Combined hepatocellular-cholangiocarcinoma: can we use contrast-enhanced ultrasound Liver Imaging Reporting and Data System (LI-RADS) to predict the patient's survival?

Abstract:

OBJECTIVES:To evaluate the relationship between contrast-enhanced (CE) ultrasound Liver Reporting and Data System (LI-RADS) classification of combined hepatocellular-cholangiocarcinoma (cHCC-CCA) and their histopathological component predominance, and to determine if the CEUS LI-RADS category can be used to predict the patient's survival after surgical resection. METHODS:Between January 2011 and December 2018, medical records and CEUS of patients with pathologically proven cHCC-CCA were studied. The predominance of hepatocellular carcinoma (HCC)/intrahepatic cholangiocarcinoma (ICC) component of cHCC-CCA was analyzed by histopathology. The proportion of HCC-predominant cHCC-CCA in different LI-RADS category was compared by using Fisher's exact test. Factors affecting tumor recurrence were analyzed by Cox proportional hazard model. Disease-free survival (DFS) was estimated by using Kaplan-Meier survival curve and compared by log-rank test. RESULTS:The study included 37 cHCC-CCA patients (33 men, 4 women; average age, 50.4 ± 11.0 years) and 37 nodules (mean diameter, 6.1 ± 3.9 cm). According to CEUS LI-RADS, 62.2% (23/37), 18.9% (7/37), and 18.9% (7/37) of cHCC-CCA were classified as LR-M, LR-5, and LR-TIV, respectively. The ratio of HCC predominance in LR-5 was 100% (10/10) vs 81.5% (22/27) in the LR-M group (p = 0.591). In our population, LR-5 patients had longer DFS than LR-M and LR-TIV patients combined (median DFS: 18.0 vs 6.4 months, p = 0.016). Multiple lesions (hazard ratio, 3.1; p = 0.007), tumor size (≥ 5 cm, hazard ratio, 4.1; p = 0.003), and CEUS LI-RADS category (LR-M and LR-TIV, hazard ratio, 4.7; p = 0.011) showed independent association with shorter DFS. CONCLUSION:cHCC-CCA characterized as LR-5 on CEUS tend to represent HCC-predominant tumors with significantly longer disease-free survival compared to cHCC-CCA categorized as LR-M and LR-TIV. KEY POINTS:• By using the American College of Radiology contrast-enhanced ultrasound Liver Imaging Reporting and Data System (CEUS LI-RADS), majority (30/37, 81.1%) of cHCC-CCA tumors were classified as LR-M or LR-TIV and only 18.9% (7/30) of cHCC-CCA were categorized as LR-5. • Patients with CEUS LR-5 cHCC-CCA had statistically significant longer disease-free time than those with LR-M and TIV cHCC-CCA (median DFS: 18.0 vs 6.4 months, p = 0.016). • Multiple lesions (hazard ratio, 3.1; p = 0.007), tumor size (≥ 5 cm, hazard ratio, 4.1; p = 0.003), and CEUS LI-RADS category (LR-M and LR-TIV, hazard ratio, 4.7; p = 0.011) showed independent association with shorter DFS.

journal_name

Eur Radiol

journal_title

European radiology

authors

Yang J,Huang JY,Chen X,Ling WW,Luo Y,Shi YJ,Liu JB,Lu Q,Lyshchik A

doi

10.1007/s00330-020-07656-1

subject

Has Abstract

pub_date

2021-01-25 00:00:00

eissn

0938-7994

issn

1432-1084

pii

10.1007/s00330-020-07656-1

pub_type

杂志文章
  • Detection of left atrial thrombus in patients with mitral stenosis and atrial fibrillation: retrospective comparison of two-phase computed tomography, transoesophageal echocardiography and surgical findings.

    abstract:OBJECTIVE:This retrospective study aims to assess the accuracy of two-phase computed tomography (CT) and transoesophageal echocardiography (TEE) for the detection of left atrial (LA) thrombus in patients with mitral stenosis (MS) and atrial fibrillation (AF), by using intraoperative findings as the reference standard. ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-013-2944-5

    authors: Choi BH,Ko SM,Hwang HK,Song MG,Shin JK,Kang WS,Kim TY

    更新日期:2013-11-01 00:00:00

  • Preliminary clinical experience with a dedicated interventional robotic system for CT-guided biopsies of lung lesions: a comparison with the conventional manual technique.

