Evaluation of an organ-based tube current modulation tool in pediatric CT examinations.

Abstract:

OBJECTIVES:To investigate the effect of an organ-based tube current modulation (OTCM) technique on organ absorbed dose and assess image quality in pediatric CT examinations. METHODS:Four physical anthropomorphic phantoms that represent the average individual as neonate, 1-year-old, 5-year-old, and 10-year-old were used. Standard head and thorax acquisitions were performed with automatic tube current modulation (ATCM) and ATCM+OTCM. Dose calculations were performed by means of Monte Carlo simulations. Radiation dose was measured for superficial and centrally located radiosensitive organs. The angular range of the OTCM exposure window was determined for different tube rotation times (t) by means of a solid-state detector. Image noise was measured as the standard deviation of the Hounsfield unit value in regions of interest drawn at selected anatomical sites. RESULTS:ATCM+OTCM resulted in a reduction of radiation dose to all radiosensitive organs. In head, eye lens dose was reduced by up to 13% in ATCM+OTCM compared with ATCM. In thorax, the corresponding reduction for breast dose was up to 10%. The angular range of the OTCM exposure window decreased with t. For t = 0.4 s, the angular range was limited to 74° in head and 135° for thorax. Image noise was significantly increased in ATCM+OTCM acquisitions across most examined phantoms (p < 0.05). CONCLUSIONS:OTCM reduces radiation dose to exposed radiosensitive organs with the eye lens and breast buds exhibiting the highest dose reduction. The OTCM exposure window is narrowed at short t. An increase in noise is inevitable in images located within the OTCM-activated imaged volume. KEY POINTS:• In pediatric CT, organ-based tube current modulation reduces radiation dose to all major primarily exposed radiosensitive organs. • Image noise increases within the organ-based tube current modulation enabled imaged volume. • The angular range of the organ-based tube current modulation low exposure window is reduced with tube rotation time.

journal_name

Eur Radiol

journal_title

European radiology

authors

Papadakis AE,Damilakis J

doi

10.1007/s00330-020-06888-5

subject

Has Abstract

pub_date

2020-10-01 00:00:00

pages

5728-5737

issue

10

eissn

0938-7994

issn

1432-1084

pii

10.1007/s00330-020-06888-5

journal_volume

30

pub_type

杂志文章
  • Dose reduction in dynamic perfusion CT of the brain: effects of the scan frequency on measurements of cerebral blood flow, cerebral blood volume, and mean transit time.

    abstract::The influence of the frequency of computed tomography (CT) image acquisition on the diagnostic quality of dynamic perfusion CT (PCT) studies of the brain was investigated. Eight patients with clinically suspected acute ischemia of one hemisphere underwent PCT, performed on average 3.4 h after the onset of symptoms. Si...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-008-1083-x

    authors: Wiesmann M,Berg S,Bohner G,Klingebiel R,Schöpf V,Stoeckelhuber BM,Yousry I,Linn J,Missler U

    更新日期:2008-12-01 00:00:00

  • CT perfusion imaging of the liver and the spleen in patients with cirrhosis: Is there a correlation between perfusion and portal venous hypertension?

    abstract:OBJECTIVES:To correlate hepatic and splenic CT perfusion parameters with hepatic venous pressure gradient (HVPG) measurements in patients with cirrhosis. METHODS:Twenty-one patients with cirrhosis (males, 17; females, 4; mean ± SD age, 57 ± 7 years) underwent hepatic and splenic perfusion CT on a 320-detector row volu...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-4788-x

    authors: Talakić E,Schaffellner S,Kniepeiss D,Mueller H,Stauber R,Quehenberger F,Schoellnast H

    更新日期:2017-10-01 00:00:00

  • The effect of hippocampal function, volume and connectivity on posterior cingulate cortex functioning during episodic memory fMRI in mild cognitive impairment.

    abstract:OBJECTIVES:Diminished function of the posterior cingulate cortex (PCC) is a typical finding in early Alzheimer's disease (AD). It is hypothesized that in early stage AD, PCC functioning relates to or reflects hippocampal dysfunction or atrophy. The aim of this study was to examine the relationship between hippocampus f...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-4768-1

    authors: Papma JM,Smits M,de Groot M,Mattace Raso FU,van der Lugt A,Vrooman HA,Niessen WJ,Koudstaal PJ,van Swieten JC,van der Veen FM,Prins ND

