighted spin-echo (SE) and enhanced T1-weighted gradient-echo (GRE) imaging, statistically significant incr...

    journal_title:Radiology

    pub_type: 临床试验,杂志文章

    doi:10.1148/radiology.186.3.8430190

    authors: Gehl HB,Urhahn R,Bohndorf K,Klever P,Hauptmann S,Lodemann KP,Matern S,Schumpelick V,Günther RW

    更新日期:1993-03-01 00:00:00

  • Endoscopic ultrasonic evaluation of the prostate using a transrectal probe: prospective evaluation and acoustic characterization.

    abstract::Transrectal sonography of the normal prostate demonstrates a gland that has low-level homogeneous echoes. Benign and malignant prostatic disease causes disruption of this normal texture. A prospective study was performed to determine the ability of ultrasound to detect focal defects accurately. The specific histologic...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.149.1.6193560

    authors: Rifkin MD,Kurtz AB,Choi HY,Goldberg BB

    更新日期:1983-10-01 00:00:00

  • Spermatic vein embolization with hot contrast material: fertility results.

    abstract::Spermatic venography with hot contrast material embolization was undertaken in 81 patients with varicoceles and infertility. Long-term follow-up information was available in 91% of the patients, and there was an overall conception rate of 40.5%. Embolization with hot contrast material was easily performed without spec...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.168.1.3380950

    authors: Smith TP,Hunter DW,Cragg AH,Darcy MD,Castaneda-Zuniga WR,Sinclair TR,Ercole C,Hulbert JC,Kaye KW,Amplatz K

    更新日期:1988-07-01 00:00:00

  • Radiologic features of inferior pulmonary ligament air collections in neonates with respiratory distress.

    abstract::Radiologically characteristic extra-alveolar air collections in one or both inferior pulmonary ligaments developed in 14 neonates with respiratory distress on assisted ventilation. Eleven infants had radiographically visible pulmonary interstitial emphysema prior to or concurrent with the air collections. All infants ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/130.2.357

    authors: Volberg FM Jr,Everett CJ,Brill PW

    更新日期:1979-02-01 00:00:00

  • Peritoneocele: visualization with defecography and peritoneography performed simultaneously.

    abstract:PURPOSE:To evaluate the use of simultaneous defecography and peritoneography (defecoperitoneography) in patients with an unexplained widening of the rectovaginal space noted at defecography. MATERIALS AND METHODS:Twenty-two patients with unexplained widening of the rectovaginal space noted at defecography were studied...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.202.2.9015060

    authors: Bremmer S,Mellgren A,Holmström B,López A,Udén R

    更新日期:1997-02-01 00:00:00

  • Introducing the "golden oldies" of radiology.

    abstract::Online supplemental material is available for this article. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.14142264

    authors: Kressel HY,Levine D

    更新日期:2015-01-01 00:00:00

  • Relationship between Overall Survival of Patients with Non-Small Cell Lung Cancer and Whole-Body Metabolic Tumor Burden Seen on Postsurgical Fluorodeoxyglucose PET Images.

    abstract:PURPOSE:To test the hypothesis that whole-body metabolic tumor burden (MTBWB) on postsurgical fluorodeoxyglucose (FDG) positron emission tomographic (PET)/computed tomographic (CT) images in patients with non-small cell lung cancer (NSCLC) is associated with their overall survival (OS). MATERIALS AND METHODS:The insti...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.14141398

    authors: Zhang C,Liao C,Penney BC,Appelbaum DE,Simon CA,Pu Y

    更新日期:2015-06-01 00:00:00

  • Intimal fibromuscular dysplasia and Takayasu arteritis: delayed response to percutaneous transluminal renal angioplasty.

    abstract::Percutaneous transluminal renal angioplasty has been shown to be an effective technique to dilate renal artery lesions, particularly those due to fibromuscular dysplasia. However, four of 70 patients in this study experienced atypical responses to angioplasty. Their lesions initially resisted dilation and had incomple...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.157.3.2865770

    authors: Srur MF,Sos TA,Saddekni S,Cohn DJ,Rozenblit G,Wetter EB

    更新日期:1985-12-01 00:00:00

  • Benign hyperplastic nodules that originate in the peripheral zone of the prostate gland.

    abstract:PURPOSE:To describe a benign nodular lesion in the peripheral zone (PZ) of the prostate gland. MATERIALS AND METHODS:In 1,087 patients, the features of 722 focal lesions in the PZ or central zone of the prostate on transrectal ultrasound (TRUS) scans were retrospectively compared with histologic findings in biopsy sam...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.189.3.7694310

    authors: Oyen RH,Van de Voorde WM,Van Poppel HP,Brys PP,Ameye FE,Franssens YM,Baert AL,Baert LV

    更新日期:1993-12-01 00:00:00

  • Improving Image Quality and Reducing Radiation Dose for Pediatric CT by Using Deep Learning Reconstruction.

    abstract::Background CT deep learning reconstruction (DLR) algorithms have been developed to remove image noise. How the DLR affects image quality and radiation dose reduction has yet to be fully investigated. Purpose To investigate a DLR algorithm's dose reduction and image quality improvement for pediatric CT. Materials and M...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2020202317

    authors: Brady SL,Trout AT,Somasundaram E,Anton CG,Li Y,Dillman JR

    更新日期:2021-01-01 00:00:00

  • Aneurysm clips: evaluation of MR imaging artifacts at 1.5 T.

    abstract::Magnetic resonance (MR) imaging-related artifacts associated with five different aneurysm clips made of five different metals (commercially pure titanium, titanium alloy, Phynox, Elgiloy, and cobalt alloy) were evaluated. Aneurysm clips made of commercially pure titanium and titanium alloy produced the smallest artifa...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.209.2.9807590

    authors: Shellock FG,Kanal E

    更新日期:1998-11-01 00:00:00

  • Computer-aided detection in full-field digital mammography: sensitivity and reproducibility in serial examinations.

    abstract:PURPOSE:To retrospectively evaluate the sensitivity and reproducibility of a computer-aided detection (CAD) system applied to serial digital mammograms obtained in women with breast cancer, with histologic analysis as the reference standard. MATERIALS AND METHODS:This study was institutional review board approved, and...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2461062072

    authors: Kim SJ,Moon WK,Cho N,Cha JH,Kim SM,Im JG

    更新日期:2008-01-01 00:00:00

  • Lateral arcuate ligaments of the diaphragm: anatomic variations at abdominal CT.

    abstract::The authors have occasionally observed nodular areas abutting the lateral diaphragmatic surface and extending into the posterior pararenal space on computed tomographic (CT) scans. Review of the anatomy literature revealed that this finding represents inferolateral extension of the lateral arcuate ligaments, which ref...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.185.1.1523290

    authors: Silverman PM,Cooper C,Zeman RK

    更新日期:1992-10-01 00:00:00

  • B-cell non-Hodgkin lymphoma: PET/CT evaluation after 90Y-ibritumomab tiuxetan radioimmunotherapy--initial experience.

    abstract:PURPOSE:To retrospectively compare fusion fluorine 18 fluorodeoxyglucose (FDG) positron emission tomographic (PET)/computed tomographic (CT) imaging with CT imaging alone in the evaluation of yttrium 90 ((90)Y)-ibritumomab tiuxetan radioimmunotherapy treatment of B-cell non-Hodgkin lymphoma. MATERIALS AND METHODS:This...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2463060588

    authors: Ulaner GA,Colletti PM,Conti PS

    更新日期:2008-03-01 00:00:00