    abstract:OBJECTIVE:Evaluate the performance of a robotic system for CT-guided lung biopsy in comparison to the conventional manual technique. MATERIALS AND METHODS:One hundred patients referred for CT-guided lung biopsy were randomly assigned to group A (robot-assisted procedure) or group B (conventional procedure). Size, dist...

    journal_title:European radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s00330-014-3508-z

    authors: Anzidei M,Argirò R,Porfiri A,Boni F,Anile M,Zaccagna F,Vitolo D,Saba L,Napoli A,Leonardi A,Longo F,Venuta F,Bezzi M,Catalano C

    更新日期:2015-05-01 00:00:00

  • Value of abdominal CT in the emergency department for patients with abdominal pain.

    abstract::The purpose of our study is to demonstrate the value of CT in the emergency department (ED) for patients with non-traumatic abdominal pain. Between August 1998 and April 1999, 536 consecutive patients with non-traumatic abdominal pain were entered into our study. Using a computer order entry system, physicians were as...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1715-5

    authors: Rosen MP,Siewert B,Sands DZ,Bromberg R,Edlow J,Raptopoulos V

    更新日期:2003-02-01 00:00:00

  • 2D and 3D T2-weighted MR sequences for the assessment of neurovascular bundle changes after nerve-sparing radical retropubic prostatectomy with erectile function correlation.

    abstract::The aim of this study was to assess the capability of a 3D isotropic MRI T2-weighted sequence (3D T2 ISO) in the depiction of changes of neurovascular bundles (NVBs) after bilateral nerve-sparing radical retropubic prostatectomy (RRP). Furthermore, our aim was also to introduce a new MRI classification score of the NV...

    journal_title:European radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s00330-008-1102-y

    authors: Panebianco V,Sciarra A,Osimani M,Lisi D,Ciccariello M,Salciccia S,Gentile V,Di Silverio F,Passariello R

    更新日期:2009-01-01 00:00:00

  • Development of automatic measurement for patellar height based on deep learning and knee radiographs.

    abstract:OBJECTIVES:To develop and evaluate the performance of a deep learning-based system for automatic patellar height measurements using knee radiographs. METHODS:The deep learning-based algorithm was developed with a data set consisting of 1018 left knee radiographs for the prediction of patellar height parameters, specif...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-06856-z

    authors: Ye Q,Shen Q,Yang W,Huang S,Jiang Z,He L,Gong X

    更新日期:2020-09-01 00:00:00

  • Association of "initial CT" findings with mortality in older patients with coronavirus disease 2019 (COVID-19).

    abstract:OBJECTIVES:To investigate the association of chest CT findings with mortality in clinical management of older patients. METHODS:From January 21 to February 14, 2020, 98 older patients (≥ 60 years) who had undergone chest CT scans ("initial CT") on admission were enrolled. Manifestation and CT score were compared betwe...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-06969-5

    authors: Li Y,Yang Z,Ai T,Wu S,Xia L

    更新日期:2020-11-01 00:00:00

  • Impact of sublingual nitroglycerin dosage on FFRCT assessment and coronary luminal volume-to-myocardial mass ratio.

    abstract:OBJECTIVES:Fractional flow reserve computed tomography (FFRCT) depends upon nitroglycerin (NTG) inducing maximal hyperemia. However, the impact of NTG dosages on FFRCT analysis including coronary volume-to-mass ratio (V/M) is unknown. METHODS:Eighty patients with repeat coronary CT angiograms (CCTAs) with different su...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-019-06293-7

    authors: Holmes KR,Fonte TA,Weir-McCall J,Anastasius M,Blanke P,Payne GW,Ellis J,Murphy DT,Taylor C,Leipsic JA,Sellers SL

    更新日期:2019-12-01 00:00:00

  • Musculoskeletal imaging with a prototype photon-counting detector.

    abstract:OBJECTIVE:To test a digital imaging X-ray device based on the direct capture of X-ray photons with pixel detectors, which are coupled with photon-counting readout electronics. METHODS:The chip consists of a matrix of 256 × 256 pixels with a pixel pitch of 55 μm. A monolithic image of 11.2 cm × 7 cm was obtained by the...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-011-2246-8

    authors: Gruber M,Homolka P,Chmeissani M,Uffmann M,Pretterklieber M,Kainberger F

    更新日期:2012-01-01 00:00:00

  • Hypodense liver lesions in patients with hepatic steatosis: do we profit from dual-energy computed tomography?