    更新日期:2017-09-01 00:00:00

  • A simple classification system (the Tree flowchart) for breast MRI can reduce the number of unnecessary biopsies in MRI-only lesions.

    abstract:OBJECTIVES:To assess whether using the Tree flowchart obviates unnecessary magnetic resonance imaging (MRI)-guided biopsies in breast lesions only visible on MRI. METHODS:This retrospective IRB-approved study evaluated consecutive suspicious (BI-RADS 4) breast lesions only visible on MRI that were referred to our inst...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-4755-6

    authors: Woitek R,Spick C,Schernthaner M,Rudas M,Kapetas P,Bernathova M,Furtner J,Pinker K,Helbich TH,Baltzer PAT

    更新日期:2017-09-01 00:00:00

  • Correlation between quantitative assessment of contrast enhancement in contrast-enhanced spectral mammography (CESM) and histopathology-preliminary results.

    abstract:OBJECTIVES:Contrast-enhanced spectral mammography (CESM) is a novel method for breast cancer detection. The aim of this study is to check if there is a possibility of quantitative assessment of contrast enhancement in CESM and if there is any correlation between quantitative assessment of contrast enhancement in CESM a...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-019-06232-6

    authors: Rudnicki W,Heinze S,Niemiec J,Kojs Z,Sas-Korczynska B,Hendrick E,Luczynska E

    更新日期:2019-11-01 00:00:00

  • Impact of model-based iterative reconstruction on low-contrast lesion detection and image quality in abdominal CT: a 12-reader-based comparative phantom study with filtered back projection at different tube voltages.

    abstract:OBJECTIVES:To evaluate the impact of model-based iterative reconstruction (MBIR) on image quality and low-contrast lesion detection compared with filtered back projection (FBP) in abdominal computed tomography (CT) of simulated medium and large patients at different tube voltages. METHODS:A phantom with 45 hypoattenua...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-4825-9

    authors: Euler A,Stieltjes B,Szucs-Farkas Z,Eichenberger R,Reisinger C,Hirschmann A,Zaehringer C,Kircher A,Streif M,Bucher S,Buergler D,D'Errico L,Kopp S,Wilhelm M,Schindera ST

    更新日期:2017-12-01 00:00:00

  • Cortical cerebral blood flow in ageing: effects of haematocrit, sex, ethnicity and diabetes.

    abstract:OBJECTIVES:Cerebral blood flow (CBF) estimates from arterial spin labelling (ASL) show unexplained variability in older populations. We studied the impact of variation of haematocrit (Hct) on CBF estimates in a tri-ethnic elderly population. MATERIALS AND METHODS:Approval for the study was obtained from the Fulham Res...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-019-06096-w

    authors: Smith LA,Melbourne A,Owen D,Cardoso MJ,Sudre CH,Tillin T,Sokolska M,Atkinson D,Chaturvedi N,Ourselin S,Hughes AD,Barkhof F,Jäger HR

    更新日期:2019-10-01 00:00:00

  • Percutaneous sclerotherapy of a symptomatic simple renal cyst in a child: observation of membrane detachment sign.

    abstract::A 6-year-old girl with a symptomatic renal cyst underwent successful percutaneous aspiration and sclerotherapy with hypertonic saline under US guidance. Although membrane detachment sign was seen clearly during aspiration, it was confirmed to be a simple cyst. In contrast to previous reports, membrane detachment sign ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/BF00240694

    authors: Kabaalioğlu A,Apaydin A,Ozkaynak C,Melikoğlu M,Sindel T,Lüleci E

    更新日期:1996-01-01 00:00:00

  • Magnetic resonance-guided upper abdominal biopsies in a high-field wide-bore 3-T MRI system: feasibility, handling, and needle artefacts.

    abstract:OBJECTIVE:To investigate the feasibility and handling of abdominal MRI-guided biopsies in a 3-T MRI system. METHODS:Over a 1-year period, 50 biopsies were obtained in 47 patients with tumours of the upper abdominal organs guided by 3-T MRI with a large-bore diameter of 70 cm. Lesions in liver (47), spleen (1) and kidn...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-010-1809-4

    authors: Kühn JP,Langner S,Hegenscheid K,Evert M,Kickhefel A,Hosten N,Puls R

    更新日期:2010-10-01 00:00:00

  • Carcinoma of the breast wire localisation post nuclear medicine sentinel lymph node imaging. Are radiologists receiving a significant dose?