    abstract:PURPOSE:To evaluate dual-energy CT (DECT) imaging of hypodense liver lesions in patients with hepatic steatosis, having a high incidence in the general population and among cancer patients receiving chemotherapy. METHODS:One hundred and five patients with hepatic steatosis (liver parenchyma <40 HU) underwent contrast-...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-3772-6

    authors: Nattenmüller J,Hosch W,Nguyen TT,Skornitzke S,Jöres A,Grenacher L,Kauczor HU,Sommer CM,Stiller W

    更新日期:2015-12-01 00:00:00

  • Imaging of tuberculous disease involving breast.

    abstract::The aim of our study was to evaluate radiologic findings of the tuberculosis involving breast. We evaluated the radiologic features of 17 patients (18 lesions) with tuberculous disease involving the breast. The radiologic examinations, including mammography (16 patients), ultrasonography (12 patients), and Gd-DTPA-enh...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050578

    authors: Oh KK,Kim JH,Kook SH

    更新日期:1998-01-01 00:00:00

  • Prospective validation of the ultrasound based TIRADS (Thyroid Imaging Reporting And Data System) classification: results in surgically resected thyroid nodules.

    abstract:OBJECTIVE:To assess performance of TIRADS classification on a prospective surgical cohort, demonstrating its clinical usefulness. METHODS:Between June 2009 and October 2012, patients assessed with pre-operative ultrasound (US) were included in this IRB-approved study. Nodules were categorised according to our previous...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4605-y

    authors: Horvath E,Silva CF,Majlis S,Rodriguez I,Skoknic V,Castro A,Rojas H,Niedmann JP,Madrid A,Capdeville F,Whittle C,Rossi R,Domínguez M,Tala H

    更新日期:2017-06-01 00:00:00

  • The role of Size-Specific Dose Estimate (SSDE) in patient-specific organ dose and cancer risk estimation in paediatric chest and abdominopelvic CT examinations.

    abstract:OBJECTIVES:To develop a clinically applicable method to estimate patient-specific organ and blood doses and lifetime attributable risks (LAR) from paediatric torso CT examinations. METHODS:Individualized voxel models were created from full-body CT data of 10 paediatric patients (2-18 years). Patient-specific dose dist...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-4091-7

    authors: Franck C,Vandevoorde C,Goethals I,Smeets P,Achten E,Verstraete K,Thierens H,Bacher K

    更新日期:2016-08-01 00:00:00

  • Angiomyolipoma (AML) without visible fat: Ultrasound, CT and MR imaging features with pathological correlation.

    abstract:OBJECTIVE:To compare imaging findings with histopathology in AML without visible fat (AMLwvf). MATERIAL AND METHODS:With IRB approval, we identified 18 AMLwvf that underwent CT between 2002-2014. A radiologist measured NECT-attenuation, corticomedullary (CM) and nephrographic (NG) enhancement, echogenicity relative to...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-3851-8

    authors: Hakim SW,Schieda N,Hodgdon T,McInnes MD,Dilauro M,Flood TA

    更新日期:2016-02-01 00:00:00

  • CT dose survey in adults: what sample size for what precision?

    abstract:OBJECTIVES:To determine variability of volume computed tomographic dose index (CTDIvol) and dose-length product (DLP) data, and propose a minimum sample size to achieve an expected precision. METHODS:CTDIvol and DLP values of 19,875 consecutive CT acquisitions of abdomen (7268), thorax (3805), lumbar spine (3161), cer...

    journal_title:European radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s00330-016-4333-3

    authors: Taylor S,Van Muylem A,Howarth N,Gevenois PA,Tack D

    更新日期:2017-01-01 00:00:00

  • CT-guided radiofrequency ablation of spinal osteoid osteomas with concomitant perineural and epidural irrigation for neuroprotection.

    abstract::Here we report our experience of a neuroprotective adaptation of the technique of CT-guided radiofrequency (RF) ablation of spinal osteoid osteomas. Over 9 years seven patients underwent eight CT-guided RF treatments for osteoid osteoma. CT-guided RF ablation was performed with general anaesthesia. The lesion was heat...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-009-1404-8

    authors: Klass D,Marshall T,Toms A

    更新日期:2009-09-01 00:00:00

  • Abnormalities of the airways and lung parenchyma in asthmatics: CT observations in 50 patients and inter- and intraobserver variability.

    abstract::The purpose of the study was to evaluate the CT abnormalities of airways and lung parenchyma in asthmatic patients and to assess inter- and intraobserver variability for these abnormalities. The CT scans of 50 asthmatic patients and 10 healthy volunteers were assessed independently by four independent chest radiologis...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/BF00181147

    authors: Grenier P,Mourey-Gerosa I,Benali K,Brauner MW,Leung AN,Lenoir S,Cordeau MP,Mazoyer B

    更新日期:1996-01-01 00:00:00

  • Characterisation of intra-articular soft tissue tumours and tumour-like lesions.

    abstract::The aim of this study was to describe a new magnetic resonance imaging (MRI) classification system for intra-articular soft tissue tumours based on the morphology of the lesion, with the aim to aid the differential diagnosis. We performed a retrospective review of 52 consecutive patients presenting to a specialist mus...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-006-0381-4

    authors: Adams ME,Saifuddin A

    更新日期:2007-04-01 00:00:00

  • Diagnostic value of MRI in tuberculous meningitis.

    abstract::In this study 15 patients with clinical findings and positive cerebrospinal fluid analyses for tuberculous meningitis were evaluated with magnetic resonance imaging (MRI). Tuberculous meningitis was diagnosed in 11 cases when thick meningeal enhancement was present after intravenous injection of gadolinium diethylenet...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/BF00180618

    authors: Tayfun C,Uçöz T,Taşar M,Ataç K,Oğur,Oztürk T,Yinanç MA

    更新日期:1996-01-01 00:00:00

  • Structural changes induced by antineoplastic therapies: keys to evaluate tumor response to treatment.

    abstract::The criteria to define therapeutic response in oncology are those proposed by Miller, characterized by four response categories (complete response, partial response, no change, progression of disease), and based upon both measurable and non-measurable (and otherwise assessable) morphological parameters in comparison w...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s003300101074

    authors: Ferrozzi F,Tognini G,Pavone P

    更新日期:2002-04-01 00:00:00

  • Computed tomography of acute pulmonary embolism: state-of-the-art.

    abstract::Multidetector computed tomography (CT) plays an important role in the detection, risk stratification and prognosis evaluation of acute pulmonary embolism. This review will discuss the technical improvements for imaging peripheral pulmonary arteries, the methods of assessing pulmonary embolism severity based on CT find...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-015-3679-2

    authors: Zhang LJ,Lu GM,Meinel FG,McQuiston AD,Ravenel JG,Schoepf UJ

    更新日期:2015-09-01 00:00:00

  • Two-dimensional and three-dimensional oxygen mapping by 3He-MRI validation in a lung phantom.

    abstract::The aim of this study was to validate oxygen-sensitive 3He-MRI in noninvasive determination of the regional, two- and three-dimensional distribution of oxygen partial pressure. In a gas-filled elastic silicon ventilation bag used as a lung phantom, oxygen sensitive two- and three-dimensional 3He-MRI measurements were ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-005-2778-x

    authors: Gast KK,Schreiber WG,Herweling A,Lehmann F,Erdös G,Schmiedeskamp J,Kauczor HU,Eberle B

    更新日期:2005-09-01 00:00:00

  • Radioembolisation with (90)Y-labelled resin microspheres in the treatment of liver metastasis from breast cancer.

    abstract:OBJECTIVES:Metastatic breast cancer is a heterogeneous disease, commonly affecting the liver. We report our experience with (90)Y radioembolisation (RE) and its effects on the survival of patients with treatment-refractory breast cancer liver metastases. METHODS:A total of 77 female patients affected by breast cancer ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-012-2556-5

    authors: Cianni R,Pelle G,Notarianni E,Saltarelli A,Rabuffi P,Bagni O,Filippi L,Cortesi E

    更新日期:2013-01-01 00:00:00

  • Correlation of texture analysis of paraspinal musculature on MRI with different clinical endpoints: Lumbar Stenosis Outcome Study (LSOS).

    abstract:OBJECTIVES:The aim of this study was to apply texture analysis (TA) on paraspinal musculature in T2-weighted (T2w) magnetic resonance images (MRI) of symptomatic lumbar spinal stenosis (LSS) patients and correlate the findings with clinical outcome measures. METHODS:Ninety patients were prospectively enrolled in the m...