    abstract:OBJECTIVE:To assess the radiation dose received by the radiologist when performing wire localisation for axillary radio-isotope sentinel node imaging-guided biopsy in patients with impalpable breast cancers treated with breast-preserving excision. When wire placement follows radio-isotope sentinel node imaging (RSNI) t...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-009-1594-0

    authors: Meades RT,Svensson WE,Frank JW,Gada V,Ralleigh G,Satchithananda K,Barrett N,Nijran KS

    更新日期:2010-03-01 00:00:00

  • Non-invasive imaging of the great vessels of the chest.

    abstract::Several excellent imaging modalities are available for studying the great vessels of the chest noninvasively. Besides computed tomography (CT), magnetic resonance imaging (MRI) and echocardiography (in particular the transesophageal approach) can accurately depict abnormalities of the thoracic vasculature, and are a v...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s003300050516

    authors: Marchal G,Bogaert J

    更新日期:1998-01-01 00:00:00

  • Application and assessment of a robust elastic motion correction algorithm to dynamic MRI.

    abstract::The purpose of this study was to assess the performance of a new motion correction algorithm. Twenty-five dynamic MR mammography (MRM) data sets and 25 contrast-enhanced three-dimensional peripheral MR angiographic (MRA) data sets which were affected by patient motion of varying severeness were selected retrospectivel...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-006-0224-3

    authors: Herrmann KH,Wurdinger S,Fischer DR,Krumbein I,Schmitt M,Hermosillo G,Chaudhuri K,Krishnan A,Salganicoff M,Kaiser WA,Reichenbach JR

    更新日期:2007-01-01 00:00:00

  • Normal hepatic parenchyma visibility and ADC quantification on diffusion-weighted MRI at 3 T: influence of age, gender, and iron content.

    abstract:OBJECTIVES:To investigate how normal liver parenchyma visibility on 3 T diffusion-weighted images (DWI) and apparent diffusion coefficient (ADC) quantification are influenced by age, gender, and iron content. METHODS:Between February 2011 and April 2013, 86 patients (52 women) with normal livers who underwent respirat...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-014-3353-0

    authors: Metens T,Ferraresi KF,Farchione A,Moreno C,Bali MA,Matos C

    更新日期:2014-12-01 00:00:00

  • Head-to-head comparison of multiple cardiovascular magnetic resonance techniques for the detection and quantification of intramyocardial haemorrhage in patients with ST-elevation myocardial infarction.

    abstract:OBJECTIVES:T2*-weighted (T2*w) is deemed as a reference standard for post-infarction intramyocardial haemorrhage (IMH). However, high proportion of T2* images is affected by off-resonance artefacts hampering image interpretation. Diagnostic accuracy and precision of alternative techniques for IMH diagnosis and quantifi...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-07254-1

    authors: Pavon AG,Georgiopoulos G,Vincenti G,Muller O,Monney P,Berchier G,Cirillo C,Eeckhout E,Schwitter J,Masci PG

    更新日期:2020-09-14 00:00:00

  • Cerebrospinal fluid dynamics in idiopathic normal pressure hydrocephalus on four-dimensional flow imaging.

    abstract:OBJECTIVES:To evaluate complex CSF movements and shear stress in patients with idiopathic normal pressure hydrocephalus (iNPH) on four-dimensional (4D) flow MRI. METHODS:Three-dimensional velocities and volumes of the reciprocating CSF movements through 12 ROIs from the foramen of Monro to the upper cervical spine wer...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-06825-6

    authors: Yamada S,Ishikawa M,Ito H,Yamamoto K,Yamaguchi M,Oshima M,Nozaki K

    更新日期:2020-08-01 00:00:00

  • Pitfalls in sonography of the Gamekeeper's thumb.

    abstract::The gamekeeper's or skier's thumb is a very common injury. Nondisplaced tears of the ulnar collateral ligament of the thumb (UCL) may be treated conservatively. For that reason an accurate diagnosis is mandatory for choosing the correct therapy. Ultrasound is able to depict the position of the torn UCL correctly in ap...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050111

    authors: Hergan K,Mittler C,Oser W

    更新日期:1997-01-01 00:00:00

  • Pace of macrophage recruitment during different stages of soft tissue infection: semi-quantitative evaluation by in vivo magnetic resonance imaging.