    journal_title:European radiology

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1007/s00330-018-5552-6

    authors: Mannil M,Burgstaller JM,Held U,Farshad M,Guggenberger R

    更新日期:2019-01-01 00:00:00

  • Using computer-aided detection in mammography as a decision support.

    abstract:OBJECTIVE:To evaluate an interactive computer-aided detection (CAD) system for reading mammograms to improve decision making. METHODS:A dedicated mammographic workstation has been developed in which readers can probe image locations for the presence of CAD information. If present, CAD findings are displayed with the c...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-010-1821-8

    authors: Samulski M,Hupse R,Boetes C,Mus RD,den Heeten GJ,Karssemeijer N

    更新日期:2010-10-01 00:00:00

  • Implementation of eHealth and AI integrated diagnostics with multidisciplinary digitized data: are we ready from an international perspective?

    abstract::Digitization of medicine requires systematic handling of the increasing amount of health data to improve medical diagnosis. In this context, the integration of the versatile diagnostic information, e.g., from anamnesis, imaging, histopathology, and clinical chemistry, and its comprehensive analysis by artificial intel...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-06874-x

    authors: Bukowski M,Farkas R,Beyan O,Moll L,Hahn H,Kiessling F,Schmitz-Rode T

    更新日期:2020-10-01 00:00:00

  • A smaller heart-aorta-angle associates with ascending aortic dilatation and increases wall shear stress.

    abstract:OBJECTIVES:The aim of this study was to evaluate whether the orientation of the heart, measured as an angle between the long axis of the heart and ascending aorta midline (heart-aorta-angle, HAA), associates with ascending aortic (AA) dilatation. Furthermore, the association between HAA and wall shear stress (WSS) was ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-06852-3

    authors: Kauhanen SP,Liimatainen T,Kariniemi E,Korhonen M,Parkkonen J,Vienonen J,Vanninen R,Hedman M

    更新日期:2020-09-01 00:00:00

  • Hyperintense globus pallidus on T1-weighted MR imaging in acute kernicterus: is it common or rare?

    abstract::Globus pallidus involvement is a well-known magnetic resonance (MR) imaging finding of acute kernicterus. However, it is not clear how early the involvement of globus pallidus occurs and whether or not it is seen in every case. Therefore, we aimed to investigate the globus pallidus involvement in 13 neonates with acut...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-004-2502-2

    authors: Coskun A,Yikilmaz A,Kumandas S,Karahan OI,Akcakus M,Manav A

    更新日期:2005-06-01 00:00:00

  • Preoperative embolization of bone metastases from renal cell carcinoma.

    abstract::The purpose of this study was to correlate the effectiveness of preoperative embolization with the blood loss and transfusion requirement during surgery for bone metastases from renal cell carcinoma. Twenty-eight preoperative embolizations in 26 patients with renal cell carcinoma metastatic to bone were retrospectivel...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050969

    authors: Chatziioannou AN,Johnson ME,Pneumaticos SG,Lawrence DD,Carrasco CH

    更新日期:2000-01-01 00:00:00

  • Enhancement characteristics of liver metastases, hepatocellular carcinomas, and hemangiomas with Gd-EOB-DTPA: preliminary results with dynamic MR imaging.

    abstract::Our objective was to study Gd-EOB-DTPA for the characterization of focal liver lesions by means of dynamic MR imaging. A double-blind and randomized dose-ranging phase-2 clinical trial was performed in 31 patients (liver metastases n = 23, hepatocellular carcinoma n = 4, and hemangioma n = 4) at a field strength of 1....

    journal_title:European radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1007/s003300050150

    authors: Reimer P,Rummeny EJ,Daldrup HE,Hesse T,Balzer T,Tombach B,Peters PE

    更新日期:1997-01-01 00:00:00

  • Cystic versus predominantly cystic thyroid nodules: efficacy of ethanol ablation and analysis of related factors.

    abstract:OBJECTIVES:To compare the efficacy of ethanol ablation (EA) of cystic and predominantly cystic thyroid nodules, and to evaluate factors affecting efficacy. METHODS:From October 2008 to December 2010, a total of 217 thyroid nodules were treated with EA. Nodule volumes, symptoms and cosmetic scores were evaluated before...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-012-2406-5

    authors: Kim YJ,Baek JH,Ha EJ,Lim HK,Lee JH,Sung JY,Kim JK,Kim TY,Kim WB,Shong YK

    更新日期:2012-07-01 00:00:00