    abstract::We describe the pace of recruitment of iron-oxide-labeled macrophages to the site of different stages of infection by in vivo magnetic resonance (MR) imaging. Peritoneal macrophages were labeled with superparamagnetic iron oxide ex vivo and administered through the tail vein 6 (acute) or 48 (subacute) h after bacteria...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-008-0975-0

    authors: Lee JS,Sohn JY,Jung HD,Kim ST,Lee KG,Kang HJ

    更新日期:2008-10-01 00:00:00

  • Subcentimeter hypervascular nodules with typical imaging findings of hepatocellular carcinoma on gadoxetic acid-enhanced MRI: Outcomes of early treatment and watchful waiting.

    abstract:OBJECTIVES:To compare treatment outcomes of subcentimeter hypervascular nodules at high risk for developing into hepatocellular carcinomas (SHNHR) between early treatment and watchful waiting until progression to overt hepatocellular carcinoma (HCC) groups. METHODS:SHNHRs were defined as subcentimeter hypervascular no...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-4818-8

    authors: Woo JH,Song KD,Kim SH

    更新日期:2017-10-01 00:00:00

  • Thread sign in biliary intraductal papillary mucinous neoplasm: a novel specific finding for MRI.

    abstract:OBJECTIVES:To evaluate thread sign of biliary intraductal papillary mucinous neoplasm (B-IPMN) on magnetic resonance imaging (MRI). METHODS:Thread sign was defined as intraductal linear or curvilinear hypointense striations. Two radiologists independently evaluated the presence and location of thread sign on MR cholan...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-4158-5

    authors: Hong GS,Byun JH,Kim JH,Kim HJ,Lee SS,Hong SM,Lee MG

    更新日期:2016-09-01 00:00:00

  • Can enhancement types on preoperative MRI reflect prognostic factors and surgical outcomes in invasive breast cancer?

    abstract:OBJECTIVES:This study was conducted in order to evaluate whether enhancement types on preoperative MRI can reflect prognostic factors and surgical outcomes in invasive breast cancer. METHODS:Among 484 consecutive patients who underwent preoperative breast MRI from October 2014 to July 2017 for biopsy-proven breast can...

    journal_title:European radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s00330-019-06236-2

    authors: Koh J,Park AY,Ko KH,Jung HK

    更新日期:2019-12-01 00:00:00

  • Development of automatic measurement for patellar height based on deep learning and knee radiographs.

    abstract:OBJECTIVES:To develop and evaluate the performance of a deep learning-based system for automatic patellar height measurements using knee radiographs. METHODS:The deep learning-based algorithm was developed with a data set consisting of 1018 left knee radiographs for the prediction of patellar height parameters, specif...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-06856-z

    authors: Ye Q,Shen Q,Yang W,Huang S,Jiang Z,He L,Gong X

    更新日期:2020-09-01 00:00:00

  • Relationship between histologic thickness of tongue carcinoma and thickness estimated from preoperative MRI.

    abstract::Several studies have shown that the thickness of tongue carcinoma is related to prognosis and to the likelihood of cervical node metastases. We investigated whether preoperative estimates of tumor thickness and volume, as determined from magnetic resonance imaging (MRI), correlated with histologic thickness and might ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-006-0263-9

    authors: Preda L,Chiesa F,Calabrese L,Latronico A,Bruschini R,Leon ME,Renne G,Bellomi M

    更新日期:2006-10-01 00:00:00

  • Transcatheter arterial chemoembolization in patients with hepatocellular carcinoma and coexisting hepatic cavernous hemangioma.

    abstract::We investigated the consequence of repeated transcatheter arterial chemoembolization (TACE) for coexisting small hepatic hemangioma in the treatment of patients with hepatocellular carcinomas and describe the imaging features of embolized hemangioma on the follow-up Lipiodol CT and MR. Six of 431 patients with biopsy-...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-005-0074-4

    authors: Chen RC,Lii JM,Chen WT,Tu HY,Chiang LC

    更新日期:2006-06-01 00:00:00

  • The efficiency of acoustic radiation force impulse imaging for the staging of liver fibrosis: a meta-analysis.

    abstract:OBJECTIVES:Acoustic radiation force impulse (ARFI) imaging is an ultrasound-based elastography method that is integrated into a conventional ultrasound machine. A meta-analysis based on original and abstract publications was performed to evaluate the overall performance of ARFI for the diagnosis of liver fibrosis. MET...

    journal_title:European radiology

    pub_type: 杂志文章,meta分析,评审

    doi:10.1007/s00330-013-2927-6

    authors: Nierhoff J,Chávez Ortiz AA,Herrmann E,Zeuzem S,Friedrich-Rust M

    更新日期:2013-11-01 00:00:00

  • Visual stimulation, 1H MR spectroscopy and fMRI of the human visual pathways.

    abstract::The purpose was to assess changes in lactate content and other brain metabolites under visual stimulation in optical chiasm, optic radiations and occipital cortex using multiple voxel MR spectroscopy (MRS). 1H chemical shift imaging (CSI) examinations of transverse planes centered to include the above structures were ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-004-2494-y

    authors: Boucard CC,Mostert JP,Cornelissen FW,De Keyser J,Oudkerk M,Sijens PE

    更新日期:2005-01-01 00:00:00

  • Salvage RFA in patients with intrahepatic recurrence after major hepatic surgery for colorectal cancer liver metastases: mid-term outcome.

    abstract:OBJECTIVES:To evaluate the mid-term outcome of salvage radiofrequency ablation (RFA) treatment in patients who exhibited intrahepatic recurrence after major hepatectomy for colorectal liver metastases (CRCLM). METHODS:Observational study on 23 consecutive patients (mean age 59 ± 9 years; 14/9 male/female) who, after a...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-019-06421-3

    authors: Zimmermann M,Pedersoli F,Schulze-Hagen M,Lurje G,Isfort P,Kuhl C,Bruners P

    更新日期:2020-02-01 00:00:00

  • Diffusion-weighted imaging or dynamic contrast-enhanced curve: a retrospective analysis of contrast-enhanced magnetic resonance imaging-based differential diagnoses of benign and malignant breast lesions.

    abstract:OBJECTIVE:To compare the diagnostic performance of models based on a combination of contrast-enhanced (CE) magnetic resonance imaging (MRI) with diffusion-weighted imaging (DWI) or time-intensity curves (TIC) in diagnosing malignancies of breast lesions. METHODS:A double-blind retrospective study was conducted in 328 ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-06883-w

    authors: Yang X,Dong M,Li S,Chai R,Zhang Z,Li N,Zhang L

    更新日期:2020-09-01 00:00:00

  • Herlyn-Werner-Wunderlich syndrome: a rare cause of infertility (2009: 2b).

    abstract::Uterus didelphys with obstructed hemivagina and ipsilateral renal agenesis is a rare and specific entity referred to as Herlyn-Werner-Wunderlich syndrome. It usually presents after menarche with remittent pelvic pain and a palpable pelvic mass due to hematocolpos. It rarely presents with primary infertility in early a...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-008-1085-8

    authors: Sarac A,Demir MK

    更新日期:2009-05-01 00:00:00

  • 3D black-blood 3T-MRI for the diagnosis of abdominal large vessel vasculitis.

    abstract:OBJECTIVES:To assess the value of a T1-3D black-blood turbo spin echo (TSE) sequence for the diagnosis of abdominal large vessel vasculitis (LVV). MATERIALS AND METHODS:The study included 20 patients with abdominal LVV and 17 controls, who underwent a 3T-MRI scan using a modified T1-3D volumetric isotropic TSE acquisi...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-019-06432-0

    authors: Maurus S,Sommer NN,Kooijman H,Coppenrath E,Witt M,Schulze-Koops H,Czihal M,Hoffmann U,Saam T,Treitl KM

    更新日期:2020-02-01 00:00:00

  • CAD-RADS - a new clinical decision support tool for coronary computed tomography angiography.

    abstract::Coronary computed tomography angiography (CTA) has been established as an accurate method to non-invasively assess coronary artery disease (CAD). The proposed 'Coronary Artery Disease Reporting and Data System' (CAD-RADS) may enable standardised reporting of the broad spectrum of coronary CTA findings related to the p...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-017-5105-4

    authors: Foldyna B,Szilveszter B,Scholtz JE,Banerji D,Maurovich-Horvat P,Hoffmann U

    更新日期:2018-04-01 00:00:00